Genomic DNA from blood

Similar documents
Genomic DNA from forensic samples

Genomic DNA from forensic samples

RNA and DNA purification

Genomic DNA from forensic samples

Processing of 8-well strips under vacuum

Plasmid DNA concentration and desalination

Plasmid DNA concentration and desalination

RNA and DNA purification

RNA from blood. User manual. NucleoSpin 96 RNA Blood. May 2014 / Rev. 02

Total RNA and DNA Purification

SPEEDTOOLS DNA EXTRACTION KIT

Circulating DNA from plasma

Genomic DNA from plant

Processing of 8-well strips under centrifugation

Genomic DNA from tissue

User manual MACHEREY-NAGEL. NucleoSpin RNA/ DNA buffer set. April 2005/Rev. 02

NucleoMag SEP Magnetic Separator

Genomic DNA clean-up

Plasmid DNA purification

Circulating DNA from plasma

Genomic DNA from FFPE samples

Circulating DNA from plasma

Small RNA and DNA from Plasma

Plasmid DNA purification

Viral RNA and DNA. User manual. NucleoSpin Virus. April 2017 / Rev. 03.

Genomic DNA from FFPE samples

Viral RNA and DNA isolation

PCR clean-up. User manual. NucleoSpin 96 PCR Clean-up NucleoSpin 96 PCR Clean-up Core Kit. April 2014 / Rev. 04

PCR clean-up Gel extraction

Genomic DNA from food

Genomic DNA from tissue

Genomic DNA clean-up

Clean-up of Sequencing Reactions

Genomic DNA from organs and cells

Genomic DNA from food

Circulating DNA from plasma

Genomic DNA from food

Plasmid DNA purification

Purification of poly(a) RNA

Genomic DNA from tissue

Total RNA isolation. User manual. NucleoSpin 96 RNA NucleoSpin 96 RNA Core Kit. April 2014 / Rev. 05

Genomic DNA from blood

ISOLATE II Blood DNA Kit. Product Manual

Genomic DNA from food

Genomic DNA from Tissue

LysoBead Direct-to-PCR Extraction Kit

Genomic DNA from blood

RNA and DNA from soil

Viral RNA and DNA isolation

PureColumn DNA Extraction Kit

Plasmid DNA purification

Plasmid DNA purification

PureColumn DNA Extraction Kit

Plasmid DNA Purification

Small RNA and DNA from Plasma

Viral RNA isolation. User manual. NucleoSpin RNA Virus NucleoSpin RNA Virus F. July 2014 / Rev. 11

PureColumn DNA Extraction Kit

Genomic DNA from insects

DNA from food. User manual. NucleoMag DNA Food. August 2017 / Rev. 01.

Plasmid and large-construct DNA purification

Register your instrument! MagSep Blood gdna Kit. Instructions for use

Thermo Scientific GeneJET Whole Blood RNA Purification Mini Kit #K0761

Small RNA and DNA from plasma

Isolation of small and large RNA

Genomic DNA from organs and cells

Instructions for Use

User manual MACHEREY-NAGEL. NucleoSpin RNA Clean-up. NucleoBond PC 500 NucleoBond BAC 100 NucleoBond PC 2000 PC October 2004/Rev.

Genomic DNA from Plant

SPEEDTOOLS PLASMID DNA PURIFICATION KIT

Genomic DNA from soil

Genomic DNA from Blood

Genomic DNA from soil

Instructions for Use (Ref /2)

Plasmid DNA purification

Plasmid DNA purification

RNA from blood. User manual. NucleoSpin RNA Blood NucleoSpin RNA Blood Midi. September 2017 / Rev. 05.

Genomic DNA from microoganisms

Genomic DNA from microoganisms

Genomic DNA from Plasma

India Contact: Life Technologies (India) Pvt. Ltd.

DNA isolation from FFPE samples

Genomic DNA from stool samples

Purification of His-tag proteins

Genomic DNA from soil

Genomic DNA from soil

PCR clean-up. User manual. NucleoFast 96 PCR. June 2017 / Rev. 06.

Viral DNA / RNA Isolation

Viral DNA / RNA Isolation

Viral nucleic acid isolation

Instructions for Use (Cat. No /2)

RNA isolation from plant and fungi

SPEEDTOOLS RNA VIRUS EXTRACTION KIT

Plus Blood Genomic DNA Purification Kit

E.Z.N.A. Blood DNA Maxi Kit. D preps D preps

E.Z.N.A. Blood DNA Maxi Kit. D preps D preps

Plasmid DNA purification

Total RNA Isolation. User Manual. NucleoSpin 8 RNA NucleoSpin 96 RNA MACHEREY-NAGEL. January 2009/ Rev. 03

Viral RNA isolation. User manual. NucleoSpin RNA Virus NucleoSpin RNA Virus F MACHEREY-NAGEL. March 2012 / Rev. 10

Presto 96 Well gdna Bacteria Kit

Life science unlimited

Transcription:

Genomic DNA from blood User manual NucleoSpin Blood L Vacuum May 2014 / Rev. 01

Table of contents 1 Components 4 1.1 Kit contents 4 1.2 Reagents, consumables, and equipment to be supplied by user 5 1.3 About this user manual 5 2 Product description 6 2.1 The basic principle 6 2.2 Kit specifications 6 2.3 Required hardware 6 2.4 Storage of blood samples 7 2.5 Elution procedures 7 3 Storage conditions and preparation of working solutions 8 4 Safety instructions 9 5 Protocol Genomic DNA purification with NucleoSpin Blood L Vacuum 11 6 Appendix 17 6.1 Troubleshooting 17 6.2 Ordering information 19 6.3 Product use restriction / warranty 19 MACHEREY-NAGEL 05/ 2014, Rev. 01 3

1 Components 1.1 Kit contents NucleoSpin Blood L Vacuum 24 preps REF 740954.24 Lysis Buffer BLV1 Binding Buffer BLV2 Wash Buffer BLV3 Wash Buffer BLV4 (Concentrate)* Elution Buffer BLV5** Liquid Proteinase K 25 ml 125 ml 125 ml 25 ml 30 ml 1.4 ml NucleoSpin Blood L Columns 24 Collection Tubes (1.5 ml) 24 Lysis Block 1 Sample Waste Block 1 User manual 1 * For preparation of working solutions and storage conditions see section 3. ** Composition of Elution Buffer BLV5: 5 mm Tris/HCl, ph 8.5 4 MACHEREY-NAGEL 05 / 2014, Rev. 01

1.2 Reagents, consumables, and equipment to be supplied by user Reagents 96 100 % ethanol Phosphate-buffered saline (PBS) may be required for some samples Consumables Disposable pipette tips Equipment NucleoVac 96 Vacuum Manifold Starter Set Midi (see ordering information) Thermal heating shaker Personal protection equipment (lab coat, gloves, goggles) 1.3 About this user manual It is strongly recommended reading the detailed protocol sections of this user manual if the NucleoSpin Blood L Vacuum kit is used for the first time. All technical literature is available on the internet at www.mn-net.com. Please contact Technical Service regarding information about changes of the current user manual compared to previous revisions. MACHEREY-NAGEL 05/ 2014, Rev. 01 5

2 Product description 2.1 The basic principle With the NucleoSpin Blood L Vacuum method, genomic DNA is prepared from whole blood. Lysis is achieved by incubation of whole blood in a solution containing large amounts of chaotropic ions in the presence of Proteinase K. Appropriate conditions for binding of DNA to the silica membrane of the corresponding NucleoSpin Blood L Columns are achieved by addition of Binding Buffer BLV2 to the lysate. The binding process is reversible and specific to nucleic acids. Washing steps efficiently remove contaminations. Pure genomic DNA is finally eluted under low ionic strength conditions in a slightly alkaline elution buffer. 2.2 Kit specifications NucleoSpin Blood L Vacuum kits are designed for the rapid isolation of highly pure genomic DNA from whole blood. DNA can be purified successfully from blood samples treated with EDTA, citrate, or heparin. If leukocyte rich materials like buffy coat are used, apply smaller volumes and dilute the samples with sterile PBS (dissolve 8 g NaCl, 0.2 g KCl, 1.44 g Na 2 HPO 4, and 0.24 g KH 2 PO 4 in 800 ml H 2 O. Adjust ph to 7.4 with HCl. Add H 2 O to 1 liter). The kits allow purification of highly pure genomic DNA with an A 260 / A 280 ratio between 1.60 and 1.90 and a typical concentration of 40 80 μg dependent on sample material. The obtained DNA is ready-to-use for subsequent reactions like PCR, Southern blotting, or any kind of enzymatic reactions. 2.3 Required hardware Vacuum processing The NucleoSpin Blood L Vacuum kit is used with the NucleoVac 96 Vacuum Manifold (see ordering information). Additional to the vacuum manifold, special adapter frames (included in the Starter Set Midi) are needed for processing up to 24 NucleoSpin Blood L Columns on the NucleoVac 96 Vacuum Manifold. The Starter Set Midi (see ordering information) contains a Column Holder Midi for holding up to 24 NucleoSpin Blood L Columns, a Wash Plate Midi, for preventing cross-contamination, and the Elution Tube Holder Midi for holding the Elution Tubes inside the vacuum manifold. For the use of less than 24 columns, Dummy Columns are included. 6 MACHEREY-NAGEL 05 / 2014, Rev. 01

The manifold may be used with a vacuum pump, house vacuum, or water respirator. We recommend a vacuum of -0.2 to -0.6 bar (reduction of atmospheric pressure). The use of the NucleoVac Vacuum Regulator (see ordering information) is recommended. 2.4 Storage of blood samples For the isolation of genomic DNA from blood treated with anticoagulants (heparin, citrate, or EDTA) using a NucleoSpin Blood L Vacuum kit the blood samples can be stored at room temperature, +4 C, or frozen. Blood samples stored at room temperature or +4 C for up to several days or weeks, respectively, will still allow DNA isolation. However, DNA yield and quality will slowly decrease due to prolonged storage of blood samples under these conditions. Blood stored frozen for years is well suited for DNA isolation. Highest yields and quality of DNA are obtained from fresh blood. 2.5 Elution procedures It is possible to adapt elution method and volume of elution buffer to the subsequent application of interest. In addition to the standard method (recovery rate about 70 90 %) there are several modifications possible. High yield: Use elution buffer preheated to 70 C to obtain higher yields. High concentration: Perform one elution step with 60 % of the volume indicated in the individual protocol. Concentration of DNA will be higher than with standard elution (around 100 %). Elution may also be performed with Tris-EDTA-buffer (TE) of ph equal or higher than 8. This will increase DNA stability especially during long term and / or multi use storage at 4 C or ambient temperature by inhibition of omnipresent DNases. However, EDTA interferes, depending on the final concentration, with certain downstream applications. For optimal performance of isolated DNA in subsequent downstream applications we recommend elution with the supplied elution buffer and storage, especially long term, at -20 C. Several freeze-thaw cycles will not interfere with most downstream applications. Performance of long-range PCR (e.g., > 10 kbp) or detection sensitivity of trace amount of DNA species might be reduced after multiple freeze-thaw cycles or prolonged storage of eluted DNA at +4 C or room temperature due to DNA shearing or adsorption to surfaces. MACHEREY-NAGEL 05/ 2014, Rev. 01 7

3 Storage conditions and preparation of working solutions Attention: Buffers BLV1, BLV2, and BLV3 contain chaotropic salt. Wear gloves and goggles! CAUTION: Buffer BLV1, BLV2, and BLV3 contain guanidine hydrochloride which can form highly reactive compounds when combined with bleach (sodium hypochlorite). DO NOT add bleach or acidic solutions directly to the sample-preparation waste. Buffers and consumables can be stored at room temperature (18 25 C) and are stable up to one year. NucleoSpin Blood L Columns have to be stored at 4 C and are stable up to one year. During storage, especially at low temperatures, a white precipitate may form in Buffer BLV1. Such precipitates can be easily dissolved by incubating the bottle at 70 C before use. Before starting any NucleoSpin Blood L Vacuum protocol prepare the following: Wash Buffer BLV4: Add the indicated volume of ethanol (96 100 %) to Wash Buffer BLV4 Concentrate. Mark the label of the bottle to indicate that ethanol was added. Store Wash Buffer BLV4 at room temperature (18 25 C) for up to one year. Liquid Proteinase K: Liquid Proteinase K is ready to use. After first time use, store Liquid Proteinase K at 4 C or -20 C. NucleoSpin Blood L Vacuum 24 preps REF 740954.24 Wash Buffer BLV4 (Concentrate) 25 ml Add 100 ml ethanol 8 MACHEREY-NAGEL 05 / 2014, Rev. 01

4 Safety instructions The following components of the NucleoSpin Blood L Vacuum kits contain hazardous contents. Wear gloves and goggles and follow the safety instructions given in this section. GHS classification Only harmful features do not need to be labeled with H and P phrases up to 125 ml or 125 g. Mindergefährliche Eigenschaften müssen bis 125 ml oder 125 g nicht mit H- und P-Sätzen gekennzeichnet werden. Component Hazard contents GHS symbol Hazard phrases Precaution phrases Inhalt Gefahrstoff GHS Symbol H-Sätze P-Sätze BLV1 BLV2 BLV3 Liquid Proteinase K Guanidine hydrochloride 50 66 % Guanidinhydrochlorid 50 66 % Guanidine hydrochloride 24 36 % + ethanol 35 55 % Guanidinhydrochlorid 50 66 % + Ethanol 35 55 % Guanidine hydrochloride 36 50 % + isopropanol 20 50 % Guanidinhydrochlorid 36 50 % + Isopropanol 20 50 % Proteinase K, liquid (1 10 %) Proteinase K, flüssig (1 10 %) Warning 302, 315, 319 Achtung 280, 301+312, 302+352, 305+351+338, 330, 332+313, 337+313 Warning 226, 302 210, 233, 301+312, 33, 403+235 Achtung Warning 226, 302, 319 Achtung 210, 233, 280, 301+312, 305+351+338, 330, 337+313, 403+235 Danger Gefahr 317, 334 261, 272, 280, 302+352, 304+340, 333+313, 342+311, 363 Hazard phrases H 226 Flammable liquid and vapour. Flüssigkeit und Dampf entzündbar. H 302 Harmful if swallowed. Gesundheitsschädlich bei Verschlucken. H 315 Causes skin irritation. Verursacht Hautreizungen. H 317 May cause an allergic skin reaction. Kann allergische Hautreaktionen verursachen. H 319 Causes serious eye irritation. Verursacht schwere Augenreizung. H 334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. Kann bei Einatmen Allergie, asthmaartige Symptome oder Atembeschwerden verursachen. MACHEREY-NAGEL 05/ 2014, Rev. 01 9

Precaution phrases P 210 P 233 P 261 P 272 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Von Hitze, heißen Oberflächen, Funken, offenen Flammen sowie anderen Zündquellenarten fernhalten. Nicht rauchen. Keep container tightly closed. Behälter dicht verschlossen halten. Avoid breathing dust. Einatmen von Staub vermeiden. Contaminated work clothing should not be allowed out of the workplace. Kontaminierte Arbeitskleidung nicht außerhalb des Arbeitsplatzes tragen. P 280 P 301+312 P 302+352 P 304+340 P 305+351+338 P 330 P 332+313 P 333 + 313 P 337+313 P 342+311 P 363 P 403+235 Wear protective gloves / eye protection. Schutzhandschuhe / Augenschutz tragen. IF SWALLOWED: Call a POISON CENTER/ doctor/ /if you feel unwell. BEI VERSCHLUCKEN: Bei Unwohlsein GIFTINFORMATIONSZENTRUM / Arzt / anrufen. IF ON SKIN: Wash with plenty of water/ BEI KONTAKT MIT DER HAUT: Mit viel Wasser/ waschen. IF INHALED: If breathing is difficult, remove to fresh air and keep at rest in a position comfortable for breathing. BEI EINATMEN: An die frische Luft bringen und in einer Position ruhigstellen, die das Atmen erleichtert. IF IN EYES: Rinse continuously with water for several minutes. Remove contact lenses if present and easy to do continue rinsing. BEI KONTAKT MIT DEN AUGEN: Einige Minuten lang behutsam mit Wasser spülen. Vorhandene Kontaktlinsen nach Möglichkeit entfernen. Weiter spülen. Rinse mouth. Mund ausspülen. If skin irritation occurs: Get medical advice / attention. Bei Hautreizung: Ärztlichen Rat einholen / ärztliche Hilfe hinzuziehen. If skin irritation or a rash occurs: Get medical advice/attention. Bei Hautreizung oder -ausschlag: Ärztlichen Rat einholen / ärztliche Hilfe hinzuziehen. Get medical advice / attention. Bei anhaltende Augenreizung: Ärztlichen Rat einholen / ärztliche Hilfe hinzuziehen. If experiencing respiratory symptoms: Call a POISON CENTER/ doctor/ Bei Symptomen der Atemwege: GIFTINFORMATIONSZENTRUM /Arzt/ anrufen. Wash contaminated clothing before reuse. Kontaminierte Kleidung vor erneutem Tragen waschen. Store in a well ventilated place. Keep cool. Kühl an einem gut belüfteten Ort aufbewahren. For further information please see Material Safety Data Sheets (www.mn-net.com). Weiterführende Informationen finden Sie in den Sicherheitsdatenblättern (www.mn-net.com). 10 MACHEREY-NAGEL 05 / 2014, Rev. 01

SQUARE - WELL BLOCK NucleoSpin Blood L Vacuum 5 Protocol Genomic DNA purification with NucleoSpin Blood L Vacuum Setup of vacuum manifold: Binding step Washing step Step 4: Place the NucleoSpin L Columns inserted in the Column Holder Midi on top of the manifold lid. Unused positions have to be filled with Dummy Columns. Step 3: Place the manifold lid on top of the manifold base. Step 4: Place the NucleoSpin L Columns inserted in the Column Holder Midi on top of the manifold lid. Unused positions have to be filled with Dummy Columns. Step 3: Place the manifold lid on top of the manifold base. Step 2: Place the Sample Waste Block in the manifold. Step 2: Place the Wash Plate Midi in the manifold. Step 1: Insert spacers SQUARE-WELL BLOCK in the manifold. Step 1: Insert spacers MTP/MULTI-96 PLATE and the waste container in the manifold base. Final setup Final setup MACHEREY-NAGEL 05/ 2014, Rev. 01 11

MICROTUBE RACK MICROTUBE RACK NucleoSpin Blood L Vacuum Setup of vacuum manifold: Drying step Elution step Step 3: Place the NucleoSpin L Columns inserted in the Column Holder Midi on top of the manifold lid. Unused positions have to be filled with Dummy Columns. Step 2: Place the manifold lid on top of the manifold base. Step 4: Place the NucleoSpin L Columns inserted in the Column Holder Midi on top of the manifold lid. Unused positions have to be filled with Dummy Columns. Step 3: Place the manifold lid on top of the manifold base. Step 2: Place the 1.5 ml Collection Tubes inserted the Elution Tube Holder Midi in the manifold. Step 1: Insert the equiped waste container in the manifold base. MICROTUBE RACK Step 1: Insert spacers MICROTUBE RACK in the manifold base. Final setup Final setup 12 MACHEREY-NAGEL 05 / 2014, Rev. 01

NucleoSpin Blood L Vacuum Before starting the preparation: For hardware requirements, refer to section 2.3. For detailed information regarding vacuum manifold, see page 11. Check if Buffer BLV4 was prepared according to section 3. Set a thermal heating shaker to 56 C. 1 Lyse blood sample Pipette up to 2 ml blood sample (equilibrated to room temperature) and 50 μl Liquid Proteinase K (if processing less than 2 ml blood, add the adapted volume of liquid Proteinase K) into the Lysis Block. Add 750 μl Lysis Buffer BLV1 (if processing less than 2 ml blood, add the adapted volume of Buffer BLV1). Incubate samples at 56 C and 1200 rpm for 30 min. Let the samples cool down to room temperature before proceeding with addition of Binding Buffer BLV2. The lysate should become brownish during incubation with Buffer BLV1. Increase incubation time with Proteinase K (up to 60 min) and mix once or twice during incubation if older or clotted blood samples are processed. 2 ml blood + 50 μl Liquid Proteinase K + 750 μl BLV1 Shaking 30 min 56 C, 1200 rpm Place spacers SQUARE-WELL BLOCK, Sample Waste Block, and Wash Plate Midi into vacuum manifold base. Place the manifold lid and the NucleoSpin L Columns inserted in the Column Holder Midi on the top of the manifold lid. 2 Adjust DNA binding conditions Add 4 ml BLV2 (if processing less than 2 ml blood, add the adapted volume of BLV2) to each sample and mix by pipetting up and down 5 times. Be sure that the lysate has cooled down to room temperature before loading it onto the column. Loading of hot lysate may lead to diminished yields. + 4 ml BLV2 Mix 5 times * Reduction of atmospheric pressure MACHEREY-NAGEL 05/ 2014, Rev. 01 13

NucleoSpin Blood L Vacuum 3 Bind DNA For preparation, take the required number of NucleoSpin Blood L Columns and place them into Column Holder Midi. Place Dummy Columns in unused positions of the adapter. Transfer 3.5 ml of lysate carefully to NucleoSpin Blood L Columns. Overlay lysate slowly with 300 μl Buffer BLV4. Apply vacuum (-0.2 to -0.4 bar*; 5 min) until all lysates have passed through the NucleoSpin Blood L Columns. Release vacuum. Note: Do not moisten the rims of the individual columns while dispensing the lysate. Moisten rims may cause crosscontamination. Load all of the remaining lysate in a second step to the respective NucleoSpin Blood L Column, avoiding moistening the rim. Overlay lysate slowly with 300 μl Buffer BLV4. Apply vacuum (-0.2 to -0.4 bar*; 5 min) until all lysates have passed through the NucleoSpin Blood L Columns. 3.5 ml lysate + 300 μl BLV4 overlay Vacuum -0.2 to -0.4 bar*, 5 min Remaining lysate + 300 μl BLV4 overlay Vacuum -0.2 to -0.4 bar*, 5 min Close the valve, release the vacuum, and remove Column Holder Midi including NucleoSpin Blood L Columns from the vacuum manifold. Put the Column Holder Midi on a clean paper towel to remove residual lysate. Remove manifold lid and Sample Waste Block. Place spacers MTP/MULTI-96 PLATE, waste container, and Wash Plate Midi into the vacuum manifold base. * Reduction of atmospheric pressure 14 MACHEREY-NAGEL 05 / 2014, Rev. 01

NucleoSpin Blood L Vacuum 4 Wash silica membrane 1 st wash Add 4 ml Buffer BLV3 to each NucleoSpin Blood L Column. Incubate for 5 min at room temperature to wash away lysate residuals from the columns sides. Apply vacuum (-0.4 to -0.6 bar*; 2 min) until all buffer has passed through NucleoSpin Blood L Columns. Release the vacuum. 2 nd wash Add 2 ml Buffer BLV4 to each NucleoSpin Blood L Column. Apply vacuum (-0.4 to -0.6 bar*; 2 min) until all buffer has passed through NucleoSpin Blood L Columns. Release the vacuum. + 4 ml BLV3 Incubate at RT, 5 min Vacuum -0.4 to -0.6 bar*, 2 min + 2 ml BLV4 Vacuum -0.4 to -0.6 bar*, 2 min 3 rd wash Add 2 ml Buffer BLV4 to each NucleoSpin Blood L Column. Apply vacuum (-0.4 to -0.6 bar*; 2 min) until all buffer has passed through NucleoSpin Blood L Columns. Release the vacuum. + 2 ml BLV4 Vacuum -0.4 to -0.6 bar*, 2 min After the final washing step, close the valve, release the vacuum, and remove Column Holder Midi including NucleoSpin Blood L Columns from the vacuum manifold. Put it on a clean paper towel to remove residual ethanol containing wash buffer. Remove manifold lid, Wash Plate Midi, and waste container from the vacuum manifold. Remove any residual washing buffer from the outlets of NucleoSpin Blood L Columns. If necessary, tap the outlets onto a clean paper sheet or soft tissue until no drops come out. Insert emptied and cleaned wash container into the manifold base. Put Column Holder Midi including the NucleoSpin Blood L Columns onto the manifold lid and place afterwards the lid onto the manifold base. * Reduction of atmospheric pressure MACHEREY-NAGEL 05/ 2014, Rev. 01 15

NucleoSpin Blood L Vacuum 5 Dry silica membrane Apply maximum vacuum (at least - 0.6 bar*) for 10 min to dry the membrane completely. This step is necessary to eliminate traces of ethanol. Finally, release the vacuum. Note: The ethanol in Buffer BLV4 inhibits enzymatic reactions and has to be removed completely before eluting DNA. Vacuum at least - 0.6 bar*, 10 min After drying step close the valve, release the vacuum, and remove the Column Holder Midi including NucleoSpin Blood L Columns from the vacuum manifold. Put it on a clean paper towel. Insert spacers MICROTUBE RACK and Elution Tube Holder Midi including 1.5 ml Collection Tubes into vacuum manifold base. Put Column Holder Midi including the NucleoSpin Blood L Columns onto the manifold lid and place afterwards the lid onto the manifold base. 6 Elute highly pure DNA Add 300 μl Buffer BLV5 directly to the center of the silica membrane. Incubate at room temperature for 2 min. Apply vacuum (- 0.4 bar*; 1min and - 0.6 bar*; 1min) until all buffer has passed through NucleoSpin Blood L Columns. Release the vacuum. Add 300 μl Buffer BLV5 directly to the center of the silica membrane. Incubate at room temperature for 2 min. Apply vacuum (- 0.4 bar*; 1min and - 0.6 bar*; 1min) until all buffer has passed through NucleoSpin Blood L Columns. Release the vacuum. For alternative elution procedures see section 2.4. + 300 μl BLV5 Incubate at RT, 2 min Vacuum - 0.4 bar*, 30 s + - 0.6 bar*, 30 s + 300 μl BLV5 Incubate at RT, 2 min Vacuum - 0.4 bar*, 30 s + - 0.6 bar*, 30 s * Reduction of atmospheric pressure 16 MACHEREY-NAGEL 05 / 2014, Rev. 01

6 Appendix 6.1 Troubleshooting Problem Possible cause and suggestions Low concentration of leukocytes in sample Prepare buffy coat from the blood sample: Centrifuge whole blood at room temperature (3,300 x g; 10 min). Three different layers will be visible after centrifugation. Leukocytes are concentrated in the intermediate layer (= buffy coat). No or poor DNA yield Reagents not applied properly Prepare buffers according to instructions (section 3). Add Binding Buffer BLV2 to lysates before loading them on columns. Suboptimal elution of DNA from the column Preheat Buffer BLV5 to 70 C before elution. Apply Buffer BLV5 directly onto the center of the silica membrane. Elution efficiencies decrease dramatically if elution is performed with buffers of ph < 7.0. Use slightly alkaline elution buffer like Buffer BLV5 (ph 8.5). Mix by pipetting up and down during the 56 C incubation step especially when working with older or clotted blood samples. Poor DNA quality Reagents not applied properly Prepare buffers according to instructions (section 3). Add Binding Buffer BLV2 to lysates and mix before loading them on columns. Incomplete cell lysis Sample not thoroughly mixed with lysis buffer / Proteinase K. The sample has to be mixed vigorously immediately after addition of lysis buffer. MACHEREY-NAGEL 05/ 2014, Rev. 01 17

RNA in sample If RNA-free DNA is desired, add RNase A solution (20 mg/ml; not supplied with the kit, see ordering information) before addition of lysis buffer. Poor DNA quality (continued) Old or clotted blood samples processed For isolation of DNA from older or clotted blood samples, we recommend prolonging Proteinase K incubation to 40 60 min and mix by pipetting up and down several times during this step. Clear lysate before addition of Binding Buffer BLV2. It is recommended performing a short centrifugation step of about 30 60 s after the lysis of the sample material (before addition of Binding Buffer BLV2) in order to pellet non-lysed clumps. Carry-over of ethanol Be sure to remove all of ethanolic Buffer BLV4 before eluting the DNA. Suboptimal performance of genomic DNA in enzymatic reactions Contamination of DNA with inhibitory substances If DNA has been eluted with Tris / EDTA-buffer (TE), make sure that EDTA does not interfere with downstream applications or repurify DNA and elute in Buffer BLV5. If the A 260 / A 280 ratio of the eluate is below 1.6, repeat the purification procedure: Add 1 volume of Buffer BLV1 plus 1 volume of Buffer BLV2 to the eluate, load on NucleoSpin Blood L Column, and proceed with step 3 of the corresponding protocol. 18 MACHEREY-NAGEL 05 / 2014, Rev. 01

6.2 Ordering information Product REF Pack of NucleoSpin Blood L Vacuum 740954.24 24 Liquid Proteinase K 740396 5 ml RNase A 740505.50 50 mg 740505 100 mg Starter Set Midi 740744 1 NucleoVac 96 Vacuum Manifold 740681 1 NucleoVac Vacuum Regulator 740641 1 Visit www.mn-net.com for more detailed product information. 6.3 Product use restriction / warranty NucleoSpin Blood L Vacuum kit components are intended, developed, designed, and sold FOR RESEARCH PURPOSES ONLY, except, however, any other function of the product being expressly described in original MACHEREY-NAGEL product leaflets. MACHEREY-NAGEL products are intended for GENERAL LABORATORY USE ONLY! MACHEREY-NAGEL products are suited for QUALIFIED PERSONNEL ONLY! MACHEREY-NAGEL products shall in any event only be used wearing adequate PROTECTIVE CLOTHING. For detailed information please refer to the respective Material Safety Data Sheet of the product! MACHEREY-NAGEL products shall exclusively be used in an ADEQUATE TEST ENVIRONMENT. MACHEREY-NAGEL does not assume any responsibility for damages due to improper application of our products in other fields of application. Application on the human body is STRICTLY FORBIDDEN. The respective user is liable for any and all damages resulting from such application. DNA/RNA/PROTEIN purification products of MACHEREY-NAGEL are suitable for IN- VITRO-USES ONLY! ONLY MACHEREY-NAGEL products specially labeled as IVD are also suitable for IN- VITRO-diagnostic use. Please pay attention to the package of the product. IN-VITROdiagnostic products are expressly marked as IVD on the packaging. IF THERE IS NO IVD SIGN, THE PRODUCT SHALL NOT BE SUITABLE FOR IN- VITRO-DIAGNOSTIC USE! MACHEREY-NAGEL 05/ 2014, Rev. 01 19

ALL OTHER PRODUCTS NOT LABELED AS IVD ARE NOT SUITED FOR ANY CLINICAL USE (INCLUDING, BUT NOT LIMITED TO DIAGNOSTIC, THERAPEUTIC AND/OR PROGNOSTIC USE). No claim or representations is intended for its use to identify any specific organism or for clinical use (included, but not limited to diagnostic, prognostic, therapeutic, or blood banking). It is rather in the responsibility of the user or - in any case of resale of the products - in the responsibility of the reseller to inspect and assure the use of the DNA/RNA/protein purification products of MACHEREY-NAGEL for a well-defined and specific application. MACHEREY-NAGEL shall only be responsible for the product specifications and the performance range of MN products according to the specifications of in-house quality control, product documentation and marketing material. This MACHEREY-NAGEL product is shipped with documentation stating specifications and other technical information. MACHEREY-NAGEL warrants to meet the stated specifications. MACHEREY-NAGEL s sole obligation and the customer s sole remedy is limited to replacement of products free of charge in the event products fail to perform as warranted. Supplementary reference is made to the general business terms and conditions of MACHEREY-NAGEL, which are printed on the price list. Please contact us if you wish to get an extra copy. There is no warranty for and MACHEREY-NAGEL is not liable for damages or defects arising in shipping and handling (transport insurance for customers excluded), or out of accident or improper or abnormal use of this product; defects in products or components not manufactured by MACHEREY-NAGEL, or damages resulting from such non-macherey-nagel components or products. MACHEREY-NAGEL makes no other warranty of any kind whatsoever, and SPECIFICALLY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES OF ANY KIND OR NATURE WHATSOEVER, DIRECTLY OR INDIRECTLY, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, AS TO THE SUITABILITY, REPRODUCTIVITY, DURABILITY, FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, CONDITION, OR ANY OTHER MATTER WITH RESPECT TO MACHEREY-NAGEL PRODUCTS. In no event shall MACHEREY-NAGEL be liable for claims for any other damages, whether direct, indirect, incidental, compensatory, foreseeable, consequential, or special (including but not limited to loss of use, revenue or profit), whether based upon warranty, contract, tort (including negligence) or strict liability arising in connection with the sale or the failure of MACHEREY-NAGEL products to perform in accordance with the stated specifications. This warranty is exclusive and MACHEREY-NAGEL makes no other warranty expressed or implied. The warranty provided herein and the data, specifications and descriptions of this MACHEREY-NAGEL product appearing in MACHEREY-NAGEL published catalogues and product literature are MACHEREY-NAGEL s sole representations concerning the product and warranty. No other statements or representations, written or oral, by MACHEREY-NAGEL s employees, agent or representatives, except written statements signed by a duly authorized officer of MACHEREY-NAGEL are authorized; they should not be relied upon by the customer and are not a part of the contract of sale or of this warranty. 20 MACHEREY-NAGEL 05 / 2014, Rev. 01

Product claims are subject to change. Therefore please contact our Technical Service Team for the most up-to-date information on MACHEREY-NAGEL products. You may also contact your local distributor for general scientific information. Applications mentioned in MACHEREY-NAGEL literature are provided for informational purposes only. MACHEREY-NAGEL does not warrant that all applications have been tested in MACHEREY-NAGEL laboratories using MACHEREY-NAGEL products. MACHEREY- NAGEL does not warrant the correctness of any of those applications. Last updated: 07 / 2010, Rev. 03 Please contact: MACHEREY-NAGEL GmbH & Co. KG Tel.: +49 24 21 969-270 e-mail: tech-bio@mn-net.com Trademarks / Disclaimer: NucleoSpin is a trademark of MACHEREY-NAGEL GmbH & Co. KG All used names and denotations can be brands, trademarks, or registered labels of their respective owner also if they are not special denotation. To mention products and brands is only a kind of information (i.e., it does not offend against trademarks and brands and can not be seen as a kind of recommendation or assessment). Regarding these products or services we can not grant any guarantees regarding selection, efficiency, or operation. MACHEREY-NAGEL 05/ 2014, Rev. 01 21