Ram Pump Water Filtration: Assessment and Filtration in Tres Hermanos Jonathan Lamano

Similar documents
National Science Content Standards: A: Science as Inquiry E: Science and Technology

Water Quality Parameters

Teacher s information - Lesson 3: Water disinfection

Development & Evaluation of Moringa-Enhanced Biosand Filtration For Use in Nomba, Mozambique

ESPAÑOL (Spanish) CONSUMER CONFIDENCE REPORT - WHAT IS IT? NEW MEXICO STATE UNIVERSITY PROVIDES GOOD SAFE DRINKING WATER

2012 Annual Drinking Water Quality Report Town of Chadbourn Water System Number:

ESPAÑOL (Spanish) CONSUMER CONFIDENCE REPORT - WHAT IS IT? NEW MEXICO STATE UNIVERSITY PROVIDES GOOD SAFE DRINKING WATER

2017 Water Quality Report

City of Ashland 2018 Water Quality Report

Village of Lockland, Ohio. What s On Tap?

TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 631. PUBLIC WATER SUPPLY OPERATION SUBCHAPTER 1. INTRODUCTION

Water Pollution. Chapter 20

TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 631. PUBLIC WATER SUPPLY OPERATION SUBCHAPTER 1. INTRODUCTION

INTRODUCTION: WHERE DOES OUR WATER COME FROM?

An Evaluation of Household Drinking Water Treatment Systems in Peru: The Table Filter and the Safe Water System

Village of Bridgeport. Consumer Confidence Report

BLOOMFIELD WATER CO. DRINKING WATER CONSUMER CONFIDENCE REPORT FOR 2011

TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 631. PUBLIC WATER SUPPLY OPERATION SUBCHAPTER 1. INTRODUCTION

The Water We Drink. Why is drinking water important to you? How much drinking water do we have? Where We Find the Earth's Water

A project to introduce filters for families with an arsenic contaminated water supply in the Municipality of Telica, Department of León

2016 Consumer Confidence Report (CCR)

2016 Annual Drinking Water Quality Report Naval Air Station Pensacola/Corry

Transforming Lives Through Discovery

MIT Household Water Treatment and Safe Storage Innovations

Town of Middleburg 2016 Annual Drinking Water Quality Report

customer confidence report

ANNUAL DRINKING WATER QUALITY REPORT 2017

2015 Annual Drinking Water Quality Report Wells College Water Department PO Box 500 Aurora, NY (Public Water Supply ID# )

AQUIFERS AND NON POINT SOURCE POLLUTION

City of Redding Water Utility 2006 Consumer Confidence Report

Puroxi Pure Water Global Inc. Shield 500/1000 Drinking Water System (DWS)

Quality of Rainwater From Rainwater Harvesting Systems in Sanaa. Nagib Ghaleb N. Mohammed, Civil Engineering Department, University of Bahrain

Nepal Project. Tim Harrison Meghan Smith Lincoln Lee Nat Paynter Jessie Hurd. Tansen. Nawalparasi. Parasi. Lumbini

CITY OF RONAN WATER DEPARTMENT Montana Public Water Supply ID number Water Quality Report

CITY OF GRANITE FALLS 2017 DRINKING WATER QUALITY REPORT

CONSUMER CONFIDENCE REPORT Montville Township Water Department PWSID# NJ Reporting Period - January 1, 2017 to December 31, 2017

2017 Annual Consumer Confidence Report Naval Station, Guantanamo Bay (NSGB)

2014 Consumer Confidence Report Data VIROQUA WATERWORKS, PWS ID:

2017 Consumer Confidence Report Data HOLMEN WATERWORKS, PWS ID:

Harford County Health Department Resource Protection Division

Annual Drinking Water Quality Report for Village of Lisle 2612 Liberty Street P.O. Box 729 Whitney Point, NY 13862

The Application of Flat Ultra-Filtration for Rainwater Reuse

Annual Drinking Water Quality Report Village of Chatham, NY 77 Main St., Chatham, NY (Public Water Supply ID# ) June 1, 2011

Village of Ada Water Department 2014 Drinking Water Quality Report

CITY OF BILLINGS 2018 WATER QUALITY REPORT

Evaluation of the Biosand Filter for Reducing Risks of Diarrheal Illness and Improving Drinking Water Quality in Communities of The Dominican Republic

ANNUAL DRINKING WATER QUALITY REPORT For FARMINGTON IL FOR THE PERIOD JANUARY 1 TO DECEMBER 31, 2017

Annual Drinking Water Quality Report for 2016 City of Taneytown

Clear Cambodia/charity: water Trip Report Svay Chrum Village, Svay Rieng Province, Cambodia

Water treatment. Why do we need to clean our water? Diseases carried by unclean water. Did you know? Did you know?

The Water We Drink. MINDEN WATER SYSTEM Public Water Supply ID: LA

2009 Annual Drinking Water Quality Report

2013ANNUAL DRINKING WATER QUALITY REPORT. Naval Air Station Corpus Christi D Street Corpus Christi, TX 78419

Farm Water Quality Considerations

Annual Drinking Water Quality Report

A Revolutionary Point-of-Use Water Filtration Device

2015 Annual Drinking Water Quality Report Naval Air Station Pensacola/Corry

City of Greenvil e Drinking Water Consumer Confidence Report For P a g e

Wastewater Treatment Works... The Basics

Annual Consumer Confidence Report for the Sonoma State University Drinking Water System 2008

2017 (CCR) Consumer Confidence Report January 1 st to December 31 st 2017

Why am I receiving this report?

2015 Consumer Confidence Report Data WHITING WATERWORKS, PWS ID:

Middlefield Village Water Department Drinking Water Consumer Confidence Report 2016

Drinking Water. Charles J. Devine, III, MD

Rock Springs Community - NTUA Annual Water Quality Report

2017 Annual Drinking Water Quality Report (Consumer Confidence Report)

DRINKING WATER QUALITY REPORT

2005 Annual Drinking Water Quality Report Currituck County Water PWS ID#

Misawa AB, JAPAN Drinking Water Consumer Confidence Report (CCR) 2016

2015 Consumer Confidence Report RAF Feltwell

Este informe contiene informacion muy importante sobre su agua potable. Traduzcalo o hable con alguien que lo entienda bien.

Pilot Study Report. Z-92 Uranium Treatment Process

VILLAGE OF GREENWICH STATE OF OHIO Administration Offices: 45 Main Street. Greenwich, Ohio (419)

U.S. NAVAL SUPPORT ACTIVITY NAPLES SUPPORT SITE GRICIGNANO 2015 DRINKING WATER CONSUMER CONFIDENCE REPORT

Transforming Lives Through Discovery

2014 Annual Drinking Water Quality Report Washington State University Pullman Drinking Water System (Public Water System #93200Q)

Village of Middleville 100 E. Main St. Middleville, MI WSSN# 4360 Consumer Confidence/Water Quality Report 2013

2017 Annual Drinking Water Quality Report Washington State University Pullman Drinking Water System (Public Water System #93200Q)

Workshops & Courses. Fully customizable training to support your WASH initiatives

CAMP LEMONNIER, DJIBOUTI 2016 DRINKING WATER CONSUMER CONFIDENCE REPORT

Water supplied by Marafiq does not meet the process requirements.

Valley View Mutual Water Co. Annual Drinking Water Quality Report 2016

CONSUMER CONFIDENCE REPORT

Misawa AB, JAPAN Drinking Water Consumer Confidence Report (CCR) 2017

What Determines water Quality? Well Maintenance Well water Testing AZ survey on individual systems water quality Final remarks

Annual Drinking Water Quality Report

2016 Columbus AFB Drinking Water Quality Report

Drinking Water Supply and

CAMP LEMONNIER, DJIBOUTI 2017 DRINKING WATER CONSUMER CONFIDENCE REPORT

2017 Consumer Confidence Report (CCR)

Greener Homes National Summit Rainwater Harvesting & Rain Garden Design and Performance Sustainable Water Management Session September

2017 Consumer Confidence Report Data MINERAL POINT WATERWORKS, PWS ID:

2015 Annual Drinking Water Quality Report Washington State University Pullman Drinking Water System (Public Water System #93200Q)

Annual Drinking Water Quality Report

2017 Water Quality Report. Public Water System Name: FARMERS WATER CO. Public Water System Numbers: 10048, 10049, 10213, 10414

Drinking Water Quality

Quality. Service. Value Drinking Water Report

Quality REPORT. annual. Presented By. Water Testing Performed in 2017 PWS ID#:

Southwood Community s Public Water Supply. Consumer Confidence Report 2015

Transcription:

Ram Pump Water Filtration: Assessment and Filtration in Tres Hermanos Jonathan Lamano Introduction In conjunction with Alternative Indigenous Development Foundation, Inc. (AIDFI) and Green Empowerment, the Northwestern Ram Pump team successfully installed a hydraulic ram pump system that services the village of Tres Hermanos on the island of Negros Occidental, Philippines. While the team completed the goal of delivering water to the village, further research was necessary in order to assess the quality of the water and any measures that could be taken to filter and purify the water if necessary. The further research consisted of comprehensive water quality analysis, consultations with the NGO partners and villagers concerning water filtration, and ultimately the design and prototyping of possible filtration options. Water Quality Assessment For analysis, two rounds of water samples were collected from chosen sampling locations. The water quality tests were conducted through the use of an Industrial Test Systems Water Quality Test Kit and two local laboratories, Negros Prawn Producers Marketing Cooperative, Inc. Analytical and Diagnostic Laboratory (NPPMC) in Bacolod and the LIPA Quality Control Center on a neighboring island. Initial water test samples were taken on June 25, 2010. Inorganic test results (Tables 1, 2, and 3) show that the water from the Anangue spring falls within the standards of potable water. Further analysis of the results from the separate sources reveals two trends (See Table 2 for sampling locations). The water sampled from the stream contains much higher concentrations of the inorganics tested for than the water captured in the ram pump system by the impounding tank, passed onto the catchment tank. However, as the water moves from the impounding to the catchment tank, there is an increase in concentration of inorganics. Both of these trends are also seen with the organic results; however the results also indicate that the concentrations of organics are higher than the standard for potable water. The trends of increasing values from the impounding tank to the catchment tank point to the possibility of a build-up of water contaminants in the ram pump system, which may stem from construction issues and may also become an increasing problem over time. Tests of Total and Thermotolerant (Fecal) Coliforms indicate that both the stream water and the water flowing through the ram pump system contain coliform concentrations larger than the standard for potable water. These higher concentrations of coliforms indicate that harmful pathogens may be present in the water. Although all of the samples do not pass the standard for potable water in the case of coliforms, the Impounding Tank/Spring Source and Catchment Tank samples do fall underneath the 100 MPN/100 ml advised by the EPA for water to be used for human contact. Furthermore, all samples fall under the EPA advised 2000 MPN/100 ml level for water for domestic use to undergo further treatment, such as filtration or boiling. Pathogenic organisms are usually present in water samples containing over 200 MPN/100 ml. Thus, the results show that the water collected and pumped to the community from the Anangue Spring Source, through the ram pump is below levels containing pathogenic organisms, compared to the stream source whose water testing results point towards the possibility of pathogenic organisms in the water. A second water sampling was taken on July 19, 2010 in order to more fully analyze the trend of increasing values along the ram pump system, however the results (See Table 4) returned did not provide further insight to the water quality assessment, as the unusually high results across a majority of the samples indicate possible invalidity of the test. During the construction of the ram pump, some relevant observations were made regarding water quality. The first observed occurrence was the increased flow to the adjacent Anangue Catchment tank, indicating that as the water was dammed by the newly constructed impounding tank, the water level of the spring source was pushed farther back. The water may have been forced into areas of greater contamination or may even have caused new water flow into unknown areas. Another observation was the increased amount of water collected in the ram pump systems catchment tanks after rainfalls, indicating that the source may not be a natural spring, but instead may be influenced by outside sources, such as rain. This observation may explain one mode for contaminants to enter the water.

Water Filtration Options After completion of the water quality assessments, the focus of research turned to methods of water filtration for use in rural areas. Villagers currently filter their water through clean clothing or boil water, although the latter option is not preferred since it consumes precious fuel resources. The filtration options considered included an in-line filtration system, commercial filters, solar water disinfection (SODIS), household biosand filtration systems, porous ceramic filters, and ceramic/biosand combination filters. Filter Option In-Line Filtration System Commercial Filters (See Figures 1 and 2) SODIS Household Biosand Filtration Systems (See Figures 3, 4, and 5) Porous Ceramic Filtration (See Figure 6) Porous Ceramic/Biosand Filtration Combinations (See Figures 7 and 8) Assessment Discussed with AIDFI, but ultimately decided against due to the necessary appointment of a local water quality technician, who would assume responsibility for the water supply of the entire village population. Repair of the system would also require more tools and expertise. AIDFI would rather leave water quality as a family responsibility. Not recommended. Commercial filters were used during the trip, yet for the average rural family, they are too expensive to purchase. Moreover, they are difficult to transport from the markets where they are sold and in the occurrence that they break down (sometimes frequently) or need replacement filters, the parts are expensive and difficult to attain. Not recommended. Method currently implemented by some rural villages due to its ease of operation. PET and glass bottles are easily accessible even in the rural villages. Currently, Red Cross volunteers and DOD volunteers are spreading knowledge of the water purification method. This method is highly recommended for use in the rural Philippines. No household biosand filtration systems were encountered in the Philippines, however, all of the necessary components of the filter- cement or plastic buckets, gravel, and sand - are easily accessible and even plentiful in the rural areas. A biosand filter was constructed at Northwestern and tested (See Table 5). Biosand filtration systems are highly recommended. The only porous ceramic filters encountered in the Philippines were commercially made filters. Clay sources were abundant in some rural areas, however, no ovens for clay firing were spotted, nor did any rural Filipinos report pottery experience, as they mainly work with weaving bamboo baskets. Porous ceramic filters were constructed at Northwestern and tested (See Table 6). However, even with the expertise and aid of a professional potter at ARTica Studios, the filters were fragile and difficult to construct. Therefore, they are not highly recommended for Filipino rural areas. The combination of the two filters was hypothesized to facilitate greater overall purification and filtration. The filter combinations were prototyped and tested at Northwestern. However, for the same reasons as the porous ceramic filters, they cannot be highly recommended for communities in the rural Philippines. Conclusion and Future Research After water quality assessments indicated the need for water filtration in order to provide the village of Tres Hermanos with safe potable water, filtration methods were assessed and tested. From the filtration options assessed, the most highly recommended methods included SODIS and household biosand filtration, since they are low-cost, can be made from easily accessible materials, and effectively purify water. Since the second water assessment turned out inconclusive, instructions were left with AIDFI to conduct a follow-up water assessment and to forward the results to Northwestern. Furthermore, future research may be made into possible water filtration systems involving bamboo woven baskets and coconut husks, since these materials are easily accessible and abundant to rural Filipinos.

Tables Table 1: Initial Sampling Water Quality Test Kit 06/25/10 Organic and Inorganic Sample: Anangue Impounding Tank (Spring Source) Maximum EPA Test Contaminant Level for Result Potable Water (MCL) ph NA 6.0 Total Alkalinity (ppm) NA 100 Total Chlorine (ppm) 4.0 0.0 Total Hardness (ppm) NA 0.0 Free Chlorine (ppm) 4.0 0.0 Chloride (ppm) 250 0.0 Sulfate (ppm) 250 0.0 Total Nitrate and Nitrite (ppm) 10 0.0 Copper ( (ppm) 1.3 0.0 Iron ( (ppm) 0.3 0.0 Lead NA Negative Pesticide NA Negative Table 2: Initial Sampling NPPMC Laboratory 06/25/10 Organic and Inorganic Samples: Stream, Anangue Impounding Tank (Spring Source), and Catchment Tank Sample 2: Test Anangue Sample 3: Standard Sample 1: Impounding Catchment Values Stream Tank/Spring Tank Source Total Dissolved Solids (ppm) < 500 69 34 66 Iron (ppm) 1 0.4 < 0.2 < 0.2 Sulfate (ppm) < 250 79 39 51 Nitrate (ppm) < 50 0.967 0.226 0.419 Phosphate (ppm) NA 0.084 0.02 0.052 Total Coliform (MPN/100mL) < 1.1 > 1,600 13 23 Thermotolerant (Fecal) Coliform (MPN/100mL) < 1.1 300 8 13 Table 3: Initial Sampling LIPA Quality Control Center 06/25/10 Inorganic Only Sample: Anangue Impounding Tank (Spring Source) Test MCL Result Mercury (ppm) 0.002 < 0.001 Lead (ppm) 0.015 < 0.01 Arsenic (ppm) 0.010 < 0.003

Table 4: Second Sampling NPPMC Laboratory 07/19/10 Organics Only Samples: Boiled Water, Impounding Tank, Catchment Tank, Tres Hermanos Pipe, Tap Stand, Household Water Container, Ceramic Filter, and Stream Sample Standard Maximum Values Total Coliform Result (MPN (most probable number of colonies) /100mL) Thermotolerant (Fecal) Coliform Result (MPN/100mL) Boiled Water < 1.1 < 2.0 < 2.0 Impounding Tank < 1.1 > 1,600 > 1,600 Catchment Tank < 1.1 > 1,600 > 1,600 Tres Hermanos Pipe < 1.1 > 1,600 > 1,600 Tap Stand < 1.1 900 130 Household Container < 1.1 > 1,600 > 1,600 Ceramic Filter < 1.1 > 1,600 > 1,600 Stream < 1.1 > 1,600 > 1,600 Table 5: Biosand Particle Filtration Test Test run using fluorescent particles of size approximately 5 micrometers to mimic water contaminants Time of Sample Collection Concentration (counts/ml) 7:12 P.M (Initial Concentration) 13,728,726.64 7:32 P.M (20 minute interval) 1,371,209.95 8:12 P.M (1 hour interval) 1,790,547.69 8:42 P.M (1 hour and 30 minute interval) 21,594.824 Table 6: Porous Ceramic Filtration Results Filter Prototype Maximum Capacity (ml) Flow Rate (ml/min) Plate 800 0.824 Pot 13,500 6.579 Cylinder 23,000 0.870

Figures Figure 3: Grades of Sand and Gravel Used to Construct Biosand Filters Figure 1: Megafresh Commercial Filter Used During the Project Duration Figure 2: Commercial Hand Pump Tested in the Philippines Figure 4: Household Biosand Filtration System

Figure 5: Testing the Biosand Filtration System Figure 7: Combination Porous Ceramic and Biosand Filter Figure 8: Alternate Configuration of Porous Ceramic and Biosand Combination Figure 6: Configurations of Porous Ceramic Filters

Reference "Ground Water & Drinking Water Drinking Water US EPA." EPA Office of Water Home Water US EPA. Web. 07 Oct. 2010. <http://water.epa.gov/drink/index.cfm>.