Hazardous area classifications and protection methods

Similar documents
Proline Prosonic Flow B 200 For reliable biogas flow measurement without compromise

The following chart lists the 3 classes and 2 divisions defined within National Electric Code 500 (NEC-500) for hazardous area installations.

Turbimax CUE25 / CUE26

Flowfit CCA250. Technical Information. Flow assembly for chlorine and ph/orp sensors

Proline Promag 800 The battery-powered flowmeter for the water industry. Long-term reliability long-term operation up to 15 years

Products Solutions Services. Field Xpert SFX350, SFX370 Rugged Handheld for Mobile Plant Asset Management

Calibration services Meeting our customers needs in the U.S.

Products Solutions Services. End User Academy Online course catalog

Turbimax CUE25 / CUE26

NEMA Enclosure Types

Advancing vortex durability and intelligence for energy measurements

Hazardous-Area Classification Methods and Equipment

SafeSite LED RTO Area Light - UL844. for Indoor and Outdoor Industrial Applications #

Preventing Disasters Through Intrinsic Safety The essentials behind an essential practice

Intrinsic Safety & Hazardous Areas

A Guide to Selecting Motors for Hazardous Locations

Protection methods, containment, segregation, and prevention

Industry Standards & Definitions

Products Solutions Services. Successful Tank Farm and Terminal Management It starts with safety, efficiency and simplicity

Certificate of Compliance

EXPLOSION-PROOF MOTORS

LED LIGHTING OPTIONS FOR HAZARDOUS LOCATIONS MARCH 30, 2017

SafeSite LED Wallpack - UL 844. for Indoor and Outdoor Hazardous Applications

Certificate of Compliance

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

The Benefits of Steam Tracing vs. Electric Tracing. Written by Horst Thieme, PE, James R. Risko and the Fluid Controls Institute Steam Trap Section

- Laboratory Report Explosibility of Dust Clouds. Project: Holi Color Powder/Gulal

Amendment A National Electric Code

SECTION ULTRASONIC BIOGAS FLOW MEASURING SYSTEM

Thermocouple T53, T54 and T55

ATEX The legislation ATEX 94/9/EC (95) European Directive 23 March Mandatory 30/6/2003. Fläkt Woods Group

Hazardous Area Requirements (with a case study) Presenters: Dan Alecu & Lovenah Galchoolah

Material Safety Data Sheet High Impact Polystyrene

RP 8.0: DOGHOUSE ELECTRICAL CLASSIFICATION. A Recommended Practice (RP) for the Canadian Land-Based Drilling Industry

Low Voltage Hazardous Area Motors. Motors Energy Automation Coatings

SAFETY DATA SHEET Material Name:

Spray Booth Guideline

MATERIAL SAFETY DATA SHEET

Certificate of Compliance

Technical News. Introductory guide to hazardous areas in Australia and New Zealand

50 Watt Low Bay LED Light Fixture - Outdoor Rated - IP67-4,333 Lumens

vapor control systems Quality, Dependability, Service. Reputation Built on Valve Concepts, Inc. com A Cashco, Inc.

Certificate of Compliance

Accreditation Scope by Certification Test Order

What to You Need to Know When Limited Production Certification is Your Hazardous Locations Compliance Strategy

Certificate of Compliance

IntePlus Films Safety Data Sheet

Installation, Operation and Maintenance Instructions 3.19 [81.0] 0.43 [11.0] 0.94 [23.9].29 THRU 0.43 [11.0] 1.42 [36.0] 4.80 [121.8] 1.89 [47.

SafeSite LED High Bay High Efficiency - UL 844. for Indoor and Outdoor Hazardous Applications

Material Safety Data Sheet Issue Date: February 15, 2018

Six Keys to Managing Workplace Electrical Safety

IntePlus Films Safety Data Sheet

SECTION Inline ULTRASONIC FLOW METERS

SECTION PACKAGED, SUBMERSIBLE SEWERAGE PUMP UNITS

Document id : Issue date : 2007/02/14 Version : Supersedes date : 2007/01/24

CM4120 Safety Orientation. Spring? Semester 2015

Product identifier Product Name ZyBar Relevant identified uses of the substance or mixture and uses advised against

Introduction to Fire Protection Systems

SECTION 2 - COMPOSITION AND INGREDIENT INFORMATION Under normal use, this battery dphi not expose the user to hazardous ingredients.

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

Elect rical rical Sol utions for Solutions the for Pul the p and Pul Paper p and Indu Paper Indu ry Electrical Division

Certificate of Compliance

Product Distributed by Rio Grande SDS access on web: Safety Data Sheet

PHYSICAL AND CHEMICAL PROPERTIES

Fuel Sources. Gases Liquids/vapours Chemicals and Solids

MATERIAL SAFETY DATA SHEET

Safety Data Sheet (SDS) OSHA HazCom Standard 29 CFR (g) and GHS Rev 03.

Product No: BiologiQ AG201090, AG202080, AG203070, AG204060, AG Revision Date: 08 December 2016

Electrical Specifications. Dielectric Withstanding Voltage 200V CSR2010 1W 200V ±100 ppm/ºc (1)

Compiled by: Figure 2: Fire triangle. Successfully suppressing or separating one or more of these three components can avoid a fire or explosion.

SHOWER WALLS S.A. DE C.V. FIRE TEST REPORT

Silicone Conformal Coating 422B Technical Data Sheet 422B-Aerosol

Certificate of Compliance

ATEX SOLUTONS FROM AERZEN

BASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 11/10/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

GHS SAFETY DATA SHEET

SmartScanTM. SolidScan You Can Measure the Solid Benefits. Ultrasonic Continuous Level Measurement of Liquids and Solids

1.1 Product Identifier Material Name: Apiezon Wax W40.

1.1 Product Identifier Material Name: Apiezon Wax W100.

GAF Safety Data Sheet SDS # 1094 SDS Date: July 2016

Testing Agencies & the Electrical Inspector

Installation of CSST Gas Piping Systems

TITE A SEAL COND ANA

Safety Data Sheet acc. to OSHA HCS & WHMIS

Material Safety Data Sheet

The Basics of Combustible Dust

Material Safety Data Sheet

Safety Data Sheet (SDS) OSHA HazCom Standard 29 CFR (g) and GHS Rev 03.

MATERIAL SAFETY DATA SHEET

Practical Issues with Marginally Explosible Dusts: Evaluating the Real Hazard. Samuel A. Rodgers, Honeywell and Erdem A.

The batteries are articles and are not subject to the OSHA Hazard Communication Standard Requirement as shown in paragraph (b)(6)(v) of

Electrical Specifications Electrical Specifications Maximum Working. Maximum Overload Voltage

Safety Data Sheet (GHS/WHMIS 2015)

vapor control systems Quality, Dependability, Service. Reputation Built on Valve Concepts, Inc. com A Cashco, Inc.

MATERIAL STANDARD FOR ELECTRICAL HEAT TRACING ORIGINAL EDITION JAN. 1996

Safety data sheet for AIREX PXc & PXw

2. Is there a potentially explosive atmosphere: Yes No (If the answer is "no", no further information is required!)

Best Practices for Flow Calibration Management

Address: 401 Truck Haven Road, East Peoria, Illinois Emergency Phone:

Transcription:

White Paper Hazardous area classifications and protection methods Keith Riley Executive Summary A paper which describes what the hazardous area classifications are and what specific protection methods truly mean. It will demystify the common third party approvals. This paper will also include how and when you can use a specific approval rating as well as what is and is not required to be supplied. About the Author Keith Riley has been a Product Business Manager with Endress+Hauser since April 2008. Prior to this, he has been a Product Manager and Regional Sales Manager with L.J. Star Incorporated as well as a Product Manager for Penberthy (Tyco Valves). Overall, he has over 15 years of sales, marketing and application experience in the process industry. CP 974F/24/EN/02.10 White Paper US/INDD CS

Class who? Division where? Group what? This paper is intended to demystify third party approvals. Included is information addressing what the common hazardous area classifications are for a facility and what a specific protection method truly means. It also includes how and when you can use a certain approval rating as well as what the instrument supplier is and is not required to supply. First, let s begin with definitions of the various Class, Divisions and Groups you will likely encounter. Class: A type of hazardous location segmented and defined by the materials present. I II An area in which flammable gases or vapors may be present in the air in sufficient quantities to be explosive or ignitable. An area in which combustible dust may be present in sufficient quantities to be explosive. III An area in which easily ignitable fibers or flyings are present. These do not have to be airborne but may also accumulate on or near the instrument. Division: This is the condition under which the hazard identified by the Class rating is present. 1 Normally present. You can expect the hazard to be present in sufficient quantities to be explosive or ignitable every day during normal operation. 2 Abnormally present. This identifies a situation where the hazardous material would typically be confined in a container or system. However in the event of a Group: failure or accidental rupture it would be released into the area in quantities sufficient to be explosive or ignitable. Categorize and identify the nature of the hazardous materials that could be present in the hazardous location that has been identified. A, B, C & D Refer to gases and vapors covered under Class I locations. The segmentation between the groups is based upon ignition temperature, explosion pressure and other flammable characteristics. Group A Acetylene Group B Hydrogen and similar materials Group C Ether, Ethylene and similar materials Group D Hydrocarbons, fuels and solvents such as propane E, F & G Are used to segment the various hazardous substances in a Class II area. The groupings are based upon ignition temperature and conductivity of the material in question. Group E Metal dusts (conductive and explosive) such as aluminum and magnesium Group F Carbon dusts (some conductive and all explosive) such as carbon black, coal and coke Group G Grain, plastic or chemical dusts (explosive) such as flour or starch These are the common hazardous area classifications in the United States. With the advent of globalization, you may see requests for slightly different classifications. You may encounter references to Class, Zone and Group versus Class, Division and Group. These two approaches to hazardous area classification are not synonymous. In fact, in most cases there is no direct cross reference between them. Typically, the use of Class, Zone, Group is the European method of hazardous area classification. However, recent changes in the United States acknowledge the use of the Class, Zone, Group method. The classification of Class, Division, Group is based upon Article 500 of the NEC (National Electric Code). The U.S. version of Class, Zone, Group is based upon Article 505. While technically acceptable, the use of Class, Zone, Group has not been widely embraced by the United States. The next section will address the definition of and differences between the most common protection methods utilized in the United States; XP, IS, NI and DIP. Is there more than one protection method for instruments that can be utilized for a given hazardous area classification? In the previous section we defined common hazardous area classifications. These in turn are directly related to the instrument s hazardous area rating. To be more specific the physical area of a facility is given a hazardous area classification based upon environmental conditions. The instrument is provided with a hazardous area rating. The rating of the instrument must be equal to or better than the classification for the area. This section will focus on two of the various protection methods available. It is important to understand the concept behind each as the protection method utilized determines a number of very important factors. 1. How the instrument must be installed 2. If any additional third party equipment is required to meet the designated rating 3. What information must accompany the instrument from the manufacturer Let s start with the two Division 1 protection methods people are most familiar with; explosion proof and intrinsically safe. 2

Explosion Proof (US acronym XP): This protection method is based upon a containment strategy. We are not trying to prevent contact between the hazardous environment and the electrical energy of the instrument. It is assumed that at some point this is inevitable. Instead the intention is to insure the system is capable of containing and controlling a subsequent explosion. This is accomplished through a combination of the physical strength of the enclosure and proper sealing procedures. Sealing procedures either prevent the escape of flames and/or hot gases or direct the same to controlled flame paths. These flame paths help relieve pressure from the explosion and allow the gases time to cool before they reach the atmosphere. The explosion proof protection method is intended for use in a Class I, Division 1, Group A thru D hazardous area classifications. When dealing with an explosion proof rated device, the use of proper wiring practices is automatically implied. Specifically this means following the standards and procedures outlined in NEC [National Electric Code] Article 501. This includes, but is not limited to, the use of explosion proof rated conduit and a flame path sealoff installed within 18 of the instrument enclosure. Since these standard wiring practices must be employed for all XP rated instruments, manufacturer supplied control drawings detailing proper installation procedures are not required. The inclusion of control drawings is at the manufacturers discretion. Intrinsically Safe (US acronym IS): This protection method is based upon the concept of energy limitation. Here again it is assumed contact between the hazardous environment and the energy of the instrument is inevitable. Consequently, the strategy is to prevent ignition of the hazardous environment by limiting the amount of energy allowed to enter the hazardous area. This includes direct or stored electrical energy as well as heat. The intrinsically safe protection method is intended for Class I, II, III; Division 1; Groups A thru G hazardous area classifications. The second significant difference between XP and IS protection methods is the use of Associated Apparatus (approved third party equipment). An associated apparatus is a device that regulates the voltage and current available to the intrinsically safe rated instrument. Every intrinsically safe rated instrument will utilize an associated apparatus. In most cases the associated apparatus is an intrinsically safe barrier that is physically located outside of the hazardous area. One exception to the location restriction would be if the associated apparatus is mounted in an explosion proof rated enclosure. This could allow the associated apparatus to be located inside the hazardous area with approval from the proper authoritative body. For an intrinsically safe rated device, a manufacturer supplied control drawing is mandatory. The instrument s intrinsically safe rating is dependent upon it being properly connected to the associated apparatus. Since correct wiring procedures can vary between instruments, instrument specific instructions must be provided. Based upon what you have just read you should now know the answer to our question. Is there more than one protection method for instruments that can be utilized for a given hazardous location classification? The answer is Yes! If you have an area classified as Class I, Division 1, Groups A thru D, it is possible to employ either an explosion proof or intrinsically safe rated instrument. Assuming all of the proper wiring practices and/or associated apparatus are utilized, either protection method would be allowed and considered equally safe. The choice of which protection method to use will rest with the facility and their preferred method of installation. Do Not Make the Mistake of Thinking All XP and IS Rated Devices are Interchangeable! The applicability of protection methods is area classification specific. If the area classification in question was anything other than Class I, an XP rated instrument could not be used but an IS rated instrument could. In the next section, we will address two of the remaining protection methods employed for instrumentation, Dust Ignition Proof (DIP) and Non-Incendive (NI). How does a Dust Ignition Proof (DIP) protection method differ from Explosion Proof (XP)? What is the Non- Incendive (NI) or Non- Incendive Field Wiring Apparatus (NIFW) protection method and how does it differ from XP or IS? In this section we will answer these questions and discuss where and how you use a DIP, NI or NIFW protection method. You will also see what differentiates each from the more common XP and IS protection methods. Dust Ignition Proof (US acronym DIP): The primary difference between DIP and XP is the type of flammable or combustible material involved. Explosion Proof rated instruments are strictly for Class I, (gases or vapors) hazardous areas. Dust Ignition Proof rated instruments are suitable for Class II, III; (dust, fibers or flyings) Division 1 hazardous areas. Similar to XP, the DIP protection method is based upon a physical containment strategy. However, instead of containing/controlling an explosion within the instrument housing, DIP is focused on containing the electrical and thermal energy within the housing in such a way as to preclude contact with the hazardous atmosphere and prevent ignition. This is accomplished primarily through the housing seals. When dealing with a Dust Ignition Proof rated device, the use of proper wiring practices is automatically implied. Specifically this means following the standards and procedures outlined in NEC (National Electric Code) Article 502 for Class II locations or Article 503 for Class III locations. Since these standard wiring 3

practices must be employed, manufacturer supplied control drawings are not required for DIP rated instruments. The inclusion of control drawings is at the manufacturer s discretion. Non-Incendive and Non-Incendive Field Wiring Apparatus (US acronyms NI and NIFW): Both NI and NIFW are strictly Division 2 protection methods. They share the common feature that any electrical or thermal energy contained within the instrument s circuits is incapable of igniting the combustible material in the hazardous area under normal* operating conditions. The instrument housing is not intended to exclude the flammable atmosphere or contain an explosion for either protection method. This means the housing and wiring requirements are less stringent and costly than for Division 1 protection methods. This is where the similarity between NI and NIFW ends. A Non-Incendive rating means that under normal* conditions the instruments circuits are incapable of causing ignition of the hazardous atmosphere. This is accomplished without any special wiring consideration assuming the manufacturer s published specifications are met. Consequently, control drawings are not required for NI rated instruments. A Non-Incendive Field Wiring Apparatus rating means under normal* conditions the instrument s circuits are incapable of causing ignition of the hazardous atmosphere. However, a NIFW rated instrument is dependent upon an Associated Non-Incendive Field Wiring Apparatus [ANIFW]. This is a third party device that controls the current and voltage available to the instrument. In most cases an ANFIW rated power supply located outside of the hazardous area is used for this purpose. An ANFIW power supply is different from and less expensive than an intrinsically safe barrier used for IS rated instruments. As you can probably guess since the instruments NIFW rating is dependent upon an ANFIW rated device, control drawings are mandatory. Let s review our questions from the beginning of this section. How does a DIP protection method differ from a XP protection method? 1. DIP is a valid protection method for Class II & III (dust, fibers, any flyings] hazardous area classifications while XP is a valid protection method for Class I (gases and vapors) hazardous area classification. 2. A DIP rated instrument contains the electrical and thermal energy within the housing in such a way as to preclude contact with the hazardous area and prevent ignition. A XP rated instrument assumes contact with the hazardous area is inevitable and is designed to contain and/or control the subsequent explosion within the housing. How does a NI or NIFW protection method differ from XP or IS? 1. NI and NIFW protection methods are limited in use to areas with a Division 2 classification. Both XP and IS protection methods are primarily intended for use in areas with a Division 1 classification. 2. The NI wiring requirements per NEC Article 501 for a Class I, Division 2 hazardous area classification are less stringent and less expensive than for a Class I, Division 1 hazardous area classification. Example: A conduit seal within 18 inches of the enclosure is not required. Now let s look at two additional questions that many of you are probably asking. Why would someone use a NI or NIFW protection method versus XP or IS? The primary reason is cost! If the physical area in question has been designated with a Class I, Division 2 classification the potential savings to the facility from using a NI or NIFW rated instrument in terms of reduced wiring and installation cost can be significant. Isn t a NI or NIFW protection method less safe than a XP or IS? NO! They are dealing with different area classifications (Class I, Division 2 versus Class I, Division 1). The protection methods for Division 1 and Division 2 classifications are simply based upon a different set of operational parameters and probabilities that dictate different strategies to maintain a safe environment. This in turn affects the associated cost, not the overall safety. The next section is common to all of the protection methods we have discussed: Temperature Classifications and Temperature Class Ratings. This will then be followed by frequently asked questions and a short discussion on Nationally Recognized Testing Laboratories. Temperature Classifications/ Temperature Class Ratings By now you can guess that Temperature Classifications are given to a hazardous area and Temperature Class Ratings are applied to instruments. Temperature Classifications and Temperature Class Ratings are utilized for all hazardous areas and protection methods. This is the manner used to quantify the level of thermal energy allowed in the area or produced by the instrument. Temperature Classification: This classification identifies the minimum ignition temperature threshold for the hazardous area. In other words, in order for the explosive or combustible environment to ignite, it would need to be subjected to a temperature in excess of this value. The values applied to this classification run from T1 to T6. A classification of T1 means the minimum ignition temperature is >842 F (450 C). A classification of T6 means the minimum ignition temperature is >185 F (85 C). Temperature Class Rating: This rating identifies the maximum surface temperature the instrument will produce at a given ambient environmental temperature (typically 104 F or 40 C). You may find higher ambient temperatures referenced in a rating but they need to be clearly identified in the instrument markings or certificate. The same T1 thru T6 values are utilized for Temperature Class Ratings as for Temperature Classifications. A rating of T1 means the maximum surface temperature generated by the instrument at 104 F or 40 C is 842 F or 450 C. A rating of T6 means the maximum surface temperature generated for the instrument is 185 F (85 C). Temperature Classification / Rating Area Min Ignition Temperature F ( C) Instrument Max Surface Temp F ( C) T1 >842 (450) 842 (450) T2 >572 (300) 572 (300) T3 >392 (200) 392 (200) T4 >275 (135) 275 (135) T5 >212 (100) 212 (100) T6 >185 (85) 185 (85) 4 *in this context normal means with no circuitry component failure but possibly with user wiring errors.

Obviously a Temperature Class Rating of T6 means the instrument produces less thermal energy or does a better job of dissipating generated heat than does a rating of T1. The Temperature Class Rating of the instrument must be equal to or better than that Temperature Classification for the hazardous area. (Example: Area Classification = T4 / Instrument Rating must be T4 thru T6) Questions? At this point there is one question that seems to be on everyone s mind. Can a customer use a Division 1 rated instrument in a hazardous area with a Division 2 classification? Yes you can. Assuming the associated Class and Temperature rating for the instrument are appropriate for the area, you can always use an instrument with a more stringent Division rating than required for the area. However, if you use a Division 1 rated instrument it must always be installed according to Division 1 wiring procedures, regardless of the hazardous area division classification. Doing so is typically more involved and will add to the overall expense of the installation versus using a Division 2 rated instrument. Nationally Recognized Testing Laboratories (NRTL) The subject of NRTLs (Nationally Recognized Testing Laboratories) has been a growing issue with respect to instrument ratings in recent years. You have all heard of the typical test agencies such as FM, UL and CSA. In the past the choice between which test agency to use was largely based upon customer or market preference. While this practice may still exist in small pockets, the trend is changing. You may have noticed there has been no reference to a specific test agency up to this point. That is because OSHA makes no distinction between NRTLs. The test procedures are harmonized. Every NRTL tests to the same standards to evaluate an instrument for a given approval rating. As long as an agency is classified as a NRTL and testing within its scope of registration, they are considered equal. The NRTL mark (FM, UL, etc.) is not the instrument approval rating. The designation of Class, Division and Group is the approval rating. For this reason all reference to a specific test agency may one day disappear from a manufacturer s literature. It could be replaced with a general statement that the instrument is NRTL certified to Class [X], Division [Y], Group [Z]. The only place the NRTL mark would be located is the official certificate the individual agency would issue. While some people may equate the move to NRTLs to deregulation and sacrificing safety, nothing could be farther from the truth. All of the controls that have always been in place remain. What the change has and will continue to do is instill a greater sense of competition among test agencies. This ultimately benefits both the manufacturer and the customer. For further information on the subject visit the OSHA website at: www.osha.gov/dts/ otpca/nrtl/index.html. Conclusion Proper application of third party approved instruments can be confusing. Hopefully the information included within this paper has shed light on the subject. Ultimately your instrument manufacturer of choice should be able to answer any questions you may have regarding the proper use and installation of their device. References www.osha.gov National Electric Code - 2008 Edition NFPA 70th 5

ISO 9001:2000 Certified USA Canada Mexico International 08.07/SCUSA Endress+Hauser, Inc. 2350 Endress Place Greenwood, IN 46143 Tel: 317-535-7138 Sales: 888-ENDRESS (888-363-7377) Service: 800-642-8737 Fax: 317-535-8498 inquiry@us.endress.com www.us.endress.com Endress+Hauser Canada 1075 Sutton Drive Burlington, ON L7L 5Z8 Tel: 905-681-9292 800-668-3199 Fax: 905-681-9444 info@ca.endress.com www.ca.endress.com Endress+Hauser México S.A. de C.V. Fernando Montes de Oca 21 Edificio A Piso 3 Fracc. Industrial San Nicolás 54030 Tlalnepantla de Baz Estado de México México Tel: +52 55 5321 2080 Fax: +52 55 5321 2099 eh.mexico@mx.endress.com www.mx.endress.com For international locations visit: www.endress.com/worldwide CP 974F/24/EN/02.10 White Paper US/INDD CS