REPORT HOLDER: FEROOF CO., LTD SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO SOUTH KOREA EVALUATION SUBJECT:

Similar documents
DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: ROOF PANELS REPORT HOLDER: ROSER CO., LTD.

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES REPORT HOLDER: TEFUTE BUILDING MATERIALS COMPANY, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF TILES REPORT HOLDER: GERARD ROOFING TECHNOLOGIES EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOF PANELS REPORT HOLDER: ONDULINE NORTH AMERICA, INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: CERAMICA LA ESCANDELLA, S.A.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: BORAL ROOFING LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BARTILE ROOFS, INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: ENVIRONMENTALLY SAFE PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: KMEW CO., LTD. EVALUATION SUBJECT:

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: KINGSPAN LIGHT + AIR LLC

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS DIVISION: SIDING REPORT HOLDER: VM ZINC

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: SKYCO SKYLIGHTS 2995 AIRWAY AVENUE, SUITE B COSTA MESA, CALIFORNIA 92626

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: TEJAS BORJA USA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KAYCAN LTD.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: DERBY BUILDING PRODUCTS INCORPORATED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FACED PANELS REPORT HOLDER: MEXALIT INDUSTRIAL, S.A. DE C.V.

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: RIDGE VENTS REPORT HOLDER: VERSCENE, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: BORAL COMPOSITES, INC.

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

ICC-ES Evaluation Report. ESR-3297 Reissued March 1, 2013 This report is subject to renewal May 1, 2014.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER:

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

REPORT HOLDER: MASTER MARK PLASTICS PRODUCTS 210 AMPE DRIVE PAYNESVILLE, MINNESOTA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC

ESR-3284 Reissued August 1, 2011 This report is subject to renewal August 1, 2013.

ESR-2015P* Reissued April 2014 This report is subject to renewal April 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: MITEK USA, INC.

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: SUZHOU HONGLY HARDWARE CO., LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: PAREX USA, INC.

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: ULTRALOX 2955 LONE OAK DRIVE, SUITE 180 EAGAN, MINNESOTA 55121

DIVISION: MASONRY SECTION: MANUFACTURED BRICK MASONRY SECTION: MANUFACTURED STONE MASONRY REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC. EVALUATION SUBJECT:

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING REPORT HOLDER: SILCA SYSTEM

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: REFLECTIX INCORPORATED

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

REPORT HOLDER: SOPREMA, INC. 310 QUADRAL DRIVE WADSWORTH, OHIO EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: BOSTITCH FASTENING SYSTEMS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING SECTION: PLASTIC RAILINGS REPORT HOLDER:

REPORT HOLDER: GEORGIA PACIFIC GYPSUM LLC 2861 MILLER ROAD DECATUR, GEORGIA EVALUATION SUBJECT: DENSELEMENT BARRIER SYSTEM

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC.

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: AKRON PRODUCTS COMPANY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER: FYPON, LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PRODEMA USA INC. EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

REPORT HOLDER: BASF CORPORATION EVALUATION SUBJECT: MASTERSEAL AWB 660 I VAPOR RETARDER, AIR AND WATER-RESISTIVE BARRIER AND FLEXIBLE FLASHING

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL FLOOR DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: DRYVIT SYSTEMS, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: ASSOCIATED MATERIALS, INC.

EMPIRE SHAKE, EMPIRE PLUS SHAKE, AND EMPIRE SLATE POLYOLEFIN COMPOSITE TILES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BORAL ROOFING EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: COVESTRO, LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: METALS SECTION: METAL FASTENINGS DIVISION: FINISHES SECTION: FASTENERS REPORT HOLDER: HILTI, INC.

REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC. EVALUATION SUBJECT: GRABBER FASTENERS FOR USG STRUCTURAL PANELS

Joint Evaluation Report ICC-ES (800) (562)

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC RAILINGS SECTION: STRUCTURAL PLASTICS REPORT HOLDER:

Transcription:

0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3331 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 31 16 METAL SHINGLES SECTION: 07 32 19 METAL ROOF TILES SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FEROOF CO., LTD. 565 1 SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO 40048 SOUTH KOREA EVALUATION SUBJECT: STEEL ROOFING PANELS: VENETO I, VENETO II, RIO, RIO EZ, DIVA, WOOD, ZISSEN AND SLATE Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report ESR-3331 Reissued September 2017 This report is subject to renewal September 2018. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 31 16 Metal Shingles Section: 07 32 19 Metal Roof Tiles Section: 07 41 13 Metal Roof Panels REPORT HOLDER: FEROOF CO., LTD. 565-1 SEONWON-LI SEONNAM-MYEON SUNGJU-GUN KYEONGSANGBUK-DO 40048 SOUTH KOREA http://myroof.co.kr/english/main.php qc@feroof.com ADDITIONAL LISTEE: METSTAR USA INC. 300 INTERNATIONAL DRIVE, SUITE 100 BUFFALO, NY 14221 EVALUATION SUBJECT: STEEL ROOFING PANELS: VENETO I, VENETO II, RIO, RIO EZ, DIVA, WOOD, ZISSEN AND SLATE 1.0 EVALUATION SCOPE 1.1 Compliance with the following codes: 2009 International Building Code (2009 IBC) 2009 International Residential Code (2009 IRC) Property evaluated: Fire classification Wind resistance Weather resistance 1.2 Evaluation to the following green code: 2016 California Green Building Standards Code (CALGreen), Title 24, Part 11 Attributes verified: See Section 3.1 2.0 USES The,,,,,, and steel roofing panels are intended for installation as metal roof shingles in accordance with IBC Section 1507.5 and IRC Section R905.4, and are recognized as Class A roof coverings on new roofs and over existing roofs when installed in accordance with this report. 3.0 DESCRIPTION 3.1 General: The steel roofing panels are press formed from sheet steel complying with ASTM A792, Commercial Grade with an AZ50 class hot-dip aluminum-zinc alloy coating. The thickness of the coated steel is 0.0157 inch (0.4 mm). The aluminum-zinc alloy coated steel has coatings applied to both sides of the steel panel. The exposed proprietary side of the roof tile is surfaced with stone chips. The attributes of the steel roofing panels have been verified as conforming to the provisions of CALGreen Section A5.406.1.2 for reduced maintenance. Note that decisions on compliance for those areas rest with the user of this report. The user is advised of the project-specific provisions that may be contingent upon meeting specific conditions, and the verification of those conditions is outside the scope of this report. These codes or standards often provide supplemental information as guidance. 3.1.1 Tile: The overall panel size is 50.6 inches (1285 mm) by 16.1 inches (410 mm). The weight of the panel is approximately 5.6 lbs. The installed weight of the panel is 3.1.2 Tile: The overall panel size is 50.6 inches (1285 mm) by 16.5 inches (420 mm). The weight of the panel is approximately 5.6 lbs. The installed weight of the panel is 3.1.3 Tile: The overall panel size is 53 inches (1345 mm) by 16.3 inches (415 mm). The panel weight is 3.1.4 Tile: The overall panel size is 53 inches (1345 mm) by 16.3 inches (415 mm). The panel weight is 3.1.5 Tile: The overall panel size is 52.6 inches (1335 mm) by 16.3 inches (415 mm). The panel weight is approximately 5.7 lbs. The installed weight of the panel is 3.1.6 Tile: The overall panel size is 53.7 inches (13) by 16.3 inches (415 mm). The panel weight is ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 6

ESR-3331 Most Widely Accepted and Trusted Page 2 of 6 3.1.7 Tile: The overall panel size is 53 inches (1345 mm) by 16.3 inches (415 mm). The panel weight is 3.1.8 Tile: The overall panel size is 53 inches (1340 mm) by 16.1 inches (410 mm). The panel weight is 3.2 Accessories: Accessories are supplied by FEROOF and are as described in Section 4.2.5. 3.3 Underlayment: For roofing assemblies permitted to be nonclassified, underlayment and ice barrier must comply with IBC Section 1507.5 or IRC Section R905.4. For roof assemblies required to have roof classification, underlayment must be installed in accordance with Table 2. 4.0 INSTALLATION 4.1 General: Installation of,,,,,, and steel roof tiles must comply with this report, the manufacturer s published installation instructions, and the applicable code. The manufacturer s published installation instructions must be available at the jobsite at all times during installation. 4.2 New Construction: 4.2.1 Support Conditions: The roofing panels must be installed on roofs having a slope of 3:12 (25%) or greater. Roof rafters must be spaced not more than 24 inches (610 mm) on center. Roof panels must be installed over solid sheathing or closely fitted sheathing complying with the applicable code. 4.2.2 Underlayment: Underlayment must comply with Section 1507.5.3 of the IBC or Section R905.4.3 of the IRC, as applicable, except as noted in Table 2. 4.2.3 Panel Installation: The panels must be installed directly over closely spaced, minimum 15 / 32-inchthick (12 mm) plywood or solid sheathing complying with the applicable code. Fasteners specified in Table 1 must be installed through the panel above the panel ridge, penetrating a minimum of 1 1 / 2 inches (38 mm) into the deck. Panels in the upper course must lap panels in the lower course at the lower vertical face of the lower course panel ridge. The fasteners specified in Table 1 must be installed at the laps through two plies of panel. See Tables 1, 3 and 4 for typical installation details. Panel side laps in adjacent courses must be staggered a minimum of one pan or impression. 4.2.4,,,,, and Panel Installation: The panels and battens must be installed over closely spaced, minimum 15 / 32-inch-thick (12 mm) plywood or solid sheathing complying with the applicable code. battens, nominally 2-by-2 lumber spaced a maximum 15 inches (381 mm) on center, are attached to the deck with rafters spaced a maximum of 24 inches (610 mm) on center. Battens must be fastened to each rafter using fasteners with the minimum sizes as specified in Table 1 of this report and having sufficient length to penetrate a minimum of 1 1 / 2 inches (38 mm) into the rafter. Panels in the upper course must lap panels in the lower course at the lower vertical face of each batten. The fasteners specified in Table 1 must be installed at the laps through two plies of panel into the face of the batten. Fasteners specified in Table 1 must be installed through the panel at the upper horizontal face of each batten, penetrating a minimum of 1 1 / 2 inches (38 mm). See Tables 1, 3 and 4 for typical installation details. Panel side laps in adjacent courses must be staggered a minimum of one pan or impression. 4.2.5 Flashing, Edges and Hips and Ridges: Valley flashing must comply with IBC Section 1507.5.7 or IRC Section R905.4.6, as applicable. Roof openings must be flashed in accordance with IBC Section 1503.2 or IRC R903.2, as applicable. Openings through the roof for vents, etc., must be waterproofed and supported by additional blocking or roof framing as required by the code. At gable edges, a continuous rake cap or barge cover of the same material as the panels, supplied by FEROOF, must be installed in accordance with the manufacturer s published installation instructions. At hips and ridges, panels must be cut, bent and installed, and hip and ridge caps of the same material as the panels, supplied by FEROOF, must be installed in accordance with the manufacturer s published installation instructions. 4.3 Reroofing Applications: 4.3.1 General: The existing roof covering must be completely removed and the panels and new underlayment installed in accordance with Section 4.2, except over asphalt shingles as described in this section. For existing wood shake roofs, following the removal of the wood shakes, the panels may be installed over existing spaced sheathing provided the gaps are filled in to provide closely fitted decking having joints spaced approximately 1 / 8 inch. The fill lumber must be of the same thickness as the existing spaced sheathing. FEROOF steel roof panels may be installed over existing asphalt shingle roofs, provided the requirements of IBC Section 1510 or IRC Section R907 are met. 4.3.2 Support Conditions: Roofing panels must be installed on roofs having a slope of 3:12 (25%) or greater. Roof rafters must be spaced not more than 24 inches (610 mm) on center. 4.3.3 Batten Installation: Battens must be nominally 2-by-2 lumber. Battens must be fastened to each rafter using fasteners with the minimum sizes as specified in Table 1 of this report and having sufficient length to penetrate a minimum of 1 1 / 2 inches (38 mm) into the roof sheathing or through the roof sheathing, whichever is less. 4.3.4 Panel Installation: Panel installation must be the same as for new construction. See Sections 4.2.3, 4.2.4 and 4.2.5. 4.4 Allowable Negative Wind Pressures: FEROOF roofing panels must be installed where the negative design wind pressure, determined in accordance with Section 1609 of the IBC or Section R301.2.1 of the IRC, as applicable, does not exceed the allowable wind uplift pressure specified in Table 1 of this report. 4.5 Fire Classification: When installed in accordance with Section 4.0 and Table 2 of this report, FEROOF panels are recognized as Class A

ESR-3331 Most Widely Accepted and Trusted Page 3 of 6 roof assemblies in accordance with IBC Section 1505.2 and IRC Section R902.1, based on testing in accordance with UL 790. The Metstar Building Products Inc. panels are limited to use as nonclassified roof covering. 5.0 CONDITIONS OF USE The FEROOF Co., Ltd., steel roofing panels described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Panels must be installed in accordance with this report and the manufacturer s published installation instructions. In the event of conflict between this report and the manufacturer s published installation instructions, this report governs. 5.2 The roofing panels are manufactured in Korea, under a quality control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED Data in accordance with ICC-ES Acceptance Criteria for Metal Roof Coverings (AC166), dated October 2012. 7.0 IDENTIFICATION A label is affixed to each pallet or bundle bearing the manufacturer s name (FEROOF Co., Ltd.) and address (or the name and address of the additional listee), the product name, and the evaluation report number (ESR-3331). Panel Type Panel to Panel Fasteners TABLE 1 ALLOWABLE WIND UPLIFT PRESSURES Panel to Deck Fasteners Panel Fastener Installation Allowable Wind Uplift Pressure (psf) No. 9 by 1 1 / 2-inch-long hex head screws, five screws per panel head lap. maximum spacing 17.3 inches (439 mm) No. 9 by 1 1 / 2-inch-long hex head screws, five screws per panel maximum spacing 19.7 inches (500 mm) 60 Panel Type Panel to Batten 1 & Deck Fasteners Panel to Deck Fasteners Panel Fastener Installation Allowable Wind Uplift Pressure (psf) No. 9 by 1 1 / 2-inch-long hex head screws, five screws per panel head lap. maximum spacing 17.3 inches (439 mm) No. 10 by 3 ½-inch-long hex head screws, maximum spacing 24 inches (610 mm) 67 No. 9 by 1 1 / 2inch-long hex head screws, Five screws per panel head lap. maximum spacing 12.6 inches (320 mm) No. 10 by 3 ½-inch-long hex head screws, maximum spacing 24 inches (610 mm) 67 For SI: 1 inch = 25.4 mm, 1 psf = 48 PA. 1 Battens must be 2 by 2 inches No. 2 Grade, spaced maximum 15 inches on center. TABLE 2 FIRE CLASSIFICATION ASSEMBLIES 2 Panel Type Substrate Barrier Board 1 Underlayment Max. Roof Incline Roof Class Closely fitted, Minimum 15 / 32-inch plywood or sheathing Min. 1 / 4 inch-thick G-P Gypsum DensDecks ; or, min. 1 / 2-inch-thick gypsum board None Underlayment complying with ASTM D226 Type II or ASTM D4869 GAF VersaShield Fire- Resistant Roof Deck Protection (ESR-2053) Unlimited A For SI: 1 inch = 25.4 mm, 1 psf = 48 PA. 1 All barrier board joints to be staggered a minimum of 6 inches from joints in plywood or sheathing. 2 Battens, when used, must be installed over the barrier board or GAF VersaShield Fire-Resistant Roof Deck Protection.

ESR-3331 Most Widely Accepted and Trusted Page 4 of 6 Panel Type TABLE 3 FASTENING PATTERN FASTENER SPACING ILLUSTRATION

ESR-3331 Most Widely Accepted and Trusted Page 5 of 6 TABLE 3 FASTENING PATTERN (CONTINUED)

ESR-3331 Most Widely Accepted and Trusted Page 6 of 6 TABLE 4 SIDE LAPS Panel Type Side Lap Width Panel Side Lap Fastener(s) Location 70 mm (2.8 in.) 70 mm (2.8 in.) 55 mm (2.2 in.) 60 mm (2.4 in.) TABLE 5 PRODUCT CROSS REFERENCE FEROOF Co., LTD Metstar Building Products, Inc. DaVinci FV I DaVinci FV II Tile FR Tile FR EZ FD Shake FW Tile 2 FZ MF