STRUCTURAL CALCULATIONS

Similar documents
STRUCTURAL CALCULATIONS

STRUCTURAL CALCULATIONS

STRUCTURAL CALCULATIONS

STRUCTURAL CALCULATIONS

STRUCTURAL CALCULATIONS

Report No 2370/ Part 2 of 2 Issue 2 This Report consists of 10 pages. Authority & date BSI Service Management Order Number

Test Report IMS Nederland B.V.

Report No 2370/ Part 1 of 2 Issue 3 This Report consists of 15 pages. Authority & date BSI Service Management Order Number

TEST REPORT. Lucideon Reference: (QT-49195/1/GMB)/Ref. 1. Testing of OnLevel TL6020 Balustrade System in Accordance with BS 6180:2011

BS 6180: 1999: Barriers in and about buildings Code of practice - General Contract use Clauses 6.4.1

TEST REPORT (QT39584/2/JPS)/Ref. 10/Supp1. Lucideon Reference:

EASY GLASS JULIET BALCONY MOD.6507 & 6508

Structural Calculations for standard BALCONY 1 system handrail using 55mm diameter posts (48.3mm x 5mm CHS) & 150 x 150 x 15mm base plates

TEST REPORT. Lucideon Reference: (QT39584/2/JPS)/Ref. 5

TEST REQUIREMENTS : RESULT : BS 6180: 1999: Barriers in and about buildings Code of practice - Communal domestic use Clauses 6.4.1

TEST REPORT. Lucideon Reference: (QT39584/2/JPS)/Ref. 11

EASY GLASS HYBRID POST FASCIA MOUNT

TEST REPORT. Spig Lite Pro. Frameless Balustrade. Testing carried out by: Queens Road Penkhull Stoke On Trent

TEST REPORT Juliet Balcony System - SKYFORCE

EASY GLASS MOD 6400 BASE GLASS CLAMP

TEST REPORT. Lucideon Reference: (QT44718/2/RK)/Ref. 6

BS 6180: 1999: Barriers in and about buildings Code of practice - Domestic Use Clause 6.4.1

TEST REPORT. Lucideon Reference: (QT39584/2/JPS)/Ref. 2

EASY GLASS HYBRID WALL CONNECTION

TEST REQUIREMENTS : RESULT : BS 6180: 1999: Barriers in and about buildings Code of practice - Communal domestic use Clauses 6.4.1

TEST REPORT. Lucideon Reference: (QT44718/2/RK)/Ref. 8

TEST REQUIREMENTS: BS 6180:2011: Barriers in and about buildings Code of practice : Domestic applications Clause 6.4.1

TEST REPORT. Lucideon Reference: (QT-49116/2/RK)/Ref. 1

BS 6180: 1999: Barriers in and about buildings Code of practice - General Contract use Clauses 6.4.1

BS 6180: 1999: Barriers in and about buildings Code of practice - General Contract use Clauses 6.4.1

APPROVED DOCUMENT K PROTECTION FROM FALLING, COLLISION & IMPACT. The Building Regulations 2010 PART K

Frameless Glass Balustrades Product Information Sheet

Updated May BALUSTRADE & FENCE DESIGN

Load testing of a PVC coated handrail system. 25 th March Test report number

CIVL473 Fundamentals of Steel Design

Flexure and Serviceability Limit State

The Infinity Balustrade System

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

UNIVERSITY OF BOLTON WESTERN INTERNATIONAL CENTRE FZE. BEng (HONS) CIVIL ENGINEERING SEMESTER ONE EXAMINATION 2015/2016

Example. Monday, October 19, 2015

Renovation of Buildings using Steel Technologies (ROBUST)

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road QUESTION BANK (DESCRIPTIVE)

2016 DESIGN AND DRAWING OF REINFORCED CONCRETE STRUCTURES

Contents. 1.1 Introduction 1

Analysis and Design of Steel

Acceptable Solution F4/AS1

Contents. Foreword 1 Introduction 1

Dear Customer. Section Old F4 January 2017 Amendment 2. Remove title page and document history page 1-2B

Structural Design of Pergola with Airfoil Louvers

For New Zealand Building Code Clause F4 Safety from Falling

American Residential Deck Railing Design Guide

Introduction 2 The Guidance Existing Buildings Technical Specifications Materials and Workmanship Interpretation. Part K : The Requirement 3

R10 SET For the continuous beam ABCD shown in fig.3.1 find moments at support and reactions at support. Draw SF and BM diagrams. Fig. 3.

CITY OF TORONTO. BY-LAW No (OMB)

COVENANT UNIVERSITY NIGERIA TUTORIAL KIT OMEGA SEMESTER PROGRAMME: BUILDING TECHNOLOGY

STANDARDS AUSTRALIA. Amendment No. 1 to AS Residential timber-framed construction Part 1: Design criteria

Guidelines for SINTEF Technical Approval Glass railing Railing with glass as complementary or load carrying element

Lecture Retaining Wall Week 12

All- Glass Staircase, Notting Hill, London

UNIVERSITY OF BOLTON WESTERN INTERNATIONAL COLLEGE FZE. BEng (HONS) CIVIL ENGINEERING SEMESTER ONE EXAMINATION 2018/2019

Level 6 Graduate Diploma in Engineering Structural analysis

COMPOSITE STRUCTURES PREPARED BY : SHAMILAH

Approved Document. Protection from falling, collision and impact. The Building Regulations 2010

Portal frame PLASTIC DESIGN OF PORTAL FRAMES


Flat Slabs. d 2. A typical flat slab (without drop and column head)

FULLY GLAZED INTERIOR PARTITIONS

UNIVERSITY OF BOLTON SCHOOL OF ENGINEERING. BEng (Hons) CIVIL ENGINEERING

Universal Beam and Universal Column sections subject to pure bending are all Class 3 semi-compact or better.

Two-way slabs. Flat plate with or without drop panels / capitals

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations

S. Gandhi *1, Syed Rizwan 2

Contents. Tables. Notation xii Latin upper case letters Latin lower case letters Greek upper case letters Greek lower case letters. Foreword.

VTU EDUSAT PROGRAMME Lecture Notes on Design of Stair cases

TECHNICAL INSTALLATION

Question Paper Code : 11410

Questions with Solution

UNIT-1 RETAINING WALLS

5.2 Design Section Moment and Web Capacities

CADS A3D MAX. How to model shear walls

Effect of lateral support of compression flange to stability of beam-columns

Lintels and Beams: Engineering Basis

CHAPTER FIVE 5.1 MODELING OF A TEN-STOREY BUILDING

Lintels and Beams Engineering basis

EN REINFORCED MASONRY DESIGN EXAMPLE 1 (NOTE: THIS USES THE UK NATIONAL ANNEX NDP VALUES)

STRUT METAL FRAMING SYSTEMS

Example of a modelling review Roof truss

CIVIL ENGINEERING YEAR QUESTION BANK

CE2401-DESIGN OF REINFORCED CONCRETE AND BRICK MASONRY QUESTION BANK

Analysis and Design of Structural Glass Systems

Design for Shear for Prestressed Concrete Beam

ARCHIVED. Compliance Document for New Zealand Building Code Clause F4 Safety from Falling Second Edition

DESIGN OF RC ELEMENTS UNIT 1 PART-A

REINFORCED CONCRETE DESIGN

mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

VALLIAMMAI ENGINEERING COLLEGE

NATIONAL ANNEX TO STANDARD. SFS-EN EUROCODE 1: ACTIONS ON STRUCTURES Part 1-7: General actions Accidental actions

Recommendations for additional fire protection of structural elements

Safety Barrier Solutions

LVL Portal Frame Design. Warwick Banks Technical Manager

Transcription:

STRUCTURAL CALCULATIONS FOR JULIET BALCONY BALUSTRADES USING 21.5mm LAMINATED GLASS SYSTEM BY Balcony Systems Solutions Ltd Unit 6 Systems House Eastbourne Road Blindley Heath Lingfield Surrey RH7 6JP page 1 of 12

LAMINATED GLASS SYSTEM page 2 of 12

21.5m LAMINATED GLASS SYSTEM page 3 of 12

BALUSTRADE LOADS: (a) Horizontal loads The balustrade is designed to resist the horizontal imposed loads specified in Table 4 of BS 6399-1:1996 (see below), covering occupancy classes A(i) and (ii), B(iii), (iv) and (v), C3 (iii), (iv), (viii) and (ix). The loads are separately applied, not co-existent. The horizontal uniformly distributed line load of 0.74 kn/m is applied 1100mm above finished floor level. Table 4 Minimum horizontal imposed loads for parapets, barriers and balustrades, etc. Horizontal A uniformly Type of occupancy for part of the building or structure Examples of specific use uniformly distributed line load (kn/m) distributed load applied to the infill (kn/m 2 ) A Domestic and residential activities B and E Offices and work areas not included elsewhere including storage areas C Areas where people may congregate C1/C2 Areas with tables or fixed seating C3 Areas without obstacles for moving people and not susceptible to overcrowding C5 Areas susceptible to overcrowding D Retail areas F/G Vehicular A point load applied to part of the infill (kn) (i) All areas within or serving exclusively one [A1] single family [A1] dwelling including stairs, landings, etc but excluding external balconies and edges of roofs (see C3 ix) 0.36 0.5 0.25 (ii) Other residential, (but also see C) 0.74 1.0 0.5 (iii) Light access stairs and gangways not 0.22 N/A N/A more than 600mm wide (iv) Light pedestrian traffic routes in 0.36 0.5 0.25 industrial and storage buildings except designated escape routes (v) Areas not susceptible to overcrowding in 0.74 1.0 0.5 office and institutional buildings also industrial and storage buildings except as given above (vi) Areas having fixed seating within 530 1.5 1.5 1.5 mm of the barrier, balustrade or parapet (vii) Restaurants and bars 1.5 1.5 1.5 (viii) Stairs, landings, corridors, ramps 0.74 1.0 0.5 (ix) External balconies and edges of roofs. 0.74 1.0 0.5 Footways and pavements within building curtilage adjacent to basement/sunken areas (x) Footways or pavements less than 3 m wide adjacent to sunken areas (xi) Theatres, cinemas, discotheques, bars, auditoria, shopping malls, assembly areas, studio. Footways or pavements greater than 3 m wide adjacent to sunken areas (xii) [A1] Grandstands and stadia [A1] (xiii) All retain areas including public areas of banks/building societies or betting shops. For areas where overcrowding may occur, see C5 (xiv) Pedestrian areas in car parks including stairs, landings, ramps, edges or internal floors, footways, edges of roofs (xv) Horizontal loads imposed by vehicles See clause 11 [A1] Not deleted [A1] 1.5 1.5 1.5 3.0 1.5 1.5 See requirements of the appropriate certifying authority 1.5 1.5 1.5 1.5 1.5 1.5 page 4 of 12

JULIET BALCONIES LAMINATED GLASS SYSTEM: Horizontal loads: The glass is designed to resist a horizontal imposed service line load of 0.74 kn/m applied 1100mm above finished floor level, or a uniformly distributed load of 1.0 kn/m 2 or a point load of 0.5 kn applied at any position. The loads are separately applied, not additive. Vertical loads: The glass is designed to resist a vertical concentrated service load of 1.0 kn applied in any position along the length, or a uniformly distributed load of 0.60 kn/m, whichever gives the worst design condition in combination with the horizontal load. Factored loads: Factored loads are used for checking the limit state of static strength of the glass. The imposed service loads noted above are multiplied by a load factor of Ya which is related to the risk involved in failure of the member under consideration. For balustrades and barriers where failure would involve a risk of falling Ya is taken as 1.5. Deflection: All structural members deflect to some extent under load. For balustrades and barriers the deflection is limited to 25mm under service load conditions. Structural system: The glass spans horizontally between points of support anchored to the main building structure each side of door or window openings. The horizontal imposed service load of 0.74 kn/m is applied towards the top of the glass. Owing to shear lag effects more of this load will be carried by the top half of the glass than the bottom. The glass is approximately 1100mm high. For design purposes it is considered reasonable to assume that 60% of the horizontal imposed line load is carried by the top 550mm of glass and the remaining 40% by the bottom 550mm. Design span: For the 21.5mm laminated glass system the calculations are based upon a maximum horizontal span of 3200mm between points of support on the main building structure. page 5 of 12

Design data: Design standard = Institution of Structural Engineers publication Structural use of glass in buildings (second edition) February 2014. Glass type = 21.5mm laminated glass, comprising 2 x 10mm thick plies of thermally toughened sheets of soda lime silicate safety glass bonded by means of a 1.5mm PVB interlayer. Smooth float as produced finish with polished edges. Characteristic strength = 120 N/mm 2 Design f g;d = K mod x K sp x K g;k + K y (f b:k f g:k ) strength Y M;A Y M;V where: K mod = 30 second load duration factor = 0.89 for a domestic balustrade load K sp = glass surface profile factor = 1.0 for float glass as produced f g:k = characteristic strength of basic annealed glass = 45 N/mm 2 K v = manufacturing process strengthening factor = 1.0 for horizontal toughening f b;k = glass characteristic strength Y M;A = material partial factor = 1.6 for basic annealed glass Y M;V = material partial factor = 1.2 for surface prestressed (toughened) glass Design f g:d = 0.89 x 1.0 x 45 + 1.0 (120 45) stress 1.6 1.2 (ultimate) = 25.03 + 62.50 = 87.53 N/mm 2 page 6 of 12

Consider the top 550mm of glass subject to horizontal line loading over a span between points of support of 3200mm: factored uniformly distributed = 0.74 kn/m x 60% x 1.5 load factor line load on 550mm strip = 0.666 kn/m factored BM on strip = 0.666 kn/m x (3.2) 2 8 = 0.852 knm effective thickness of laminated = 3 h k glass in terms of bending stress (h ef;w) + 12 ŵ { h k h m;k 2 } where: h k = thickness of plies = 10mm ŵ = coefficient of shear transfer; standard grade PVB; family 2; personal load; normal duty. = 0.10 H ef;w = (10) 3 + 12 x 0.1 (10) 3 = 2200 = 13mm section modulus (Z) of 550 wide = 550 x (13) 2 strip x 13mm effective thickness 6 = 15492mm 3 ultimate bending stress M = 0.852 x (10) 6 Z 15492 = 54.996 N/mm 2 = < 87.53 N/mm 2 = OK page 7 of 12

Service load deflection on = 5 w L 4 550 x 21.5mm strip ( ) 384 E I Where: w = service load per metre = 60% x 740 N/m = 444 N/m L = span between points of support = 3200mm E = Young s modulus of glass 70,000 N/mm 2 I = 2 nd moment of area of strip = 550 x (21.5) 3 12 = 455509 mm 4 = 5 x (444 x 3.2) (3200) 3 384 x 70000 x 455509 = 19.01mm = < 25mm = OK Check for the service uniformly distributed load of 1.0 kn/m 2 applied to the 550mm wide strip: factored load = 1.0 kn/m 2 x 0.55 x 1.5 load factor = 0.825 kn/m factored BM = 0.825 x (3.2) 2 8 = 1.056 knm ultimate bending stress M = 1.056 x (10) 6 Z 15492 = 68.16 N/mm 2 = < 87.53 N/mm 2 = OK page 8 of 12

Check deflection on 550mm wide strip resisting a service load of 0.55 kn/m arising from the UDL load of 1.0 kn/m 2. = 5 x (0.55 x 3.2) (3200) 3 Vertical loads: 384 x 70000 x 455509 = 23.55mm = < 25mm = OK Structural system: The glass is required to support a vertical imposed uniformly distributed load of 0.60 kn/m or a concentrated vertical point load of 1.0 kn applied at any position along the length. These are service loads. A load factor of 1.5 is applied to the loads to give design ultimate loads. In resisting vertically applied loads the glass acts as a narrow beam that is laterally unrestrained between the points of support at either ends. Lateral torsional buckling is a key criterion in the design. The Institution of Structural Engineers publication Structural use of glass in buildings (second edition) February 2014 make reference to the Australian code of practice on the design of structural glass for guidance on the buckling analysis of glass beams. Appendix C of AS 1288-2011 recommends that for unrestrained beams the buckling resistance can be obtained from the following equation: M CR = (g 2 ) x [(El) y (GJ)] 1/2 {1 x g 3 (y r1 ) [El)y (GJ)] 1/2 } (L ay ) (L ay ) where: M CR = critical elastic buckling moment L ay = distance between points of effective rigid rotational restraints page 9 of 12

Vertical loads on glass (continued) (E l)y = effective rigidity for bending about the minor axis (GJ) = effective torsional rigidity g 2 = slenderness ratio for mid-point load with major axis restraint only = 4.2 for simply supported g 3 = slenderness ratio for mid-point load with major axis restraint only = 1.7 for simply supported yh = distance from the l xx axis to the point of application of the load = d/2 = 550mm modulus of rigidity G = 28700 N/mm 2 depth of beam d = 1100mm (nominal) effective width b = 14mm second moment ly = d b 3 of area about 12 minor axis = 1100 x (14) 3 12 = 251533mm 4 polar moment J = d b 3 (1 0.63 x 14 ) of area 3 1100 = 1100 x (14) 3 (1 0.63 x 14 ) 3 1100 = 1 x (10) 6 mm 4 effective torsional (GJ) = 28700 x (10) 6 N/mm 2 rigidity = 2.87 x (10) 10 N/mm 2 page 10 of 12

Vertical loads on glass (continued) (GJ) 1/2 = [2.87 x (10) 10 ] 1/2 = 169410 N/mm 2 (El)y = 70000 N/mm 2 x 251533mm 4 = 1.76 x (10) 10 [(El)y (GJ)] 1/2 = [169410 x 1.76 x (10) 10 ] 1/2 = 54.6 x (10) 3 N/mm 2 (g 2 ) = 4.2 = 1.31 x (10) -3 (Lay) 3200 (yh) = 550 = 0.172 (Lay) 3200 Critical buckling moment: M CR = (g 2 ) x [(Ely) (GJ)] 1/2 {1 x g 3 (yh) [(Ely) (GJ)] 1/2 (Lay) (Lay) = 1.31 x (10) -3 [54.6 x (10) 3 {1 x 1.7 (0.172) [54.6 x (10) 3 ]} = 11412 x (10) 3 Nmm = 11.412 knm factored central = 1.50 kn point load factored BM from = 1.50 x 3.2 = 1.20 knm point load = 4 = < 11.412 knm OK factored UDL = 0.60 kn/m x 1.5 = 0.90 kn/m factored BM from = 0.90 x (3.2) 2 = 1.152 knm UDL 8 = < point load BM section modulus Z = 12 x (1100) 2 = 2.42 x (10) 6 mm 3 based on 2 x 10mm 6 panes factored bending = 1.2 x (10) 6 = 0.496 N/mm 2 stress M/Z 2.42 x (10) 6 = v. small combined ultimate = 68.53 + 0.496 = 69.026 N/mm 2 bending stress = < 87.53 N/mm 2 = OK page 11 of 12

Fixing bolts: Conservatively, it will be assumed that the top fixing bolt resists the whole of the pull-out force arising from the imposed horizontal service load of 0.74 kn/m, plus tension from the vertical imposed service load of 1.0 kn acting at the support, plus tension from the self weight of the glass. Bolt tension due to the horizontal = 0.74 kn/m x 1.6 = 1.184 kn imposed load of 0.74 kn/m Bolt tension due to vertical = 1.0 kn x 0.050 = 0.050 kn imposed load of 1.0 kn on a 50mm cantilever Bolt tension due to self weight = 25 kn/m3 x 0.0215 = 0.027 kn of the glass 21.5mm thick @ x 0.50 2500 kg/m 3 = 1.261 kn say = 1.30 kn SUMMARY 1. The 21.5mm laminated glass system for Juliet balconies by Balcony System Solutions Limited comprises two 10mm thick panes of thermally toughened soda lime silicate safety glass bonded together by means of a 1.5mm thick PVB interlayer to give an overall glass thickness of 21.5mm. 2. The glass is secured to the building structure by means of aluminium brackets bolted to the structure each side of door or window openings as shown on the details on page 3 of these calculations. 3. The structural calculations show that the 21.5mm laminated glass system is adequate to support the balustrade design loads specified in Table 4 of BS 6399-1:1996, relating to occupancy classes A, B, E and C3, up to a maximum span between points of support of 3.2 metres.. 4. The design allows for a horizontal uniformly distributed line load of 0.74 kn/m applied to the glass 1100mm above finished floor level, or a uniformly distributed load of 1.0 kn/m 2. In addition the design allows for a vertical point load of 1.0 kn applied in any position along the top of the glass, or a uniformly distributed vertical load of 0.60 kn/m. 5. On the maximum span of 3.2 metres between points of support the design working load pull-out force on the fixing bolts is 1.3 kn/bolt. This should be readily achievable with 10mm or 12mm diameter resin anchor bolts. 6. The installers should satisfy themselves that the anchor bolts chosen are suitable to resist this pull-out force, and also that the structure into which the bolts are installed is adequate to support this load. END page 12 of 12