NLFEA Fire Resistance of 3D System Ceiling Panel

Similar documents
Chapter 7. Finite Elements Model and Results

CHAPTER 5 FINITE ELEMENT MODELLING

Effect of High Temperature on the Strain Behavior in Post-Tensioning Concrete Beams by Using Finite Element Method (ANSYS Program)

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

Nonlinear Finite Element Analysis of Composite Cantilever Beam with External Prestressing

The Use of Sustainable Materials for Quick Repair of Aging Bridges

Parameters Affecting Load Capacity of Reinforced Self-Compacted Concrete Deep Beams

Chapter 2 Notation and Terminology

CHAPTER 8 FLEXURAL BEHAVIOUR OF FIBRE REINFORCED GEOPOLYMER COMPOSITE R.C. BEAMS

Effect of Flange Width on Flexural Behavior of Reinforced Concrete T-Beam

Study the Behavior of Reinforced Concrete Beam Using Finite Element Analysis

BEHAVIOR OF REINFORCED CONCRETE BEAM WITH OPENING

Parametric Study of Continuous Concrete Beam Prestressed with External Tendon

ZANCO Journal of Pure and Applied Sciences

NONLINEAR FINITE ELEMENT ANALYSIS OF SHALLOW REINFORCED CONCRETE BEAMS USING SOLID65 ELEMENT

STRUCTURAL APPLICATIONS OF A REINFORCED CONCRETE BEAM-COLUMN-SLAB CONNECTION MODEL FOR EARTHQUAKE LOADING

Behaviour of Concrete Filled Rectangular Steel Tube Column

beni-suef university journal of basic and applied sciences 5 (2016) Available online at ScienceDirect

Journal of Asian Scientific Research EVALUATION OF RECTANGULAR CONCRETE-FILLED STEEL-HOLLOW SECTION BEAM-COLUMNS

FE MODELING OF CFRP STRENGTHENED CONCRETE BEAM EXPOSED TO CYCLIC TEMPERATURE, HUMIDITY AND SUSTAINED LOADING

Experimental and Analytical Study on Flexural Behavior Of Curved Beams

CHAPTER 7 ANALYTICAL PROGRAMME USING ABAQUS

CAUSES OF ELONGATION IN REINFORCED CONCRETE BEAMS SUBJECTED TO CYCLIC LOADING

PRIMARY AND SECONDARY REINFORCEMENTS IN CORBELS UNDER COMBINED ACTION OF VERTICAL AND HORIZONTAL LOADINGS

INFLUENCE OF PRSTRESS LEVEL ON SHEAR BEHAVIOR OF SEGMENTAL CONCRETE BEAMS WITH EXTERNAL TENDONS

ANALYTICAL STUDY ON FLANGED SHEARWALL UNDER LATERAL LOADING

MODELING OF CARBON FIBER REINFORCED POLYMER (CFRP) STRENGTHENED REINFORCED CONCRETE (RC) BEAMS: EFFECT OF BEAM SIZE AND CFRP THICKNESS

Finite Element Analysis of R.C. Arches with Openings Strengthened by CFRP Laminates

Nonlinear Analysis of Shear Dominant Prestressed Concrete Beams using ANSYS

Nonlinear Finite Element Modeling & Simulation

The Effect of Column Axial Load on the Progressive Collapse

Nonlinear Modeling and Analysis of AAC infilled Sandwich Panels for out of Plane Loads

FEM performance of concrete beams reinforced by carbon fiber bars

Finite element modeling of high-strength fiber reinforced beam-column joints

FLEXURAL BEHAVIOR OF LIGHTWEIGHT AGGREGATEE CONCRETE ONE-WAY

Reinforced Concrete Design. A Fundamental Approach - Fifth Edition

BEHAVIOUR OF REINFORCED CONCRETE STRUCTURES IN FIRE

An Experimental and Analytical Study On Composite High Strength Concrete Fibre Reinforced Polymer Beams

Effects of Opening Shape and Location on the Structural Strength of R.C. Deep Beams with Openings

Department of Civil Engineering, UIT, RGPV, Bhopal, India

3-D FINITE ELEMENT ANALYSIS OF PILE-TO-PILE CAP CONNECTIONS SUBJECTED TO SEISMIC ACTION

Effect of prestressed CFRP plate location on behavior of RC beam strengthened with prestressed CFRP plate

Numerical Modeling of Innovative Connection Between RC Beam and Steel Column

CHAPTER 7 FINITE ELEMENT ANALYSIS

Finite element modeling of RC deep beams strengthened in shear with CFRP strips

Experimental and Numerical Study on the Effects of Size and type of Steel Fibers on the (SIFCON) Concrete Specimens

Tensile Stress-Strain Relationship of High-Performance Fiber Reinforced Cement Composites

ANALYTICAL STUDY OF PUNCHING SHEAR ON WAFFLE SLAB WITH DIFFERENT RIB SIZES

ANALYSIS OF CARBON-FIBER COMPOSITE STRENGTHENING TECHNIQUE FOR REINFORCED BEAM

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 1, 2011

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 1, 2011

Non Linear Analysis of Composite Beam Slab Junction with Shear Connectors using Ansys.16

Experimental and Analytical Analysis of Flexural Behaviour of Reinforced Concrete Composite Beams

Tests of R/C Beam-Column Joint with Variant Boundary Conditions and Irregular Details on Anchorage of Beam Bars

Finite element analysis on steel-concrete-steel sandwich composite beams with J-hook shear connectors

Analysis of Flexural Behaviour of Singly and Doubly Reinforced High Strength Concrete Beams Using Ansys

Effect of Loading and Beam Sizes on the Structural Behaviors of Reinforced Concrete Beams Under and After Fire

BEHAVIOUR OF PRE-FIRE AND POST-FIRE PERFORMANCE OF ECCENTRICALLY LOADED SRC COLUMNS AND JOINT

Experimental and analytical study of the steel-concrete-steel beam under flexural behavior

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

Numerical Analysis of Strengthening R.C Slabs with Opening using Ferrocement Laminates

Steel Jacketing Technique used in Strengthening Reinforced Concrete Rectangular Columns under Eccentricity for Practical Design Applications

Encased Beam with Variable Upper Steel Flange Position

Seismic performance of New Steel Concrete Composite Beam-Columns

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

Analytical Modeling of the Contribution of Transverse Reinforcement in Prestressed Concrete Bridge Girders

Nonlinear Models of Reinforced and Post-tensioned Concrete Beams

Load Deflection Behaviour of Restrained RC Skew Slabs Using FEM Technique

COMPARATIVE STUDY OF BEAMS BY USING DIFFERENT TYPES OF RETROFITING TECHNIQUES

REVIEW PAPER ON USAGE OF FERROCEMENT PANELS IN LIGHTWEIGHT SANDWICH CONCRETE SLABS

Numerical Modeling of Reinforced Concrete Beams Strengthened by NSM-CFRP Technique

Fundamental Course in Mechanical Processing of Materials. Exercises

Flexural behaviour of a polymeric foam/glass-fibre composite: FE modelling and experimental testing

Modelling of Sheared Behaviour Bolts Across Joints

ELASTIC AND ELASTO-PLASTIC BUCKLING ANALYSIS OF PERFORATED STEEL PLATES

ANALYTICAL STUDY ON STRESS-STRAIN BEHAVIOUR OF REINFORCED CONCRETE COLUMN

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS

Behavior of Reinforcement Concrete Beams Using Steel Strips as a Shear Reinforcements

THE EFFECT OF THE TYPES OF SUPPORTS IN THE DISTRIBUTION OF LOADS BETWEEN THE GIRDERS OF THE BRIDGE

Case Study: Challenges of a Single-layer Reticulated Dome

INFLUENCE OF SHEAR REINFORCEMENT ON RESIDUAL LOAD CAPACITY OF RC BEAMS WITH CORROSION

Research on Weight Reduction of PC Composite Members Using Ultra High Strength Fiber Reinforced Cementitious Composites (UFC)

ME 207 Material Science I

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 2, 2010

Creep Response of a Prestressed Concrete Beam under Sustained Load

DYNAMIC RESPONSE ANALYSIS OF THE RAMA 9 BRIDGE EXPANSION JOINT DUE TO RUNNING VEHICLE

EXPERIMENTAL INVESTIGATION OF PRECAST CONCRETE BEAM TO COLUMN CONNECTIONS SUBJECTED TO REVERSED CYCLIC LOADS

CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS

Finite Element Analysis of RC Beams Strengthened with FRP Sheets under Bending

Punching shear strength of RC slabs with AFRPm and PVA short-fiber-mixed shotcrete

International Journal of Advance Engineering and Research Development. Analytical Investigation on Behaviour of RC Framed Corner Joints

Finite Element Modeling of Hybrid Fibre Reinforced Concrete Beam with Elastomeric Bearing Pads

EFFECTS OF SHEAR SPAN-DEPTH RATIO ON THE BEHAVIOR OF HYBRID REINFORCED CONCRETE CONTINUOUS STRAIGHT DEEP BEAM

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 1, 2012

Parametric study on the shear strength of concrete deep beam using ANSYS

In-plane testing of precast concrete wall panels with grouted sleeve

3D FINITE ELEMENT MODELS OF PLAIN AND BOND-BEAMED HOLLOW MASONRY WALLS SUBJECTED TO CONCENTRIC AND ECCENTRIC CONCENTRATED LOADS

STRUCTURAL BEHAVIOUR OF HYBRID CONCRETE BEAMS WITH FIBRE REINFORCED LIGHTWEIGHT CONCRETE

Structural Characteristics of New Composite Girder Bridge Using Rolled Steel H-Section

INELASTIC SEISMIC RESPONSE ANALYSES OF REINFORCED CONCRETE BRIDGE PIERS WITH THREE-DIMENSIONAL FE ANALYSIS METHOD. Guangfeng Zhang 1, Shigeki Unjoh 2

Transcription:

NLFEA Fire Resistance of 3D System Ceiling Panel Rajai Z. Al-Rousan 1 Department of Civil Engineering, Jordan University of Science and Technology, Irbid, Jordan E-mail: rzalrousn@just.edu.jo 2 Department of Civil and Infrastructure Engineering, American University of Ras Al Khaimah, Ras Al Khaimah, UAE Abstract- In concrete structures, determining the fire endurance time is fundamental so as ensure that structural elements be able to withstand an aggressive fire for a reasonable time period. Slabs are the most susceptible to fire damage because of their large surface area and shallow depth. Analyzing their bearing capability after sustaining fire requires the knowledge of temperature distribution in the cross sections, as well as thermal properties of concrete and embedded steel. In this paper, fire endurance a typical 3D ceiling panel is investigated analytically by using ANSYS in terms of time to failure and physical changes associated with exposure to failure. A nonlinear finite element (NLFEA) model was developed and validated by the experimental data before predictions were extended to investigate the significance of concrete density, concrete mechanical properties, and bottom concrete layer cover on the fire endurance time. savings in energy and building costs while possessing higher seismic stability as compared to tradition reinforced concrete and steel structures. Three dimensional panel systems have been used in various parts of the word to construct multistory buildings and houses since 1 years ago [9]. A geometric configuration of a typical 3D ceiling panel is shown in Figure 1. The panel consists of two steel meshes on both sides of an expanded polystyrene core and connected together with a truss wire to provide a 3D system. Additional longitudinal reinforcement was added at the tension side to promote structural capacity. A major concern regarding the use of the new building system is its ability to withstand an aggressive fire. In this paper, the fire time endurance of a typical panel was determined analytically using nonlinear finite element analysis (NLFEA). The NLFEA aimed at determining optimal key parameters that enhance fire endurance of the panels under study. Keywords: Fire, Resistance, 3D System, Ceiling, Panel, Endurance Time, Thermal Analysis, NLFEA. INTRODUCTION People around the world expect that their workplaces and homes will be protected from the depredation of an unwanted fire. Therefore, it is extremely important to have sufficiently strong reinforced concrete (RC) structures to withstand fire damage to property and human life. The fire safety of RC structures largely depends on their fire resistance, which in turn depends on the fire resistance and combustibility of their main structural elements especially loaded flexural members. The post-fire residual load bearing capacities of these members are significant factors in determining the safety of the structure. Hence, the post and under fire residual mechanical properties of their reinforcing steel, concrete, and constituent materials are extremely important [1-6]. Analyzing the bearing capability of RC slabs after sustaining fire requires the understanding of temperature distribution in the cross sections. This is usually determined by the thermal properties of the material, such as the heat capacity and thermal conductivity. A simple thermal model, which is generally to all slabs with a rectangular cross section, has been assessed in a separate serious of studies which were also reported in a previous paper [7]. The modeling results achieved realistic concurrence with isothermal contours obtained by Lin [8], who analyzed the temperature distribution of pure concrete according to the time-temperature curve of standard fire. Recently, there has been an increasing interest in using new structural systems for green housing. Such systems allow Figure 1: Typical panel showing steel meshes in concrete layers, steel truss, and polystyrene core Nonlinear Finite Element Analysis (NLFEA) Specimen details and materials properties Figure 2 shows the typical dimensions and reinforcement layouts for the test specimens by Rami Haddad [1]. The 3D panel system was made from the welded truss of wire cross pieces, zinc coated steel wire mesh on inside and outside with a diameter of 3 mm (3.1 mm), and foamed polystyrene. Additional 8 mm bars were added as shown in Figure 2. The panels were cast through shotcreting of the 5-mm concrete bottom layer or conventional placing of the 7-mm top concrete layer. The ceiling panels (4 22 15 mm) were sliced from full-scale panels having 12 mm width and 3 mm length. The yield and ultimate strengths and elongation at failure for the reinforcing steel was determined experimentally. Corresponding results for 3 and 8 mm 7878

bars were (477 and 394 MPa), (752 and 59 MPa), and (2.4 and 1.4%), respectively. Concrete cores (75 mm) were taken from the concrete top layer, cast especially for obtaining cores, before tested for compressive strength according to ASTM C42. The average compressive strength for 6 cores was 1 MPa. 9 8 7 6 5 4 3 2 Standard Fire Figure 2: Cross section in the panel showing 3-mm steel meshes and 8-mm additional bottom steel along with locations of thermocouples (dimensions in millimeters) [1] Fire endurance test The ceiling panels were loaded up to 5% of their nominal flexural and axial load capacity, before subjected to fire at their middle third as shown in Figure 3 [1]. The fire exposure is controlled to conform to the standard timetemperature curve recommended by the ASTM E119 [11] as shown in Figure 4. Figure 3: Schematics showing test setup [1] 1 2 3 4 5 6 Figure 4: Standard time-temperature curve Modeling A NLFEA model was proposed and validated using the present data before used to predict fire endurance of a typical 3D panel system prepared from concretes of variable densities yet having same compressive strength. The analysis was carried out using the software package ANSYS (211) [12] using various element types for concrete, reinforcing steel and the polystyrene core. Concrete The concrete was modeled by using a plane element PLANE55 which can be used as an ax-symmetric ring element with a 2-D thermal conduction capability. At each node, the element has four nodes with a single degree of freedom and temperature. The element is applicable to a 2-D, transient thermal analysis or steady-state, and can also compensate for mass transport heat flow from a constant velocity field. The element should be replaced by an equivalent structural element (such as PLANE42) if the model containing the temperature element is also to be analyzed structurally. In order to define the failure criterion of the concrete, the young's elastic modulus, compressive strengths, and ultimate tensile were used, along with an estimated Poisson s ratio of.2. The condition of the crack face is defined in term of shear transfer coefficient ( t); a common value of which was used at.2 [13, 14]. Steel The reinforcement bars are indistinguishable in compression and tension with idealized elastic-plastic behavior. LINK32 element was used to model the reinforcement bars which is a uniaxial element with the ability to conduct heat between its nodes. At each node point, the element has a single degree of freedom, temperature, and is applicable to a 2-D (plane or axisymmetric), steady-state or transient thermal analysis. The steel supports and loading steel plates ( 5mm) were modeled using PLANE42 element. 7879

Polystyrene The polystyrene was modeled using PLANE55 element with a 2-D thermal conduction capability. Data entry The elements PLANE55 and PLANE42 are defined by 4 nodes, while the element LINK8 is defined by 2 nodes, with the four elements having 3 degrees of freedom at each node reflecting translations freedom in the x, y, and z directions. Real constant of set 1 that defines the material number was used for the concrete (PLANE55 element) which include reinforcement type, its ratio in concrete, and orientation. The cross sectional areas of the main steel and stirrups were entered for the LINK32 element as real constant sets 2. Nonlinear solution and failure criteria Convergence approach was used to determine the appropriate mesh density for ceiling panel as shown in Figure 5. The bond between the steel reinforcement and concrete is assumed to be perfect. Newton-Raphson equilibrium method was used with load step increment of 1 seconds and nonlinear displacement convergence criteria of.1 mm. The results were generated for varying surface temperatures, across-depth distribution of which was determined based on the thermal conductivity coefficients of Table 1. The mechanical properties for concrete, reinforcing steel and polystyrene listed also in Table 1 were used to generate predictions for fire endurance. Table 1: Mechanical Properties of Materials Material Bottom Density, Tensile Compressive Modulus Poisson's Thermal Type concrete Kg/m 3 Stress, Stress, MPa of Ratio conductivity, layer MPa Elasticity, W/mK cover, mm MPa Concrete 5 15 3.1 25 1249.2.47 16 1376.53 17 157.6 18 16419.68 19 1786.77 2 1923.88 2 269.99 22 22186 1.13 225 22946 1.2 23 23715 1.28 235 24493 1.36 24 25279 1.45 245 2673 1.54 25 26875 1.64 55 23 23715 1.28 6 65 7 75 5 23 3.4 3 25978 3.7 35 286 3.9 4 29997 4.2 45 31817 4.4 5 33538 Reinforcing 78 394 394 2.3 43 Steel (3 mm) Reinforcing 78 59 59 2.3 43 Steel (8 mm) Polystyrene 1.5 34 ---- 3.34.8 Figure 5: Typical finte element meshing of ceiling panel Discussion and NLFEA Results The NLFEA was employed to estimate endurance time for a typical ceiling panel loaded to 5% of its ultimate load capacity while exposed to a fire regime of Figure 6. The result indicates that 39 minutes was needed to fail the panel, which is consistent with the time measured experimental and analytical values at about 36 minutes. The temperature-time regime generated by the NLFEA showed excellent agreement with the standard regime recommended by the ASTM. Therefore, no time correction is needed to adjust for the deviation of the temperature-time regime employed from the standard curve. 9 8 7 6 5 4 3 2 Standard Fire NLFEA Exposed Surface Inner-Exposed Surface Inner-Unexposed Surface Unexposed Surface 1 2 3 4 5 Figure 6: Temperature versus time regime adopted in the NLFEA analysis as compared to those obtained experimentally Effect of concrete density The results of Figure 7 gives a clear idea about the significance of using lightweight concrete in casting the present 3D ceiling panels. The curves pertaining to deflection and endurance time showed a decreasing trend as the density of concrete was increased and vice versa. It indicates that it is possible to double the endurance time for a ceiling panel by just replacing ordinary weight concrete by a lightweight concrete at a unit weight of about 15 kg/m 3 while keeping the strength the same. This would cost more as higher cement 788

content is needed to compensate for the use of the lower strength and lighter aggregates. 1.2 94 1.1 1. 53 49 44 1.1 1..9.8.7.6.5 y = -.5x + 1.7665 R 2 =.9942 y = 9E+6x -.8953 R 2 =.9984 86 79 71 63 55 47 39.9.8 4 36 31 27 22.7 18 2 25 3 35 4 45 5 55 Concrete strength, MPa.4 31 14 16 18 2 22 24 26 Concrete Density, Kg/m 3 Figure 7: Effect of concrete density on deflection and time to Effect of concrete cover Figure 8 shows the effect of concrete cover on the deflection and time to. Inspection of Figure 8 reveals that the time to failure increased sharply with the increase of concrete cover while the concrete cover had a diminutive impact on the deflection which decreased with the increase of concrete cover. 2.7 2.4 2.1 1.8 1.5 1.2.9 35 2. 2.5 3. 3.5 4. 4.5 5. 5.5 Concrete Cover, mm Figure 8: Effect of concrete cover on deflection and time to Effect of concrete strength Figure 9 shows the effect of concrete strength on the deflection and time to. Inspection of Figure 9 reveals that the concrete strength had a diverse strong impact on the deflection at failure and no impact on time to failure.. 14 96 87 78 7 61 52 43 Figure 9: Effect of concrete strength on deflection and time to Residual moment capacity versus exposure temperature The residual moment capacity versus exposure temperature was graphically presented in Figure 1. The theoretical temperature at failure that corresponded to 5% residual moment capacity was about 78 o C. This value is the same as the determined experimentally. The semi-linear behavior noticed after 6 o C is referred to the fact that the decrease in the moment capacity is dictated by the reduction in steel yield strength under high temperatures: the concrete in the compression zone was subjected to relatively low temperature that had no effect on its mechanical behavior. Figure 1 indicates that a temperature of 78 o C is needed to cause failure corresponding to endurance times of 42 and 36 minutes before and after correction, respectively. This means that the endurance times obtained experimentally and NLFEA results are matched. Percentage of Original Moment Capacity 11 9 8 7 6 5 4 3 2 1 2 3 4 5 6 7 8 9 Figure 1: Reduction in Moment capacity versus temperature 7881

CONCLUSION The ceiling panel, simulated as described herein, achieved a fire resistance rating of about 36 minutes, when tested and simulated as bearing assemblies with the fire applied against one surface using a mobile furnace, in accordance with ASTM Method E119 [11]. The fire test for the ceiling panel was terminated when the panel started showing uncontrolled deflection and the load set at 5% of its flexural capacity started decreasing. The NLFEA was very helpful in determining the extent by which concrete density can help extending the endurance time of a ceiling panel under fire. It indicates that it is possible to double the endurance time for a ceiling panel by just replacing ordinary weight concrete by a lightweight concrete at a unit weight of about 15 kg/m 3 while keeping the strength the same. This would cost more as higher cement content is needed to compensate for the use of the lower strength and lighter aggregates. The time to failure increased sharply with the increase of concrete cover while the concrete cover had a diminutive impact on the deflection which decreased with the increase of concrete cover. The concrete strength had a diverse strong impact on the deflection at failure and no impact on time to failure. [1] Rami H. Haddad. FIRE RESISTANCE TEST OF 3D SYSTEM WALL AND CEILING PANELS, Final Report prepared for Emirate Steel Limited, October 1, 29. [11] ASTM E119: Standard Test Methods for Fire Tests of Building Construction and Materials, Annual Book for Testing Materials, Ann Arbor, MI, 28. [12] ANSYS, ANSYS User s Manual Revision 9., ANSYS, Inc. [13] Hemmaty, Y. Modeling of the shear force transferred between cracks in reinforced and fiber reinforced concrete structures, Proceedings of the ANSYS Conference, Vol. 1, No. 1, 1998. [14] Huyse, L., Hemmaty, Y., and Vandewalle, L. Finite element modeling of fiber reinforced concrete beams, Proceedings of the ANSYS Conference, Vol. 2, No. 1, Pittsburgh, Pennsylvania, 1994. REFERENCES [1] Gruz, C. R. Elastic Properties of Concrete at High Temperature, Journal of the PCA Research and Development Laboratories, Vol. 8, No. 1, pp. 37-45, 1966. [2] Smith, E. E., and Harmathy, T.Z. Design of Building for Fire Safety, American Society for Testing and Materials, Philadelphia, 1979. [3] Carman, A. D. and Nelson, R. A. The thermal conductivity and diffusivity of concrete. Bulletin No. 122, pp. 32, Engineering Experimental Station, University of Illinois, Urbana, 1921. [4] Uddin, T. and Culver, C. G. Effect of Elevated Temperature on Structure Members, Journal of structural Div. ASCE, Vol. 11, pp. 1531-1549, 1975. [5] ACI Committee 216. Guide for determining the fire endurance of concrete elements, ACI 216-81. Concrete International, Vol. 3, pp. 13-47, 1981. [6] Kong, F. K., Evans, R. H., Cohen, E., and Rall, F. Handbook of Structural Concrete, McGraw-Hill, New York, 1983. [7] Hsu, J. H., Lin, C. S., and Hung, C. B. Modeling the Effective Elastic Modulus of RC Beams Exposed to Fire, Journal of Marine Science and Technology, Vol. 14, No. 2, pp. 1-7, 26. [8] Lin, T. D. Measured Temperature in Concrete Beams Exposed to ASTM E119 Standard Fire, Research and Development Report, Portland Cement Association, Skokie, 1985. [9] Numayr K., and Haddad, R. Static and dynamic analytical and experimental analysis of 3D reinforced concrete panels, Structural Engineering and Mechanics, Vol. 32, pp. 399-46, 29. 7882