6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05 CSH-06 CSH-07 CSH-08 CSH-09 CSH-10 CSH-11 CSH-12 CSH-13 CSH-14 CSH-15 CSH-16 CSH-17 CSH-18 CSH-19 CSH-20 CSH-21 CSH-22 CSH-23 CSH-24 CSH-25 INDEX STANDARD PANEL OFFERING STANDARD PANEL OFFERING SIDE LAP DETAILS SIDE LAP DETAILS WALL SECTIONS WALL SECTIONS WALL SECTIONS BASE DETAILS PARAPET DETAIL VERTICAL REVEALS VERTICAL REVEALS END LAP DETAIL HEAD OPENING DETAILS HEAD OPENING DETAILS JAMB OPENING DETAILS SILL OPENING DETAILS SILL OPENING DETAILS HEAD, JAMB, SILL INTERSECTION- HEAD, JAMB, SILL INTERSECTION-S END WALL DETAILS SOFFIT DETAILS OUTSIDE CORNER DETAILS INSIDE CORNER DETAILS OUTSIDE AND INSIDE CORNERS - MICROSEAM CSH-26 4 CORNER INTERSECTION CSH-27 PENETRATION (1 of 3) CSH-28 PENETRATION (2 of 3) CSH-29 PENETRATION (3 of 3) INDEX NOTE: DETAILS ARE FOR PROMOTIONAL USE ONLY. FOR COMPLETE DETAILS, REFER TO CENTRIA'S WEB SITE AT www.centria.com CSH-01
7 8 " [22] 7 8 " [22] 7 8 " [22] 7 8 " [22] EXTENDED FASTENING LEG OPTION 7 8 " [22] 16" [406] 16" [406] 16" [406] 1.6" [41] 5.6" [142] 5.6" [142] 9.6" [244] 16" [406] 16" [406] 16" [406] 16" [406] 2.4" [61] 5.6" [142] 7 8 " [22] 7 8 " [22] 5.6" [142] 9.6" [244] 5.6" [142] 4.0" [102] (TYP.) CS-660 CS-630 CS-623 CS-620 CS-660E CS-630E CS-623E CS-620E EXTENDED FASTENING LEG OPTION PANEL OFFERING CS-613 CS-612 CS-610 CS-613E CS-612E CS-610E CSH-02
EXTENDED FASTENING LEG OPTION 7 8 " [22] 7 8 " [22] 7 8 " [22] 7 8 " [22] 1.6" [41] 2.4" [61] 12" [305] 5.6" [142] 12" [305] 5.6" [142] 12" [305] 9.6" [244] 12" [305] CS-260 CS-220 CS-210 CS-200 CS-260E CS-220E CS-210E CS-200E PANEL OFFERING CSH-03
16"[406] NOMINAL COVERAGE 16"[406] NOMINAL COVERAGE CS-660 16"[406] NOMINAL COVERAGE 16"[406] NOMINAL COVERAGE CS-630 16"[406] NOMINAL COVERAGE 16"[406] NOMINAL COVERAGE CS-623 16"[406] NOMINAL COVERAGE CS-620 CS-660E CS-630E CS-623E CS-620E 16"[406] NOMINAL COVERAGE 16"[406] NOMINAL COVERAGE CS-613 SIDE LAPS CS-612 CS-610 CS-613E CS-612E CS-610E CSH-04
12"[305] NOMINAL COVERAGE 12"[305] NOMINAL COVERAGE 12"[305] NOMINAL COVERAGE 12"[305] NOMINAL COVERAGE 12"[305] NOMINAL COVERAGE CS-260 CS-220 CS-210 CS-200 CS-260E CS-220E CS-210E CS-200E SIDE LAPS CSH-05
= NOT BY CENTRIA DRAINED & VENTED CAVITY INTERIOR SHEATHING STUD CONCEPT SERIES PANEL INSULATION EXTERIOR SHEATHING CONCEPT SERIES CSC-1 OR CSC-2 CLIP BARRIER PANELS ON PROTECTED EXTERIOR SHEATHING WITH CAVITY INSULATION VAPOR RETARDER LOCATION THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS. THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION. DRAINED & VENTED CAVITY CONCEPT SERIES PANEL VERTICAL 3/4" [19] DEEP 16 GA. SUBGIRT VERTICAL SUPPORTS BARRIER CONCEPT SERIES CSC-3 CLIP FACTORY APPLIED LINER SEALANT FIELD-APPLIED (1.65 PCF) INSULATION IN LINER CAVITY HORIZONTAL LINER PANEL AIR BARRIER (LINER PANEL) PANELS WITH INSULATION IN HORIZONTAL LINER = NOT BY CENTRIA CSH-06
CONCEPT SERIES PANEL DRAINED & VENTED CAVITY CONCEPT SERIES CSC-1 OR CSC-2 CLIP AT METALWRAP PANEL JOINTS (3'-0" [914] O.C.) 3/4" SUBFRAMING AND AIR CAVITY METALWRAP INSULATED BACK-UP PANEL METALWRAP INSULATED BACK-UP PANEL "A" "A" METALWRAP AT EACH PANEL SIDE JOINT (36" O.C.) VERTICALLY AND INTO EACH FRAMING MEMBER (16" TO 24" O.C.) HORIZONTALLY SUBFRAMING FASTENER ANCHORED INTO CENTER OF METALWRAP CLIP SECTION A-A CONCEPT SERIES PANEL CONCEPT SERIES CLIP PANELS WITH METALWRAP INSULATED BACK-UP PANEL BARRIER = NOT BY CENTRIA DRAINED & VENTED CAVITY CONCEPT SERIES PANEL CONCEPT SERIES CSC-3 CLIP VERTICAL 3/4" [19] DEEP 16 GA. SUBGIRT CON'T. HORIZONTAL ZEE 16 [1.52] GA. MIN. (SPACING TO BE DETERMINED BY CLADDING ENGINEER) PANELS WITH INSULATION OUTBOARD OF STUD CAVITY INTERIOR SHEATHING STUD EXTERIOR SHEATHING BARRIER INSULATION SUITABLE FOR MOISTURE EXPOSURE VAPOR RETARDER LOCATION THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS. THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION. = NOT BY CENTRIA CSH-07
(*) CONTINUOUS VERTICAL ZEE SHAPED SUBGIRT (SHIM AS REQUIRED) (*) SUBGIRTS SHALL BE 1.) 16 GA. MINIMUM. 2.) 3/4" [19] MINIMUM DEPTH. 3.) 1/4" [6] DEEPER THAN INSULATION THICKNESS. 4.) SPACED AT 24" [610] OR 48"O.C. [1219] BASED ON DESIGN LOADS AND INSULATION SIZE. CONCEPT SERIES CSC-3 CLIP CONCEPT SERIES PANEL DRAINED & VENTED CAVITY MASONRY FASTENER PANELS WITH INSULATION OVER MASONRY WALL MASONRY INSULATION SUITABLE FOR MOISTURE EXPOSURE AIR BARRIER & WATER RESISTANT COATING OR MEMBRANE VAPOR RETARDER LOCATION THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS. THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION. = NOT BY CENTRIA CONCEPT SERIES PANEL WITH EXTENDED FASTENING LEG (NO CLIP REQUIRED) VERTICAL SUPPORTS FINISH IS REQUIRED ON BOTH SIDES OF THE PANEL SINCE BOTH SIDES ARE EXPOSED TO THE WEATHER PANELS USED AS A SCREEN WALL = NOT BY CENTRIA CSH-08
EXTERIOR SHEATHING BARRIER AND AIR BARRIER TAPE SUPPORT CLIP 3" [76] LONG @ STUD STUDS SP-4222 EXTEND WEATHER RESISTIVE BARRIER TO CURB AND SEAL CONTINUOUS STARTER FLASH CLR. 2" [51] CLR. T/CURB LOCATION OF BASE FLASH WILL VARY DUE TO CURB LOCATION & GRADE CLEARANCE REQUIRED. VARIES BASE at SLAB () (CS-6504B) FIELD MITER EXTERIOR SHEATHING BARRIER AND AIR BARRIER TAPE SUBGIRT CONTINUOUS STARTER FLASH STUDS NBC FIELD INSTALL SHIM TO ALLOW FOR DRAINAGE 1/8"[3]x1"[25]x2"[51] @ 18"[457] O.C. CURING BUTYL BASE at SLAB () (CS-6004) = NOT BY CENTRIA CSH-09
EXTEND WEATHER RESISTIVE BARRIER TO BACK SIDE OF PARAPET VARY 2"[51] MIN. SHIM FOR VENTING 12"[305] O/C ERECTOR NOTE: WOOD BLOCKING, ROOFING MEMBRANE, & SHEATHING RIVET NON-CURING BUTYL SUBGIRT EXTERIOR SHEATHING STUDS BARRIER PARAPET (CS-6012) = NOT BY CENTRIA CSH-10
12"[305] MAX. STUDS SP-4169 SP-4170 1" [25] 5" [127] WIDE VERTICAL REVEAL (RECESSED) () (CS-6505C) 12"[305] MAX. EXTERIOR SHEATHING BARRIER AND AIR BARRIER STUDS SP-4221 SP-4220 5/8" [16] 3 5/8" [92] EXTERIOR SHEATHING BARRIER AND AIR BARRIER NARROW VERTICAL REVEAL (RECESSED) () (CS-6505E) = NOT BY CENTRIA CSH-11
STUDS NON-CURING BUTYL EXTERIOR SHEATHING BARRIER METAL AND COMPOSITION CLOSURES SP-4173 5" [127] VERTICAL REVEAL (FLAT) () (CS-6505D) SP-4169 STUDS BARRIER NON-CURING BUTYL EXTERIOR SHEATHING METAL AND COMPOSITION CLOSURE 2 1 2 "[64] MIN. 1"[25] MIN. VERTICAL REVEAL () (CS-6005B) = NOT BY CENTRIA CSH-12
STUDS EXTERIOR SHEATHING "A" BARRIER AND AIR BARRIER 7/8"[22] x 6"[152] LONG CLOSED CELL BACKER ROD (1 ROW) NON-CURING BUTYL "A" 2"[51] LAP RIVET 4" O.C. CONCEPT SERIES CLIP END LAP DETAIL (22 [.76] AND 24 [.60] GAGES ONLY) NOTE: THIS DETAIL USED ON WALLS WITHOUT MICROLINE S FIELD APPLIED SEALANT 7/8"[22] x 6"[152] LONG CLOSED CELL BACKER ROD SECTION "A-A" END LAP DETAIL ISOMETRIC (CS-6005) NOTE: THE MAXIMUM CUMULATIVE LENGHT OF LAPPED PANELS IS 60'-0" FOR STEEL AND 30'-0" FOR ALUMINUM PANELS. SPECIFIC DETAILS MUST BE USED THAT WILL ACCOMMODATE THERMAL MOVEMENT. FOR PANEL RUNS WITH MULTIPLE PANELS, PROVIDE A FIXING POINT AT THE CENTER OF EACH PANEL RUN PER DETAIL CC-6027 OR CS-6027. = NOT BY CENTRIA CSH-13
BARRIER AND AIR BARRIER FIELD APPLIED BULB-WEATHER STRIP SP-4143 STUDS EXTERIOR SHEATHING TAPE CURING BUTYL EXTEND BARRIER CLEAR OPNG. HEAD OPENING (HIGH CELL) () (CS-6500) PRIMARY AIR SEAL DOOR, WINDOW OR LOUVER SHIM AS REQUIRED EXTEND BARRIER SUBGIRTS 1 8 "[3] GAP 2" [51] SP-4141 NON-CURING BUTYL WEATHER SEAL EXTERIOR SHEATHING STUDS BARRIER AND AIR BARRIER TAPE WEATHER SEAL HEAD OPENING (HIGH CELL) ( ) (CS-6000) PRIMARY AIR SEAL DOOR, WINDOW OR LOUVER = NOT BY CENTRIA CSH-14
STUDS BARRIER AND AIR BARRIER 18[1.21] GAGE SUPPORT CLIP, 3"[76] LONG @ STUD SP-4142 FIELD APPLIED BULB-WEATHER STRIP SP-4143 EXTERIOR SHEATHING TAPE CURING BUTYL SHIM AS REQUIRED 2" [51] EXTEND BARRIER PANEL MODULE SP-4141 WEATHER SEAL EXTERIOR SHEATHING 18[1.21] GAGE SUPPORT CLIP, 3"[76] LG. @ STUD STARTER FLASH SP-4142 FIELD APPLIED BULB-WEATHER STRIP SP-4143 HEAD OPENING (LOW CELL) () (CS-6500A) PRIMARY AIR SEAL DOOR, WINDOW OR LOUVER STUDS BARRIER AND AIR BARRIER TAPE CURING BUTYL SHIM AS REQUIRED 2" [51] EXTEND BARRIER SP-4141 WEATHER SEAL HEAD OPENING (ON MODULE) () (CS-6500B) PRIMARY AIR SEAL DOOR, WINDOW OR LOUVER = NOT BY CENTRIA CSH-15
CURING BUTYL TAPE BARRIER AND AIR BARRIER EXTERIOR SHEATHING 12"[305] MAX. STUDS EXTEND WEATHER RESISTIVE BARRIER PRIMARY AIR SEAL SHIM AS REQUIRED DOOR, WINDOW OR LOUVER WEATHER SEAL TAPE EXTERIOR SHEATHING SP-4141 SP-4143 2" [51] JAMB OPENING () (CS-6503) STUDS EXTEND WEATHER RESISTIVE BARRIER PRIMARY AIR SEAL DOOR, WINDOW OR LOUVER WEATHER SEAL BARRIER WEATHER SEAL 2 1 2 " [64] MIN. JAMB OPENING () (CS-6003) METAL AND COMPOSITION CLOSURES = NOT BY CENTRIA CSH-16
SP-4141 SP-4145 2" [51] WEATHER SEAL SHIM AS REQUIRED WINDOW OR LOUVER PRIMARY AIR SEAL STUDS BARRIER TAPE EXTERIOR SHEATHING SILL OPENING (LOW CELL) () (CS-6506A) WEATHER SEAL SHIMS FOR VENTING 12"[305]O/C WINDOW OR LOUVER PRIMARY AIR SEAL EXTEND WEATHER RESISTIVE BARRIER SUBGIRT BARRIER EXTERIOR SHEATHING SILL OPENING (LOW CELL) () (CS-6007) STUDS = NOT BY CENTRIA CSH-17
WEATHER SEAL 1 4 "[6] 2" [51] CURING BUTYL TAPE SP-4145 SHIM AS REQUIRED WINDOW OR LOUVER PRIMARY AIR SEAL EXTEND WEATHER RESISTIVE BARRIER SP-4141 EXTERIOR SHEATHING BARRIER STUDS SILL OPENING (HIGH CELL) () (CS-6506) DESIGN MAY VARY DUE TO PANEL MODULE LAYOUT WINDOW OR LOUVER SHIMS FOR VENTING 12"[305] O/C WEATHER SEAL STUDS EXTEND WEATHER RESISTIVE BARRIER PRIMARY AIR SEAL SUBGIRT EXTERIOR SHEATHING BARRIER AND AIR BARRIER SILL OPENING (HIGH CELL) () (CS-6006) = NOT BY CENTRIA CSH-18
INTERSECTION OF HEAD, JAMB & SILL (CS-6516) = NOT BY CENTRIA CSH-19
INTERSECTION OF HEAD, JAMB & SILL FLASH (CS-6016) = NOT BY CENTRIA CSH-20
STUDS 12"[305] MAX. EXTERIOR SHEATHING BARRIER NON CURING BUTYL FIELD-APPLIED CONTINUOUS BEAD IN RETAINER POCKET TAPE SP-4141 POLYURETHANE & BACKER ROD METAL AND COMPOSITION CLOSURES SP-4144 END WALL () (CS-6508) 2" [51] TAPE STUDS EXTERIOR SHEATHING BARRIER 1"[25]CLR. E/PANEL EXTEND WEATHER RESISTIVE BARRIER END WALL () (CS-6008) 2 1 2 " [64] MIN. METAL AND COMPOSITION CLOSURES = NOT BY CENTRIA CSH-21
BARRIER AND AIR BARRIER TAPE SUBGIRT EXTERIOR SHEATHING STUDS METAL AND COMPOSITION CLOSURES 1 8 "[3]GAP 2 1 2 "[64] MIN. METAL AND COMPOSITION CLOSURE SOFFIT - FRONT () (CS-6013) 1 8 "[3] GAP OPTIONAL DETAIL @ SOFFIT 2 1 2 "[64] MIN. EXTERIOR SHEATHING STUDS SUBGIRT BARRIER SOFFIT - BACK () (CS-6014) = NOT BY CENTRIA CSH-22
SP-4172 SP-4171 STUDS BARRIER TAPE SP-4141 1'-0"[305] MAX. OPTIONAL S EXTERIOR SHEATHING BARRIER 2" [51] SP-4144 METAL AND COMPOSITION CLOSURE OUTSIDE CORNER () (CS-6509) EXTERIOR SHEATHING BARRIER STUDS METAL AND COMPOSITION CLOSURE ALTERNATE (CS-6009) 2 1 2 "[64] MIN. OUTSIDE CORNER () (CS-6009A) = NOT BY CENTRIA CSH-23
STUDS EXTERIOR SHEATHING 12"[305] MAX. BARRIER TAPE SP-4141 SP-4144 INSIDE CORNER () (CS-6510A) STUDS METAL AND COMPOSITION CLOSURE BARRIER 2 1 2 "[64] MIN. EXTERIOR SHEATHING INSIDE CORNER () (CS-6010) = NOT BY CENTRIA CSH-24
EXTERIOR SHEATHING BARRIER AND AIR BARRIER STUDS 74 Min. 135 Max. 2"[51] LAP 24"[610] (STANDARD) 15"[381] MINIMUM, 42"[1067] MAXIMUM TYPICAL OVERLAP DETAILS FOR 22[0.76] OR 24[0.60] GAGE PANELS ONLY. 2"[51] LAP OUTSIDE CORNER MICROSEAM (CS-6017) SHOP ASSEMBLED MITERED CORNER BARRIER AND AIR BARRIER EXTERIOR SHEATHING 74 Min. 135 Max. SHOP ASSEMBLED MITERED CORNER 2"[51] LAP STUDS 24"[610] (STANDARD) 15"[381] MINIMUM, 42"[1067] MAXIMUM INSIDE CORNER MICROSEAM (CS-6018) = NOT BY CENTRIA CSH-25
* SEE DETAIL CS-6005 FOR A TYPICAL LAP ISOMETRIC VIEW TYPICAL HORIZONTAL PANEL ERECTION PROCEDURE (REFER TO DIAGRAM "A" BELOW FOR ERECTION SEQUENCE) NOTE: AFTER LAPPING PANEL~B OVER PANEL~A, THE A & B PANEL CLIP MUST BE INSTALLED PRIOR TO PANEL~C BEING INSTALLED. THIS PROCEDURE SHALL BE TYPICAL FOR ALL SUBSEQUENT PANELS. L I K M F H J C E G A B D DIAGRAM "A" (BUILDING ELEVATION) FOUR CORNER INTERSECTION (CS-6019) = NOT BY CENTRIA CSH-26
PENETRATION DETAIL (CS-6015) NOTE:- REF. PAGE CSH-26 FOR SECT. A-A REF. PAGE CSH-27 FOR SECT. B-B = NOT BY CENTRIA CSH-27
STUDS EXTERIOR SHEATHING BARRIER AND AIR BARRIER TAPE SUBGIRT 1 8 "[3"]GAP FLAT SUBGIRT POLYURETHANE (TYPICAL ALL AROUND) TAPE SECTION A-A (CS-6015A) PENETRATION DETAIL = NOT BY CENTRIA CSH-28
STUDS METAL AND COMPOSITION CLOSURES TAPE SUBGIRT FLAT POLYURETHANE SEALANT ALL AROUND EXTERIOR SHEATHING BARRIER AND AIR BARRIER SECTION B-B (CS-6015B) PENETRATION DETAIL = NOT BY CENTRIA CSH-29