Brick Veneer Walls. Insulation

Similar documents
Double Brick Cavity Walls

Timber-framed Walls. Insulation

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

Permicav XV TM NEXT GENERATION OF VAPOUR-PERMEABLE INSULATION FOR WALLS WITH CAVITIES

A4/8 PS AW2324D Issue 10 May Permishield

K12 Framing Board. Insulation

A4/8 PS AW2002 Issue 6 Sept Permishield

Permifloor. Insulation WATER-PERMEABLE UNDERFLOOR INSULATION

Insulbreak. Insulation. thermal break solution

K18 Insulated Plasterboard

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION

K8 Cavity Board. Insulation CAVITY WALL INSULATION

Permifloor. Insulation WATER-PERMEABLE UNDERFLOOR INSULATION

A4/6 PS AW1551 Issue 4 Nov Permishield

K17 Insulated Plasterboard

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION

K17 Insulated Plasterboard

Permifloor. Insulation WATER-PERMEABLE UNDERFLOOR INSULATION

Insulbreak. Insulation. thermal break solution

K17 Insulated Plasterboard

K3 Floorboard. Insulation INSULATION FOR FLOORS

K5 External Wall Board

Insuliner. Insulation REFLECTIVE INSULATION FOR USE WHERE

K3 Floorboard. Insulation INSULATION FOR FLOORS

Soffit Board. Insulation

K15 Rainscreen Board. Insulation INSULATION FOR USE BEHIND RAINSCREEN CLADDING SYSTEMS

K5 External Wall Board

K10 FM Soffit Board. Insulation

TR26 LPC/FM / TR27 LPC/FM

Fire Safety Compliance Guide: Wall and Ceiling Linings

TR26 LPC/FM / TR27 LPC/FM

TR26 LPC/FM. Insulation INSULATION FOR FLAT ROOFS WATERPROOFED WITH MECHANICALLY FIXED SINGLE PLY WATERPROOFING

Concrete Soffit Direct Fix

Fire Safety Compliance Guide: Wall and Ceiling Linings

K12 Framing Board INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS. P E R F O R M A N C E Manufactured to BS EN ISO 9002: 1994 Certificate No.

Product Catalogue

K12 Framing Board INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS P E R F O R M A N C E

TR27 LPC/FM. Insulation

SOLITEX EXTASANA WALL PROTECTION MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 822 [2013] Appraisal No. 822 (2013) Amended 06 May 2014

National Construction Code Series (NCC) Building Code of Australia (BCA)

K17 Insulated Plasterboard

K10 FM Soffit Board. Insulation INSULATION FOR STRUCTURAL CEILINGS (SOFFITS) Low Energy Low Carbon Buildings. agent that has zero ODP and low GWP

wall TW50 zero ODP PARTIAL FILL CAVITY WALL INSULATION For more information on Kingspan Insulation visit

K15 Cladding Board. Insulation INSULATION FOR USE BEHIND CLADDING SYSTEMS. Low Energy Low Carbon Buildings. Third Issue July 2017

K5 EWB. Insulation INSULATION FOR USE BEHIND TRADITIONAL AND LIGHTWEIGHT POLYMER MODIFIED RENDERS P E R F O R M A N C E

K12 Framing Board. I n s u l a t i o n. Low Energy Low Carbon Buildings

wall underlay Product BRANZ APPRAISAL No. 695 (2010) Scope Thermakraft Industries (NZ) Ltd PO Box Botany Manukau 2163 Auckland

Thermal Laminate Board.

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

K8 Cavity Board. Insulation PARTIAL FILL CAVITY WALL INSULATION P E R F O R M A N C E BBA BRITISH

Superior Performance Phenolic Insulation. SR/FB Insulation for Steel and Timber Frame. Walls AS LOW AS 10/4803

Superior Performance Phenolic Insulation. SR/FB Insulation for Steel and Timber Frame. Walls AS LOW AS 10/4803

Insulation. A4/6 AW2242 Issue 1 Oct Kingspan Insulation


Sarking & Insulation Products A Blue Chip Company

K15 Rainscreen Board. Insulation INSULATION FOR USE BEHIND RAINSCREEN CLADDING SYSTEMS P E R F O R M A N C E

Insulation. Second Issue November Quick Guide. Building a better Kingdom together. Low Energy Low Carbon Buildings

K12 Framing Board. Insulation INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS P E R F O R M A N C E

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

USG BORAL WET AREA SYSTEMS. Product. Scope. Building Regulations. Appraisal No. 955 (2017) BRANZ Appraisals

RENDERED WALL SYSTEM. Combining exterior cladding with superior insulation

K2 Roofboard INSULATION BENEATH FULLY ADHERED SINGLE-PLY WATERPROOFING USING SOLVENT BASED ADHESIVES P E R F O R M A N C E

WATERGATE-PLUS 295 FIRE RETARDANT WALL UNDERLAY. Product. Scope. Appraisal No. 695 [2017]

KOOLTHERM K12 FRAMING BOARD AND K15 RAINSCREEN BOARD BCA Certificate number: CM Date of issue: 15/08/2017. Date of expiry: 21/03/2020

Superior Performance PIR Insulation. XO/FB Insulaton for Steel & Timber Frame. Walls 12/4956

K15 Rainscreen Board. I n s u l a t i o n EP E R F O R M A N C. Low Energy - Low Carbon Buildings

Eco-Versal. insulation. Polyisocyanurate (PIR) foam core with aluminium foil composite to both sides BASELINE TOPLINE SLIMLINE

Soffit Board. Insulation INSULATION FOR STRUCTURAL CEILINGS (SOFFITS) Low Energy Low Carbon Buildings. CI/SfB. (45) Rn7 M2 Second Issue October 2016

K10 Soffit Board. I n s u l a t i o n. Low Energy Low Carbon Buildings

Soffit Board. Insulation INSULATION FOR STRUCTURAL CEILINGS (SOFFITS) Low Energy Low Carbon Buildings. CI/SfB. (45) Rn7 M2 Fifth Issue May 2018

Superior Performance PIR Insulation XO/FB. Insulaton for Steel & Timber Frame. Walls 12/4956

Multi-layer Insulation Blanket for Walls

Kingspan Kooltherm K10, K10 Plus & K15 Insulation Products

POLTERM MAX PLUS. Non combustible stone wool insulation for ventilated rainscreen cladding and overcladding systems. isover.co.uk

TW55. Insulation INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS

CI/Sfb (2 ) Rn7 M2 Fourth Issue June Product Selector INSULATION FOR ROOFS, WALLS & FLOORS. Low Energy Low Carbon Buildings

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

K10 FM Soffit Board. I n s u l a t i o n. Low Energy Low Carbon Buildings


Insulation for Ventilated Rainscreen Cladding Systems

Multi-layer Insulation Blanket for Walls

Insulation. A4/8 KDINT AW2143 Issue 4 Oct An Introduction

Cembrit Windstopper Basic Cembrit Windstopper Extreme

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.

Don t leave money on the floor.

Light steel frame walls

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

URSA TF Roll URSA GLASSWOOL.

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

K12 Framing Board. Insulation INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS P E R F O R M A N C E

INSTALLATION GUIDE EPS FOAM

Multi-layer Insulation Blanket for

K5 EWB. Insulation INSULATION FOR USE BEHIND TRADITIONAL AND LIGHTWEIGHT POLYMER MODIFIED RENDERS P E R F O R M A N C E

K5 External Wall Board

Multi-layer Insulation Blanket for Walls

GA APPLICATION OF GYPSUM SHEATHING

Heavy Duty Floors. I n s u l a t i o n. Low Energy Low Carbon Buildings

FOCAL POINT RENDAPANEL TM CLADDING SYSTEM

Transcription:

Insulation A4/8 BV AW2157 Issue 7 Nov 2016 Brick Veneer Walls Insulation guide Helps achieve a 6-star house energy rating Rigid Kingspan Kooltherm and flexible Kingspan AIR-CELL solutions available Fibre-free, non-allergenic, non-irritant solutions available Quick and easy to install Solutions available that act as a temporary weather barrier prior to wall cladding being fixed Strong, tough, durable Rodent and insect resistant Compliant with AS/NZS 4859.1 CodeMark-certified for BCA compliance SAIG-CM 20029 SAIG-CM 20045 SAIG-CM 20048

AIR-CELL Permicav XV TM Typical Design Detail Timber stud Plasterboard lining Kingspan AIR-CELL Permicav XV TM Internal stud frame Kingspan AIR-CELL Permicav XV TM Face brickwork Plasterboard lining Timber framework Brick facing Figure 1 Kingspan AIR-CELL Permicav XV TM in brick veneer wall installation Thermal Performance Brick Veneer Wall Heat flow in Heat flow out Kingspan AIR-CELL Permicav XV TM R T 1.7 R T 1.9 The R-values shown are Total R-values for the building element as required by the Energy Provisions of the Building Code of Australia. Kingspan AIR-CELL products are manufactured, tested and packaged in conformance with AS/NZS 4859.1. The contribution of the product Total R-values depends on installation and environmental conditions. Specification Guide The wall insulation fixed to the outside of the stud frame shall be Kingspan AIR-CELL Permicav XV TM fibre-free, thermo reflective insulation, comprising a cross-linked, closed-cell foam core sandwiched with an anti-glare foil facing on one side and a plain foil facing on the other side manufactured by Kingspan Insulation Pty Ltd, and shall be installed in accordance with the instructions issued by them. Figure 2 Side elevation of Kingspan AIR-CELL Permicav XV TM in a brick veneer wall Installation Instructions 1. Roll out Kingspan AIR-CELL Permicav XV TM horizontally and fix to outside of internal wall frame, working from the bottom up. 2. Allow 50 mm overlap between top and bottom layers and tape with 48 mm reinforced foil tape (please refer to brochure Kingspan Insulation Tape for further information). 3. Cut Kingspan AIR-CELL Permicav XV TM fully around doors, windows and other openings, so that it neatly abuts to frames. 4. Penetrations for wall ties or services should be neatly cut to minimize gaps. A Project Specific Warranty provided by Kingspan Insulation must be submitted. Scan to see the installation video 2

K12 Framing Board Typical Design Detail Timber stud Kingspan Kooltherm K12 Framing Board Mechanical fixings Wall Tie Brick Wall Airspace Kingspan Kooltherm K12 Framing Board Airspace (created by Stud) Plasterboard Figure 3 Kingspan Kooltherm K12 Framing Board in brick veneer wall installation Figure 4 Side elevation of Kingspan Kooltherm K12 Framing Board in a brick veneer wall Thermal Performance Product Thickness Heat flow in Heat flow out 25 mm R T 2.9 R T 3.1 30 mm R T 3.1 R T 3.3 The R-values shown are Total R-values for the building element as required by the Energy Provisions of the Building Code of Australia. Kingspan Kooltherm products are manufactured, tested and packaged in conformance with AS/NZS 4859.1. The contribution of the product Total R-value depends on installation and environmental conditions. Specification Guide The wall insulation fixed to the outside of the stud frame shall be Kingspan Kooltherm K12 Framing Board mm thick, with a tested smoke obscuration of not more than 100 m 2 /kg, comprising a CFC/HCFC-free and zero Ozone Depletion Potential (ODP) rigid thermoset phenolic insulation core with composite foil facings on both sides manufactured under a management system certified to BS / I.S.EN ISO 9001:2008, BS / I.S.EN ISO 14001:2004 and BS / I.S. OHSAS 18001:2007 by Kingspan Insulation Pty Ltd and shall be installed in accordance with the instructions issued by them. Installation Instructions 1. Ensure that stud spacings do not exceed 600 mm centres. 2. Attach appropriate wall ties to frame at spacings required for the masonry external leaf. 3. Fix Kingspan Kooltherm K12 Framing Board to the external surface of the frame structure ensuring vertical board joints coincide with a vertical member. 4. Ensure that the boards are lightly butted and continuity of insulation is maintained. 5. Use large headed galvanised clout nails or screws as fixings prior to the insulation boards being tied to the frame with an appropriate timber frame wall tie and insulation retaining disc. 6. Ensure that fixings are coincident with the underlying timber studs, top and bottom wall plates. 7. Construct the outer leaf of masonry in the conventional manner, using appropriate wall ties to hold the two wall leaves together. A Project Specific Warranty provided by Kingspan Insulation must be submitted. 3

K18 Insulated Plasterboard Typical Design Detail Timber stud Brick veneer Sarking Kingspan Kooltherm K18 Insulated Plasterboard Specification Guide Kingspan Kooltherm K18 Insulated Plasterboard Figure 5 Kingspan Kooltherm K18 Insulated Plasterboard mechanically fixed to timer framing Thermal Performance Product Thickness Heat flow in Heat flow out (inc. Plasterboard) 35 mm R T 2.2 R T 2.3 40 mm R T 2.5 R T 2.6 50 mm R T 3.1 R T 3.1 60 mm R T 3.6 R T 3.6 70 mm R T 4.1 R T 4.2 80 mm R T 4.6 R T 4.7 90 mm R T 5.1 R T 5.2 The R-values shown are Total R-values for the building element as required by the Energy Provisions of the Building Code of Australia. Kingspan Kooltherm products are manufactured, tested and packaged in conformance with AS/NZS 4859.1. The contribution of the product Total R-value depends on installation and environmental conditions. The wall dry-lining insulation shall be Kingspan Kooltherm K18 Insulated Plasterboard mm thick, with a tested smoke obscuration of not more than 100 m 2 /kg, comprising a CFC/HCFC free and zero Ozone Depletion Potential (ODP) rigid thermoset phenolic insulation core with 10 mm plasterboard facing bonded to its front surface and a composite foil facing on its reverse surface, manufactured under a management system certified to BS / I.S. EN ISO 9001:2008, BS / I.S. EN ISO 14001:2004 and BS / I.S. OHSAS 18001:2007 by Kingspan Insulation Pty Ltd and shall be installed in accordance with the instructions issued by them. Figure 6 Side elevation - Brick veneer wall with Kingspan Kooltherm K18 Insulated Plasterboard Installation Instructions Kingspan Kooltherm K18 Insulated Plasterboard must be installed in accordance with AS/NZS 2589:2007 Gypsum linings Application and finishing. Mechanical Fixing to Vertical Timber / Battens / Metal Stud and Track This method may be used on timber frame, metal stud and track constructions or on any dry masonry wall that will support and retain the battens and associated fixings. 1. Place framing / battens at a maximum of 600 mm centres and positioned horizontally at floor and ceiling level / horizontal joints to support the Kingspan Kooltherm K18 Insulated Plasterboard. 2. Ensure the framing/ battens will be wide enough to offer a minimum 20 mm support to all edges of the board. 3. Use plasterboard screws long enough to allow for a minimum 20 mm embedment into the stud or, alternatively, suitable galvanised plasterboard nails, should be placed at 200 mm centres and not less than 10 mm from the edges of the board along the line of the studs. 4. Drive fixings straight and embed heads just below the surface of the board. Care should be taken not to overdrive the fixing. 5. Screws used for plasterboard fixing must comply with AS 3566.2:2002 self-drilling screws complying with the building and construction industry corrosion resistance requirements. A Project Specific Warranty provided by Kingspan Insulation must be submitted. 4

Combination System K18 Insulated Plasterboard + AIR-CELL Permicav XV TM Typical Design Detail Timber stud Kingspan Kooltherm K18 Insulated Plasterboard Kingspan AIR-CELL Permicav XV TM Kingspan Kingspan AIR-CELL Permicav XV TM Kingspan Kooltherm K18 Insulated Plasterboard Figure 8 Side elevation - Brick Veneer Wall with Combination System Kingspan Kooltherm K18 Insulated Plasterboard + Kingspan AIR-CELL Permicav XV TM Figure 7 Combination System Kingspan Kooltherm K18 Insulated Plasterboard + Kingspan AIR-CELL Permicav XV TM Thermal Performance Combination System Kingspan Kooltherm K18 Insulated Plasterboard + Kingspan AIR-CELL Permicav XV TM Kooltherm K18 Thickness (inc. Plasterboard) Heat flow in Brick facing 35 mm R T 3.0 R T 3.2 40 mm R T 3.2 R T 3.5 50 mm R T 3.7 R T 4.0 60 mm R T 4.4 R T 4.6 70 mm R T 4.9 R T 5.1 80 mm R T 5.4 R T 5.6 90 mm R T 5.9 R T 6.1 Heat flow out Installation Instructions For Kingspan AIR-CELL Permicav XV TM installation instructions refer to page 2. For Kingspan Kooltherm K18 Insulated Plasterboard installation instructions refer to page 4. The R-values shown are Total R-values for the building element as required by the Energy Provisions of the Building Code of Australia. Kingspan AIR-CELL and Kingspan Kooltherm products are manufactured, tested and packaged in conformance with AS/NZS 4859.1. The contribution of the product Total R-value depends on installation and environmental conditions. 5

General Requirements Cutting 1. Fit Kingspan AIR-CELL neatly around doors, windows, and any penetrations, and tape if necessary to prevent air leakage. 2. Foil facings are conductive to electricity and contact with uninsulated electrical cables and fittings must be avoided. 3. When taping a plastic squeegee or blade must be used to apply appropriate pressure to the tape. Surfaces must be dry and free from dust, oil or grease prior to taping. 4. Leave minimum 50 mm clearance around heat producing flues or light fittings (refer to light fitting manufacturer). The instructions in this document are guidelines only and should be interpreted with consideration for the specific building design. The installation of Kingspan AIR-CELL should be in conformance with the applicable clauses from AS 3999 and AS/NZS 4200.2 unless otherwise specified. Kingspan AIR-CELL can be damaged by intense heat above 105 C and contact with sparks and flame from blow torches, welders, cutting tools, etc. must be avoided. The installer must make due provision for safety when installing Kingspan AIR-CELL and Kingspan Kooltherm in any application. Cutting of Kingspan Kooltherm boards should be carried out either by using a fine toothed saw, or by scoring with a sharp knife, snapping the board over a straight edge and then cutting the facing on the other side. Ensure accurate trimming to achieve close-butting joints and continuity of insulation. Please note that scoring and snapping would not apply to Kingspan Kooltherm K18 Insulated Plasterboard due to the bonded plasterboard lining. Handling and Storage Kingspan AIR-CELL insulation products must be transported and stored in its protective packaging and kept clean and dry. Standing rolls on end reduces risk of damage should moisture be present in the packaging. Surfaces must be kept free of contaminants such as dust and grease, and must not be stored with foil surfaces in contact with alkaline materials i.e. wet cement, lime, etc. The packaging of Kingspan Kooltherm should not be considered adequate for long term outdoor protection. Ideally boards should be stored inside a building. If, however, outdoor storage cannot be avoided then the boards should be stacked clear of the ground and covered with an opaque polythene sheet or weatherproof tarpaulin. Boards that have been allowed to get wet should not be used. 6

7

Contact Details General Enquiries Tel: 1300 247 235 Email: info@kingspaninsulation.com.au Kingspan Insulation Pty. Ltd. reserves the right to amend product specifications without prior notice. The information, technical details and fixing instructions etc. included in this literature are given in good faith and apply to uses described. Recommendations for use should be verified as to the suitability and compliance with actual requirements, specifications and any applicable laws and regulations. For other applications or conditions of use, Kingspan Insulation offers a Technical Advisory Service the advice of which should be sought for uses of Kingspan Insulation products that are not specifically described herein. Please check that your copy of the literature is current by contacting us or visiting www.kingspaninsulation.com.au Kingspan Insulation Pty Ltd Tel: 1300 247 235 Email: info@kingspaninsulation.com.au www.kingspaninsulation.com.au Kingspan, Kooltherm, Air-Cell, the zo Device and the Lion Device are Registered Trademarks of the Kingspan Group plc in Australia and other countries. All rights reserved. Kingspan Insulation Pty Ltd