(CEMS) Sanjeev K Kanchan. Centre for Science and Environment

Similar documents
Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions

Monitoring Quick Guide 3

Lars K. Gram. FORCE Technology. The Danish EPA's Reference Laboratory for Air Emission Monitoring.

CEM Istanbul, 14 th May 2014

Method Implementation Document (MID 14181) EN 14181: Stationary source emissions Quality assurance of automated measuring systems

DAILY LIFE of CEMS QA & PM

QAL3 methods for different measurement principles from the point of view of AMS manufacturers, test houses and plant operators

Guido Baum Dr. Peter Wilbring

Technical Guidance Note (Monitoring) Monitoring of stack gas emissions from medium combustion plants and specified generators

Proposed Data Acquisition & Handling System for Pilot Emission Trading Scheme in India

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT COMPLIANCE DEPARTMENT COM 2025

EN14181 Stationary Source Emissions Quality Assurance of Automated Measuring Systems

AAETI Anil Agarwal Environment Training Institute SELF- INSPECTION

Predictive Emissions Monitoring Systems (PEMS) What You Need to Know

CEMS FOR COAL FIRED POWER STATIONS DEVICE CALIBRATION AND MAINTENANCE

The guidance represents the views of the Commission services at the time of publication. It is not legally binding.

Quality assurance of automated measuring systems

PRODUCT CONFORMITY CERTIFICATE

Application of EN14181 and EN15267 to Electronic Noses: Challenge or Provocation?

The development of instrumentation for application to carbon capture and storage measurements

Introduction and Agenda

data systems CEM International Conference and Exhibition on Emissions Monitoring

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE This is to certify that the

Review of ConocoPhillips Alaska Inc. Continuous Emissions Monitoring Data from a 2014 Drill Rig Study at Kuparuk Drill Site 2N

PRODUCT CONFORMITY CERTIFICATE

EPA vs. EN standards

PRODUCT CONFORMITY CERTIFICATE

An Overview of Mercury Monitoring Options

AIR EMISSION PERMIT NO ADMINISTRATIVE AMENDMENT IS ISSUED TO. Northern States Power Company

Guidance Book 2017 (1)

PRODUCT CONFORMITY CERTIFICATE

Performance Standards for Indicative Ambient Particulate Monitors Environment Agency July 2012 Version 2

Charter for Water Recycling & Pollution Prevention in Pulp & Paper Industries. (Specific to Ganga River Basin States)

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

L 24/18 Official Journal of the European Union

Landfill Project Protocol Version 4.0 ERRATA AND CLARIFICATIONS

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE This is to certify that the

Your ref.: Our ref.: Date: CDM Ref 1443 YKK/TRIKA/MLEH 19 January 2008

Truth-telling by third party auditors and the response of polluting firms: Experimental Evidence from Gujarat, India

ROP - CAM EXAMPLE TABLE NOTE: THIS TEMPLATE IS NOT AN OUTLINE FOR A CAM PLAN

AIR EMISSION PERMIT NO IS ISSUED TO. LSP - Cottage Grove LP

Nitric Acid Production Project Protocol Version 1.0 ERRATA AND CLARIFICATIONS

PRODUCT CONFORMITY CERTIFICATE

Chapter 10 Inspecting Combustion Sources

Inspecting Combustion Sources

Developments in Biomass and Waste Emissions Regulation

PRODUCT CONFORMITY CERTIFICATE This is to certify that the

PRODUCT CONFORMITY CERTIFICATE

Comparison Continuous Emission Monitoring Techniques

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

Title: Standard Operating Procedure for the Continuous Measurement of Ambient PM using a Beta Attenuation Monitor

Regulatory position paper on sulphur dioxide monitoring, comparing portable-instrumental techniques with manual methods

CASE STUDIES OF DUST AMS CALIBRATION AT EXTREME CONDITIONS

Ambient Air Quality and noise Measurements Report Gas pressure reduction station in Marsa Matrouh Governorate

PRODUCT CONFORMITY CERTIFICATE

CPCB/e - P U B L I C A T I O N /

Procedure Z: Quality Assurance Requirements for X-Ray-Fluorescence Based Multi-Metals Continuous Emission Monitoring Systems at Stationary Sources

Company Y Facility Z. Sample January 2019 Monthly Industrial Air Monitoring Report. EPEA Approval Number

NSPS Subpart OOOO Overview

Southwest Clean Air Agency NE 99 th St, Suite 1294, Vancouver, WA 98682

Ambient Air Quality Monitoring

CPCB/e - P U B L I C A T I O N /

Company Y Facility Z. Sample 2018 Annual Industrial Air Monitoring Report. EPEA Approval Number March 2019

PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT.

Measurement and Reporting of Vapor Phase Mercury Emissions from Low-Emitting Stationary Sources (DRAFT 9/25/08)

PRODUCT CONFORMITY CERTIFICATE

Company Y Facility Z. Sample 2018 Annual Industrial Air Monitoring Report. EPEA Approval Number March 2019

Supplemental Environmental Project: Third Party Monitoring of discharge from the King America Finishing Wastewater treatment plant

Collaborative Efforts to Implement On Line Analyzer Technology for Regulatory Total Residual Chlorine Monitoring

Attachment 1A Athol Corp. - CAM Plan

ECMPS Reporting Instructions Quality Assurance and Certification

GUIDELINES FOR PREPARATION OF CAPACITY ANALYSIS REPORTS

Ambient Air Quality and noise Measurements Report Gas pipeline network at Farshout- Naqada, Waqf, and Qeft - Qena governorate

CO-LOCATION FIELD STUDY Full Report. Pamplona (SPAIN) August November 2017 (4 Months) Season: Summer-Autumn

General Accreditation Criteria Equipment assurance, in-house calibration and equipment verification

Air Monitoring Directive Chapter 8: Ambient Audit

PRODUCT CONFORMITY CERTIFICATE

TNP Regulatory Guidance

ECMPS Reporting Instructions Quality Assurance and Certification

: Rodger Jeffery (Principal Author); Hardy Engineering Team; Hardy Tech Support Team

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT DRAFT STAFF REPORT

Method No.: 8.06/2.0/M Effective Date: January 4, 2012 Location: ###

State of New Hampshire Department of Environmental Services Air Resources Division. Temporary Permit

CISWI and solid-waste-identification rules

ENVIRONMENTAL MONITORING PROGRAMME

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR

MONITORING PROTOCOL IN SUPPORT OF THE CANADA-WIDE STANDARDS FOR MERCURY EMISSIONS FROM COAL-FIRED ELECTRIC POWER GENERATION PLANTS

Citations from CRF as required in WV DEP's 45CSR24

Protocol for intercomparison exercise, final version December 2008 AQUILA N 37

Monitoring Report. Sasol Nitrous Oxide Abatement Project South Africa. UNFCCC Ref Nº Monitoring period From: 7 March, 2007 To: 24 May, 2007

PRODUCT CONFORMITY CERTIFICATE

BetaGuard PM Measuring Particulate Continuously

SHASTA COUNTY DEPARTMENT OF RESOURCE MANAGEMENT AIR QUALITY MANAGEMENT DISTRICT

Transcription:

Continuous Emission Monitoring System (CEMS) Sanjeev K Kanchan

CEMS- What & Why? Strong pollution control regime is must Unlike US, EU, developing countries suffers from weak/missingpollution norms, standardised monitoring, market, transparency India inadequate existing regime 1. Manual monitoring low frequency, prone to manipulation 2. Reported data doesn t match actual emission 3. If online monitors no check on calibration, limited reporting 4. Real time data not accessible to regulator for verification 5. Poortransparency transparency no public scrutiny 6. Limited inspection fails to ensure adequate pollution control practices

CEMS- What & Why? GRP experience Even if pollution norms are tightened with time, pollution keeps growing; False compliance; poor monitoring & reporting 55% TPPs had very high emission 10% TPPs with PM norms of 50 75 mg/nm 3 visible emissions SO 2 no control, reported <13mg/Nm 3. Global best ~25mg/Nm 3 NOx reported <0.1mg/Nm 3. Global best ~80mg/Nm 3 CEMS A solution An important tool Ensures data accuracy, higher monitoring frequency, minimalmanual intervention, firm regulatory monitoring, better transparency.

CEMS- PM

CEMS- SO2, NOx

CEMS- Effluent

CEMS- framework

USEPA Experience 1. In mid 1970's Federal CEMS for tracking performance of APC device under EPA s NSPS (New Source Performance Standards). 2. Under ARP (Title IV of the 1990 Clean Air Act), stringent performance requirements for CEMS Mandatory real time monitoring SO 2, NOx, and CO 2 If 2 or more CEMS in same stack/duct primary + back up May choose alternative monitoring system demonstrate alternative having same/better precision, reliability, accessibility, and timelines Selection of device & conformance with the performance specifications

USEPA Experience Certification : Once installed, initial certification within 30 days performance tests Report of initial certification within 60 days Apply for certification Administrator s approval/disapproval within 120 days; otherwise deemed certified On disapproval monitored data invalid certification retest Re certification : series of tests required Any replacement/modification/change in a certified device, flue gas handling, operations that may affect device s performance After modification/change, a probationary calibration error test During re certification data conditionally valid In case of failure data to be flagged missing get substituted

USEPA Experience Quality Assurance (QA) Testing: Regular, verifies accurate operation of equipment. E.g. for COMS zero, upscale calibration drift test etc. Data monitoring & collection cycle: CEMS minimum one cycle in 15 mins mins. 4 cycles estimate hourly avg. COMS every 10 sec data (sampling & analysis ) to average for every 6 mins cycle 10 cycles estimate hourly avg. (state may permit differently) Plant t to report the dt data hourly, dil daily, quarterly, and annually No cycle time (pollutant conc. monitors like O2, moisture etc.) exceeds 15 mins

USEPA Experience Compliance check: Check for PM emission compliance (for LCP) o Min. total time of observations 3 hours (30 six minute averages) o Not to exceed 20 % opacity except one 6 minute period/hr (max 27 %) Check for SO 2, NOx emission compliance (LCP) o 30 days rolling avg. basis Special condition o Plants construction/modification/reconstruction before May 4, 2011, norms do not apply during startup, shutdown, or malfunction o Applicable for those commenced after May 3, 2011 Relative accuracy test audits at any time. If fails device is considered out of control till the next successful audit test

USEPA Experience Monitoring data availability and Substitution of invalid data: Need to monitor % valid data availability/ year To maintain record of hourly avg. data for at least 3 years Certification, qlty control and assurance data recorded daily Invalid data to be substituted If valid, quality assured data not provided by a certified equipment, missing/invalid data is substituted by estimating from valid data recorded in last 3 years. Plants are required to submit Excess Emission Reports (EERs): include excess emissions and excess monitoring system down time, quarterly and sometimes monthly

Real-time effluents monitoring in USA Regulated by the National PollutantDischarge EliminationSystem (NPDES) established under the Federal Water Pollution Control Act Amendments of 1972. Both sequential and continuous monitoring allowed If higher monitoring frequency needed continuous samplers To establish continuous monitoring requirement env. significance of effluent parameters and cost implicationsare are assessed Limited parameters flow, TOC, temp., ph, conductivity, residual Cl, F, DO etc. Monitoring and reporting requirements are decided on case to case basis. Requirements may be reduced dbased excellent historical i performance Effluent Limits: by comparing BAT based effluent with water quality based effluent limits Monitoring Frequency: based on flow, pollutant type & concentration, treatment capacity & method, compliance history, permittee s capabilities, discharge location & frequency etc.

EU Experience Called as Automated Measuring System (AMS). European Standard (EN 14181) specifies 3 quality assurance levels and an annual surveillance test. Quality assurance level 1 (QAL1): Suitability of CEMS Before installation MCERTS certification for compliance with QAL1 Plant to do required tests zero span, linearity, leak detection etc. Quality assurance level 2 (QAL2): Calibration and Validation Post installation Verifies through inspection and set of functional tests Frequency o After installation, o Every 5 year for LCP/ 3 year for waste incinerators, o Significant change in plant operations, significant upgrade or change in device

System for uncertainty of CEMS EU Experience Table. Allowable uncertainties of CEMS for coal based LCP in EU Limits mg/m 3 Certification range, mg/m 3 Allowable uncertainty, % NOx 200 600 500 1500 20% 40 120 SO 2 200 850 500 2125 20% 40 170 PM (LCP) 30 50 75 125 30% 9 15 Allowable uncertainty, mg/m 3 Quality assurance level 3 (QAL3): During operation Detects drift and changes in precision zero and span readings Frequency weekly or shorter based on method (CUSUM; cumulative sum control, Stewart chart etc. ) Mandatory recording of all activities CEMS details & changes, manufacturers service visit, call out records, routine maintenance, corrective actions, zero and span drift plots and tabulation etc.

EU Experience Annual surveillance test (AST): Check that calibration function carried under QAL2 is valid Same functional tests as in QAL2, but less repetitions If the AST shows calibration invalid, then a full QAL2 is required Sampling frequency and duration: decided in management plan Commonly duration is 30 minutes, but may vary depending on the pollutant (e.g. for PCDD/F duration is 6 hours), expected conc., dt detection ti limit it and emission i profile of the process. Compliance: Vary among EU members, sector wise. For LCP : 95 % of all hourly avg (yearly) not to exceed 200 % of the norm Daily average not to exceed 110 % of the norm Monthly average not to exceed the norm For <50 MW, daily average not to exceed 150 % of the norm

Status in India No established regulatory framework for CEMS till now A pilot project for continuous PM monitoring and ETS initiated in Gujarat, Maharashtra and Tamil Nadu 22.11.2013 A direction by CPCB for installation of CEMS for air pollution monitoring and effluent quality monitoring from stationary sources. 05.02.2014 CPCB guidelines for online continuous monitoring systems for effluents. 07.11.2014

PM - CEMS in India CEMS guidelines for PM with ihspecial ilreference to pilot scale ETS Selection of suitable certified deviceo Mass flow or, concentration based o =<10mg/Nm 3 detection level, <1 % drift, < 5% measurement deviation o Flow metre with 1 m/s min detection, < 1% zero and span drift, < 2% measurement deviation o Hardware & software to record every 1 min data, 90% or higher data availability Certification from recognized agency USEPA PSII, MCERT, TUV etc. Initial calibration required before installation Device performance test after calibration Periodical quality control test CEMS audit at least every 12 months

PM- CEMS in India Standard operating procedure Device installation, registration, configuration industry to do Calibration Accredited lab (by NABL/MoEF/CPCB/SPCB) o Sampling under various operational conditions (load, efficiency of APC device etc.) o 95% data availability o Calibration at least every 6 months after initial calibration Post calibration performance test to measure avg. deviation between raw readings and iso kinetic readings and fix calibration equation CEMS audit and CEMS audit performance test by accredited labs at fixed calibration equation, sample points and at different load Recalibrationoif operating out of range 10% or more in a week for 5 weeks or more/ 40% or more in a week for 01 week or more (45 mins moving average), odevice hardware changed, changes in fuel/process, major change in APC device oevery 06 months, ofailure of CEMS audit

Real-time effluent monitoring in India Selection of equipment by industries Device calibration (weekly for most parameters) by manufacturer At least 85% data availability 1 min. data average every 30 minutes transfer Allows 10% exceedance of norm; Regular exceedance action Relative difference between online and laboratory lb measurement ±10% allowed for BOD, COD, TSS and ±0.2 for ph ZLD plants to install camera with night vision and flow meter Plants ZLD by utilizing treated water in irrigation to install continuous monitor at the outlet of ETP Bank guarantee (of 25 % of device cost) from manufacturer to ensure optimal performance of device, and 85% data availability. Cost of effluent monitoring 1.5 lakh to 60.5 lakh across sectors