arc lamp is substituted. Before

Similar documents
Anatomy of a flow cytometer

Introduction to Flow Cytometry:

Introduction to Flow Cytometry: A Learning Guide

Definitions. What functions does a flow cytometer be able to do? The build of the Flow cytometry and sorting. Flow cytometry

11/19/2013. Janine Zankl FACS Core Facility 13. November Cellular Parameters. Cellular Parameters. Monocytes. Granulocytes.

Principles of flow cytometry: overview of flow cytometry and its uses for cell analysis and sorting. Shoreline Community College BIOL 288

Each question may have MULTIPLE correct answers. Select all that are correct.

ANAT 3231 Cell Biology Lab12 Stem Cell Analysis

Flow Cytometry - The Essentials

Basic Principles in Flow Cytometry. Flow Cytometry

INTRODUCTION TO FLOW CYTOMETRY

seminar

BASICS OF FLOW CYTOMETRY

ALL INFECTOLOGY. and now. Gucker, 1947 Wallace Coulter Coulter Orifice, Kamentsky, 1965 Mack Fulwyler sorter BLOOD:

ALL INFECTOLOGY COMMERCIALLY AVAILABLE DEVICES. and now BLOOD:

Immunophenotyping of Peripheral Blood and Bone Marrow Cells by Flow Cytometry *Akanni EO and # Palini A.

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

J. Philip McCoy, Jr., Ph.D., H.C.L.D. J. Philip McCoy, Jr., PhD

determine optimum instrument settings for their own instruments and establish their own daily values.

Flow Cytometry. Marta Argenti, PhD student. Department of Biomedical Sciences Padua

Designing and Implementing a High-Level Multicolor Flow Cytometry Assay. Brent Wood MD PhD Department of Laboratory Medicine University of Washington

Flow Cytometry. Flow Cytometry Basics Guide

The Basics of Flow Cytometry

Flowcytometry Dirk Pacholsky

Spherotech, Inc. 1. SPHERO TM Technical Note STN-8 Rev C

High-throughput automation with the Attune NxT Autosampler: consistent results across all wells and across plates

A previous ICCS Module entitled Instrument optimization - Adjusting PMT voltages and compensation 1 should be read as a prerequisite to this module.

Flow Cytometry in the Diagnosis of Hematopoietic Neoplasia. Brent Wood MD, PhD Professor, Laboratory Medicine University of Washington, Seattle

Introduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Application Specialist BDBiosciences

Navios EX FLOW CYTOMETER POWERFUL, DEPENDABLE CLINICAL FLOW CYTOMETRY

Flow Cytometry For New PhDs

Incorporating New, Bright Fluorochromes into Multicolor Panel Design

Introduction to. BD FACSAria TM Cell Sorter. Flow = Fluid Cyto = Cell Metry = Measurement

NovoCyte Flow Cytometer

Minimum Information about a Flow Cytometry Experiment (MIFlowCyt) Annotation

INTRODUCTION TO FLOW CYTOMETRY

Application Note. Assay Portability on the BD FACSVerse System. Summary. Maria Jaimes, Yibing Wang, Catherine McIntyre, and Dev Mittar

Flow Cytometry. Principles and Applications. Edited by. Marion G. Macey, PhD

Attune NxT Acoustic Focusing Cytometer The next generation in acoustic cytometry

Theory and Applications for Cell Sorter

Navios EX FLOW CYTOMETER POWERFUL, DEPENDABLE FLOW CYTOMETRY

Flow Cytometry. Flow Cytometry Basics Guide

Attune TM Acoustic Focusing Cytometer Training. Manik Punj Attune Training

Best practices in panel design to optimize the isolation of cells of interest

PowERFUL. INTUITIvE. customizable. ThE NEw STAR of. BENchToP FLow cytometry

DEPArray Technology. Sorting and Recovery of Rare Cells

Cell analysis and bioimaging technology illustrated

Boundary-breaking acoustic focusing cytometry

Titration of Fluorochrome-Conjugated Antibodies for Labeling Cell Surface Markers on Live Cells

Application Note. Yeast Analysis with a life - dead staining kit (Yeast control - viability)

Identification of red and white blood cells from whole blood samples using the Agilent 2100 bioanalyzer. Application Note

Flow cytometry has become an increasingly important

The Cell Cycle, DNA Replication, and Mitosis

Automation In Life Sciences and Diagnostics Applications

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

TECHNICAL BULLETIN. QUANTUM FLUORESCENCE KITS FOR MESF UNITS OF FITC Product Numbers QMF-2 AND QMF-10 Storage Temperature 2-8 C.

Compensation: Fundamental Principles

ACTG Laboratory Technologist Committee Revised Version 2.0 ACTG Lab Man CD38 Quantitation 07 May 2004

Micro-fluidic Chip for Flow Cytometry Jeff Wang

Beyond Colorful Science. A Practical Approach to Setting Up Multicolor Panels

What you need to know before designing a panel

Detecting human circulating endothelial cells using the Attune Acoustic Focusing Cytometer

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

TECHNICAL BULLETIN. QUANTUM FLUORESCENCE KITS FOR MESF UNITS OF FITC Product Numbers QMF-2 AND QMF-10 Storage Temperature 2-8 C.

FLOW CYTOMETRY. CyAn ADP. Analyzer

BIMM18 Dec 20 th - Flow cytometry in clinical diagnostics

Formalization of the MESF Unit of Fluorescence Intensity

Lab 2. Isolation of mononuclear cells from peripheral blood and separation into subpopulations.

Phagocytosis Assay Kit (IgG PE)

Review of techniques in imaging and cytometry. Peter Meeus Onze Lieve Vrouw Ziekenhuis, Aalst 7 may 2009, SCK/CEN Mol

Navios Now Because Every Event Matters

CRC Flow Cytometry Core Facility Knut och Alice Wallenbergs Stiftelse

Review of techniques in flow cytometry. Peter Meeus Onze-Lieve-Vrouwziekenhuis, Aalst 5 may 2011, SCK/CEN Mol

Antigen-antibody reactions with labeled reagents

CLEARLLAB LS LYMPHOID SCREEN REAGENT

Qdot nanocrystal. wide range of biological investigations, Qdot nanocrystals are powerful complements

PERFECT-COUNT MICROSPHERES

Selecting Fluorochrome Conjugates for Maximum Sensitivity

BD FACSMelody. Cell Sorter. The simple solution for consistent, quality results

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

Ruud Hulspas, Mike Keeney, Ben Hedley and Andrea Illingworth

Immunological Techniques in Research and Clinical Medicine. Philip L. Cohen, M.D. Chief of Rheumatology, LKSOM 10 March 2016

The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee

Institute of Science & Technology in Medicine Control of Substance Hazardous to Health COSHH assessment

18/08/2011. Principles of Flow Cytometry (Practised in a Clinical Laboratory) Cytometer Components. Noel Williams Immunobiology Division of Immunology

Live and Dead Cell Assay

Principles of Multicolor Panel Design BD. BD, the BD Logo and all other trademarks are property of Becton, Dickinson and Company.

Application Information Bulletin: DuraClone IM Tubes Compensation setup for high content DuraClone reagents

BD FACSCanto II. A proven research platform for maximum reliability and the highest quality results

Using Fluorescence Spillover to Advantage

Analysis of repetitive DNA in chromosomes by flow cytometry

TECHNICAL BULLETIN. QUANTUM SIMPLY CELLULAR KIT Product Numbers QSC-20 AND QSC-100 Storage Temperature 2-8 C. Do Not Freeze

a Beckman Coulter Life Sciences: White Paper

Single Tube, Six-Color Flow Cytometric Analysis Is a Sensitive and Cost-Effective Technique for Assaying Clonal Plasma Cells

BIO 315 Lab Exam I. Section #: Name:

BD LSRFortessa. Performance without peer, choice without compromise

Fluorescence Microscopy. Terms and concepts to know: 10/11/2011. Visible spectrum (of light) and energy

ab CFSE Fluorescent Cell Labeling Kit

Flow Cytometric Devices Draft Guidance for Industry and Food and Drug Administration Staff DRAFT GUIDANCE

Transcription:

CE update [cytology hematology generalist] The Principles of Flow Cytometry Antony C. Bakke, PhD From the Department of Pathology, Oregon Health Sciences University, Portland, OR On completion of this article, the reader should be familiar with the basic components of a flow cytometer, the principles of its operation, specimen analysis, data presentation, and quality control. Cytology exam 0102 questions and the corresponding answer form are located after the Your Lab Focus section, p 213. The uses of flow cytometry The basic components of flow cytometers Flow cytometry specimen analysis Flow cytometry quality control Flow cytometry is defined as the simultaneous measurement of multiple physical characteristics of a single cell as the cell flows in suspension through a measuring device. It is a subset of the field of cytometry based on the use of specialized instruments. Flow Cytometry Compared With Other Techniques The original flow cytometer was the Coulter counter (Beckman Coulter M) invented by Wallace Coulter in the 1950s. All current automated, non slide-based hematology instruments are flow cytometers. These instruments require cells in suspension and the ability to move cells through the instrument. Blood is the ideal tissue because the cells are already in suspension and can be easily analyzed. The Coulter principle uses the resistance of a cell in an electrical current as it passes through an orifice to determine numbers of particles and the size of the particle. Flow cytometry has specifically come to denote the use of fluorescence measurement, usually with a laser light source. In laser flow cytometers, light scatter is used to measure the intrinsic size and granularity of the cell. In addition, fluorescence can be used to measure extrinsic features such as specific protein expression and nucleic acid content using added reagents, such as fluorescent stains and antibodies. Flow cytometers may be compared with fluorescence microscopes. With a microscope, the light source is a lamp, the objective lens focuses the image, and the eye is the detector. With a flow cytometer, the light source is a laser, an objective lens focuses the light, and the detector is a photomultiplier tube [F1]. With a fluorescence microscope, the observer views cells and recognizes their different sizes. If a fluorescent probe is bound to the cell, a specific-colored fluorescence is emitted. Flow cytometry does not provide a focused image as does a microscope, but it does detect light and transform the signal into statistical data that can be presented in various graphic formats. Components of a Flow Cytometer Optics A laser beam is used in most flow cytometers as the light source to excite a fluorescent tag (eg, a fluorescent antibody) bound to the cells in the specimen. An argon laser, which produces blue light, is the most commonly used, although some instruments add a red helium-neon laser, and occasionally a mercury arc lamp is substituted. Before 207

your lab focus 208 striking the cells, the light from either source passes through focusing and shaping optics to form an elliptical beam with a broad, maximal intensity in the center. The beam then passes through the center of a flow chamber, which is a quartz cuvette with an approximately 200-µm inner diameter. The specimen is also injected through the middle of this flow chamber, where the laser beam strikes the cell [F2]. When the laser strikes the cell, light is diffracted around the edges of the cell, producing a diffraction pattern along the path of the laser beam. This scattered light is approximately equivalent to the cell circumference and is the same wavelength as the exciting laser light (usually blue). Termed forward scatter (FSc) or forward angle light scatter (FALS), it is collected along the same axis as the laser beam. Because this is a very strong signal, a simple photodiode can convert the forward-scattered light into an electrical pulse. However, the direct laser beam could enter this photodiode, giving an overwhelming signal. A physical barrier eliminates the direct laser beam by blocking about a 2-degree angle of light along the path of the laser, allowing only the light diffracted at greater angles to pass. In addition to the forward-scattered light, blue laser light is also reflected off the cell and off internal structures in the cell. This is termed side scatter (SSc), right-angle light scatter (RALS), or 90- degree light scatter (90LS) because it is detected by a collection objective set at 90 degrees to the incident laser light. It is a measure of granularity of the cell. Granulocytes have a much larger sidescattered light signal than do lymphocytes ([F1]; see also [F5]). After being focused by the objective lenses, the blue light is reflected by a dichroic mirror. These mirrors direct specific wavelengths of light into the correct detector. The detector is a photomultiplier tube, which converts the light signal into an electrical signal. Fluorescent probes can also be added to the cell for detecting specific molecules in the cell. These probes are typically antibodies to cellular antigens with a covalently attached fluorochrome. The fluorochrome, excited by the laser 1. Labor intensive; rates of 100 cells/min 2. Total number analyzed usually low, 1000 or fewer 3. Morphology and intracellular probe distribution; tissue sections 4. Quantilation of fluorescence limited; eye sensitivity approximately equal to 10 change light, will fluoresce at a longer wavelength. Fluorescein gives a green fluorescence, phycoerythrin (an algal protein) gives orange, and peridinin chlorophyll protein or phycoerythrin coupled to cyanin 5 produces red fluorescence. Some flow cytometers have a second laser that can excite other fluorochromes. Like the side-scattered blue 1. Rapid analysis; rates of 50-4,000 cells/s 2. Total number analyzed can be very high; 5K- 100K+ (for rare events and accurate statistics) 3. Lack of information about intracellular probe distribution 4. Excellent quantitation of fluorescence per cell; range of 10 5 change 5. Single cell suspension critical 6. Correlated multiparameter analysis [F1] Light microscopy compared with flow cytometry for the detection of cells and cellular probes. Reproduced with permission from Becton-Dickinson M. [F2] Light scatter measurements in a flow cytometer. The blue laser beam intersects the cell in the middle of the flow chamber. Forward scatter or forward angle light scatter (FALS) is measured along the axis of the laser beam. Blue laser light reflected off the cell and off internal structures in the cell is termed side scatter or 90-degree light scatter (90LS). Reproduced and altered with permission from Purdue University Cytometry Laboratories. The copyright for the original figure cannot be sold or transferred. light, all of these fluorescent signals pass through the objective set at 90 degrees to the incident laser light. Additional dichroic mirrors reflect specific wavelengths of light, allowing separation of the signals from each fluorochrome with minimal overlap. In front of each photomultiplier, a final bandpass filter precisely defines the wavelength of light entering that detector.

your lab focus [F3] Flow cell showing hydrodynamic focusing of the specimen by the surrounding sheath fluid. Reproduced with permission from Becton- Dickinson M. Fluidics The flow cytometer has 2 sources of fluid passing through it: a sheath fluid that is usually a buffered saline, and the specimen containing the cells to be analyzed. The specimen forms a core, which is injected into the middle of the sheath fluid, and both pass through the flow chamber [F3]. The outer sheath fluid causes hydrodynamic focusing, which compresses the specimen core into a small area. Cells are forced to pass singly through the focal point of the laser, which is crucial for collecting accurate information about each cell in the specimen. Electronics The photodiode detectors or photomultipler tubes first collect the light signal from the cells. In both cases, the photons produce a pulse of electrical current. Photomultiplier tubes have a voltage applied across a series of plates. This increases their sensitivity so that fewer photons are required to produce an electrical current. The initial small current requires amplification. The amplified current ranges from 0 to 10 V depending on the strength of the signal. The voltage signal is an analog signal and cannot be recognized by the computer. It is converted by an analog-todigital converter into a digital signal, called a channel, which can range from 0 to 1,023 channels. The channel is a counter, and all signals of a specific voltage are counted in a channel corresponding to the strength of the signal. The amplification of the initial signal can be either linear or logarithmic. Linear amplification provides a direct visual relationship and is useful for scatter signals and fluorescent measurements of DNA. Linear amplification allows a dynamic range of approximately 200- to 1,000-fold. Logarithmic amplification is used for most other biologic signals, including immunofluorescence, owing to the extreme dynamic range of these signals. Logarithmic amplification gives a dynamic range of 2,000- to 10,000-fold. The fluorescent signals have been discussed above. Although these signals appear mainly as a single color under the microscope, actually the emission from any fluorochrome is broad. Although fluorescein isothiocyanate (FITC) appears apple-green, it also has lower-level emissions in the orange area of the spectrum. Hence, any green FITC-stained cell will also generate a signal in the orange channel, making the cell appear to be labeled by 2 fluorochromes. To allow multicolor fluorescence, this apparent overlap must be eliminated. This is done by fluorescence compensation. A percentage of any bright signal, such as FITC, is subtracted from any other associated signal. The instrument is set up at the beginning of a run with pure signals of each fluorochrome, and any associated fluorescence at the other wavelengths is compensated [F4]. a b c 209 [F4] Electronic compensation corrects spectral emission overlaps. Two-parameter contour plots of fluorescein vs phycoerythrin fluorescence. a, No compensation produces results with many cells apparently expressing both fluorochromes, although these are mutually exclusive stains (CD4 and CD8). b, Overcompensation leaves many cells on the axes and may decrease dual expression when present. c, Correct compensation produces results in which mutually exclusive stains appear to be pure green or orange and few dual-labeling cells are present. FL1-H, x-axis, green; FL2-H, y-axis, orange. Specimen Analysis Specimen Preparation Specimens are often whole blood but may be other tissues. For analysis, the specimen must contain greater than 95% single cells for accurate interpretation of the data. Whole blood is a single cell suspension, but tissues must be disaggregated into single cells before analylaboratorymedicine> april 2001> number 4> volume 32

your lab focus a b c Ungated total particles M1 0% 24% Gated lymphocytes 11% 65% 10 0 10 1 10 2 10 3 FL1-H [F5] Data can be displayed on several plots and electronically gated to analyze pure populations. a, Dot plot of lysed whole blood showing forward scatter vs side scatter with a gate surrounding lymphocytes. b, Overlaid histograms of fluorescein fluorescence showing the difference with total and gated population analysis. The positive cells within the markers are 1% of the total particles, including debris, but 89% of the gated lymphocytes. c, Dot plot of fluorescein vs phycoerythrin fluorescence showing quadrant statistics. FL1-H, x-axis, green, fluorescein; FL2-H, y-axis, orange, phycoerythrin. 210 sis. Often antibodies are used to stain cells and select subpopulations or evaluate protein expression. In most cases, these antibodies are commercial products with robust staining properties. However, the staining patterns should be confirmed in the laboratory on each new lot of antibody using appropriate control materials. Unknown antibodies must be carefully evaluated for specificity and efficacy of staining. This is best done under a microscope initially because nonspecific staining or unusual patterns can be better distinguished with a microscope than with a flow cytometer. Once approximate staining characteristics are determined, the procedure can be fine-tuned for the flow cytometer. Data Processing The initial light signal is first converted by the detectors into an electric current, which is amplified and measured as an analog quantity, such as 5 V of a maximum of 10 V. Because this signal is analog, it must be converted into a digital signal for computer processing. The signal then becomes an event with a specific digital channel value such 512 on a 1,024-channel scale. The digital data can be displayed as 1-parameter histograms [F5b] or as 2-parameter plots [F4, F5a, F5c]. The information on a 1-parameter histogram is described either as the percentage of cells within a set of markers or as the mean fluorescence intensity of a population. For logarithmically amplified signals, the geometric mean fluorescence is used, since it is less influenced by the extreme ends of the distribution. A 2- parameter plot is usually divided into 4 quadrants, each containing a percentage of the total population [F5c]. This division is used to distinguish between fluorescent and nonfluorescent cells. It also defines expression and nonexpression of a cell molecule marked by a fluorescent antibody or other fluorochrome. Because the specimen that is analyzed may be complex with several populations plus debris, such as lysed whole blood, analysis of the total specimen would give variable and confusing results. Therefore, it is often necessary to analyze a single population, such as lymphocytes. Electronic gating allows separation of the total population into parts, which can be individually analyzed [F5a]. Quality Control There are several kinds of quality controls. First the flow cytometer itself must be evaluated for proper function. This is usually accomplished with standardized fluorescent beads. These give very precise, reproducible patterns, which quickly assess instrument function. In addition, the beads are fairly stable and can be used daily with little change in values. The bead values for instrument settings and signal intensity are used to generate Levy-Jennings plots and determine instrument errors. A second quality control material is used to set up the appropriate instrument settings for the type of staining used. These can be beads or antibody-stained cells. One of the primary functions of this second control is to establish the compensation settings for the instrument; therefore, either beads or cells should mimic the staining that will be used on actual specimens. The third level of quality control is a control substance that mimics actual specimens. These controls are available commercially and usually consist of stabilized blood, sometimes with added tissue-culture cells that mimic a specific cancer cell. These controls can be used to assess the sensitivity of the instrument. They will have published ranges for many of the antibodies used in the laboratory. Because they usually contain normal, stabilized blood cells, some proteins characteristic of specific cancer cells will not be present. For this reason, some tissue-culture cells may be included because they express specific proteins that can be used to evaluate other antibodies.

Conclusion Flow cytometry is used in the clinical laboratory for a variety of analyses including diagnostic immunophenotyping of lymphomas, leukemias, and congenital immunodeficiencies; detection of minimal residual disease in leukemias; monitoring CD4+ T-lymphocyte counts in HIV patients; DNA content analysis for prognosis of malignancies; screening of hematologic disorders such as paroxysmal nocturnal hemoglobinuria and idiopathic thrombocytopenic purpura; evaluation of peripheral stem cell products for transplantation; monitoring monoclonal antibody therapy; and determination of the extent of maternal/fetal bleeding by detection of hemoglobin F. Flow cytometry remains a laborintensive area of laboratory medicine requiring extensive training. Learning the fundamental principles of flow cytometry enhances both patient care and work satisfaction. In addition, these principles apply to other areas using cytometry techniques, such as hematology. For more details and theoretical discussion, the reader is referred to several books 1-4 and Internet sites. 5,6 1. Givan AL. Flow Cytometry: First Principles. New York, NY: John Wiley & Sons; 1992. 2. Bauer KD, Duque RE, Shankey TV, eds. Clinical Flow Cytometry: Principles and Application. Baltimore, MD: Williams and Wilkins, 1993. 3. Owens MA, Loken MR. Flow Cytometry Principles for Clinical Laboratory Practice, Quality Assurance for Quantitative Immunophenotyping. New York, NY: Wiley-Liss; 1995. 4. Melamed MR, Lindmo T, Mendelsohn ML. Flow Cytometry and Sorting. 2nd ed. New York, NY: Wiley-Liss; 1990. 5. Purdue University Cytometry Laboratories. http://flowcyt.cyto.purdue.edu/. Accessed January 8, 2001. 6. Hematopathologic phenotypes made mockingly simple. Available at: http://www.neosoft.com/ ~uthman/cdphobia/cdphobia.html. Accessed January 8, 2001. PostScript Picture 211