Your Research, Revolutionized

Similar documents
Your Research, Revolutionized

Navios EX FLOW CYTOMETER POWERFUL, DEPENDABLE CLINICAL FLOW CYTOMETRY

Navios EX FLOW CYTOMETER POWERFUL, DEPENDABLE FLOW CYTOMETRY

a Beckman Coulter Life Sciences: White Paper

NovoCyte Flow Cytometer

Each question may have MULTIPLE correct answers. Select all that are correct.

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

FLOW CYTOMETRY. CyAn ADP. Analyzer

DURACLONE IM ACCELERATE YOUR PACE IN IMMUNE SYSTEM RESEARCH. For Reseach Use Only - Not for use in Diagnostic procedures

NovoCyte Quanteon F. Flow Cytometer. When Exceptional Performance Meets Simplicity

PowERFUL. INTUITIvE. customizable. ThE NEw STAR of. BENchToP FLow cytometry

Flow cytometry within reach.

CyFlow Cube series Appealing from every angle

a Beckman Coulter Life Sciences: White Paper

Principles of flow cytometry: overview of flow cytometry and its uses for cell analysis and sorting. Shoreline Community College BIOL 288

Boundary-breaking acoustic focusing cytometry

Application Information Bulletin: DuraClone IM Tubes Compensation setup for high content DuraClone reagents

a Beckman Coulter Life Sciences: White Paper

A previous ICCS Module entitled Instrument optimization - Adjusting PMT voltages and compensation 1 should be read as a prerequisite to this module.

BD FACSCanto II. A proven research platform for maximum reliability and the highest quality results

Incorporating New, Bright Fluorochromes into Multicolor Panel Design

Principles of Multicolor Panel Design BD. BD, the BD Logo and all other trademarks are property of Becton, Dickinson and Company.

CLEARLLAB LS LYMPHOID SCREEN REAGENT

Flexible, Intuitive and Affordable

Anatomy of a flow cytometer

What you need to know before designing a panel

Cancer inflammation research applications and products

BD FACSMelody. Cell Sorter. The simple solution for consistent, quality results

High-throughput automation with the Attune NxT Autosampler: consistent results across all wells and across plates

Flow Cytometry - The Essentials

AMREP FLOW CYTOMETRY CORE FACILITY. Flow Cytometry Data Analysis Workshop Friday 24 th October

determine optimum instrument settings for their own instruments and establish their own daily values.

Expanding Multicolor Options in Flow Cytometry with Novel Brilliant Violet TM Fluorophores. Carsten Wiethe Scientific Application Manager BioLegend

Application Note. Assay Portability on the BD FACSVerse System. Summary. Maria Jaimes, Yibing Wang, Catherine McIntyre, and Dev Mittar

Beadless Absolute Counting

Using Fluorescence Spillover to Advantage

BD Accuri C6. Flow cytometry within reach.

Selecting Reagents for Multicolor Flow Cytometry

Best practices in panel design to optimize the isolation of cells of interest

Designing and Implementing a High-Level Multicolor Flow Cytometry Assay. Brent Wood MD PhD Department of Laboratory Medicine University of Washington

Beyond Colorful Science. A Practical Approach to Setting Up Multicolor Panels

Spherotech, Inc. 1. SPHERO TM Technical Note STN-8 Rev C

Understanding Flow Cytometry

Review of techniques in imaging and cytometry. Peter Meeus Onze Lieve Vrouw Ziekenhuis, Aalst 7 may 2009, SCK/CEN Mol

Application Note. Yeast Analysis with a life - dead staining kit (Yeast control - viability)

Navios Now Because Every Event Matters

GUAVA EASYCYTE SYSTEMS

The Worlds First Smart Flow Cytometer

Guava easycyte Systems Expanding the potential of flow cytometry

Guava EasyCyte Systems Expanding the potential of flow cytometry

Novel Developments in Cytometry. Martin Adelmann Marketing Manager Cellular Analysis & Life Science Beckman Coulter EMEAI

CyFlow Cube 6. Immunology Microbiology Industrial Applications Agrosciences Aquaculture. Flow Cytometry: Simply elegant. Elegantly simple.

BD LSRFortessa. Performance without peer, choice without compromise

BASICS OF FLOW CYTOMETRY

CyFlow Space Your flexible flow cytometer

Visualization of digital data Interpretation of the visual

CyFlow Space Your flexible flow cytometer

Flowcytometry Dirk Pacholsky

11/19/2013. Janine Zankl FACS Core Facility 13. November Cellular Parameters. Cellular Parameters. Monocytes. Granulocytes.

Review of techniques in flow cytometry. Peter Meeus Onze-Lieve-Vrouwziekenhuis, Aalst 5 may 2011, SCK/CEN Mol

BD Multicolor CompBeads

Attune NxT Acoustic Focusing Cytometer The next generation in acoustic cytometry

CyFlow Space. Your Flexible Flow Cytometer.

SA3800 Spectral Analyzer

Compensation: Fundamental Principles

Introduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Application Specialist BDBiosciences

Designing and executing a successful flow cytometry experiment

Attune TM Acoustic Focusing Cytometer Training. Manik Punj Attune Training

Challenges for Flow Cytometry in Regulated Bioanalysis

BD Accuri C6 Plus FLOW CYTOMETER

Lower spectral overlap. Optimized stain index. Innovative antibodies. Superior multicolor flow cytometry. Violet Laser Reagents: The efluor Solution

2. SUMMARY AND EXPLANATION

ANAT 3231 Cell Biology Lab12 Stem Cell Analysis

Flow Cytometry Support Reagents

Kaluza Analysis Software SOPHISTICATED FLOW CYTOMETRY, SIMPLIFIED.

Muse Cell Analyzer. Experience simple, affordable flow cytometry.

Definitions. What functions does a flow cytometer be able to do? The build of the Flow cytometry and sorting. Flow cytometry

INTRODUCTION TO FLOW CYTOMETRY

Introduction to. BD FACSAria TM Cell Sorter. Flow = Fluid Cyto = Cell Metry = Measurement

seminar

SP6800 Spectral Analyzer

Calibración de equipos de citometría para empleo de paneles EuroFlow

Hey! Have you heard that ebioscience has launched PerCP-Cy5.5 conjugates?

BR-16994A BIOMEK 4000 LABORATORY AUTOMATION WORKSTATION INTUITIVE SOFTWARE. MAXIMUM VERSATILITY.

BR-9516B. SNP genotyping analysis for medium to ultra-high throughput. GENOMELAB TM SNPSTREAM GENOTYPING SERIES

BD LSR Cell Analyzer. Performance without peer, choice without compromise

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

Flow Cytometry Immune Activation SOP

flow cytometry reinvented

High-dimensional flow-cytometric analysis of human B-cell populations

Flow Cytometry. Cell Sorting 34 Instruments 34 Consumables 38

Flow Cytometry SOP: Monocytes from Frozen Cells

Institute of Science & Technology in Medicine Control of Substance Hazardous to Health COSHH assessment

AQUIOS CL LOAD & GO AND MAKE FLOW CYTOMETRY SIMPLICITY ITSELF

High Throughput Suspension Cell and Bead Analysis. Intellicyt ique Screener PLUS

Orflo Application Brief 3 /2017 GFP Transfection Efficiency Monitoring with Orflo s Moxi GO Next Generation Flow Cytometer. Introduction/Background

Introduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Assistant Product Manager BDBiosciences

Application Information Bulletin: CytoFLEX Analyzer

Flow Cytometry SOP: 14 color flow for immune activation, senescence, and exhaustion

Welcome to the CORES Flow Cytometry Sorter Facility

Transcription:

Your Research, Revolutionized

Drive Your Research Forward Your research needs are evolving and with the CytoFLEX flow cytometer you ll see just how far your data can take you. CytoFLEX has the advanced detection technology you need to drive leading edge discoveries and position your lab at the forefront of cellular research. The unique design of CytoFLEX offers progressive application capabilities, from one to 3 lasers and from 4 to 13 colors, enabling you to get the most out of your multicolor analysis. CytoFLEX s compact size, low maintenance requirements, superior sensitivity, and resolution for robust performance throughout all configurations give it the edge over other cytometry systems. CytoFLEX allows you to expand easily as your research takes you forward. The patent-pending Wavelength Division Multiplexing (WDM) detection module uses solid-state, high efficiency, low-noise Fiber Array Photodiode Detectors (FAPD), giving you exceptional resolution for more precise data and better detection of rare events.

Resolve to get more from your data Breaking new ground, breaching the frontiers of cellular analysis, getting there first does that sound like what you want from your research? 8-peak Rainbow Beads Exceptional instrument sensitivity: baseline resolution of all peaks even in violet and far red channels detectors using SPHERO Rainbow 8-peak beads. CytoFLEX delivers the versatile performance and advanced sensitivity you need for the results you want.

Maintain Your Pace Of Discovery With its high sensitivity and ease of upgrading, CytoFLEX lets you perform research on your own terms, today and well into the future. Scale up sensitivity for single-laser applications: Viability Cell Proliferation Cell Cycle Analysis Apoptosis DNA Analysis Bacteria Analysis Yeast and Algae Analysis Absolute Cell Counts See what you ve been missing CytoFLEX s compact size, low maintenance requirements, superior sensitivity, and resolution for robust performance throughout all configurations give it the edge over other cytometry systems. CytoFLEX allows you to expand easily as your research takes you forward. The patent-pending optics design includes an innovative integrated optics flow cell. The revolutionary detection system presents optimal excitation and emission, minimizing light loss and maximizing sensitivity. Whether fully configured as a 13-color, 3-laser system, or as a 4-color, one-laser system, CytoFLEX s compact bench-top footprint affords cutting edge sensitivity similar to or better than market-leading cytometers four times its size. Gain confidence with accurate, reproducible results from alignment stability Expand fluorochrome choice with up to 13 band pass filters and distinguish 200nm particles with the 405nm violet side scatter parameter Realize robust data Propidium iodide stained Chicken Erythrocyte Nuclei demonstrating system linearity. Data courtesy of Ryan Duggan, University of Chicago. Acquire accurate data through innovation CytoFlex s advanced optical system minimizes light loss and maximizes data resolution, giving you ultra-high sensitivity for increased detection. 7 decades of tunable dynamic range <30 MESF FITC <10 MESF PE 200nm particle detection There s really no questioning [CytoFLEX] performance in terms of fluorescence detection. Ryan Duggan, University of Chicago

Ultimate flexibility for total control CytoFLEX gives you robust performance for all configurations, regardless of complexity, as well as easy upgradeability so you can maintain your pace of discovery over time. Power up your performance and expand your high complexity capacity up to 15 parameters for future-proof adaptive detection capabilities. With small footprint, the CytoFlex easily fits in standard biohazard hoods. Total FL 488nm 638nm 405nm Lasers Channels FL Channels FL Channels FL Channels 3 13 5 3 5 3 12 5 3 4 3 12 4 3 5 3 11 4 3 4 3 11 3 3 5 2 10 5 5 3 10 5 3 2 3 10 4 3 3 3 9 3 3 3 3 9 4 3 2 3 8 3 3 2 3 7 2 3 2 2 6 3 3 2 6 3 3 2 6 4 2 2 5 3 2 2 4 3 1 2 4 2 2 2 4 2 2 1 5 5 1 4 4 Up to 21 available configurations to support your research. Excitation Fluorescence Channels Fluorochromes FITC, Alexa Fluor 488, 525/40 BP CFSE, Fluo-3 585/42 BP PE, PI 488nm ECD, PE-Texas Red, 610/20 BP PE-CF594, PI PC5, PC5.5, PerCP, 690/50 BP PerCP-Cy5.5, PI 780/60 BP PC7 660/20 BP APC, Alexa Fluor 647, efluor 660 APC-Alexa Fluor 700, Alexa Fluor 712/25 BP 700 638nm APC-Alexa Fluor 750, 780/60 BP APC-Cy7, APC-H7, APC-eFluor 780 Pacific Blue, V450, efluor 450, 450/45 BP BV421 Krome Orange, AmCyan, V500, 525/40 BP BV510 405nm 610/20 BP Violet610, BV605, Qdot 605 660/20 BP Violet660, BV650, Qdot 655 Violet780, BV785, 780/60 BP Qdot 800 The CytoFLEX system can accommodate a variety of fluorophore options.

BrdU Proliferation Cell Cycle Analysis of proliferating cells by BrdU incorporation and 7-AAD staining of Human peripheral blood mononuclear cells (PBMCs).

Sharpen Your Application Sensitivity CytoFLEX analyzes and integrates data from a variety of applications and sample types. Detect rare events and easily accommodate a variety of fluorochromes. Reliable sample acquisition and fluidics delivery allows for acquisition from microtiter tubes and sample volumes as small as 10 µl. With excellent fluorescent sensitivity across any configuration you choose, your results will surpass current systems. CytoFLEX also boasts a large variety of multi-parameter applications, with up to 15-parameter detection and detection of particle sizes as small as 200 nm. Nanoparticle Detection Volumetric Counts The volumetric sample injection module with its patent pending peristaltic pump enables volumetric sampling without the use of expensive beads. Absolute Count without Reference Beads Unique sample delivery using a patent-pending pump mechanism allows for absolute counting of Escherichia coli bacteria without using count calibration beads. Cytometric Detection Of Regulatory T Cells Microparticle Detection. Bead based small particles were detected using side scatter and VSSC. Data provided by Dr. Huang Yijun, Sun Yat-Sen University, School of Medicine, Guangzhou, China. Human PBMCs Mouse Spleen Optimal resolution for low expressed antigens. Regulatory T cells characterized by low levels of expression were easily identified.

Economic Efficiency Save Sample <10µL minimum sample volume Save Reagent Up to 50% less reagent* Save Maintenance Alignment free Save Space 16.7in / 40cm cube Save Time Self installable Save Training Run assays in minutes Save Costs CytExpert analysis software is free Save Sanity Easy to learn, easy to use *compared to five- or six-color analysis approach. 12 Color Immunophenotyping. 12 color antibody detection of Naïve/Memory T cells and T regulatory cells showing human PBMCs stained with CD57 FITC, CD25 PE, CD3 PerCP-Cy5.5, CD45RO PE-Cy7, CD56 APC, CCR7 AF700, HLA-DR APC-Cy7, CD127 BV421, CD8 V500, CD4 BV650, CD16 BV711, and CD19 BV785. Ready. Set. Flow! CytoFLEX is self-installable in less than an hour after opening the box, and its compact size fits most biosafety cabinets. Plus, with CytExpert acquisition and analysis software, you won t miss a beat.

CytExpert acquisition software CytoFLEX s easy-to-run, easy-to-learn software enables cytometrists at all experience levels even novice users to get up and running quickly. The innovative and intuitive software lets you set up high color applications with confidence using the unique Compensation Library. Compensation Library lets you store a repository of compensation spillover values of dyes in a library to easily determine the correct compensation matrix with new gain settings. CytExpert analysis software Powerful CytExpert software delivers high quality, publication-ready data, and ultimate ease of use. Dot Plot Density Plot CytExpert softwarecontour offers flexibleplot analysis templates and plotting tools for Histogram easy and efficient data analysis. Pseudo Plot Overlay

Working Together Sets Us Apart Expert Feature Your Advantage Auto Delay Auto-mixing when loading sample Auto Threshold Axis Pan Batch Function Bead-free Absolute Count Compensation experiment configuration can be modified after data collection. EMF File Format Intuitive GUI tools for compensation and gain threshold. Linear Gain/Voltage Multiple sample types (bead/cell) can be used in compensation experiment. The system reads and automatically adjusts laser delay during QC. You can also read the laser delay value while acquiring sample. You can enable and adjust the sample mixing time. Easily find target population. No need to worry about the threshold setting while adjusting gains when this function is enabled. An ideal tool for visualizing across a high dynamic range axis. You can easily pan across the axis range to search if there is important data out of range. A tool for "gold panning". Many batch processing functions can be selected to improve efficiency of setup and analysis, such as batch exporting plots and statistics, batch creating plots. No expensive beads required. You can read the sample concentration easily from the statistics window. Add new single stained tubes to a previously saved compensation experiment. Save time, reagents and sample. Vector format graphic output supports publication ready data. GUI hand tool helps you easily adjust cytometer settings. The background of cell sample and compensation beads can be quite different requiring compensation with both cells and beads. The software will use the right negative population to calculate the correct compensation values. Vector format graphic output supports publication ready data.

Quality assured for today and tomorrow Beckman Coulter is a leading provider of innovative flow cytometry solutions. We offer a wide variety of conjugated antibodies, fluorochromes, and services to help drive your success in cutting edge cell analysis. In particular, Beckman Coulter tandem dyes are well suited for optimal excitation on CytoFLEX, making the most of your data. Our Custom Design Services draw on our wide-ranging expertise in dry reagent processing, dye technology, conjugation, and multicolor cocktail design to develop stable cocktails using highquality antibodies and custom fluorochrome conjugates in either wet or dry reagent format. For more information please visit www.beckmancustomdesign.com Comprehensive cytoflex system accessories Description Part Number CytoFLEX Sheath Fluid 10L B51503 CytoFLEX Daily QC Fluorospheres B53230 Contrad 70 Cleaning Solution 81911 FlowClean Cleaning Agent A64669 VersaComp Antibody Capture Bead Kit B22804 For over 75 years Beckman Coulter has driven innovation. We remain committed to shaping flow cytometry technology to fit seamlessly into your lab s workflow and to provide an optimal user experience. When you choose a Beckman Coulter instrument you receive the highest level of expertise, innovation, and quality assurance.

Choose Beckman Coulter For Benchmark Expertise And Innovation Get higher quality data whatever configuration you choose. Get superior fluorescence sensitivity and excellent resolution of nanoparticles and dim fluorescence in a surprisingly small footprint. Get revolutionary application capabilities with maximum configurability that rival any current cytometer in a system that s easy to set up, learn, use, and maintain. Get time saving, field-installable upgrades for built-in investment protection. Get CytoFLEX and get ready to transform your research. Contact your local Beckman Coulter sales representative. www.beckmancoulter.com CytoFLEX is for research use only. Not for use in diagnostic purposes. CytoFLEX and CytExpert are trademarks of Xitogen Technologies (Suzhou), Inc., a Beckman Coulter company. Beckman Coulter, the stylized logo and fast track to success are trademarks of Beckman Coulter, Inc. Beckman Coulter and the stylized logo are registered in the USPTO. 2014 FLOW-553SB010.14-B