TR1 TR2. Transformer / Relay Adapter. Installation Manual. Rev 1.1 Feb. 22, Deklin Technologies Inc 413 Childe Harolds Lane Brentwood, TN 37027

Similar documents
10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: twrlighting.com IMPORTANT!!!

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Thermoelectric Cooler

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

MD Power Supply -48Vdc +Bias Tee

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

POWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL

AA2-M CONTROLLER IMPORTANT!!!!

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

TABLE OF CONTENTS. Section Paragraph Title Page. ADDENDUM Visual Index Quick Reference. 1 General Information 1-1

WADL Aircraft Segment Installation Description

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

G500H Flight Display System STC Installation 005-C Rev 3 Master Drawing List Page 2 of 13

ISIMET. E Series Enclosure. Custom Assemblies Installation, Maintenance, and Operation Instructions

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL

621SA-SERIES SERVICE MANUAL

RJE INTERNATIONAL, INC. U LB-364EL R EV 3.2

Bed Docker. Installation Manual. Model BD 600/601

General-Purpose Scale Bases

RJE INTERNATIONAL, INC.

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

Signal Follower Card. Instruction Manual Model C

INSTALLATION MANUAL RECTANGULAR COLUMN

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Ecologix Environmental Systems, LLC

INSTALLATION & OPERATION INSTRUCTIONS ICW-3 WINDOW INTERCOM

OPERATION AND INSTALLATION MANUAL

ALTRONIC RESEARCH, INC.

USER MANUAL MODEL 1019 and 1019S DB-9 Async. Short Range Modem With Transformer Isolation

Global Water Instrumentation, Inc.

Sby SR Instruments, Inc.

Record of Revisions REV DESCRIPTION DATE APPROVED IR INITIAL RELEASE E /07/2016 BH

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz

User s Manual. June 23, 2017 P/N Revision D. TURNER DESIGNS 1995 N. 1 st Street San Jose, CA Phone: (408) FAX: (408)

RJE INTERNATIONAL, INC. STI- 350 R EV 2.2

Global Water globalw.com. Global Water. Instrumentation, Inc.

INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL

3601 E. 34th St. Tucson, AZ USA Tel Fax Web:

INSTALLATION PROCEDURE

CFL Series User Manual

400W Series Instructions for Continued Airworthiness

4-Wire Buffer Amplifier. User Manual

Qualstar Technical Support

GWX 68 Weather Radar Installed in Beech Queen Air/King Air Series. STC Master Data List

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. MPL Digital Pedestal. Manual Version 0.2

FTW 175 Wireless Monitoring System Reference Manual Part Number

FORM FOOTWALL. FORM FOOTWALL (floating) (floating) Installation Manual

Dynatronics Parallel Bars

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount)

VI PARTS LIST. , ELECTRIC FRYER PARTS LIST ITEM DESCRIPTION MODELS PART # 10x x24

HT829 Humidity Transmitter HT839 Humidity and Temperature Transmitter Installation and Operating Instructions

Wash Down Duty Non-Contact Sensor

Model 10A. Model 20A. Operating Manual. ECG Simulator. ECG / Arrythmia Simulator

Field Economy Unit Instruction Manual

OptoLum MegaLine RGBW Luminaire

ER6-SERIES1:6 SERVICE MANUAL

Product Specifications MRI Trench Duct FR1

PAGODA SERIES OPERATOR'S MANUAL

Sageon Site Monitor (SSM) Application Note

PORTABLE CHAIR SCALES BEAM and DIGITAL TYPES MODELS 475, 4751, 6475, 6475k and 6475KGEU

MANUAL. ENGLISH Antenna Booster Ordercode: D1425. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

RL4050LS. Electronic Load Shackle. Installation Guide

WLC60 Heavy Duty LED Light

Address: City: State: Zip: Day Phone: Fax: 5. Where Were Your Products Purchased and/or Installed: Installer s Name/Company:

Stretch Wire. P/N Rev. 2. IOM Stretched wire festoon manual

DMX-BRANCH/4. user manual. ELATION DMX-BRANCH/4 user manual

FIXED CEILING COLUMN. Installation Manual FIXED CEILING COLUMN

Product Specifications MRI Trench Duct

ENSTROM TH-28/480 SERIES MAINTENANCE MANUAL SUPPLEMENT 7 BAMBI BUCKET INTERFACE KIT P/N

DUST FREE ACTIVE Total Home Air Purification

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

P1902 Installation Manual

OPTO BRANCH 8. ELATION OPTO BRANCH 8 user manual 1.0

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

Installation Manual. Omnicell. Model: 9101 FB by Fairbanks Scales, Inc. Revision 2 03/16 All rights reserved

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

P R I C E L I S T 1

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

Festoon Manual Heavy Duty C-Track

Dancer Duty Potentiometer

SERVICE PEDESTAL FLOOR-MOUNTED SERVICE PEDESTAL. Installation Manual

Gerber Scientific Products

Installation Manual. Omnicell. Model: 9102 FB by Fairbanks Scales, Inc. Revision 4 08/16 All rights reserved

INSTALLATION INSTRUCTIONS FOR. MODEL MSBULTB LED

ER6-SERIES1:6 SERVICE MANUAL

Transcription:

TR1 TR2 Transformer / Relay Adapter Installation Manual Rev 1.1 Feb. 22, 2016 Deklin Technologies Inc 413 Childe Harolds Lane Brentwood, TN 37027 Tel: (615) 819-0800 Fax: (615) 819-0801 www.deklintech.com

REVISIONS REV DESCRIPTION DATE APPROVAL 1.0 Initial Release Aug 22, 2014 JAD 1.1 Added note about connector pins Feb 22. 2016 JAD

TABLE OF CONTENTS Section I General Information 1 INTRODUCTION 1 SCOPE 1 EQUIPMENT DESCRIPTION 1 SPECIFICATIONS 2 General Specifications 2 Input Specifications 2 Component List TR1 (Century 21/31/41/2000/4000) 2 Component List TR1R (Century 21/31/41/2000/4000 with Flight Director) 2 Component List TR2 (Century IIB/III/IV) 2 Component List TR2R (Century IIB/III/IV with Flight Director) 2 EQUIPMENT SUPPLIED 3 OPTIONAL PARTS 3 Section II - Installation 4 GENERAL INFORMATION 4 Scope 4 Installation Requirements 4 Unpacking and Inspection 4 INSTALLATION PROCEDURES 4 Cooling Requirements 4 Mounting Requirements 4 Cable Harness Wiring 4 Noise 5 Post Installation Check 5 Operational Checkout 5 Section IV Warranty and Service 6 WARRANTY 6 FACTORY SERVICE 6 Appendix A - Schematics 7 Appendix B - Mechanical 11 Deklin Technologies, Inc. 2011

Section I General Information INTRODUCTION This manual contains information regarding the physical, mechanical, and electrical characteristics, plus, the installation requirements for the TR1 and TR2 series Transformer/Relay adapters. SCOPE This manual provides detailed installation instructions for the TR1 and TR2 series Transformer/Relay adapters. EQUIPMENT DESCRIPTION The Deklin Technologies, Inc. TR1 and TR2 series Transformer/Relay adapters are a pre-assembled autopilot interface unit following the interconnect specifications and component requirements recommended by the manufacturers of certain PFD systems when interfaced with existing autopilots. It is intended to provide a convenient solution in a single device with multiple variations for installers to use in place of producing the same circuits from discrete components as specific in PFD installation manuals. The installer is responsible to certify as airworthy and determine eligibility of this product for installation in accordance with FAA Parts 21 and 43, IAW AC20-62E, Section 11, Paragraph a. 11. ELECTRICAL PARTS AND INSTRUMENTS. a. Electronic Kits. Kits assembled by non-certificated individuals are not eligible for installation on TC d aircraft until the part is certified as airworthy and found eligible for installation in accordance with parts 21 and 43. During and after assembly, these kits should receive documented conformity inspections by properly certificated persons to ensure that they meet all applicable airworthiness requirements for use on the specific aircraft on which they are to be installed. The installation of these approved units should be accomplished by or under the supervision of a properly certificated person or agency in accordance with parts 21 and 43. When the installation is a major alteration, the kit data and the data used for the alteration of the product must be approved by a representative of the Administrator. An appropriately certificated person must complete the maintenance records to ensure that the aircraft is approved and airworthy for return to service. After inspection the installer should validate they have inspected this device by noting their name on the product label in the appropriate location marked Installer/Inspector. The absence of a signature does not release the installer from the responsibility of validating this product nor does it place any responsibility on Deklin Technologies, Inc. The TR1 and TR2 series Transformer/Relay adapters standard features:! Aspen EA100 to Century series autopilot! Same pin out configuration! Small size! D-Sub connector! Easily mounted Deklin Technologies, Inc. 2014 1

SPECIFICATIONS General Specifications Case Material: Dimensions: (not including mating connector) Weight without Relay: Weight with Relay Connectors: Mounting: Input Specifications Relay Rated Voltage: 28VDC Relay Coil Resistance: 320 OHMs +/- 10% Current Rating: 10 Amps MIL STD: M83536/10-027 5052H32 Aluminum Chassis and Cover 4.60 (116.8mm) X 2.56 (65.0mm) X 1.50 (38.1mm) 0.38 lbs (0.17 kg) 0.60 lbs (0.27 kg) 25 Pin Female D-Sub Connector Bulkhead, Four 8/32 Screws Component List TR1 (Century 21/31/41/2000/4000) Housing: 5052H32 Aluminum Chassis and Cover Resistors: 0 Ohm Jumper Transformers: Sp-66 (x3) Component List TR1R (Century 21/31/41/2000/4000 with Flight Director) Housing: 5052H32 Aluminum Chassis and Cover Resistors: 0 Ohm Jumper Relay 24VDC FCA-210-1027M Relay 12VDC FCA-210-0917M Transformers: Sp-66 (x3) Component List TR2 (Century IIB/III/IV) Housing: 5052H32 Aluminum Chassis and Cover Resistors: 2.2k Ohm, 1.2k Ohm, 0 Ohm Jumper Capacitor: 0.12uF 50V 10% Transformers: Sp-20 (x1), SP-69 (x2) Component List TR2R (Century IIB/III/IV with Flight Director) Housing: 5052H32 Aluminum Chassis and Cover Resistors: 0 Ohm Jumper Capacitor: 0.12uF 50V 10% Relay: FCA-210-1027M Relay 12VDC FCA-210-0917M Transformers: Sp-20 (x1), SP-69 (x2) Deklin Technologies, Inc. 2014 2

EQUIPMENT SUPPLIED 1 each TR1 or TR1R or TR2 or TR2R OPTIONAL PARTS 1 each AIU-900IK Installation Kit consisting of: 1 each 25 pin Male D-Sub connector w/pins * 1 each SPC15461 Hood or equivalent 1 each Screw locking hardware kit * Note: If you are supplying your own connector and pins you must ensure the pins fit snuggly in the sockets of the connector. Some Mil Spec pins, and pins used in high density D-Sub connectors do not fit properly and will cause intermittent connections. Deklin Technologies, Inc. 2014 3

Section II - Installation GENERAL INFORMATION Scope This section provides detailed installation and interconnection instructions for the TR1 and TR2 series Transformer/Relay adapters. Please read this manual carefully before beginning any installation to prevent damage and post installation problems. Installation of this equipment requires special knowledge and tools. Installation Requirements The TR1 and TR2 series Transformer/Relay adapters require specialized knowledge and tools for an effective installation. An appropriately rated Certified Repair Station must install this equipment in accordance with applicable regulations. Deklin Technologies, Inc warranty is not valid unless installed by an authorized FAA approved repair station. Failure to follow any of the installation instructions, or installation by a non-certified individual or agency will void the warranty and may result in a nonairworthy installation. Unpacking and Inspection Use care when unpacking the equipment. Inspect the unit and all the parts supplied for visible signs of shipping damage. Examine the unit for loose or broken pieces. Verify the correct quantity of components supplied with the list in Section I. If any claim is to be made, save the shipping material and contact the freight carrier. DO NOT return any items damaged in shipping to Deklin Technologies, Inc. If any items show signs of external shipping damage, contact Deklin Technologies, Inc for a replacement. Do not attempt to install a damaged unit. Equipment returned to Deklin Technologies, Inc for any other reason should be shipped in the original packaging, or other UPS approved packaging. INSTALLATION PROCEDURES The following is provided for general reference. Primary instruction for the installation of this product should be from the Installation Manual of the OEM product for which this device will be used with. Cooling Requirements Forced air-cooling is not required for the TR1 and TR2 series Transformer/Relay adapters. However, the equipment should be kept away from heat sources without adequate cooling provided. (i.e. defrost or heating ducts, dropping resisters, heat producing avionics.) Mounting Requirements The TR1 and TR2 series Transformer/Relay adapters must be mounted inside the pressure vessel in a temperature controlled environment unless the aircraft s service ceiling is less than 25,000 feet. The TR1 and TR2 series Transformer/Relay adapters must be rigidly mounted to a secure structure in accordance with FAA Advisory Circular AC 43.13-2B. The unit should be mounted in an area with adequate clearance for the unit and associated wiring. Cable Harness Wiring Refer to the included wiring diagrams for pin out configurations. All wires must be MIL-SPEC in accordance with current regulations. All shielded wire should be MIL-C-27500 or equivalent (with solder sleeves for shield termination) and must be used where specified. Proper stripping, shielding and soldering techniques must be used at all times. Deklin Technologies, Inc. 2014 4

Refer to FAA Advisory Circular AC 43.13-2B for more information. Failure to use correct techniques may result in improper operation, electrical noise, and/or unit failure. Damage caused by improper installation will void warranty. Noise Due to the variety and high power of equipment in today s aircraft, there is a potential for both electrical and conducted noise interference. To minimize the occurrence of noise being introduced into the system, please follow these installation guidelines. Do not bundle any lines from this unit with transmitter coax lines. Do not bundle any lines from this unit with any other audio or high voltage power lines. Do not bundle any lines from this unit with 400 Hz synchro wiring or AC power lines such as strobes or inverters. Do not position this unit or route wiring from this unit next to any device with a strong alternating magnetic field such as an inverter. Use shielded wire where shown and ground as indicated. Post Installation Check After installation wiring is complete, verify no power is on any pin and airframe ground on pin 5 only. Operational Checkout Follow instructions in specific OEM PFD Installation Manuals for check out procedures. Deklin Technologies, Inc. 2014 5

Section IV Warranty and Service WARRANTY Deklin Technologies, Inc. warrants this product to be free from defect in workmanship and material for a period of 24 months from the time of installation or 26 months from the factory shipping date. This warranty is valid only if the equipment is installed in an aircraft by a FAA certified avionics facility (or other ICAO agency). If during the warranty period this unit should fail it will be at the discretion of Deklin Technologies, Inc to send a replacement unit or repair the original unit. All units must be returned to the factory for repair or replacement. All shipping and handling charges for the return of a unit to the factory are the responsibility of the purchaser. Domestic UPS Ground shipping charges for sending an exchange or repaired unit to the customer will be the responsibility of Deklin Technologies, Inc. Any additional charges as a result of requested improved delivery time, alternate carrier, insurance, or handling costs are the responsibility of the customer. All freight, handling, insurance, brokerage fees, duties and taxes for shipments outside the continental United States is the responsibility of the customer. Deklin Technologies, Inc shall not be liable for incidental or consequential damages. This warranty does not cover a defect that has resulted from improper handling, storage or preservation, unreasonable use, or maintenance. This warranty is void if there is any attempt to dissemble this product without factory authorization. This warranty does not cover expenses incurred for the removal and/or installation of this product. All items repaired or replaced under this warranty are warranted for the remainder of the original warranty period. Deklin Technologies, Inc reserves the rights to make modifications or improvements to the product without obligation to perform like modifications or improvements to previously manufactured products. FACTORY SERVICE In the event any unit needs to be returned to the factory, contact Deklin Technologies, Inc for a Return Authorization Number prior to returning. Units that arrive without a Return Authorization Number, or telephone number, will be returned unrepaired. Deklin Technologies, Inc is not responsible for items returned via Mail. Deklin Technologies, Inc. 2014 6

Appendix A - Schematics Deklin Technologies, Inc. 2014 7

Deklin Technologies, Inc. 2014 8

Deklin Technologies, Inc. 2014 9

Deklin Technologies, Inc. 2014 10

Appendix B - Mechanical Deklin Technologies, Inc. 2014 11