HILLCREST MANOR Palo Verde, California

Similar documents
ADAPT-PT 2010 Tutorial Idealization of Design Strip in ADAPT-PT

ADAPT-PTRC 2016 Getting Started Tutorial ADAPT-PT mode

ADAPT-BUILDER : General Analysis/Design Options

ADAPT PT7 TUTORIAL FOR BEAM FRAME 1

STRESS CHECK AND REBAR VERIFICATION

DESIGN PROCESS USING ADAPT-BUILDER PLATFORM

ADAPT-PT 2010 GETTING STARTED GUIDE

ADAPT PT7 TUTORIAL FOR ONE-WAY SLAB 1

DESIGN FOR PROGRESSIVE COLLAPSE 1

ADAPT-PT 2012 GETTING STARTED GUIDE

ADAPT-Builder Express (EX) v3. Summary of New Features

STRENGTH EVALUATION OF A CRACKED SLAB REINFORCED WITH GROUTED TENDONS 1

ADAPT Floor Pro 2009/2010 Tutorial Export Design Strip to ADAPT PT or ADAPT RC

COMPARISON OF MULTISTORY WALL RESULTS BETWEEN ADAPT-EDGE 1 AND ETABS 2 CONCRETE FRAME WITH SHEARWALLS

ADAPT PT7 TUTORIAL FOR A NON-PRISMATIC SLAB 1

OVERVIEW OF ADAPT PRODUCTS

Third Avenue New York, NY. Structural Concepts/ Structural Existing Conditions Report September 30, Michelle L.

MASONRY WALL DATA: Wall Height = ft. Nominal Wall Thickness = 8.00 in. Depth to c.g. Steel, Wall = 3.81 in.

SHEAR DESIGN IN FLOOR SLABS 1

Precast Concrete Bearing Wall Panel Design (Alternative Analysis Method) (Using ACI )

Reinforced Concrete Spread Footing (Isolated Footing) Analysis and Design. Design Footing

STRUCTURAL CONCRETE SOFTWARE SYSTEM ADAPT-FLOOR PRO. Version EX 3.20 USER MANUAL. Copyright 2007, 2008

Design of Reinforced Concrete Slabs

Multi-Story Solid Tilt-Up Wall Panel Analysis and Design (ACI 551)

Agricultural Hall and Annex East Lansing, MI. Structural Design. Gravity Loads. 1- Based on US Standards

Structural Option April 7 th, 2010

Introduction to. Asian Center for Engineering Computations and Software. ACECOMS & AIT Solutions 1

GUIDELINES FOR EXECUTION OF ADAPT-PT 1

Structural Engineering, Mechanics, and Materials. Preliminary Exam - Structural Design

A Finite Element Approach to Reinforced Concrete Slab Design in GT STRUDL

Reinforced Concrete Tilt-Up Wall Panel Analysis and Design (ACI 551)

ANALYSIS TOOLS FOR THICK CONCRETE SLABS 1

Table of Contents 2. Structural Systems.4 Foundations.4 Floor System...4 Columns..5 Lateral System...5

Technical Note Structural Concrete Software System

Design Example 2 Reinforced Concrete Wall with Coupling Beams

Analysis and Design of One-way Slab System (Part-I)

Reinforced Concrete Tilt-Up Wall Panel with Opening Analysis and Design (ACI 551)

North Mountain IMS Medical Office Building

DEFLECTION OF CONCRETE FLOOR SYSTEMS FOR SERVICEABILITY 1

Prestress Superstructure Tutorial

CONCRETE TECHNOLOGY CORPORATION

Fundamentals of Post Tensioned Concrete Design for Buildings

ADAPT-Floor Pro 2009 Tutorial Export Design Strip to ADAPT-PT or ADAPT-RC

Software Verification

A SAFETY CONSIDERATION IN DESIGN OF CONCRETE FLOOR SYSTEMS USING FINITE ELEMENTS 1

BrD Superstructure Tutorial

TREATMENT OF BEAMS IN FLOOR PRO

Technical Assignment 1 10/8/03

Fz LLC. Exclusive Distributor in the Middle East for CSI Software licensing, technical support and training solutions

STRUCTURAL CONCRETE SOFTWARE ADAPT RC For Design of Reinforced Concrete Floor Systems and Beam Frames USER MANUAL.

One-Way Wide Module Joist Concrete Floor Design

Alexis Pacella Structural Option Dr. Schneider Lexington II, Washington D.C. Technical Report #3 November 21,

111 MORGAN ST. Ryan Friis

CHAPTER 5 FINITE ELEMENT MODELLING

Topic Outline. Two Stage Analysis Procedure: Podium Design. Part 2: Rigid Lower Portion Philip Miller, S.E. 2/8/2018

LEARNING OF ETABS. 15 ft

REINFORCING TABLES INSTALLATION MANUAL

NCMA TEK. TEK 14-5A Structural (2006) LOADBEARING CONCRETE MASONRY WALL DESIGN

Structural Technical Report I October 5, 2006 Structural Concepts / Structural Existing Conditions Report

Hyperstatic (Secondary) Actions In Prestressing and Their Computation

Cantilever or Restrained Retaining Wall Calculations

Sabah Shawkat Cabinet of Structural Engineering 2017

Technical Notes POST-TENSIONED T- BEAMS; EFFECTIVE WIDTH; TEMPERATURE TENDONS AND UNDESIRABLE EFFECTS 1. Bijan Aalami 2

IMPLEMENTATION OF DEFLECTION WITH ALLOWANCE FOR FLEXURAL CRACKING IN ADAPT-PT

Xyston Inn. NY. Proposal. Xiaodong Jiang. Structure Option. Advisor: Dr. Linda Hanagan

Slab Bridge Designer 2.1 Help: Example Analysis

Stability Analysis of A L-Shaped Building with Mat Foundation Under Soil-Structure Interaction Approach NAW THAW THI OO 1, DR.

THE FORENSIC MEDICAL CENTER

STRUCTURAL CONCRETE SOFTWARE ADAPT RC For Design of Reinforced Concrete Floor Systems and Beam Frames USER MANUAL.

STRUCTURAL CONCRETE SOFTWARE ADAPT-MAT USER MANUAL. Copyright June 2016

Erie on the Park. Timothy Moore Penn State University Architectural Engineering Structural Emphasis Advisor: Prof. Ali Memari

Executive Summary Building Description: Introduction... 13

Park Potomac Office Building E

From Park and Gamble Book.

CONCRETE TECHNOLOGY CORPORATION

EngSolutions RCB. Analysis & Design of Reinforced Concrete Buildings for Earthquake and Wind Forces

Structural Study of the Existing Lateral System

Pyramid Structural Engineering Applications

Effect of Edge Beam and Shear Wall on the Structural Behavior of Flat Plate Multistoried Building: A Computing Modeling for lateral load Analysis

Third Avenue New York, NY. Lateral System Analysis and Confirmation Design November 13, Michelle L. Mentzer.

Xyston Inn. NY. Proposal. Xiaodong Jiang. Structure Option. Advisor: Dr. Linda Hanagan

Lightweight Steel Framing. Composite DeltaStud Load Tables

FINITE ELEMENT ANALYSIS OF REINFORCED CONCRETE BRIDGE PIER COLUMNS SUBJECTED TO SEISMIS LOADING

Atkinson Engineering, Inc.

William W. Wilkins Professional Building

VIBRATION EVALUATION OF FLOOR SYSTEMS FOR FOOTFALL USING ADAPT-FLOOR PRO

CE 160 SAP 2000 Notes for 2D Problems. Element and Joint Drawing Tools Global Coordinates of Cursor Position Units in View Window

OVERALL STRUCTURAL SYSTEM

CADS A3D MAX. How to model shear walls

EVALUATION OF COLLECTOR DESIGN FOR CONCRETE DIAPHRAGMS

Comparative Study of Irregular-shaped RC Building with Different Lateral Load Resisting Systems

DESIGN OF VERTICAL SHEAR IN TRANSFER PLATES 1

SEAU 5 th Annual Education Conference 1. ASCE Concrete Provisions. Concrete Provisions. Concrete Strengths. Robert Pekelnicky, PE, SE

Brent Ellmann Structural Option 200 Minuteman Park, Andover, MA Structural Consultant: Dr. Hanagan

The SP Suite has the capability to design an entire concrete structure from foundation to roof. These programs are based on the methods, equations,

HIGH RISE CONDO SOHO, NEW YORK, NY

Introduction to Statically

Modjeski and Masters, Inc. Consulting Engineers 04/18/06 St. Croix River Bridge 3D Analysis Report Introduction

Southwest Housing, Arizona State University

MOUNTAIN STATE BLUE CROSS BLUE SHIELD HEADQUARTERS

Transcription:

STRUCTURAL ENGINEERING CONSULTANTS TN358_MAT_RC_desogm_example_040110 HILLCREST MANOR Palo Verde, California Structural Design of Mat (Raft) Foundation First draft ADAPT Corporation Redwood City, CA, USA ADAPT International ADAPT Latin America Kolkata, India Miami, FL, USA www.adaptsoft.com Tel: +1 (650) 306 2400 Fax: +1 (650) 306 2401 ADAPT Europe Zurich, Switzerland

LIST OF CONTENTS OVERVIEW 1 - STRUCTURE 2 - MATERIAL 3 - DESIGN CRITERIA 3.1 Design Code 3.2 Code Compliance Checks 3.3 Load Combinations 4 GEOMETRY AND BOUNDARY CONDITIONS 5 - LOADS 6 BASE REINFORCEMENT 7 OTHER REINFORCEMENT 8 - PRESTRESSING 9 - ANALYSIS 9.1 Discretization 9.2 Load Cases and Load Combinations 9.3 Deflections 9.4 Soil Pressure 10 - DESIGN VALUES 10.1 Design Strips 10.2 Design Sections 10.3 Design Values 11 - REINFORCEMENT 12 - PUNCHING SHEAR OVERVIEW Hillcrest Manor is a low rise building to be constructed on soil with a low allowable bearing pressure. A conventionally reinforced mat (raft) foundation is selected, proportioned and designed, such as to spread the load from the walls and columns above over the entire footprint of the building. The objective of the design has been to distribute the load to a relatively uniform pressure not to exceed the allowable values of the soil. The calculations presented herein cover the principal steps in the design of the mat (raft) foundation as it would be carried out in a structural engineering consultant s office. The difference being that many of the repetitive numerical reports generated by the analysis and design program used (ADAPT-Mat) are referred to, but left out for brevity without compromising the essential features of the work. 1 - STRUCTURE The foundation mat (raft) consists of a contiguous conventionally reinforced concrete slab covering the entire footprint of the building. The top level of the mat is level. At locations of higher loads from above, such as below selective walls, the mat is thickened to achieve a more uniform distribution of pressure below the mat. Details of the mat configuration are reported in the section on Geometry. 2

2 - MATERIAL Concrete: Weight = 150 pcf Cylinder Strength at 28 days for slabs = 4000 psi Modulus of Elasticity = 4028 ksi Creep Coefficient = 2 Non-prestressed Reinforcement: Yield Strength Modulus of Elasticity Soil Bulk modulus Allowable long-term pressure Short term transient pressure = 60 ksi = 30000 ksi = 150 pci = 2000 psf = 1.33*2000 = 2,667 psi 3 - DESIGN CRITERIA 3.1 Design Code The design is based on ACI 318-2008; IBC 2009 3.2 Code Compliance Checks The foundation mat (raft) is designed to meet the following criteria: Not to exceed soil pressure in sustained load condition Not to exceed soil pressure in transient load condition (earthquake) Design capacity for bending and shear exceeding design values (Ultimate Limit State) Punching shear capacity below column supports The available option in the analysis and design program for providing a minimum shrinkage reinforcement will not be invoked, since this is deemed not to be intended for RC mats. 3.3 Load Combinations The applicable load combinations are reported in section 9.2 4 GEOMETRY AND BOUNDARY CONDITIONS The mat (raft) foundation is made up of a contiguous slab with overall dimensions 93.33 x 54.88 ft (Fig. 4-1). The mat thickness varies between 12 to 30 in. Slab bands of 30 thickness are provided below selected walls as shown on plan. 3

FIGURE 4-1 GENERAL LAYOUT AND DIMENSIONS FIGURE 4-2 SECTIONS SHOWING CHANGE IN THICKNESS OF MAT 4

The structural model of the mat includes a level of walls and columns above the mat as shown in the 3D view of the analysis/design model (Figs. 4-3). FIGURE 4-3 VIEW OF ANALYSIS/DESIGN MODEL THAT FEATURES ONE LEVEL OF WALLS AND COLUMNS ABOVE 5 - LOADS The loads on the mat consist of the following: Selfweight (Selfweight) Based on concrete volume = 150 pcf Dead Load (Dead load) Consist of concentrated loads on top of columns, and Line loads distributed on top of the walls. The dead load includes roof load. These are shown graphically in Figs. 5-1. 5

(a) Concentrated Dead Load (kip) (b) Line Dead Load (k/ft) FIGURE 5-1 SUPERIMPOSED DEAL LOAD 6

Live Load (Live load) Distributed uniform load over the entire mat = 100 psf Line load at top of walls typically 2 to 3 k/ft as shown in 5-2 Concentrated Live Load(kip) 7

(b) Line Live Load (k/ft) FIGURE 5-2 LIVE LOAD 8

Roof Live Load (Roof_LL) Distributed as concentrated loads over the columns and uniform line loads over the walls above the mat (see 5-3 for values) FIGURE 5-3 CONCENTRATED ROOF LIVE LOAD (kip) Earthquake Loads Earthquake action in X-direction (along the long axis) (Load EQ-X, see 5-4a) Earthquake action in Y-direction (along the short axis) (Load EQ-Y, see 5-4b) 9

Earthquake Load in X-X direction (long-direction) Earthquake Load in Y-Y direction (short direction) FIGURE 5-4 EARTHQUAKE LOAD 10

6 BASE REINFORCEMENT Base reinforcement is the rebar placed in the mat at user selected locations prior to the analysis and design. The program will consider these as provided rebar, and will report the reinforcement that may be necessary for code compliance in addition to the user defined base reinforcement. Bottom base reinforcement #4 @ 12 o.c. along X-X (long direction) cover 3 #4 @ 12 o.c. along Y-Y (long-short) cover 3.5 Top base reinforcement #4 @ 24 o.c. along X-X (long direction) cover 1 from top #4 @ 12 o.c. along Y-Y (long-short) cover 1.75 from top 7 OTHER REINFORCEMENT Reinforcement, where necessary to meet the design specifications and the governing code, will be calculated by the program and reported in amount, size, location and length. Refer to Section 11 for the design outcome and details. 8 - PRESTRESSING No prestressing is specified. The mat is analyzed and designed as a conventionally reinforcement concrete structure. 9 - ANALYSIS 9.1 Discretization Using ADAPT-Mat computer program, the structure is discretized in well proportioned quadrilateral finite element cells for improved results. All cell vertices meet at common nodes to guarantee the equilibrium of applied loads with the analysis results. The discretization used is shown in Fig. 9.1-1 11

FIGURE 9.1-1 VIEW OF THE FINITE ELEMENT MESH USED FOR DESIGN 9.2 Load Cases and Load Combinations The load cases and load combinations defined are reported by the program and reproduced below. The load combinations are automatically generated by the program, once the design code is selected. The user has the option to edit the program generated load combinations, however. Each load combination is evaluated by the program for code compliance using one of the several building code required evaluation options. The default evaluation options of the program depend on the building code selected by the user. The evaluation option used by the program for each of the load combinations is reported preceding each load combination cases as noted below: The evaluation options used for this project are: Service Total Load Reports deflections, actions (moments, etc) and associated minimum rebar, if needed beyond user defined base reinforcement Service Sustained Load Reports deflections, actions (moments, etc) and associated minimum rebar, if needed beyond user defined base reinforcement. This load combination is used for long-term deflection. Strength Calculates and reports rebar needed for strength requirements of the code, beyond what the user has defined as base reinforcement 12

Other evaluation options, such as cracked deflection are not used in this project. The following list of load cases and load combinations are excerpts from the program s reports for this project. LOAD CASES Dead load Live load Selfweight Load EQ-X Load EQ-Y Roof_LL LOAD COMBINATIONS Name: Service(Total Load) Evaluation: SERVICE TOTAL LOAD Combination detail: 1.00 x Selfweight + 1.00 x Dead load + 1.00 x Live load + 1.00 x Roof_LL Name: Service(Sustained Load) Evaluation: SERVICE SUSTAINED LOAD Combination detail: 1.00 x Selfweight + 1.00 x Dead load + 0.30 x Live load + 0.30 x Roof_LL Name: Strength(Dead and Live) Evaluation: STRENGTH Combination detail: 1.20 x Dead load + 1.60 x Live load + 0.50 x Roof_LL + 1.20 x Selfweight Name: Service_EQ_YY Evaluation: SERVICE TOTAL LOAD Combination detail: 1.00 x Selfweight + 1.00 x Dead load + 1.00 x Live load + 1.00 x Roof_LL + 0.70 x Load EQ-Y Name: Service_EQ_XX Evaluation: SERVICE TOTAL LOAD Combination detail: 1.00 x Selfweight + 1.00 x Dead load + 1.00 x Live load + 1.00 x Roof_LL + 0.70 x Load EQ-X Name: Strength_EQ_XX Evaluation: STRENGTH Combination detail: 1.20 x Dead load + 1.20 x Selfweight + 0.50 x Live load + 1.00 x Load EQ-X + 0.20 x Roof_LL Name: Strength_EQ_YY Evaluation: STRENGTH Combination detail: 1.20 x Dead load + 1.20 x Selfweight + 0.50 x Live load + 0.20 x Roof_LL + 1.00 x Load EQ-Y Name: Strength_09DL_EQ_YY Evaluation: STRENGTH Combination detail: 0.90 x Dead load + 0.90 x Selfweight + 1.00 x Load EQ-Y Name: Strength _09DL_EQ_XX Evaluation: STRENGTH Combination detail: 0.90 x Dead load + 0.90 x Selfweight + 1.00 x Load EQ-X 9.3 Deflections The deflection of the mat under the sustained load combination is given in Fig. 9.3 Name: Service(Sustained Load) 1.00 x Selfweight + 1.00 x Dead load + 0.30 x Live load + 0.30 x Roof_LL 13

FIGURE 9.3-1 IMMEDIATE DISPLACEMENT RESPONSE OF THE MAT/SOIL TO THE SUSTAINED LOAD COMBINATION. (Maximum immediate displacement = 0.07 inch) 9.4 Soil Pressure Sustained Load Combination The allowable soil pressure under sustained load combination specified is 2000 psf. The distribution of soil pressure for this load combination is given by the contour line diagram shown in Fig. 9.4-1. From the contour diagram, the maximum point pressure is at the top left corner of the mat. It is equal to 0.0107 * 1000 * 144 = 1,541 psf < 2000 psf (OK) 14

FIGURE 9.4-1 DISTRIBUTION OF SOIL PRESSURE BELOW THE MAT UNDER SUSTAINED LOAD COMBINAITON Comment: Strictly speaking, the allowable soil pressure does not apply to the pressure reported at a point in a contour plot, such as Fig. 9.3-1. The allowable soil pressure intended for the average pressure over a minimum area, such as a square or circle having a diameter or side value between three to four times the slab thickness. In the current design, since the point pressure is within the allowable value, the design is considered acceptable. Otherwise, using the pressure contour, the average pressure over the preceding minimum area would have had to be calculated and checked with the allowable value. Transient Load Combination The allowable soil pressure for the transient load combinations of wind and seismic actions is 2,667 psi. The governing load combinations in the current case are earthquake along X-X and Y-Y directions as given below: Name: Service_EQ_XX 1.00 x Selfweight + 1.00 x Dead load + 1.00 x Live load + 1.00 x Roof_LL + 0.70 x Load EQ-X Name: Service_EQ_YY 1.00 x Selfweight + 1.00 x Dead load + 1.00 x Live load + 1.00 x Roof_LL + 0.70 x Load EQ-Y 15

The analysis results indicates that the soil pressure for the load combination with earthquake along the long direction (X-X) is more critical. The pressure distribution is shown in Fig. 9.3-2. The maximum point pressure is: 0.152 * 1000 * 144 = 2,189 psf < 2,667 psi OK Again, it is re-iterated that as in the case of gravity load case, the average pressure over an area with side dimension three to four times the slab thickness would have been selected to determine the average pressure for code compliance. FIGURE 9.4-2 DISTRIBUTION OF SOIL PRESSURE FOR TRANSIENT LOAD COMBINATION (SEISMIC ACTION ALONG THE LONG DIRECTION X-X) 10 - DESIGN VALUES 10.1 Design Strips To obtain the design values (moments, shears, etc) for mat foundations the standard procedure of subdividing the structure into design strip in two orthogonal directions is applicable. Unlike the elevated conventionally reinforced slabs where the design strips are automatically subdivided into column and middle strips, for mat foundations the design strips typically extend between midpoint of adjacent columns/walls transverse to the direction of a design strip. The design strips are based on the support lines drawn in each direction. Figs. 10.1-1 and 10.1-2 illustrate the selected support lines and the associated design strips. 16

(a) Support line identification (b) Design strips FIGURE 10.1-1 DESIGN STRIPS IN THE LONG DIRECTION (a) Support line identification (b) Design strips FIGURE 10.1-2 DESIGN STRIPS IN THE SHORT DIRECTION 10.2 Design Sections For a complete design and code compliance check of the mat area, design sections are generated in two orthogonal directions over the entire surface of the mat. Design values (moments, shears, etc) are determined for each of the design sections. At the design stage to follow, the program checks the availability of reinforcement at each of the design sections and adds rebar, where necessary. Fig. 10.2-1 illustrates the design sections for each of the two principal directions. 17

(a) Design section for long direction (b) Design sections for short direction FIGURE 10.2-1 DESIGN SECTIONS IN ORTHOGONAL DIRECTIONS 10.3 Design Values Moments, shears and other quantities obtained for each design section and each load combination are enveloped to obtain the applicable maximum and minimum values along each of the design strips. Figs. 10.3-1 and 10.3-2 show the distribution of the design moment envelopes for the two orthogonal directions. The numerical values for the design sections can be seen either graphically, or in tabular forms. For clarity, these are not shown in the figures. FIGURE 10.3-1 ENVELOPE OF MAXIMUM AND MINIMUM DESIGN VALUES FOR STRIPS IN THE LONG DIRECTION 18

FIGURE 10.3-4 ENVELOPE OF MAXIMUM AND MINIMUM DESIGN VALUES FOR STRIPS IN THE SHORT DIRECTION Tabular reports generated by the program give the design values of each design section for each load combination in addition to the envelope of all load combinations. For a sample, Table 10.3-1 lists the design values for a specific load combination and support line. TABLE 10.3-1 TABLE OF SELECTED DESIGN VALUES 1 Load Combination: Strength (Dead and Live) Design Strip: Support Line 7 Design section Moment Shear Axial Torsion k-ft k k k-ft 703000 70.808 15.907 2.650-42.860 703001 44.006 17.211 4.768-35.038 703002 25.163 4.269 7.389-55.281 703003 21.172-1.469 6.780-44.694 703004 26.296 0.164 6.399-51.795 703005 26.400-1.063 6.138-42.333 703006 6.434 17.184 1.404-32.011 703007-17.043 13.322-1.307-9.288 703008-32.096 7.735-4.075-36.369 The envelope of maximum and minimum values from all the load combinations defined for each of the design strips is compiled in the graphical reports of each design strip. Fig. 10.3-5 illustrates this envelope for design strip 7. Negative values refer to tension at the top of the mat. 1 In the Design Section identification column the first digit (7) refers to the support line, the third digit (3) is the number of span along the support line, the remainder of the digits to the right give the design section ID from the face of support at one end of the span to the face of support at the other end. 19

FIGURE 10.3-5 ENVELOPE OF DESIGN MOMENTS FROM ALL LOAD COMBINAITONS FOR DESIGN STRIP 7 11 - REINFORCEMENT The envelope of rebar required in addition to the base reinforcement specified for the project in Section 6 is shown in Figs. 11-1 for the bottom bars. To illustrate the annotation used in reporting the reinforcement, a section of the plan is shown in enlarged view in Fig. 11-2. The program also reports the reinforcement required in tabular form for each of the load combinations, as well as the envelope of all load combinations. 20

FIGURE 11-1 BOTTOM REBAR IN ADDITION TO BASE REINFORCEMENT FIGURE 11-2 ENLARGED VIEW OF A SLAB REGION SHOWING THE REQUIRED BOTTOM REBAR Top bar is required at one location only as illustrated in Fig. 11-3. The base reinforcement specified covers the requirements for other locations. 21

FIGURE 11-3 TOP REBAR IN ADDITION TO BASE REINFORCEMENT 12 - PUNCHING SHEAR Punching shear is performed for columns and walls with an aspect ratio not exceeding 4. The outcome of stress check is shown graphically (Fig. 12-1). The value of stress check for each column is reported on the plan (Fig. 12-1) as well as in tables. Where required, the program provides punching shear reinforcement. 22

FIGURE 12-1 RESULTS OF PUNCHING SHEAR CHECK FOR COLUMNS 23