Pratt & Whitney. Power Systems MOBILEPAC. Gas Turbine Package. It s in our power.

Similar documents
Benefits. Reduced transportation time and cost. Limited on-site inventory. Minimal installation time. Efficient commissioning

5.2 MW Solar Mobile Power Unit

Organic Rankine Cycle Technology

STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017

MOBILE SUBSTATIONS TRAILER AND SKID. tgood.com. Energy, Fast!

Industrial Power. SGT-800 Gas Turbine. Power Generation: (ISO) 47.5 MW(e) / 50.5 MW(e) / energy

CAES2 2 nd Generation Compressed Air Energy Storage Technology Presented at SmartEnergy Canada Toronto, February 15, 2011

INdoor MGM 200 Natural Gas - emissions NOx < 500 5%O2. Type Specifications Co-generation Unit with MAN Gas Engine

Your partner for the right solution

Air Compressor Series.

RadiFit EC centrifugal fans. Compact, efficient, easily upgraded.

Development and performance analysis of a hybrid solar gas turbine. Lars-Uno Axelsson and Darsini Kathirgamanathan, OPRA Turbines, the Netherlands

TABLE OF CONTENTS Public Safety Building

ADDENDUM 2 - JULY 14, 2015

Community Clean Energy Resiliency Initiative PON-ENE BESS Request for Proposals Question and Answer Log

UC Davis - Facilities O&M Cogeneration Plant Bid Package October, 2007

Modular Concept of a Gas Turbine Power Plant

Sustainable use of Water and Energy. Produced Water Treatment and Recycling Power Generation from Waste Heat

2016 CDM Smith All Rights Reserved July 2016 SECTION MULTIPLE CONTRACT SUMMARY

PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES

Effluent Decontamination

ReliabilityFirst Regional Criteria 1. Verification and Data Reporting of Generator Gross and Net Reactive Power Capability

SPECIFICATIONS FOR SANBORN OILY WASTEWATER WASTE MINIMIZATION UNIT MODEL UFV750T

The H-25/H-15 Gas Turbine A Product of Hitachi Quality

C o u n t y o f F a i r f a x, V i r g i n i a

RC400G FC400G RESIDUAL CHLORINE ANALYZER RC400G NON-REAGENT FREE CHLORINE ANALYZER FC400G RESIDUAL CHLORINE ANALYZER

trusted innovative expertise

SECTION TEMPORARY FACILITIES AND CONTROLS

PROJECT SPECIFICATIONS

YANMAR s 35 kw Combined Heat and Power System.

Lubricated Rotary Screw Air Compressors. Constant Speed Drives and Variable Speed Drives kw hp

SECTION The specification section is organized by placing information in three standard parts:

Truly innovative oil-free compressed air technologies. DH Series. 15 kw 110 kw Oil-Less Rotary Screw Compressors

For Safe and Delicious Water

Largo & Allegro. Air Compressors. Largo & Allegro

August 31, Via efiling. Ms. Kimberly D. Bose, Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, D.C.

TDI TURBOTWIN Model T100-C

PM0011 CCGT Capital Cost Benchmark Study Final Report

Equipment Design. Detailed Plant Conceptual Design. Version 9.0

PLUMBING BUILDING SCOPE OF WORK

A SUBSTATION CONCEPT FOR CHANGEABLE LOAD CONDITIONS

FreezeFree TM Automated Anti-Icing System GENERAL SPECIFICATIONS

SPECIFICATIONS - DETAILED PROVISIONS Section Chlorination System (On-site Sodium Hypochlorite Generation System) C O N T E N T S

Using the PPM2 Portable Trace Moisture Transmitter

Texas Tech University Health Sciences Campus - MSBII Supplemental Bid Instructions March 3, 2017

SECTION PACKAGE BOOSTER PUMP STATIONS

RETROFIT SOLUTIONS. For Gas Turbines And Rotating Machinery

Equipment Design. Detailed Plant Conceptual Design. Version 7.0

NSF LARGE FACILITY WORKSHOP

Bid Package 22A Plumbing Systems

SCALING PEM ELECTROLYSIS TO 100MW HANNOVER MESSE APRIL 2017 SIMON BOURNE CTO

Annual sales - $16 Billion

Technical Specification Industrial Series - IS2 to IS48 Systems. CapDI Benefits. Feed Water Quality. Design and Scope of Supply.

Thai-German Technology Conference Biogas CHP Solutions / exhaust gas heat recovery - GTP Solutions GmbH (D) Bangkok, Hotel Crowne Plaza

Model 280. PureCycle. Power System. Emission-Free Energy from a Renewable Resource. Benefits

REMOTE TYPE HEAT/COOL BTU METER

Appendix J - Custom Uniformat for EDU Migration

Rollair. Air Compressors ROLLAIR 150E AND ROLLAIR 150V-180V-240V

DESIGN. DEVELOP. DELIVER. CAPABILITY STATEMENT

4MW Cogeneration Project. Unique Approach to Packaged Onsite Generation at

PureCycle 200 Heat-to-Electricity Power System

TOTEM. Cogeneration (CHP) Range. TECHNICAL SUBMITTAL TR r2. Highest total efficiency with modulating output and lowest NO X emissions available

ENVIROAIRE VS15 VS HP OIL-LESS SINGLE-STAGE VARIABLE SPEED ROTARY SCREW COMPRESSOR. EnviroAire VS Series

COMBINED CYCLE OPPORTUNITIES FOR SMALL GAS TURBINES

Schedule of Values Cruise Terminal 2 Expansion

Low Emissions gas turbine solutions

Union College Combined Cooling, Heat and Power Project

SIEA LUNGGA POWER STATION RETAINING WALL

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested.

Lubricated Rotary Screw Air Compressors kw 5 50 hp

City Of Mendota Construction Procedures

HISTORY AND COMMITMENT

Hachijo-jima Geothermal Power Plant

The H-25/H-15 Gas Turbine A Product of Hitachi Quality

WEBINAR #5: Best Practices for Wet Compression. Call In Number: or Access Code: #

LNG Technology Session & Panel General Electric Company - All rights reserved

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

PAULDING COLLEGE & CAREER ACADEMY

Hardwoods Gas Turbine Plant Life Extension Upgrades

GE EQUIPMENT CENTERS APPLICATION CONSIDERATIONS

A. Comply with governing regulations and rules/ recommendations of franchised utility companies, local ordinances, and regulations.

PACKAGED SYSTEMS INSTALLATION INSTRUCTIONS

COOLING TECHNOLOGY INSTITUTE

Town of East Haven Bid Fire Department Standby Generator Fire Department Station 4

CONSTRUCTION DOCUMENTS CHECKLIST for the 2012 Michigan Building Code Including Building Permit Application Checklist

MRI Chiller Installation Guidelines

12D SERIES THREE SCREW PUMPS ROTARY SCREW PUMPS

Kawasaki Gas Turbines-Americas Gas Turbines Power Generation Technology & Applications

TABLE OF CONTENTS. (Δ = Rev 11/15) Update #7

Section Safety Section Cleanup. None Required

PAHT C pumps ATEX PAHT C pump

Building Permit Application

The Renner Residence 2009 Mike and Elida Renner

Booster Pump Fundamentals. By: Bill Baglot

SECTION COOLING TOWER

THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS 345 E. 47th St., New York, N.Y

CONSTRUCTION REQUIREMENTS

STANDARD DRAWINGS. September 2013 UPDATED FEBRUARY 2016

TERMS SHEET For 240 Metric Ton-Per-Day Solid Waste Solution CREATING 6 MEGA WATTS OF ELECTRICITY PER HOUR

TERMS SHEET For 72 Metric Ton-Per-Day Solid Waste Solution CREATING 1.8 MEGA WATTS OF ELECTRICITY PER HOUR

Transcription:

Power Systems Pratt & Whitney Power Systems MOBILEPAC Gas Turbine Package TM It s in our power.

Pratt & Whitney FT8 MOBILEPAC Gas Turbine Package The MOBILEPAC gas turbine package requires the smallest footprint in the industry, utilizing as little as 25-foot by 60-foot space. Very little advance site preparation is required for the siting, and no foundation or concrete pad is necessary for installation of the unit. The unit is transportable by land, sea or air to anywhere in the world, allowing worldwide delivery of the MOBILEPAC gas turbine package within 24 hours. 25 MW of Mobile Power The MOBILEPAC gas turbine package was introduced more than 30 years ago with the FT4 engine. After many successful years of operation, the MOBILEPAC gas turbine package now utilizes the FT8 engine and offers 25 MW of moveable power. Utilizing the proven SWIFTPAC gas turbine package technology, this package is designed to provide quick, reliable power and is especially useful in emergency situations. The MOBILEPAC gas turbine package design includes two trailers. The first contains the gas turbine, electric generator, exhaust collector, diffuser and engine lube oil system. The second trailer carries the 15 kv switchgear, control system, operation panel, protective relays, batteries and charger, motor control center and the hydraulic start package. Compared to a typical 21-day installation and commissioning cycle for the SWIFTPAC gas turbine package, the MOBILEPAC gas turbine package can be driven to a site and begin generating power in less than one day. Pratt & Whitney. It s in our power. TM Benefits Ready for emergency power within one day (site ready) Environmentally compatible Dual fuel/dual frequency Optional black start capability Flexible trailer siting Highway compatible Three-point support and structural rigidity to maintain generator alignment Remote operation Leasing options available Product Facts Output (kw) 25000 Base engine FT8 # of Trailers 2 Installation 8 hours (site ready) Noise 95 dba at 1 meter NOx/CO 50/100 mg/m3 Grid 50 or 60 Hertz Fuel Liquid or Gas

Scope of Supply FT8-3 MOBILEPAC Gas Turbine Package Power Island Dual Fuel Water Injection Power Trailer Gas Turbine Package - Gas generator (GG8-3 core engine) - Power turbine - Diffuser - Collector box - Exhaust transition - Fabricated gas turbine base and mount assembly - Coupling connecting power turbine and generator Generator Package - Brush open ventilated; air-cooled synchronous generator or equivalent - Brushless exciter assembly - Stator heaters - Neutral ground transformer/resistor Control Trailer Control Enclosure with HVAC - Operator control cabinet - Monitoring cabinet - Instrument cabinet - Unit control cabinet Hydraulic Starting Package - Hydraulic starting motor - Ignition system - Off-line compressor internal water wash system - Lube oil system - Fuel supply system - Buffered air system - Water injection NOx control system - Current transformers - Stator RTDs - Vibration probes - Bearing drain RTDs - Bearing metal RTDs - Generator protective relay panel - Motor control center - Master terminal cabinet - Rack-mounted, sealed, lead, acid cell batteries - Gas turbine enclosure with three point jacking and leveling system - Two-stage inlet air filter with weather protection - Inlet silencing - Exhaust stack - Quick disconnect electrical interface - Hot and cold air RTDs - Rotor ground detection - Generator lube oil system - Enclosure - Quick disconnect electrical interface - Battery chargers - Switchgear module 15 kv class - CTG auxiliary transformer - FM200 fire suppression Field Installation Hardware - Interconnecting piping and hoses for - Hydraulic start - CO 2, fuel Options Available - Equipment erection - Equipment demolition - Interconnecting quick disconnect electrical cables for power and signal. - Access stairs and platforms for power trailer and control trailer - Balance of plant (BOP) design and supply - BOP design, supply, and install - Piping intefaces - Special maintenance tools - Freight Owner-Supplied Services and Responsibilities Project and Site Development - Adequate title and interest, permanent facility permits, construction permits and licensing - Equipment mounting and mounting hardware Engineering and Construction - Site engineering - Site Organization during construction - Emissions and acoustic testing - Worker's Compensation, employer's liability or any other local insurance required Other Responsibilities - Site survey/plot plan - Excavation for foundations, pipes, roads, cabling & grounding grid - Site leveling - Backfill - Finish grading Interface Requirements and Responsibilities - Natural gas for start-up, testing and operation 475 psig (33 bar), approximately 4700 scfm (2.2m3/sec) per gas turbine - Injection water for NOx control 5-50 psig (0.3-3.4 bar), approximately 25 gpm (115 L/min) per gas turbine - Potable water for gas turbine off-line water wash 50 psig (3.4 bar) min, approximately 300 gallons (1150 liters) per gas turbine water wash at 35 gpm (133 L/min) - Provisions of local communication facilities - Temporary construction staging & secure inventory area - Access road(s), interior roads and parking areas - All supervision and craft labor for complete off-loading, inventory, inventory control, storage, erection, installation, checkout, testing and start-up of all non-pwps supplied equipment and material - Consumable material for erection works - Surface drainage to and including any collection pond - Oily water separator - Sanitary waste disposal - Plant lighting - Plant fire protection systems-hydrants, panels and extinguishers - Liquid fuel for start-up testing and operation 30-75 psig (2.0-5.1 bar) approximately 36 gpm (136 L/min) per gas turbine - Electrical ground grid interconnections grounding pads are provided by PWPS on each trailer and aux skid - Vent and drain maximum flow on oily waste drain is 35 GPM for water wash. Total waste water per wash is 300 gal. - Site prep, leveling and compaction to meet at least 191,521 Pa (4000 lbs per square foot) compressive strength - Transmission system - Required test prior to startup - Construction equipment, tools and aids - Phasing and synchronizing the generator to purchaser s system - Intra-communication system - Site fencing and gates - Construction water - Builder's all risk insurance (BAR) - High-voltage power - Control system interface/grid signals - Alternate electrical power supply 255 kw per power island, 380V, 50 Hz, 3-phase for lighting, heating and intermittent auxiliaries

Typical Performance Gas Fuel 50 Hz Water Injected MOBILEPAC Gas Turbine Package 50Hz, 11.0kV, 09Pf Estimated Gross Power Output vs Ambient Temperature and Heat Rate vs Anbient Temperature FT8 MOBILEPAC Gas Turbine Package, Natural Gas, WI - 25 ppm NOx Sea Level, 60% RH, 63.5 mm W.C. Inlet Loss, 25.4 mm Exhaust Loss Est. Gross Power Output, MW per MP Ambient Temperature, Deg C 13,500 13,000 12,500 12,000 Heat Rate (kj/kw-hr) 11,500 11,000 10,500 10,000 9,500 9,000 8,500 Ambient Temperature, Deg C

General Arrangement Diagram FT8-3 MOBILEPAC Gas Turbine Package

Power Systems 400 Main Street East Hartford, CT 06108 www.pw.utc.com PS-S0018.01.10