Drop weight testing on sandwich panels with a novel thermoplastic core material

Similar documents
MECHANICAL CHARACTERIZATION OF SANDWICH STRUCTURE COMPRISED OF GLASS FIBER REINFORCED CORE: PART 1

BEHAVIOR OF FRP SANDWICH PANELS FOR TRANSPORTATION INFRASTRUCTURE

EXPERIMENTAL STUDY ON DOUBLE LAP JOINTS COMPOSED OF HYBRID CFRP/GFRP LAMINATE

FLEXURAL AND SHEAR STRENGTHENING OF REINFORCED CONCRETE STRUCTURES WITH NEAR SURFACE MOUNTED FRP RODS

Determining the Bond-Dependent Coefficient of Glass Fiber- Reinforced Polymer (GFRP) Bars

FRP Anchorage Systems for Infill Masonry Structures

Field and Laboratory Performance of FRP Bridge Panels

SEISMIC REHABILITATION OF REINFORCED CONCRETE BRIDGE COLUMNS IN MODERATE EARTHQUAKE REGIONS USING FRP COMPOSITES

CFRP STRENGTHENING OF CONCRETE BRIDGES WITH CURVED SOFFITS

FAILURE PREDICTION IN HONEYCOMB SANDWICH BEAMS UNDER LOW-VELOCITY IMPACT

SHEAR AND BUCKLING STRENGTHENING OF STEEL BRIDGE GIRDER USING SMALL-DIAMETER CFRP STRANDS

Vierendeel Steel Truss / Composite Skin Hull Test

Structural Behavior of Timber Aluminum Composite Beams Under Impact Loads. Samoel M. Saleh, Nabeel A. Jasim

DURABILITY PERFORMANCE OF EPOXY INJECTED REINFORCED CONCRETE BEAMS WITH AND WITHOUT FRP FABRICS

CHAPTER III DYNAMIC BEHAVIOR OF A LABORATORY SPECIMEN

Structural Performance of 8-inch NRG Concrete Masonry Units. Report Compiled for: Niagara Regional Group. Date: January 28, 2013

Mechanical Behaviour of Polymer Sandwich Composites under Compression

Mechanical Characterization of PU Based Sandwich Composites with Variation in Core Density

Improved Student Understanding of Materials and Structures through Non-Traditional Laboratory Project

Flexural strengthening of reinforced concrete beams using externally bonded FRP laminates prestressed with a new method

Page 1 of 46 Exam 1. Exam 1 Past Exam Problems without Solutions NAME: Given Formulae: Law of Cosines: C. Law of Sines:

Nafadi, Khalaf Alla, Lucier, Rizkalla, Zia and Klein BEHAVIOR AND DESIGN OF DIRECTLY LOADED LEDGES OF SHORT SPAN L- SHAPED BEAMS

Analysis and optimization of Composite Sandwich Structures using Optistruct

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

NEW COMPOSITE CONSTRUCTION OF HYBRID BEAMS COMBINING STEEL INVERTED T-SECTION AND RC FLANGE

FINITE ELEMENT ANALYSIS OF REINFORCED CONCRETE BRIDGE PIER COLUMNS SUBJECTED TO SEISMIS LOADING

Damage assessment of hollow core reinforced and prestressed concrete slabs subjected to blast loading

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS

Testing and Evaluation of CFS L-headers

EXPERIMENTAL INVESTIGATION OF WOOD NAILER TOP CHORD ATTACHMENTS FOR OPEN WEB STEEL JOISTS

CHAPTER III METHODS AND MATERIALS

THERMOPLASTIC COMPOSITE SANDWICH PANELS

Function-integrated GFRP sandwich roof structure Experimental validation of design

Disclaimer for FAA Research Publication

Exploratory Investigation of Failure Mechanisms in Transition Regions between Solid Laminates and X-cor Truss Sandwich

Effect of varying geometrical parameters of trapezoidal corrugated-core sandwich structure

Initial Tests of Kevlar Prestressed Timber Beams

Axial Load Behaviors of PSRC Composite Columns with Anchor-Type Transverse Reinforcements

ABC-UTC. Research Progress Report (Feasibility Study) Title: Alternative ABC Connections Utilizing UHPC. March, 2017

Deflection Assessment of an FRP-Reinforced Concrete Bridge. By Danielle K. Stone, Andrea Prota, and Antonio Nanni

Site Director: Dr. Sami Rizkalla Associate Director: Dr. Rudi Seracino Date: February 1 st, 2011

MECHANICAL PROPERTIES OF COMPOSITE SANDWICH STRUCTURES WITH CORE OR FACE SHEET DISCONTINUITIES

BEAMS: COMPOSITE BEAMS; STRESS CONCENTRATIONS

Level 6 Graduate Diploma in Engineering Structural analysis

Chapter 7. Finite Elements Model and Results

CHAPTER 3 EXPERIMENTAL INVESTIGATION

To have a clear idea about what really happened and to prevent the

Tests of R/C Beam-Column Joint with Variant Boundary Conditions and Irregular Details on Anchorage of Beam Bars

Behavior of Concrete/Cold Formed Steel Composite Beams: Experimental Development of a Novel Structural System

FE Review Mechanics of Materials

In-Plane and Out-of-Plane Performance of the MINI-MC Flange Connector

STRENGTH AND BEHAVIOR OF ELLIPTICAL STEEL TUBE BEAMS

Dynamic behavior of cellular materials under combined shear-compression

DEVELOPMENT OF STANDARD TEST METHODS FOR SANDWICH COMPOSITES UNDER ASTM COMMITTEE D30

Flexural Behaviour of Composite Girders Using FRP and Precast Ultra-High-Strength Fiber-Reinforced Concrete Slabs

CHARACTERIZATION OF STOCHASTIC HONEYCOMB SANDWICH FAILURE

Research, Development, Testing and Evaluation of Vehicle Anti-Ram Barriers: Tests of 100 kn (22 kip) BRUBelt Specimens

with Fillers Department of Civil Engineering, National Taipei University of Technology, Taiwan, R.O.C

Finite Elements Modeling and Analysis of Double Skin Composite Plates

MECHANICAL CHARACTERIZATION OF SANDWICH STRUCTURE COMPRISED OF GLASS FIBER REINFORCED CORE: PART 2

Marian A. GIZEJOWSKI Leslaw KWASNIEWSKI Wael SALAH

A STUDY ON RESIDUAL STRENGTH OF AL HONEYCOMB CORE SANDWICH COMPOSITE PANEL AFTER QUASI-STATIC INDENTATION DAMAGE

L Shaped End Anchors to Eliminate Premature Plate End Debonding in Strengthened RC Beams

DAMAGE TOLERANCE TEST METHOD DEVELOPMENT FOR SANDWICH COMPOSITES

ANALYSIS OF CARBON-FIBER COMPOSITE STRENGTHENING TECHNIQUE FOR REINFORCED BEAM

STRUCTURAL PERFORMANCE OF STEEL-CONCRETE-STEEL SANDWICH COMPOSITE BEAMS WITH CHANNEL STEEL CONNECTORS

Improvement of Mechanical Performance in Different Concrete Applications through Use of Steel Fibers

Seismic performance of New Steel Concrete Composite Beam-Columns

HYBRID COMPOSITE REPAIR for OFFSHORE RISERS

PRE-CONSTRUCTION INVESTIGATION FOR THE REHABILITATION OF A BRIDGE USING INTERNAL FRP TECHNOLOGIES

Finite Element Analysis on the Unloading Elastic Modulus of Aluminum Foams by Unit-cell Model

Interaction Testing Report. 24 SF Units with Synteen Geogrids. Stone Strong Systems Lincoln, Nebraska

TENSION TESTS OF HEADED STUD ANCHORAGES IN NARROW / THIN EDGE MEMBERS

Angle Cleat Base Connections

Methods of Making 3-Dimensional Shaped Composite Structures

Finite Element Analysis of RC Beams Strengthened with FRP Sheets under Bending

STRUCTURAL BEHAVIOUR OF SINGLY REINFORCED OPS BEAMS

Investigation of the Effect of Fiber Orientation on Mechanical Properties of Composite Laminate Using Numerical Analysis

CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS

The Flexural Properties of Glass Fabric/Epoxy -Rigid Polyurethane Foam Core Sandwich Composites at Different Span to Depth Ratios and Densities

Formulating Constitutive Stress-Strain Relations for Flexural Design of Ultra-High-Performance Fiber- Reinforced Concrete

Design of a Beam Structure for Failure Prevention at Critical Loading Conditions

Behavior of Reinforced Concrete Walls with Mesh Reinforcement Subjected to Cyclic Loading

AN INVESTIGATION OF SEISMIC RETROFIT OF COLUMNS IN BUILDINGS USING CONCRETE JACKET

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

Axial Compression Behavior of a New Type of Prefabricated Concrete Sandwich Wall Panel

GLASS FIBER-REINFORCED PLASTIC POLES FOR TRANSMISSION AND DISTRIBUTION LINES: AN EXPERIMENTAL INVESTIGATION

AN INNOVATIVE DUCTILE COMPOSITE FABRIC FOR STRENGTHENING CONCRETE STRUCTURES. Abstract

METHODS Of TESTING SANDWICH CONSTRUCTIONS AT ELEVATED TEMPERATURES. ( t I HIttIE'.. :1111( ,,e,r A pj... 4, STATE

Nonlinear Models of Reinforced and Post-tensioned Concrete Beams

Seliem, Lucier, Rizkalla, and Zia BEHAVIOR OF CONCRETE BRIDGE DECKS REINFORCED WITH HIGH- STRENGTH STEEL

SCIENCE & TECHNOLOGY

THE CFRP SAILPLANE WING SEGMENTS MANUFACTURED BY FILAMENT PLACEMENT

Erector Connector Meadow Burke Company In- Plane Performance

Influence of Arching Mechanism in Masonry Walls Strengthened with FRP Laminates

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

Development of High Performance Concrete Panels for Curtain Wall Systems. (818) ; FAX (818) ;

INFLUENCE OF PRSTRESS LEVEL ON SHEAR BEHAVIOR OF SEGMENTAL CONCRETE BEAMS WITH EXTERNAL TENDONS

An experimental study on the effect of concrete shrinkage on compressive behaviour of highstrength concrete-filled FRP tubes

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

Transcription:

University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Civil Engineering Faculty Publications Civil Engineering 2012 Drop weight testing on sandwich panels with a novel thermoplastic core material Christopher Y. Tuan University of Nebraska-Lincoln, ctuan@unomaha.edu Follow this and additional works at: http://digitalcommons.unl.edu/civilengfacpub Part of the Civil Engineering Commons Tuan, Christopher Y., "Drop weight testing on sandwich panels with a novel thermoplastic core material" (2012). Civil Engineering Faculty Publications. 44. http://digitalcommons.unl.edu/civilengfacpub/44 This Article is brought to you for free and open access by the Civil Engineering at DigitalCommons@University of Nebraska - Lincoln. It has been accepted for inclusion in Civil Engineering Faculty Publications by an authorized administrator of DigitalCommons@University of Nebraska - Lincoln.

Published in Journal of Sandwich Structures and Materials 14:3 (2012), pp. 325 338; doi: 10.1177/1099636212444748 Copyright 2012 Christopher Y. Tuan; published by Sage Publications. Used by permission. http://jsm.sagepub.com Drop weight testing on sandwich panels with a novel thermoplastic core material Christopher Y. Tuan Civil Engineering, University of Nebraska-Lincoln, Omaha, NE, USA Correspondence: Civil Engineering, University of Nebraska-Lincoln, Peter Kiewit Institute, 1110 South 67th Street, Omaha, NE 68182, USA; email ctuan@unomaha.edu Abstract A series of drop weight tests were conducted to evaluate the dynamic flatwise compression strength and flexural strength of sandwich panels with a novel core structure. This sandwich core material, known as Norcore, consists of interconnected cells in a unique configuration of truncated pyramid with sloping cell walls. Core materials made of thermoplastic including virgin Lexan, polycarbonate, polycarbonate regrind, high-impact polystyrene, and acrylonitrile butadiene styrene were tested. The test results showed that these sandwich panels have good strength as well as energy absorption capacities. Keywords: sandwich panels, impact loading, drop weight tests, energy absorption, thermoplastics Introduction Conventionally, sandwich panels are made up of two stiff and strong facings separated by a lightweight core. While aluminum and fiber-reinforced plastics are commonly used for the facings of sandwich construction, the core is generally made from monolithic materials in a repeated cell pattern. The development of lightweight, high-strength core materials has led to potential applications for blast resistance. For instance, these sandwich panels can be airlifted to forward bases where shelters or protective structures can be constructed expediently with 325

326 C. Y. T ua n in J ourn a l of Sandw i c h Structures and Mat e r i a l s 14 (2012) indigenous materials and labor. In this case, the strength/stiffness-to-weight ratio and impact energy absorption capacity are essential design parameters. Gibson and Ashby [1] provide detailed design guidelines for sandwich panels based on the failure modes including face yielding, face wrinkling, core failure, and delamination of facing from the core. In this paper, the dynamic strength of a novel sandwich panel structure due to the impact of a drop weight was studied in detail. The results are compared to the static test results published in the literature. The tests conducted are the ASTM C365 flatwise compressive strength and the ASTM D790 three-point loading flexural strength tests. The impact energy absorption capacities of several thermoplastic core materials are presented. Novel core cell structure A core material, known as Norcore [2], is manufactured by stretching a thin solid sheet of thermoplastic placed between two heated die plates. This core material has features of both a dense elastic solid and those of a foam-type material. This novel cellular structure is similar to a traditional honeycomb core and that of an egg crate. Due to the forming process used in creating this sandwich core material, it is possible to control the cell wall thickness and relative density associated with cellular structure configurations. Figure 1(a) and (b) shows the top view and the edge view of a typical Norcore panel, respectively. Tuan and Sierakowski [3] studied the unique cell geometry of Norcore and compared finite element simulation results with test data. The fabrication process of these core panels is shown in Figure 2. The vents are used to create a vacuum between the plates. The cell structure of the core resulting from this process is a series of interconnected truncated cones. These cores have variable cell thickness, strength, and stiffness, the selection of which is dependent upon a particular application. The stretched core thus formed has a stiffness of 50 to 100 times that of the original extruded sheet, and with the addition of facings, the resultant sandwich construction may have a stiffness of 300 to 1000 times that of the original extruded sheet. Some of the physical and mechanical properties of these sandwich panels with aluminum facings from the manufacturer are given in Table 1. Drop weight tests Drop weight testing facility A drop weight testing facility is set up in the Structural Research Laboratory at the Peter Kiewit Institute, Omaha, Nebraska. The setup was designed to deliver impulsive loading onto a test specimen. As shown in Figure 3, the facility is composed of a strong foundation, steel supports, a strong wall, a PVC pipe drop chute, and a drop weight.

D ro p weight testing on sandw ich pa nels with thermoplastic core mat e r i a l 327 Figure 1. Cell structure of Norcore. (a) Top View (b) Edge View. The steel supports are firmly fixed to the foundation. The drop weight is made of a 5.625-in. (143mm) diameter steel cylinder and a 1.5-in. (38 mm) steel rod welded to the end for impact tup. The cylinder had four skids welded at equidistance along the surface as stabilizers in the PVC drop chute. One-inch (25 mm) holes are drilled along the PVC pipe at 2-, 3-, 4-, and 5-ft (0.6, 0.9, 1.2, and 1.5 m) drop heights. The total weight of the drop weight is 72.3 pounds (321.6 N). The drop weight is lowered into the drop chute at a drop height by means of a rope going over a pulley. The drop weight can be quickly released by detaching the rope from the anchor on the concrete floor. The drop weight tests conducted were the flatwise compressive strength and three-point simple beam flexural strength tests. The specimens used for the flatwise compressive strength drop weight tests

328 C. Y. T ua n in J ourn a l of Sandw i c h Structures and Mat e r i a l s 14 (2012) Figure 2. Fabrication process of Norcore. Table 1. Mechanical properties of 1-in. Norcore core with 0.023-in. aluminum facings Property ASTM test Units HIPS PC ABS Flexural strength a D790 Psi 343 587 Flexural strength D790 Psi 1146 1538 1897 Flexural modulus D790 Psi 317,000 210,000 431,000 Shear strength C393 Psi 105 142 170 Shear modulus C393 Psi 5000 3100 7000 Flatwise compressive Ultimate load C365 Lb 3990 2620 Strength C365 Psi 250 164 Edgewise compressive Strength a C364 Psi 167 199 Strength C364 Psi 16,200 14,270 ABS: acrylonitrile butadiene styrene; HIPS: high-impact polystyrene; PC: polycarbonate; 1 in.= 25.4 mm; 1 psi = 6.9 kpa; and 1 lb = 4.45 N. a. Test data without facings. were 1-in. (25 mm) or 1.5-in. (38 mm) thick, 4 in. by 4 in. (102mm 102 mm) square panels without facings, and those for the bending tests are 12 in. (305 mm) long and 4 in. (102mm) wide core with 0.032-in. (0.81 mm) aluminum facings. These test specimens were supplied by the manufacturer.

D ro p weight testing on sandw ich pa nels with thermoplastic core mat e r i a l 329 Figure 3. Drop weight testing setup. Figure 4. Flatwise compression test setup.

330 C. Y. T ua n in J ourn a l of Sandw i c h Structures and Mat e r i a l s 14 (2012) Figure 5. (a) 1.5-in. thick polycarbonate (PC); (b) 1-in. thick PC-regrind (PCR); (c) 1.5-in. thick acrylonitrile butadiene styrene (ABS); (d) 1-in. thick ABS; (e) 1.5-in. thick high-impact polystyrene (HIPS); and (f) 1-in. thick HIPS.

D ro p weight testing on sandw ich pa nels with thermoplastic core mat e r i a l 331 Table 2. Flatwise compression drop weight test results Core Drop Peak Impact Energy Energy height height stress energy absorption absorption Core material (in.) (in.) (psi) (in.-lbs) (in.-lbs) (%) Polycarbonate (PC) 1.5 24 240 1735 1045 60 Polycarbonate (PC) 1.5 24 233 1735 994 57 Polystyrene (HIPS) 1.5 20 461 1446 980 68 Polystyrene (HIPS) 1.5 20 446 1446 934 65 Polystyrene (HIPS) 1.5 20 398 1446 1002 69 Polystyrene (HIPS) 1.5 20 415 1446 1090 75 Polystyrene (HIPS) 1.5 20 487 1446 1091 75 ABS 1.5 20 601 1446 1260 87 ABS 1.5 20 498 1446 1040 72 ABS 1.5 20 556 1446 1330 92 ABS 1.5 20 546 1446 1358 94 ABS 1.5 20 549 1446 751 52 PC-regrind 1.5 20 233 1446 1370 95 PC-regrind 1 22 265 1591 1143 72 PC-regrind 1 22 232 1591 1012 64 PC-regrind 1 22 250 1591 1091 69 PC-regrind 1 22 264 1591 1169 73 PC-regrind 1 22 196 1591 924 58 Polystyrene (HIPS) 1 22 149 1591 702 44 Polystyrene (HIPS) 1 22 124 1591 636 40 Polystyrene (HIPS) 1 22 155 1591 887 56 Polystyrene (HIPS) 1 22 109 1591 588 37 Polystyrene (HIPS) 1 22 96 1591 572 36 ABS 1 22 227 1591 968 61 ABS 1 22 242 1591 1065 67 ABS 1 22 262 1591 929 58 ABS 1 22 280 1591 1125 71 ABS 1 22 236 1591 1016 64 ABS: acrylonitrile butadiene styrene; HIPS: high-impact polystyrene; 1 in.= 25.4 mm; 1 psi = 6.9 kpa; and 1 in-lb = 0.113 J. Flatwise compression tests A compression test specimen placed between two rigid steel plates is shown in Figure 4. The total downward force during a drop weight test was monitored by a 200- kip (890 kn) load cell. Two linear variable differential transformers (LVDTs) were

332 C. Y. T ua n in J ourn a l of Sandw i c h Structures and Mat e r i a l s 14 (2012) Figure 6. Failed high-impact polystyrene (HIPS) core under flatwise compression. used to measure the relative displacement between the two steel plates. The average displacement is taken as the contraction in the core material. Strain gages were also mounted on the webs of some specimens to estimate the strain rate of the drop weight impact loading. C-clamps were used to snugly hold the top steel plate to prevent it from rebounding after impact. The strain, displacement, and force data traces were recorded by a data acquisition system at a sampling frequency of 4000 Hz. Figure 5(a) through (f) shows the load-deflection curves of different Norcore materials from the flatwise compression drop weight tests. The area under a load-deflection curve represents the capacity of impact energy absorption of the core material. The initial energy of the drop weight before impact, calculated as the drop weight times drop height, and the energy absorption capacities are presented in Table 2. A failed 1.5-in. (38 mm) thick, high-impact polystyrene (HIPS) core is shown in Figure 6. One 1.5-in. HIPS and one 1.5-in. acrylonitrile butadiene styrene (ABS) specimens had a strain gage mounted vertically on the web to measure the strain rate. The strain rate appeared to be dependent upon the stiffness of the core materials. As shown in Figure 7, the peak strain rate in the ABS was about 11/sec at 0.002 sec and that in HIPS was about 3/sec at 0.003 sec after impact. Three-point bending tests All the sandwich panel specimens under bending drop weight tests were 12 in. (305mm) long and 4 in. (102mm) wide core with 0.032-in. (0.81 mm) aluminum facings. The clear span between the simple supports was 9 in. (229 mm). The 1.5- in. (38 mm) overhang at each end of the specimen was free to rotate. The test specimens were impacted at the mid-span by the drop weight. Two strain gages were mounted on the top facing at 2-in. (51 mm) distance on either side of the mid-span, and two strain gages were mounted on the bottom facing at the midspan. The displacement at the mid-span is monitored by a string potentiometer. Some specimens had additional strain gages mounted on the web at the mid-

D ro p weight testing on sandw ich pa nels with thermoplastic core mat e r i a l 333 Figure 7. Strain rate of the flatwise compression drop weight tests. Figure 8. Drop weight bending test setup. span to monitor the strain rate. Figure 8(a) shows a specimen before impact of the drop weight and Figure 8(b) shows the specimen after the impact. Most common failure modes under a three-point bending test are local buckling or wrinkling in the top face, local yielding in the bottom face, crushing of

334 C. Y. T ua n in J ourn a l of Sandw i c h Structures and Mat e r i a l s 14 (2012) Figure 9. Failure modes observed in the flexural test. Figure 10. Load-deflection curves. the core material, and bond failure between facing and the core, as shown in Figure 9. The sandwich panels had 1.5-in. thick core made of polycarbonate, HIPS, ABS, and virgin Lexan. The load-deflection curves obtained from the drop weight

D ro p weight testing on sandw ich pa nels with thermoplastic core mat e r i a l 335 Figure 11. Tensile strains in the bottom face at mid-span. bending tests are compiled in Figure 10. The string potentiometer malfunctioned during the test of HIPS panel. It is evident that all the sandwich panels had fairly good strength and ductility for impact loading. The maximum mid-span deflection sustained was generally about 2 in., taking place within 0.02 0.03 sec after impact. The undulations in the impact force (or support reactions) were probably due to oscillations of the beam after making contact with the drop weight. Aluminum has an elastic modulus of 10_106 psi (69 GPa) and a yield point of 30 35 ksi (207 241 MPa). The tensile strains in the bottom face obtained are presented in Figure 11, where the bottom face yielded when the tensile strains reached about 3500 micro strains. The compressive strains in the top face obtained are presented in Figure 12, where local wrinkling occurred in the face when the compressive stresses reached about 4 ksi (28 MPa). The strain rate of the drop weight bending tests can be estimated from the strain gages mounted vertically on the web of the sandwich core at the mid-span. The compressive strains thus obtained are presented in Figure 13. The strain rates obtained from the bending tests are remarkably close to those obtained in the flat-

336 C. Y. T ua n in J ourn a l of Sandw i c h Structures and Mat e r i a l s 14 (2012) Figure 12. Compressive strains in the top face. wise compression tests. The peak strain rate in the HIPS and Lexan was about 11/sec at 0.002 sec and that in PC was about 8/sec at 0.001 sec after impact. Discussions Sierakowski and Hughes [4] conducted a series of static flatwise compression and beam-bending tests on the sandwich panels with the Norcore materials. They also reported the results from dynamic compressive tests by using a Split Hopkinson Pressure Bar (SHPB). The average values from the drop weight tests are compared with their test results in Table 3. The flatwise compression drop weight test results compare fairly well with the SHPB test data, while the static test results are much higher in many cases. This could be due to early buckling of the web upon initial high-impact stress (see Figure 6), while the instability is delayed under static loading. On the contrary, the static bending test results [4] are lower than the drop weight test results and the published data by the manufacturer [2].

D ro p weight testing on sandw ich pa nels with thermoplastic core mat e r i a l 337 Figure 13. Compressive strains in the core web. Table 3. Comparisons of drop weight test results vs. static test results [4]. Flatwise compression tests (psi) Beam Bending Tests (lbs) Core Drop Drop Core material height (in.) weight Static [4] SHPB weight Static [4] Static [2] Polycarbonate (PC) 1.5 235 143 348 1745 448 1538 PC-regrind 1 241 418 235 501 PC-regrind 1.5 233 439 235 1103 Polystyrene (HIPS) 1 127 658 690 655 1146 Polystyrene (HIPS) 1.5 441 473 493 462 ABS 1 249 605 410 726 1897 ABS 1.5 550 815 484 1653 ABS: acrylonitrile butadiene styrene; HIPS: high-impact polystyrene; SHPB: Split Hopkinson Pressure Bar; 1 in.= 25.4 mm; 1 psi = 6.9 kpa; and 1 lb = 4.45 N.

338 C. Y. T ua n in J ourn a l of Sandw i c h Structures and Mat e r i a l s 14 (2012) Conclusion The dynamic strength of a novel sandwich panel structure due to the impact of a drop weight was studied in detail. The results are compared to the static test results published in the literature. The drop weight tests were conducted in accordance with the ASTM C365 flatwise compressive strength and the ASTM D790 three-point loading flexural strength tests. The initial impact energy of the drop weight and the impact energy absorption capacities of several thermoplastic core materials are presented. The percentage energy absorption shows that, for the same core material, the 1.5 in. (38mm) core absorbed more impact energy than the 1-in. (25 mm) core did. The test results have shown that these sandwich panels have good strength as well as good energy absorption capacities. The drop weight tests are easy to conduct and the tests are repeatable and reliable. Further drop weight testing should be conducted on sandwich panels with conventional core construction to compare impact energy absorption and weight savings characteristics against those of the Norcore panels. Acknowledgment The author wishes to thank Jeffrey Svatora and Kelvin Lein for their timely assistance in setting up the drop weight tests and the effort in acquiring data. References 1. Gibson LJ and Ashby MF. Cellular solids. Oxford, UK: Pergamon Press, 1988. 2. Norfield Corporation. Technical data package. Danbury, CT: Norfield Corporation, 1995. 3. Tuan CY and Sierakowski RL. Numerical analysis of a novel thermoplastic sandwich core material. J Sandwich Struct Mater 2000; 2(3): 215 224. 4. Sierakowski RL and Hughes ML. Force protection using composite sandwich structures. Compos Sci Technol 2006; 66: 2500 2505.