YOUR LITE-DECK SECTIONS

Similar documents
Before You Get Started, You Will Need

Issue Date: April 2003 Release: I. Product Specifications

A-ONE Insulated Forms Installation Manual

Important: Before You Start

Polycrete Big Block Standard Specification

High Performance Insulating Concrete Form

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

TECHNICAL EVALUATION REPORT No. 27/2008/2060

Stone and Masonry Veneer

Chapter 13 - Finish Framing

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

CONCRETE WORK CONCRETE WORK. Underground Electric Distribution Standards I. SCOPE APPLICABLE STANDARDS

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

POST FRAME BUILDING STANDARDS

2.15 CONCRETE PLACEMENT

Building Division Informational Handout

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

SECTION CONCRETE FORMWORK AND ACCESSORIES

(800) (562) A Subsidiary of the International Code Council

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

PS 3000 Installation Manual Step-By-Step Procedures C.9. DOOR AND WINDOW OPENINGS C.9.1 PREPARE IN ADVANCE. C.9.2 VBUCK CONSTRUCTION.

INSTALLATION CHECKLIST 2 ND EDITION. Fox Blocks Abbott Drive Omaha, NE

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

Statement of Special Inspections 2013 CBC

DIVISION 03 CONCRETE SPECIFICATION : FORMS AND FORMWORK

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

MID-RISE DESIGN & CONSTRUCTION

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: DIVERSIFOAM PRODUCTS EVALUATION SUBJECT:

U.S. EDITION RESIDENTIAL CONSTRUCTION DETAILS SAMPLE. A visual guide to construction detailing. Emma Walshaw

General Installation Overview

Module number 3 provides an on-line, self-paced training seminar on chapter 4, foundations and chapter 5, floors from the residential code of ohio.

Superior strength, flexibility, safety and value.

I.C.E. BLOCK (U.S. Patent No. 4,223,501) Detail Manual

REINFORCED CONCRETE MASONRY SECTION

ITEM 6 CONCRETE CURBS, GUTTERS, AND SIDEWALKS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA (831) FAX: (831)

DECK PERMIT APPLICATION

MATERIALS AND TOOLS. Construction Guidelines. InterBlock

1. Cast-in-place concrete is specified in Section

HOTEL SPECIFICATION SECTION 08100

PART 1 GENERAL RELATED SECTIONS A. Section 03200: Concrete Reinforcement. B. Section 03300: Cast-In-Place Concrete.

Health & Safety Policy and Procedures Manual SECTION 23 MASONRY CONSTRUCTION

Installation Guide and Safety Manual QuietClip (Resilient Sound Isolation Clips)

Below-grade pours (such as foundations) can be done out of the chute of the concrete truck or conveyer, however using a pump is best.

Lintel Tables Design Notes and Limitations

Installation Guide and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

Safety Documents > Safety Manual > Scaffolds

Reliant Holdings Ltd Safety Management System

Installation Guide and Safety Manual

KEVIN JATON. Deck Designer Specification Kit. All rights reserved copyright 2017 DIY Technologies. Page 1

GARAGE MAIN FLOOR PLAN

Recessed Door Header Engineering PSBox8LT(5-5/8") 22ga.

SPECIAL INSPECTION AGREEMENT

Insulated Concrete Forms (ICFs)

NUDURA FIELD GUIDE CHECKLIST & PROJECT LOG

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

SECTION CAST-IN-PLACE CONCRETE

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

3M CS-195+ Composite Sheet Product Description

SECTION INSULATING CONCRETE FORMING (ICF)

Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips)

POST AND FRAME STRUCTURES (Pole Barns)

DIVISION: CONCRETE SECTION: SPECIALTY PLACED CONCRETE REPORT HOLDER: EMMEDUE S.P.A.

Part 1: Vocabulary Select the best answer and write the corresponding letter in the space provided.

CONSTRUCTION IMPORTANT TERMS AND FACTS CHAPTER 15

Estimating Guide For Concrete Tilt-up Wall Using

ENTRY FORM. DVASE 2014 Excellence in Structural Engineering Awards Program

Interior Hangers. Application

SECTION INSULATING CONCRETE FORMING (ICF)

BUILDING PERMIT APPLICATION DECK. Address: City: Postal Code: Address: City: Postal Code: Address: City: Postal Code: Deck Size Construction Value $

BUILDING PERMIT REQUIREMENTS FOR: RESIDENTIAL DECKS CITY OF ESCONDIDO BUILDING DIVISION 201 N. BROADWAY, ESCONDIDO, CA (760)

POST AND FRAME STRUCTURES (Pole Barns)

assembly an open space between the roof and ceiling of a building attic balloon frame a joist constructed of steel with bars in the verticle web space

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

A. AISI Specifications for Design of Cold-Formed Steel Structural Members

Installation GUIDE STEEL DECKING SOLUTIONS FOR CONCRETE SLABS

Building Design Data

PRESENTATION PLAN A MODEL COMPARISON FLOOR CONSTRUCTION

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

Project Address: Name of Person Completing Form:

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

Mechanical Engineer of Record: (Smoke Control Systems Only) Name & License Company. Others: Responsible Party Name & License Company

Building with Insul-Deck Floor & Roof System

2012 VIRGINIA TECH SCHEDULE OF SPECIAL INSPECTIONS

ESR-1812 Reissued October 1, 2012 This report is subject to renewal November 1, 2013.

Andy Schreder CBO Building Official for St Francis, Nowthen

Armopanel Concrete Wall System. Design Guide B-3.1. BASEMENT WALLS

Statement of Special Inspection Requirements

Structural Design Engineers 120 Montgomery Street, Suite 1410 San Francisco, California / Fax 415/

SECTION SOUND ISOLATION

What s Gray, Gets Hard, and Holds Up Your Home?

CONCRETE & MASONRY SAFETY

Table of Contents NOTE:

Open-Web Truss Long Span Installation Guidelines

SECTION CHAIN LINK FENCES AND GATES (PARK)

Transcription:

General Information Warning - Serious injury or death may result from safety hazards caused by improper use or installation. When in doubt about proper use or installation of Lite-Deck, immediately contact your project s Structural Engineer or your Lite-Deck supplier for clarification. Before beginning, check local engineering and building codes on cast-inplace, joisted concrete construction. The instructions in this manual cover basic building situations and are not meant to replace job-specific codes for the engineering or safety for a specific project. The Lite-Deck system described in this manual requires appropriate bracing and shoring to properly support the form work during the placement of concrete. This manual covers basic bracing and shoring and is not meant to replace job-specific requirements. Installer is responsible for the design and correct installation of shoring of Lite-Deck forms in accordance with ACI (American Concrete Institute) 347R-94 Guide to Formwork for Concrete - Chapter 2, Design. Any variance from these standards must be provided and certified in advance by a structural engineer, licensed for the jobsite location, type and specifications. The Lite-Deck system described in this manual requires appropriate steel reinfocing to properly support the dead loads, live loads and clearspans required. This manual covers basic reinforcing and is not meant to replace job-specific requirements. Installer is responsible for placement of all reinforcing steel in accordance with ACI (American Concrete Institute) 318-99 Building Code Requirements for Reinforced Concrete. Any variance from these standards must be provided and certified in advance by a Structural Engineer, licensed for the jobsite location, type and specifications. Changes and Revisions - Lite-Form International reserves the right to change product design, safe working loads, product dimensions or installation techniques at any time without prior notice to users. Interchangeability - The Lite-Deck forms and the placed concrete will, in most cases, require the application of a finish or cover material which is not manufactured or supplied by Lite- Form International. Installers are instructed to follow the manufacturer s recommendations for the proper use of those products and/or systems in conjunction with Lite-Deck. Although certain types of finishes and covers are mentioned in this manual, Lite- Form International does not recommend or endorse any particular finishing material or system. Warranty - Lite-Form International, the company will refund the price of or replace, at it s election, any Lite-Deck component which it finds to be defective provided the product has been used properly. Except as expressly stated above, the Company makes no warranty of fitness for any particular purpose nor does it make any warranty, expressed or implied, of any nature whatsoever with respect to the product or the use thereof, by the way of illustration and example. In no event shall the Company be liable for delays caused by defects, for loss of use or for indirect, special or consequential damages, or for any charges or expenses of any nature incurred without its written consent. The foregoing is the full extent of the responsibility of the Company even though the Company may have been negligent Manufactured & Distributed under license by: Lite-Form International - 1950 W. 29th St. - South Sioux City, NE 68776 - Phone Toll Free in North America: 1-800-551-3313 YOUR LITE-DECK SECTIONS - Compare the joists depths and lengths of your Lite-Deck sections with your order. Sections are normally supplied in custom lengths and require no field cutting. If sections must be trimmed or cut, this can be done with a reciprocating saw. CAUTION! Lite-Deck is to be used with wall systems which are capable of supporting the weight of solid concrete floors, decks and/or roofs. Lite-Deck is normally used in conjunction with conventional or insulated concrete walls and concrete block walls. A licensed Structural Engineer or your local building code office can confirm whether the structure s walls are appropriate. MATERIALS AND TOOLS YOU NEED - Good quality 2x4 and 2x6 dimensional lumber - Lengths of 1 1/2 steel punch bar - Approved shoring system (2 examples are illustrated) - Various screws as detailed in manual - 16 gauge wire This manual or parts thereof may not be reproduced in any form without written permission from Lite-Form International. Copyright 2002 Lite-Form International Lite-Deck sections are being placed on top of a solid, insulated concrete basement. The interior perimeter bracing and shoring (perpendicular to the clear span) has been placed. Note the vertical reinforcing steel which has been cast into the basement walls. That steel will be structurally integrated into reinforcing steel used for the Lite-Deck floor.

INSTALL INTERIOR PERIMETER BRACING Interior Perimeter bracing is placed horizontally at the top of the interior sides of the walls, on both ends of the Lite-Deck sections, perpendicular to the Lite-Deck steel C channels. DIAGRAM A and DIAGRAM B. - Attach lengths of 1.5 steel punch bar to 2x4 wood stud, using 1 1/4 long pan head screws, placed approx. 16 apart. - Place bracing flush with top of wall. continuously on both ends. Anchor wood stud to wall, every 16 to 24 with masonary screws or nails when anchoring to masonry walls. Use drywall screws when anchoring to an insulating concrete form s furring strips or pads. -Reinforce the brace by installing good quality 2x4 wood studs vertically, every 4 to 6. Vertical studs will carry the weight of concrete placement! So, it must be securely anchored to the wall approx. 3 apart and toenailed to horizontal brace at top. - Vertical studs must be resting on solid, spreader footing or concrete pad. -Any span farther than 8 feet must have temporary shoring supporting it - Adjust shoring height to compensate for any required camber DIAGRAM A Interior Perimeter Bracing Steel Punch Bar Lite-Deck Sections will go here Horiz. 2x4 wood brace Top of wall DIAGRAM B AND C ARE LOCATED AT THE END OF THIS DOCUMENT... Vert. 2x4 brace every 4 to 6 Punch bar screwed to 2x4 every 16 When Lite-Deck is placed, punch bar is attached to C channel, every 24 2x4 attached to wall every 16 to 24 Vert. brace is attached to wall every 3 and toenailed into horiz. brace at top 2x4 must be on solid, spread footing or concrete pad INSTALL TEMPORARY SHORING Temporary shoring is used to carry the majority of the weight, as concrete is placed. It must be placed in accordance with a licensed Structural Engineers job-specific guideline or in accordance with ACI (American Concrete Institute) 347R-94 guide to formwork for Concrete - Chapter 2, Design. Continous shoring is placed perpendicular to the Lite-Deck sections and spaced 6-8 feet apart. Adjustable, pre-rated shoring systems are strongly recommended and can be purchased or rented, as needed. If nonrated shoring materials are used, a Structural Engineer can provide guidance on the load bearing capacities of various shoring materials. Two types of shoring techniques are illustrated. DIAGRAM B and DIAGRAM C. PLACE LITE-DECK SECTIONS With bracing and shoring in place, sections can be placed snugly together. DIAGRAM B. - Anchor steel punch bar to Lite-Deck steel C channels with 1 1/4 self-tapping pan head screws every 24 Caution! In windy conditions, it may be necessary to weight the sections Caution! Do not step onto the joist portion of sections Caution! Workers should not be under sections while they are being placed.

- Shoring must be on solid, spreader footing or concrete pad - If permanent joists will be supporting Lite-Deck sections, they must be designed by structural engineer, to support the combined dead and live loads. INSTALL REINFORCING STEEL - Reinforcing steel (rebar) must be placed in accordance with a licensed Structural Engineer s job-specific guideline or in accordance with current ACI (American Concrete Institute) 318-99 Building Code Requirements for Reinforces Concrete. Rebar is normally placed in the joist cavity, at the perimeter and within the concrete cover. The rebar shown in this manual is not intended to be a structural engineering guideline for actual placement DIAGRAM D. - Prior to placing the rebar. mesh or in-floor heating in the concrete cover, the outer perimeter bracing should be completed. Workers should not be under sections while rebar is being placed DIAGRAM B AND C ARE LOCATED AT THE END OF THIS DOCUMENT... Above: This shoring combines adjustable, load-rated shoring posts with engineered wood trusses. Note that the end of the trusses are supported with 2-inch dimensional lumber which has been anchored into the basement s solid concrete wall. INSTALL OUTER PERIMETER BRACING Outer bracing is installed to contain the concrete during placement. The bracing material can be rigid plystyrene or dimensional lumber. The rebar and wire techniques for holding it in proper alignment is illustrated. However, your Structural Engineer or Lite- Deck supplier may suggest other anchoring systems. DIAGRAM D and DIAGRAM E. - The 2x4 outer rail is used to keep bracing in proper alignment - Install anchors using 20 lengths of #4 rebar and 16-guage wire. - Anchors are placed approx. 6 back from edge of Lite-Deck sections - Place anchors 4 apart, on all sides INSTALL UTILITY BLOCKOUTS, ETC. - Blockouts for utility openings in the finished floor/deck, can be placed prior to concrete placement. - Caution! Blockouts must be placed between concrete joists - Avoid placing blockouts over steel C channel - Caution! Workers should not be under sections while blockouts are being placed. INSTALL MESH AND IN-FLOOR HEATING SYSTEM FOR CONCRETE COVER - Once the outer perimeter bracing has been secured, reinforcing mesh or rebar can be placed for the concrete cover. Follow the guidelines provided by your licensed Structural Engineer or install in accordance with ACI Standards mentioned in this manual. If systems such as in-floor heating are to be installed, follow the manufacturer s guidelines for proper installation.

DIAGRAM D Outer Perimeter Bracing for Insulating Concrete Form Walls 20 length of #4 rebar 2 x2 x20 rebar channel cut with hot knife or router 16-guage wire is twisted as needed, for maximum tension DIAGRAM E Outer Perimeter Bracing for Conventional Masonary Walls 2x4 outer rail, continous STYLE I: ICF wall insulation is extended to full height of Lite-Deck cover 2 dimen. lumber anchored to masonary wall every 24 STYLE II: Rigid insulation planks are attached with wood cleats, using drywall screws and insulation washers. Place cleats approx. 24 apart. Expandable foam can assist when placing this outer piece of foam. REINFORCING STEEL PLACEMENT Lite-Deck is designed to produce Structural Reinforced Concrete which is adequate for the project specifications. Steel reinforcing must conform to current ACI (American Concrete Institute) Codes 318 and 614 and CRSI (Concrete Reinforcing Steel Institute) standards. Any variations from these standards should be done under the direction of a licensed Structural Engineer or local building code official. CONCRETE PLACEMENT The following concrete specifications are only suggestions. Specifications from your licensed Structural Engineer or local building code office should be followed, if they are different: - Start by placing concrete in the joists - Concrete can be placed with pump, out of truck or with wheelbarrow** -Avoid excessive concentrations of crew or piles of concrete - Typical concrete specifications: 4-6 inch slump 4,00 to 5,000 psi 1/2 to 3/4 inch smooth aggregate - Must be finished at time of placement...manually or with power float - Should be consolidated by vibrating Concrete placement must be in accord with ACI (American Concrete Institute) codes 305 and 306 (hot and cold weather weather placement) and code 301 for structural concrete. **Supplier must be able to provide concrete in a timely manner and plans must be made for an alternate method of concrete placement in the event of equipment failure. Concrete must be placed in a single operation. Any cold joints in joists or cover could result in structural failure of the installation. REMOVING BRACES - Wait a minimum of 21 days or until concrete has reached 75% of design strength (through hydration) before removing temporary shoring or bracing. A simple cylinder test can be done by a local testing facility to determine the design strength at any time. CAUTION! WORKERS MUST NOT BE UNDER SECTIONS WHILE CONCRETE IS BEING PLACED! Workers should observe placement from a safe distance. If shoring/bracing shifts or fails, placement can be immediately stopped. Manufactured and Distributed under license by Lite-Form International 1950 W. 29th St. - South Sioux City, NE 68776 For personalized technical assistance, contact your PolySteel Distributor or call: 800-977-3676.

DIAGRAM B Temporary Shoring using adjustable, load-rated system Diagrams in this manual do not show complete and proper reinforcing steel (rebar) placement. Project-specific engineering plans or local building codes must be followed Interior Perimeter Bracing The system s shoring rail is attached to C channel every 24 Cast -in-place Insulating Concrete Form wall Vertical 2x4 support for interior of Perimeter Bracing Adjustable, load-rated shoring system is placed every 6 to 8 Shoring must be on solid, spread footing or concrete pad DIAGRAM C Temporary Shoring with Floor Joists & Dimensional Lumber 2x6 Top Rail attached to C channel every 24 2 Floor Joists anchored together & to Top Rail 4x4 wood member every 4 Wood 1x4 stabalizer every 8 is anchored to bottom of Joists