Florida Department of Transportation

Similar documents
BAYBLOCK HT/BAYBLOCK HT BASE

838 Coatings System Specification Single-Ply Restoration (838 SPR)

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY

SMOOTH SURFACED BUILT-UP ROOFS WITH ARC SEBS REFLECTIVE ROOF COATINGS

Section Energy Star & LEED Compliant SPF Roof System Roof System with Acrylic Coating, Aggregate & Cementitious Traffic Topping

Technical Data Sheet NUKOTE SIL HS DESCRIPTION:

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets

Thermoplastic Single Ply & Multi-Ply Roofing Systems

3,Rothwell Street, Timaru, South Canterbury. ; : Phone or

Henry #1 CHOICE OF PROFESSIONALS

FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets

SOLAR COATING SYSTEMS ACRYLIC RENOVATION ROOF 4.5. Specification for Built-Up Roofing SUMMARY

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL

ACRYLIC-URETHANE ROOF COATING SYSTEMS SOPREMA

"WE CAN AGUASEAL THAT" AGUASEAL WATERPROOFING SYSTEMS A G U A B A S E

Section Fluid-Applied Roofing. Modified Bitumen Roof Preservation System Master Guide Specification

DOWSIL ALLGUARD Silicone Elastomeric Coating

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WARRANTY ON CONCRETE SURFACE COATING

COOL BARRIER ROOF. High Solar Reflective Elastomeric Liquid Applied Roof Coating Water-Based for Big and Low Slope Roofs

EVALUATION REPORT Soprema, Inc. 310 Quadral Drive Wadsworth, OH 44281

A. Submit product data sheets and literature verifying physical properties of materials.

A. Submit product data sheets and literature verifying fire ratings and physical properties of materials.

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER GRAVEL SURFACE BUR

DURA 500 LIQUID RUBBER THERMOPLASTIC ROOF COATING SYSTEM BY SUPERIOR POLYMERS INC.

Copolymer BEFORE. Copolymer DURING. Copolymer AFTER. (800) TRI-CHEM 3

Henry #1 CHOICE OF PROFESSIONALS

TEN YEAR SPECIFICATION FOR SEALGUARD VFI-991 FLUID APPLIED SILICONE MEMBRANE FOR REHABILITATION OF LAPPED METAL ROOFS

GUIDE SPECIFICATION SECTION 07576

A. Supplier Qualifications: The ACRYSHIELD SPF Roofing System, as supplied by National Coatings Corporation, is approved for use on the project.

TOPCOAT System Specifications Corrugated Transite Panels

A. Submit product data sheets and literature verifying physical properties of materials.

Recommended Application Procedures

SECTION SELF-ADHERING SHEET FLASHING

PRODUCT INFORMATION. 1/ Version #4

Magna Wall. Elastomeric Coatings (Non-Textured) Product Overview, Instructions, & Data

Pol-E-Base Modified Bitumen Roof System

FireShield Restoration Specifications - EPDM

SC-113 STRONGCOTE VEHICULAR GRADE TRAFFIC DECK MEMBRANE SYSTEM SECTION 07570

SECTION (LIGHT TRAFFIC DECKS OVER CONCRETE) Updated February 18, 2011

SECTION FLUID APPLIED ROOFING. (Commercial Standing Seam Metal Panels)

J&L Building Materials, Inc. Commercial Roofing

Section Fluid-Applied Roofing. EPDM Roof Preservation System Master Guide Specification

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

Enduris * silicone roof coating

Henry #1 CHOICE OF PROFESSIONALS

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant

Refer to Substrates & Surface Preparation.

TOPCOAT Restoration Specifications Structural Concrete

MAKE ROOFS LAST LONGER

Permaroof 500 Liquid Membrane application onto:- Corrugated asbestos roofs

Roof Repair Sealants

Centennial School District Section Material Specifications MATERIAL SPECIFICATIONS:

EPDM SINGLE-PLY SYSTEM SUMMARY

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient GLAS-SHIELD FLUID APPLIED REINFORCED ROOF SYSTEM

Elastomeric Protected Membrane Roofing Fluid-Applied Protected Membrane Roofing. Restoration Coating System (RCS) over Cap Sheet

EPDM ROOF RESTORATION

SECTION A. American Society for Testing and Materials (ASTM):

Nutech Roof Coatings Nutech Paint Application Instructions & Guidelines Nutech Roof Coating Range of Products

Liquid-Applied Roof Solutions ACRYLIC & SILICONE COATINGS PRIMERS & ACCESSORIES

A/D Firefilm III PRODUCT DATA SHEET

INSTALLATION GUIDE SPECIFICATION

Refer to Substrates & Surface Preparation.

APPLICATION GUIDELINE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: COVESTRO, LLC

Fluid Applied All Acrylic Coating System Guide Specification Tropical Roofing Products-TPO/PVC 4.0G911. Built On The Principles of Quality & Integrity

Data Sheet Eco-Smart Membrane WS M1

Desmopol Application Guide for Corrugated Asbestos Roofs

BENEFITS & ADVANTAGES:

Karnak 505 Elasto-Brite M Metal Roof Coating System

900HA is a two component, hand-applied seamless liquid waterproofing that is typically foottrafficable

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES EVALUATION SUBJECT:

HYPERDESMO Polyurethane liquid membrane for waterproofing & protection, easy application. alchimica.com. Page 1/5 DESCRIPTION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

INLAND COATINGS CORPORATION SYSTEM SPECIFICATION FOR MODIFIED BITUMEN ROOFING

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient GLAS-SHIELD FLUID APPLIED REINFORCED ROOF SYSTEM

RECOMMENDED DESIGN SPECIFICATION

IB PVC Single-Ply 50. Technical Data Sheet

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

***********************************************************************************

Packaging: Packaged in 5 gal. pails and 55 gal. steel drums. 260 gal. totes are available as a special order.

STRONGCOTE SC-111 PEDESTRIAN GRADE TRAFFIC DECK COATING SYSTEM SECTION 07570

Carboxane 950 Metallic

DAP ALEX FAST DRY Acrylic Latex Caulk Plus Silicone

DIVISION 9 - FINISHES Section Coatings

UltraPly TPO SA. Product Information. Description: Membrane Preparation: Method of Application: Item Description

Benefits of Cool Metal Roofs There are many benefits of owning a cool metal roof. Here are just a few to consider: What is A Metal Roof?

INLAND COATINGS SYSTEM SPECIFICATION FOR MODIFIED BITUMEN ROOFING

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION

Application guide: Existing BUR systems

GE SCM3500 High Solids Silicone Roof Coating

EDGEWATER, FLORIDA JUNE 14, 2010

Roofcoat Xtra. all- weather protection To Order FREEPHONE SEALS ROOFS 10 YEARS* SAVE s TOP QUALITY

Henry #1 CHOICE OF PROFESSIONALS

Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

Foamed-in-place insulation Sprayed insulation. Spray Foam Insulation for Residential Building Envelope Insulation

SUBMITTALS Descriptive literature: Submit manufacturer's application instructions and technical data sheets or catalog cuts on materials.

SECTION FLUID APPLIED ROOFING

Reducing Over-heating of Buildings by use of White Reflective Roof Coatings (WRRCs)

Transcription:

Florida Department of Transportation CHARLIE CRIST GOVERNOR October 20, 2010 1109 South Marion Avenue Lake City, Florida 32025 STEPHANIE C. KOPELOUSOS SECRETARY To: Prospective Bidders Addendum No.: 1, E2O98, Financial Project # 42556815201 Roof replacement for Palatka Construction in Putnam County 1. The warranty used for the St Augustine and Jacksonville roofing projects is slightly different than the Duro-Last warranty. We will not be able to make any changes to our Warranty? Please advise if this will be acceptable. ANSWER: I have attached a sample copy of the Duro-Last warranty. A warranty for an alternate material must cover all aspects of the Duro-Last warranty in order to be considered equal. If an alternate manufacturer s standard warranty does not cover all items listed in the Duro-Last warranty, the alternate manufacture will have to attach a rider for any excluded items in order to be considered equal. 2. You were correct sir about the requirement of a gypsum product in order to achieve the UL Class A specified for the 2/5 in 12 slope when using a PVC type application. A UL Class A can be met with a JM Built up asphalt application using specification 4FLG. This would require a nailed base sheet to the existing LWC, three plies of GlasPly premier and flood coat and gravel. This would give you the same type roof you have now, accept the plys would be fiberglass not asbestos. JM can offer a 20 year warranty with this application. A UL Class B can be achieved with the same type application using a Glass Cap sheet in lieu of the gravel. We can coat the Cap sheet with our TopGuard 4000 to achieve a SRI value of 102, if required. ANSWER: A built up asphalt roofing system was not specified for this project and will not be approved as an alternate. 3. Duro-last requires DensDeck roofing board to fully adhere the 60 mil to. (alt 2) DensDeck comes in two thicknesses, 1/4 and 1/2. Which is required on this project? ANSWER: ¼ is acceptable as long as it meets all building code requirements. 4. What is the required o.c. spacing of the Vinyl ribs? ANSWER: 16-inches. 5. Duro-Last recommends their PVC eave drip on re-cover applications. Do we propose Duro-Last PVC eave drip or metal for this application? ANSWER: Edge detail shall be in accordance with project specifications which require a 2-piece compression metal edge manufactured by the roof membrane manufacturer. Finish shall be dark bronze Kynar. You must sign, date and fax a copy of this addendum back to me by close of business today to indicate receipt. The bidder is required to acknowledge the addendum in the space provided on the proposal. Thanks, Company Name Patsy Elkins, CPPB Contracts Coordinator Date Phone: 386-758-3703 Fax: 386-758-3791 Signature www.dot.state.fl.us

TopGard 4000 Description TopGard 4000 is a multipurpose, 100% acrylic elastomeric coating for use over a variety of substrates, including asphalt, single ply and metal roofing. TopGard 4000 has unique bleed-blocking properties that make it particularly well suited for coating over asphalt surfaces. TopGard 4000 exceeds several ASTM D 6083 requirements for critical properties such as tensile strength, elongation, wet adhesion and weatherability. Use TopGard 4000 is used as an excellent reflective coating over smoothor mineral-surfaced roofing systems on smooth roofs. It can be used over both modified and built-up roofing systems. For best results, this product should not be applied until the roofing membrane has had the opportunity to cure at least 60 days. Application When applying TopGard 4000, use a brush, roller or spray equipment. Make sure that all surfaces are clean, dry and free of any dirt, grease, oil or other debris that may interfere with proper adhesion. It is recommended that TopGard 4000 be applied in two coats. The first coat should be completely dry (normally 4 to 12 hours) before applying the second coat. Temperatures must be 50 F (10 C) and rising during time of application. Do not apply TopGard 4000 within 24 hours of anticipated rain, dew or freezing temperatures. As with any coating, cooler temperatures and high humidity will slow the cure time. Advantages Fully adhered installation Asphalt bleed blocking 100% acrylic durability Energy savings Prolonged roof life Reduced life cycle costs Energy and the Environment Energy Star Pass Reflectivity: 0.83* California Title 24 Pass Reflectivity: 0.83* Emissivity: 0.88 LEED Reflectivity: 0.83* Emissivity: 0.88 Sustainable Sites (credits 5.1, 5.2, 7.1, 7.2) Energy and Atmosphere (prerequisite 2 and credit 1) * Solar Reflectance Index (SRI) is 102. SRI is tested in accordance with ASTM E 1980. Approvals UL 790 Class A Rating California State Fire Marshall Coverage Type of Roof Fiber glass felts Smooth-surfaced modified sheets Mineral-surfaced BUR/modified sheets Coverage Rate (per coat)* 65-100 ft 2 /gal (1.60-2.45 m 2 /l) 65-100 ft 2 /gal (1.60-2.45 m 2 /l) 50-70 ft 2 /gal (1.23-1.72 m 2 /l) * Coverage rates depend upon weather conditions and substrate. Refer to specific code agency Web sites for exact construction information. Note: When TopGard 4000 is applied as a two-coat process, total cured coating thickness will be approximately 20 mil (0.5 mm). Packaging 5 gal (18.9 l) pails (approximate weight: 60 lb [27.2 kg]) 55 gal (208 l) drums (approximate weight: 673 lb [305.3 kg]) 275 gal (1,041 l) totes (approximate weight: 3,290 lb [1,492.3 kg]) Shelf Life The shelf life of the TopGard products is one year, provided the cans are unopened and have been stored under moderate conditions. Tested in accordance to ASTM D 6083 Physical Properties Property Value Initial Tensile Strength... 270 psi (1.6 MPa) Initial Elongation... 260% Dry Adhesion...6.5 pli Wet Adhesion...5.0 pli Tear Resistance...100 lbf/in (18 km/m) 1,000-hr Accelerated Weathering... No cracking or checking Elongation After Accelerated Weathering... 220% Permeance (perms)...12 Water Swelling...26 Fungi Resistance (Zero No Growth)...Zero rating Volume Solids...52% ± 1% Weight Solids...66% ± 1% Viscosity...110 ± 10 Density... 1.43 g/l Weight...11.9 lb/gal (1.4 kg/l) Non-volatiles (NVMs)...66% ± 1% Refer to the Material Safety Data Sheet and product label prior to using this product. RS-2129 12-08 (Replaces 5-08)