TMS 114 XT TECHNICAL MANUAL

Similar documents
TMS 152 / 152T / 152XT TECHNICAL MANUAL

TMW 450 TECHNICAL MANUAL

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

Series B450 Guide Specification

T series Storefront Framing Flush Glazed Thermally Broken Product Details

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION ALUMINUM WINDOWS

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

SECTION ALUMINUM GLASS FLOOR SKYLIGHT SYSTEMS

SECTION ALUMINUM STORM WINDOWS

SPECIFICATION GUIDE SERIES 800 HEAVY PICTURE WINDOW

SECTION ALUMINUM STORM WINDOWS

SECTION ALUMINUM WINDOWS

A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens.

SECTION FOLDING ALUMINUM FRAMED WALL SYSTEM

SWING DOOR SPECIFICATION

SECTION METAL FRAMED SKYLIGHTS

FL550T 21/2 x5. GUIDE SPECIFICATION Series FL550T Thermal (21/2 x 5 ) Impact-Resistant Storefront. Thermal Impact-Resistant Storefront

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>.

SECTION ALUMINUM WINDOWS

SECTION / METAL FRAMED SKYLIGHTS

System Curtain Wall Thermally Improved System

7000 Series Curtain Wall Information Specifications

North Hanover Township School District North Hanover Township, New Jersey

SECTION C1. SERIES CWW451T THERMALLY BROKEN FRONT GLAZED WINDOW WALL / STOREFRONT SYSTEM 2" X 4 1 /2" for 1" GLAZING ARCHITECTURAL DETAILS

FL550 21/2 x5 GUIDE SPECIFICATION. Impact-Resistant Storefront

Specification Section Storefront Systems has been revised. Omit previously issued Storefront section.

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

SECTION B3 SERIES COS451 FRONT GLAZED STACKING SYSTEM

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

YSD 700H PRODUCT DATA

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

SECTION E INDEX CURTAINWALL FRAMING SYSTEMS

SECTION ALUMINUM ENTRANCES AND STOREFRONTS. A. Section Includes: Aluminum doors and window wall frames.

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>.

SECTION (08410) - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

6400 Series TRIPLE GLAZED THERMAL BREAK CHURCH WINDOWS America's finest custom windows MINIMUM 5 8" AIR SPACE 3 1 2" SCALE = FULL SIZE

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

SECTION GLAZED ALUMINUM CURTAIN WALLS PART 1 GENERAL 1.01 RELATED DOCUMENTS

SECTION STAINLESS STEEL WALL PANELS

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL

HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

Heavy Commercial / Architectural Projected Windows Series L900T AW150

Series x Thermal Triple Set Storefront Framing

Series HX32 Single Hung/Tilt Series FX32 Fixed 3 1/4" High Performance Thermal, Architectural Grade Windows

Guide Specifications - Section SL35. NanaWall SL35, Aluminum Framed Folding System PART 1 - GENERAL

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651

SERIES 5100 AW-PG100-FW FIXED WINDOW

Series 700 Series 7000 * 4 Heavy Commercial Roto-Vent Rotating Ventilator Window

Project No: Pakenham Branch Library, Pakenham, Ontario Section January, 2017 Page 1 of 7

PINNACLE 600/650 HIGH PERFORMANCE CURTAIN WALL apexfacades.com. apexfacades.com 1.2 Pinnacle Pg- 1. Printed on 12/12/17

System WV410 Storefront Window System

Guide Specification for Pre-Engineered Skylight System. A. Engineering, design and drafting of the entire skylight system.

E-Wall System 5800, 5800-I

SECTION ALUMINUM FRAMED STOREFRONTS SERIES ARTICFRONT 45X

apexfacades.com apexfacades.com. Keystone Pg- 1

Custom fabrication in two weeks or less, guaranteed.

System Thermal Clip Storefront System

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

PROJECT IN SERIES 1300 NARROW SIGHT LINE AAMA/WDMA/CSA 101/I.S.2/A Structural Performance:

SERIES 2100 CW-PG60-FW FIXED WINDOW

DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F. 50. Thermal U Value:.61. Main Frame Depth: 4

PROJECT OUT SERIES 6300 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

Building Your Visions

A. Section includes conventionally glazed aluminum curtain walls installed as stick assemblies.

PROJECT OUT SERIES 6300 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)

Series x Thermal Triple Set Storefront Framing

SECTION DETAILS (MECHANICALLY ASSEMBLY)

HORIZONTAL SLIDER SERIES 600 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

SECTION ALUMINUM CURTAIN WALL PART 1 - GENERAL

SERIES 8510 AW-PG85-FW FIXED WINDOW

4600 Series Specifications (Section 08520)

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM

SERIES 6200 HS-HC60 HORIZONTAL SLIDING WINDOW

T SERIES WINDOW SPECIFICATIONS

CASEMENT PROJECT OUT SERIES 2400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 2 3/8

CASEMENT PROJECT OUT SERIES 6400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

SECTION ALUMINUM-FRAMED ENTRANCES AND CURTAINWALL

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651

Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT. Report Number: C Rendered to: Tubelite Inc.

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

SOTA THERMO 3 SERIES SPECIFICATION FOR PREGLAZED & UNITIZED THERMO 3 CURTAINWALL SYSTEM

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

PRODUCT SPECIFICATION THE 9500 SERIES FAMILY - SERIES 9502 / 9503 THERMALLY BROKEN ALUMINUM OUTSWING BALCONY DOOR

SINGLE HUNG SERIES 810 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.61. Main Frame Depth: 4

.1 Section Joint Sealants: Perimeter sealant and back-up materials.

SECTION EXTERIOR GRILLS AND SCREENS

DOUBLE HUNG SERIES 3500 AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.

PART 1 - GENERAL. Pinnacle Glass Glazed Skylights SECTION RELATED DOCUMENTS

Division 8 Section "Flush Wood Doors" for louvers in wood doors. Division 15 Sections for louvers that are a part of mechanical equipment.

Custom fabrication in two weeks or less, guaranteed.

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 SUMMARY. A. Section Includes:

Transcription:

TECHNICAL MANUAL

BLANK PAGE

FEATURES FEATURES is center set flush glazed systems that are 4 1/2" deep with a 2" wide sightline Glaze from the outside or inside Screw spline or shear block fabrication Glazing options up to 1-1/8" thick Available in anodized and standard or custom painted finishes Readily available from stock APPLICATIONS Storefront, Punched Openings, or Ribbon Windows Single span Integrated entrance framing to allow Pittco standard entrances or other speciality entrances to be incorporated SYSTEM PERFORMANCE Description Test Method Allowed Achieved Test Report Structural ASTM E 330 N/A 25 psf 20-10 Air ASTM E 283 0.06 cfm/ft2 @ 6.24 psf 0.02 cfm/ft2 @ 6.24 psf 20-10 Water (Static) Water (Dynamic) ASTM E 331 AAMA 501.1 None @ 5 psf None @ 5 psf None @ 12 psf None @ 12 psf 20-10 20-10 CRF SIM. ANALYSIS N/A 65+ 23-3 U Value NFRC 100 N/A 0.37+ 23-2 SHGC NFRC 200 N/A 0.35+ 23-2 CR NFRC 500 N/A 46+ 23-2 OITC STC ASTM E 90/E 1433 ASTM E 90/E 413 N/A N/A 30 36 19-03 19-03 + 1" IGU (1/4-1/2-1/4) Solarban 60 Low-E Annealed Glass, Air Filled, Aluminum Spacer. FOR SPECIFIC PRODUCT APPLICATIONS PLEASE CONTACT YOUR PITTCO REPRESENTATIVE 1

BLANK PAGE 2

INDEX PRODUCT DESCRIPTION......................... PAGES 4 TO 8 EXPLODED VIEWS.............................. PAGE 9 1/4 SIZE DETAILS.............................. PAGES D1 TO D3 ENTRANCE DETAILS............................ PAGE D4 WINDLOAD CHARTS............................ PAGES S1 TO S3 DEADLOAD CHARTS............................ PAGE S4 SECTION PROPERTIES.......................... PAGE S5 THERMAL CHARTS............................. PAGES T1 TO T2 3

PRODUCT DESCRIPTION BASIC USES / RELATED USES Framing is designed for high thermal performance flush, center glazed storefront assembly Vertical mullions are typically open back aluminum members, with solid face and flush closure side plates forming tubular members Horizontal mullions are of hollow aluminum with removable glazing stops Glazing is insulating glass unit Corners are available for 90 and 135 degrees Glass may be transparent, opaque, or decorative types Framing is intended for one story applications Framed assembly may be fitted to most rigid and stable framed opening assemblies PRODUCT ATTRIBUTES AND CHARACTERISTICS Aluminum frame members are double thermal break design Framing and glazing stops are designed for glass and panels Wind pressure resistance and pressure equalization are standard within the frame assembly Weep containment and condensate water collection and drainage to the exterior at concealed weeps are standard Integral door frames are available SELECTION CRITERIA Quality, economy, and high thermal performance are provided at a reasonable cost Framing is designed for Interior or exterior environments APPLICABLE STANDARDS, RELATED REFERENCES AA (Aluminum Association) - Designation System for Aluminum Finishes AAMA SFM-1-87 - Aluminum Storefront and Entrance Manual AAMA 501.1-05 - Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors using Dynamic Pressure AAMA 611-98 - Voluntary Specification for Anodized Architectural Aluminum AAMA 1503-98 - Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors, and Glazed Wall Sections AAMA 2604-05 - Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels ASTM A123/A123M - Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products ASTM B209 - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate ASTM B221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wires, Profiles, and Tube ASTM E283 - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen ASTM E330 - Standard Test Method for Structural Performance of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference ASTM E331 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference 4

PRODUCT DESCRIPTION QUALITY, TESTS, CERTIFICATIONS, AND APPROVALS Air Infiltration: Maximum leakage of 0.02 cfm/sq ft (0.1 L/m2.s) when measured in accordance with ASTM E283 at a test pressure of 6.24 psf (300 Pa) Static Water Leakage: No uncontrolled leakage, when measured in accordance with ASTM E331 at a test pressure difference of 10.0 psf (480 Pa) Dynamic Water Leakage: No uncontrolled leakage, when measured in accordance with AAMA 501.1 at a test pressure difference of 10.0 psf (480 Pa) Structural Performance: Maximum deflection less than 1/175 of the span length and no damage to the assembly, when measured in accordance with ASTM E330 at a test pressure of 25 psf (1200 Pa). (Air, water, and structural tests were performed on TMS 114 T system and due to very similar design are used to represent this product) Condensation Resistance Factor (CRF): 66 when measured in accordance with AAMA 1503 with clear 1 insulated glass unit (1/4, 1/2, 1/4) Insulation U-Factor: 0.52 BTU/hr/sq ft/degrees F when measured in accordance with AAMA 1503 with clear 1 insulated glass unit (1/4, 1/2, 1/4) PACKAGING, HANDLING, AND PROTECTION INSTRUCTIONS Packaged in specially designed heavy cartons or shipped pre-fabricated and assembled SPECIAL WARRANTY One (1) year LIMITATIONS Framing is limited to applications of one story in height Not intended for continuous members for multiple floor applications SAFETY PRECAUTIONS Normal precautions required AVAILABILITY Framing is available in all regions of USA COST Varies with elevation, configuration and finish desired 5

PRODUCT DESCRIPTION PRODUCT PROPERTIES MATERIAL, COMPOSITION AND DESIGN Aluminum: 6063-T6 alloy and temper, to ASTM B221 or ASTM B221M Fasteners: Stainless steel, or zinc plated carbon steel Perimeter Anchors: Aluminum, or steel that will be isolated from aluminum components Glazing Gaskets: Wedge-type, Ethylene Propylene Diene Monomer (EPDM) rubber with non-stretch cord Glass Stops: Snap-in type Thermal Barrier: Poured and Debridged Polyurethane and Thermal Slots SHAPE AND DIMENSIONS Frame Size: 2 x 4-1/2 inch (51 x 114 mm) Glass Edge Bite: 3/8 inch (9.5mm) Glazing Thickness Accepted: 1/8 inch (3 mm) to 1-1/8 inch (29 mm) in increments of 1/16 inch (1.5 mm) except 7/16 inch (11 mm), 9/16 inch (14 mm), 11/16 inch (17 mm), and 13/16 inch (21 mm) SHOP FABRICATION AND ASSEMBLY Provide for flush glazing on all sides with no projecting stops Configurations: Two-piece snap together mullions Solid tubular mullions, assembled to specially designed shear block clips Accessories: Expansion Mullions Corner Mullions Open Back Perimeter Members Integral Door Frames Flashing, Subsills Head Receptor Heavy Duty Mullions Standard Steel Reinforcing COLORS AND TEXTURES Architectural anodic coating, in accordance with AAMA 611; o Aluminum Association Designation. AA-M10C22A31 - Class II - (Pittco #42 Clear) AA-M10C22A41 - Class I - (Pittco #43 Clear) AA-M10C22A44 - Class I - (Pittco #59 Champagne) AA-M10C22A44 - Class I - (Pittco #60 Light Bronze) AA-M10C22A44 - Class I - (Pittco #61 Medium Bronze) AA-M10C22A44 - Class I - (Pittco #62 Dark Bronze) AA-M10C22A44 - Class I - (Pittco #63 Black) 6

PRODUCT DESCRIPTION Architectural organic coating, in accordance with AAMA 2604 (50% Kynar 500 ); o Finish of Exposed Aluminum shall be compliant with the performance standards set forth in AAMA Specification 2604, High Performance Organic Coatings on Aluminum o Type: Factory Applied, High Performance, 50% Polyvinylidene Fluoride (PVDF) Coating formulated by a licensed paint manufacturer, and applied by Paint Manufacturer's Warranty-Approved Applicator o Pretreatment: Applicator to pre-treat the aluminum with solutions to remove organic and inorganic surface soils, remove residual oxides, followed by a Chrome Phosphate or Chromate Coating to ensure adhesion to the aluminum o Specify color code, e.g. UC 40577(Duranar Black) Architectural organic coating, in accordance with AAMA 2605 (70% Kynar 500 ); o Finish of Exposed Aluminum shall be compliant with the performance standards set forth in AAMA Specification 2605, Superior Performing Organic Coatings on Aluminum o Type: Factory Applied, High Performance, 70% Polyvinylidene Fluoride (PVDF) Coating formulated by a licensed paint manufacturer, and applied by Paint Manufacturer's Warranty-Approved Applicator o Pretreatment: Applicator to pre-treat the aluminum with solutions to remove organic and inorganic surface soils, remove residual oxides, followed by a Chrome Phosphate or Chromate Coating to ensure adhesion to the aluminum o Specify color code, e.g. UC 40577(Duranar Black) PRODUCT PLACEMENT PREPARATION WORK Ensure openings are of proper size, and are plumb, square, level and in the proper location and alignment INSTALLATION Align installed assembly plumb and level, free of warp or twist Maintain dimensional tolerances, aligning with adjacent work Seal joints between framing and building structure watertight Follow guidelines in Pittco Fabrication, Sealant and Erection Brochure START-UP AND OPERATION Not Applicable OWNER'S MAINTENANCE INSTRUCTIONS Wash surfaces with warm water and mild soap; wipe clean, at least once a year 7

PRODUCT DESCRIPTION Corporate Identification Pittco Architectural Metals, Inc 1530 Landmeier Road Elk Grove Village, Illinois 60007 Tel: (847) 593-3131 Fax: (847) 593-9946 Toll-Free: (800) 992-7488 Internet: http:// E-mail: info@pittcometals.com Technical Services Available Toll-Free: (800) 992-7488 Classification and Filing MasterFormat Subset of Section 08410 - Metal Framed Storefronts UniFormat Section B2030 - (exterior entrance frames) or C1020 (interior entrance frames) 8

EXPLODED VIEWS SCREW SPLINE ASSEMBLY THE SCREW SPLINE SYSTEM ALLOWS A FRAME TO BE INSTALLED FROM UNITIZED ASSEMBLIES. SCREWS A THROUGH THE BACK OF THE VERTICALS INTO SPLINES EXTRUDED IN THE HORIZONTAL FRAMING MEMBERS UNITS ARE THEN SNAPPED TOGETHER TO FORM A COMPLETE FRAME OPEN BACK MULLION THERMAL ISOLATOR SNAP-IN FILLER HEAD HORIZONTAL GLASS STOP SILL GLASS STOP SUBSILL SHEAR BLOCK ASSEMBLY THE SHEAR BLOCK METHOD OF FABRICATION IS AN ALTERNATE METHOD OF FABRICATION. HOR ARE ATTACHED TO THE VERTICAL MULLIONS WITH SHEAR BLOCKS. THIS METHOD MUST BE US TUBULAR VERTICAL MULLIONS. OPEN BACK MULLION SNAP-IN FILLER THERMAL ISOLATOR SHEAR BLOCK HEAD SHEAR BLOCK HORIZONTAL GLASS STOP SHEAR BLOCK SILL GLASS STOP SUBSILL 9

TYPICAL FRAMING DETAILS (Outside Glazed) 3 1 2 4 5 23-028 (JAMB) SCREW SPLINE 23-028 (JAMB) 23-029 (GLAZING FILLER) 23-028 (JAMB) SHEAR BLOCK 23-028 (JAMB) 23-029 (GLAZING FILLER) 1 JAMB 2 VERTICAL 1 JAMB 2 VERTICAL 3 HEAD 23-028 (HEAD) 3 HEAD 23-028 (HEAD) 23-034 (SHEAR BLOCK) 4 HORIZONTAL 23-039 (HORIZONTAL) 23-031 (GLASS STOP) 4 HORIZONTAL 23-039 (HORIZONTAL) 23-031 (GLASS STOP) 23-040 (SHEAR BLOCK) 5 SILL 23-030 (SILL) 23-031 (GLASS STOP) 23-000 (SUB-SILL) 5 SILL 23-030 (SILL) 23-031 (GLASS STOP) 23-000 (SUB-SILL) 23-041 (SHEAR BLOCK) D1 DETAILS

3 TYPICAL FRAMING DETAILS (Inside Glazed) 1 2 4 5 23-028 (JAMB) SCREW SPLINE 23-028 (JAMB) 23-029 (GLAZING FILLER) 23-028 (JAMB) SHEAR BLOCK 23-028 (JAMB) 23-029 (GLAZING FILLER) 1 JAMB 2 VERTICAL 1 JAMB 2 VERTICAL 3 HEAD 23-030 (HEAD) 23-031 (GLASS STOP) 3 HEAD 23-030 (HEAD) 23-031 (GLASS STOP) 23-041 (SHEAR BLOCK) 4 HORIZONTAL 23-039 (HORIZONTAL) 23-031 (GLASS STOP) 4 HORIZONTAL 23-039 (HORIZONTAL) 23-031 (GLASS STOP) 23-040 (SHEAR BLOCK) 5 SILL 23-028 (SILL) 23-000 (SUB-SILL) 5 SILL 23-028 (SILL) 23-000 (SUB-SILL) 23-034 (SHEAR BLOCK) D2 DETAILS

CORNER DETAILS 23-043 23-044 23-043 23-043 2 POCKET CORNER 90 CORNER 135 CORNER 23-032 23-169 23-349 23-032 EXPANSION MULLION FULL LENGTH FLAT FILLER SNAP IN POCKET FILLER HEAVY WALL MULLION 23-031 23-095 23-102 23-101 23-029 HEAD RECEPTOR 4 1 2 " x 41 2 " HORIZONTAL 41 2 " SILL D3 DETAILS

1 MISCELLANEOUS DETAILS 6 2 7 10 4 3 5 8 3 9 4 23-136 (MULLION) SINGLE ACTING DOOR JAMBS 5 23-136 (MULLION) 23-030 (HEAD) 23-031 (GLASS STOP) 1 TRANSOM HEAD 6 23-136 (MULLION) 7 23-136 (MULLION) TRANSOM JAMBS Jambs above transom bar are routed out to accept glass holding insert with or without steel reinforcing. 23-136 (TRANSOM HEAD) 23-042 (SHEAR BLOCK) 23-046 (SHEAR BLOCK) 23-136 (TRANSOM HEAD) 23-042 (SHEAR BLOCK) 23-046 (SHEAR BLOCK) 2 DOOR HEAD 10 DOOR HEAD 8 23-136 (MULLION) SINGLE ACTING DOOR JAMBS 9 23-136 (MULLION) D4 DETAILS 3 BOTTOM RAIL

WINDLOAD CHARTS SYSTEM ANALYSIS CRITERIA: ALUMINUM: 6063-T6 DEFLECTION LIMITS: L/175 FOR SPANS LESS THAN 13'-6" L/240 + 1/4" FOR SPANS GREATER THAN 13'-6" CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4" LATERAL BRACING OR HORIZONTAL MEMBER SPACING: 48" O.C. (MAXIMUM) (FOR HORIZONTAL SPACING GREATER THAN 48" CONTACT PITTCO ENGINEERING) SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUAL SIMPLE SPAN CONDITION A B C D E 23-028 23-029 A = 15 PSF B = 20 PSF C = 25 PSF D = 30 PSF E = 40 PSF S1

SYSTEM ANALYSIS CRITERIA: ALUMINUM: 6063-T6 DEFLECTION LIMITS: L/175 FOR SPANS LESS THAN 13'-6" L/240 + 1/4" FOR SPANS GREATER THAN 13'-6" CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4" LATERAL BRACING OR HORIZONTAL MEMBER SPACING: 48" O.C. (MAXIMUM) (FOR HORIZONTAL SPACING GREATER THAN 48" CONTACT PITTCO ENGINEERING) SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUAL SIMPLE SPAN CONDITION WINDLOAD CHARTS A B C D E 23-139 23-029 A = 15 PSF B = 20 PSF C = 25 PSF D = 30 PSF E = 40 PSF A B C D E 20-139 20-029 WITH 16-501 STEEL S2 VERTICAL REINFORCING IS ANALYZED AS AN ASSEMBLY WITH THE ALUMINUM SECTIONS.

WINDLOAD CHARTS SYSTEM ANALYSIS CRITERIA: ALUMINUM: 6063-T6 DEFLECTION LIMITS: L/175 FOR SPANS LESS THAN 13'-6" L/240 + 1/4" FOR SPANS GREATER THAN 13'-6" CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4" LATERAL BRACING OR HORIZONTAL MEMBER SPACING: 48" O.C. (MAXIMUM) (FOR HORIZONTAL SPACING GREATER THAN 48" CONTACT PITTCO ENGINEERING) SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUAL SIMPLE SPAN CONDITION A B C D 23-136 E A = 15 PSF B = 20 PSF C = 25 PSF D = 30 PSF E = 40 PSF A B C D E 23-032 23-032 COMBINED SECTIONS ARE ANALYZED AS AN ASSEMBLY S3

SYSTEM ANALYSIS CRITERIA: ALUMINUM: 6063-T6 HORIZONTAL OR DEADLOAD LIMITATIONS ARE BASED UPON 1/8" MAXIMUM ALLOWABLE DEFLECTION WITH 1" THICK INSULATED GLASS SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUAL SIMPLE SPAN CONDITION A 15% REDUCTION IN SECTION PROPERTIES TO ACCOUNT FOR THE THERMAL BREAK THERMAL SECTIONS DEADLOAD CHARTS 23-039 (HORIZONTAL) 23-031 (GLASS STOP) A B A = SETTING BLOCKS AT 1/8 POINTS B = SETTING BLOCKS AT 1/4 POINTS S4

SECTION PROPERTIES STRUCTURAL PROPERTIES of TMS 114XT THERMAL FRAMING Part Number Ix Sx Iy Sy 23-028 2.392 1.063 0.423 0.349 23-030 1.855 0.748 0.287 0.286 23-032 2.219 0.965 0.214 0.179 23-039 2.138 0.883 0.434 0.367 23-043 2.300 0.772 1.853 0.562 23-044 2.293 0.783 1.838 0.548 23-095 4.118 1.839 2.221 0.964 23-099 0.256 0.179 0.031 0.066 23-136 4.584 1.997 1.009 0.946 23-139 5.835 2.593 0.669 0.560 23-168 0.480 0.233 0.010 0.021 23-462 3.106 1.017 1.625 0.624 16-501 Steel 0.808 0.458 0.023 0.041 S5

THERMAL CHARTS T1

THERMAL CHARTS T2