TECHNICAL NOTE THE NEXT GENERATION OF MICROPLATES

Similar documents
TECHNICAL NOTE THE NEXT GENERATION OF MICROPLATES

FOR LABORATORY USE ONLY

Adapta Assay Setup Guide on the BioTek Instruments Synergy 2 Multi-Mode Microplate Reader

Setup for LanthaScreen Terbium Assays on SpectraMax M5/M5e Microplate Reader with SoftMax Pro 6 Software

Omnia Assay Setup Guide on the Tecan Safire 2 Microplate Reader

Omnia Assay Setup Guide on the Thermo Scientific Varioskan Flash Multimode Reader

Setup for LanthaScreen Terbium Assays on SpectraMax Paradigm Microplate Detection Platform with SoftMax Pro 6 software

Measuring cell proliferation using the CyQUANT Cell Proliferation Assay with SpectraMax Microplate Readers

Faster ELISA results with CatchPoint SimpleStep ELISA kits

Automating ELISAs on Tecan s Freedom EVO using Optimiser technology from Siloam Biosciences

LanthaScreen Europium Assay Setup Guide on the BMG LABTECH CLARIOstar Microplate Readers

Data Sheet. PD-1[Biotinylated]:PD-L2 Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

Data Sheet PARP1 Chemiluminescent Assay Kit Catalog # 80569

Using ULS24 CMOS Bio-imager as a Readout Sensor for Chemiluminescence Immunoassay and DNA Hybridization Assay

Utility of Variable Bandwidth Monochromators for Quantification of Fluorescent Probes in Produced Effluent Water

Data Sheet. PD-1:PD-L1[Biotinylated] Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

Data Sheet. CTLA4:B7-1[Biotinylated] Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

Data Sheet. CTLA4[Biotinylated]:B7-2 Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

Data Sheet PARP1 Chemiluminescent Assay Kit Catalog # 80551

Validation and Comparison of Single-Step Flash and Dual-Spectral Luciferase Reporter Gene Assays using the Synergy Line of Microplate Readers

Data Sheet. PD-1[Biotinylated]:PD-L1 Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

Setting up a Run of Real-time PCR CFX 96 Real-Time System

ab ADHP HRP substrate

luminometer.committed

E. COLI HOST CELL PROTEIN ELISA KIT ASSAY PRINCIPLE PRODUCT MANUAL HCP-002 E. COLI HOST CELL PROTEIN ELISA KIT KIT INCLUDES

Data Sheet Histone H3 Dimethyl-K27 ELISA Detection Kit Catalog # 53030

ARM-D Kits Data Acquisition and Analysis Guide

Timesheets. Printing Timesheets for a Department

ARM-D Kits Data Acquisition and Analysis Guide

QuantiFluor dsdna System

Porcine IgG ELISA. Package Insert

Human CRP Precoated ELISA kit

Sword ELISA Booster. For Human IL-33. For use with Human IL-33 Quantikine ELISA from R&D Systems (Cat# D3300)

Rat IgA ELISA. Package Insert

Data Sheet EHMT1 (GLP) Chemiluminescent Assay Kit Catalog # Size: 96 reactions

SpectraMax Paradigm Microplate Reader

Data Sheet PARP1 Chemiluminescent Assay Kit Catalog # 80551

Enzyme Linked Immunosorbent Assay for Horseradish Peroxidase Labeled Antibodies. (Cat. # )

LightCycler 480 Instrument Quick Guide

Proteasome Activity Fluorometric Assay Kit II (Cat. # J4120)

Optimization of a Multi-Mode Detection Model for Measuring Real-time Cellular Respiration and Mitochondrial Function using Fluorophoric Biosensors

Daily Hours: Clocking In & Out

Amplex UltraRed Reagent

Fully Automated EIA System. True open flexibility.

ARM-D Kits Data Acquisition and Analysis Guide. Real-Time PCR Platform: Applied Biosystems QuantStudio 7 Flex Real-Time PCR System

Data Sheet Histone H4(R3) Universal Methyltransferase Assay Kit Catalog #52074

LightCycler 480 Instrument Quick Guide Protein Melting

Cell-Based ELISA. Catalog Number K E. Cell-Based ELISA to Characterize Human Breast Cancer Stem Cell in culture.

Human Anti-Muscarinic Cholinergic Receptor 1 (M1)-Antibodies

RayBio HDAC-8 Inhibitor Screening Kit

Performing the CTA Carryover PVT Procedure on the LXi or DXC 600i System

SpectraMax Quant AccuBlue Pico dsdna Assay Kit

UV-Induced DNA Damage ELISA (CPD Quantitation)

Comparison of HTRF compatible microplate readers from Tecan Ultra Evolution, GENios Pro & Safire² - camp HiRange kit

Instruction Manual. Catalog # For use with Bio-Plex Manager Software Version 4.0 and MCV plate III

Sword ELISA Booster. For Human IL-23. For use with the R&D Systems Human IL-23 Quantikine ELISA Kit (Cat# D2300B)

Considerations Dynamic Range Detection Linearity Components Software Comparing qpcr Instrumentation Sensitivity Specificity of Detection sigma.

Evaluating Microplate Detection Instruments

CELL HEALTH. reliable cell viability data. instant time savings. PrestoBlue Cell Viability Reagent

Lead Scoring CRM Integration

Quant-iT dsdna Broad-Range Assay Kit

A Comparison of PerkinElmer s LANCE camp Assay Performance to that of State of the Art Competitive Technologies

Mouse Collagen Type III ELISA

CytoScan SRB Cell Cytotoxicity Assay

Cat Toxoplasma IgG ELISA Kit

1. INTRODUCTION 2. EXPERIMENTAL 3. REFERENCES

Applied Biosystems 7900HT Fast Real-Time PCR System. Performing Fast Gene Quantitation with 384-Well Plates DRAFT

Anti-beta 1 Adrenergic Receptor Antibodies (IgG) ELISA

Measure-iT Thiol Assay Kit (M30550)

RayBio Caspase-3 Inhibitor Drug Screening Kit

Instructions for Use

PERFORM Operating Document. Use and Maintenance of Hybrid Multi-Mode Microplate Reader and Washer. 01 New POD 20-July-2013

PowerSeq Quant MS System

TaqMan Residual DNA Detection Kit Chinese Hamster Ovary v2 Protocol

Transcreener PDE Assay

Goat immunoglobulin G (IgG) ELISA Kit

SpectraMax Multi-Mode Microplate Readers

Brink Admin Portal Quick Reference Guide

FOR FISH SAMPLES PROD. NO.: B / B

Normalization, Dilution and Transfer Methods for the Maxprep TM Liquid Handler Technical Manual

A high-performance, easy-to-use multimode reader for luminescence, fluorescence, absorbance, BRET and FRET applications.

Zen Myeloperoxidase (MPO) ELISA Kit

SpectraMax Quant AccuClear Nano

Human Fibrinogen ELISA Quantitation Kit. Manual

Rat Tissue-type Plasminogen Activator (tpa) Total Antigen ELISA

QS S Assist TK_ELISA Kit

Human Haptoglobin ELISA Quantitation Kit. Manual

QuantiFluor ONE dsdna System

Human Serum Albumin (HSA) ELISA Quantitation Kit. Manual

SensoLyte Rh110 Factor Xa Assay Kit *Fluorimetric*

FAR RED FP. GDP FP Assay. Technical Manual. v071814

AssayLite Human Alpha-1-Antitrypsin and Prealbumin Multiplex Fluorescent Immunoassay Kit

CapitalBio LuxScan TM. HT24 High Throughput Microarray Scanner. Exploit the full capacity of your lab

Mouse OVA IgG1 ELISA. Catalog Number M046072

Tabs3 Quick Start Guide

Optimizing Dual-Glo Luciferase Assays with the Synergy HT Multi-Detection Microplate Reader

Open the BOL Form A BOL form opens when you click on BOL drop down menu on the EMS toolbar and select BOL option.

Cyto-Mine. The Single Cell Analysis and Monoclonality Assurance System

Data Sheet. PD-1[Biotinylated]:PD-L1 Inhibitor Colorimetric Screening Assay Kit Catalog # Size: 96 reactions

Angus AnyWhere. Reports User Guide AUGUST 2012

Transcription:

TECHNICAL NOTE TN0002: Optimiser Microplate System (ELISA) Setup Guide on the BioTek FLx800 Fluorescence Microplate Reader THE NEXT GENERATION OF MICROPLATES Better Immunoassays through Innovative Microfluidics

Table of Contents READER SETUP WITH BIOTEK FlX800 READER:... 3 Recommended Optics... 3 Instrument Setup... 3 Sensitivity Adjustment... 9 GENERAL READER SETUP GUIDANCE:... 12 SILOAM BIOSCIENCES, INC. Page 2 of 13 DOC ID: OPTI 2 MS 0006 A1

READER SETUP WITH BIOTEK FlX800 READER: The BioTek FLx800 Fluorescence Microplate Reader has been tested for compatibility with Siloam's Optimiser microplate System in ELISA assay with OptiGlow chemifluorescent substrate. Please refer to the Optimiser Technology page on Siloam s website for more details on the principles behind the Optimiser microplate platform. For more detailed information and technical support of BioTek instruments or Gen5 software, please contact BioTek Instruments at 1 888 451 5171. Recommended Optics BioTek Instruments Part Number Wavelength Excitation 7082247 528/20 nm (or similar) Emission 7082224 590/35 nm (or similar) Instrument Setup 1) Turn on the plate reader, and open up BioTek Gen5 software on computer. 2) Select Protocol in the "Create a New Item" menu. SILOAM BIOSCIENCES, INC. Page 3 of 13 DOC ID: OPTI 2 MS 0006 A1

3) A blank protocol will open. Select "Procedure" on the left hand side and a new window will open up. Select 96 WELL PLATE in the plate type. Optimiser plate fits 96 well SBS standard in all specifications. Please use the similar 96 well plate type option in other fluorescence readers, such as 96 well plate, 96 well standard or 96 well SBS standard. SILOAM BIOSCIENCES, INC. Page 4 of 13 DOC ID: OPTI 2 MS 0006 A1

4) Select the "Read" tab. Select "Fluorescence" and "Endpoint" from the drop down menus. Select the proper filters, Top for optic position and input 45 for sensitivity*, as shown below. Also, select the wells of your plate you wish to read by clicking on the "Full Plate" icon to the left. * Please see Sensitivity Adjustment at Page 9 SILOAM BIOSCIENCES, INC. Page 5 of 13 DOC ID: OPTI 2 MS 0006 A1

5) Your screen should now look like the picture below, and then select "OK". In the upper left, under "File", save your protocol. SILOAM BIOSCIENCES, INC. Page 6 of 13 DOC ID: OPTI 2 MS 0006 A1

6) To run an actual experiment, click on "File" again, and select "New Experiment" from the drop down list. A smaller window will appear; select your protocol and click "OK". SILOAM BIOSCIENCES, INC. Page 7 of 13 DOC ID: OPTI 2 MS 0006 A1

7) A new window will again appear; this is the experiment window. Insert your plate to be read and click on the "Read Plate" icon with the small green arrow (second from last icon in the lower toolbar). SILOAM BIOSCIENCES, INC. Page 8 of 13 DOC ID: OPTI 2 MS 0006 A1

8) One last popup will appear. Select "Read" and instrument will commence reading your plate. Note: There are several options for collecting data from the BioTek Gen5 software. Data can be exported directly to excel, or appropriate macros can be prepared within the BioTek software. For more information on data output options, please refer to reader user manual or contact BioTek Technical Support. Sensitivity Adjustment When defining reading parameters for Fluorescence analysis, setting the PMT sensitivity (or gain in some types of fluorescence reader) is important for obtaining useful measurements. BioTek recommends a setting between 40 120 for Fluorescence assays. Siloam s OptiGlow is a strong chemifluorescence substrate which requires low value on sensitivity setting. A manual sensitivity/gain setting is recommended for reading Optimiser microplates. Following is an instruction for determining the sensitivity setting with mixture of HRP and OptiGlow substrate. It use BioTek Flx800 as an example but can be applied to other fluorescence microplate reader as well. Material: 1) Siloam s SAv HRP (cat# OMR HRP). Note: Any HRP conjugate with concentration greater than 1 µg/ml can be used for this test with following experimental protocol 2) Siloam s OptiGlow substrate. 3) One Optimiser Microplate. Well A1 will be used for the sensitivity adjustment SILOAM BIOSCIENCES, INC. Page 9 of 13 DOC ID: OPTI 2 MS 0006 A1

Experimental Procedure: 1) In a clean plastic tube, add 50 µl of OptiGlow A, 50 µl of OptiGlow B, 1 µl of OptiGlow C, and 1 µl of supplied SAv HRP stock solution, mix well, and wait for 2 minutes. The substrate will be fully developed and stable for hours. 2) Load 4 µl of mixture into well A1 of Optimiser microplate and wait until the well is empty (do not use pad/holder) 3) There are two methods to determine the sensitivity with BioTek Flx800: a) Try different sensitivity manually so that the signal from well A1 is close to 11,000 1. b) Use auto sensitivity adjustment. An example operation for BioTek Flx800 is shown as below: Follow the instruction of Instrument Setup at Page 3, in step 4), select the option tab under the sensitivity instead of setting the sensitivity manually. Your screen should now look like the picture below. Select "Automatic Sensitivity Adjustment" and "Scale to High Wells". Also, select A1 as the reference well by clicking on the tab next to Scale Wells. Input 11000. The reader will automatic choose the gain/sensitivity which makes the reading of A1 close to the given value. 1 The RFU max value of 11,000 is selected for readers with linear operating range up to ~100,000 RFU. Setting RFU max =11,000 will allow users to: (a) compare results with Siloam s data and allow for effective troubleshooting if needed and (b) use the wide dynamic range protocols as described in Application Note: AN0015 Optimiser Assays with Extended Dynamic Range SILOAM BIOSCIENCES, INC. Page 10 of 13 DOC ID: OPTI 2 MS 0006 A1

And then find the sensitivity value by right clicking the Procedure and selecting AutoSensitivity Results, and use the number for setting the sensitivity. 4) Use the same sensitivity setting, read one blank well of Optimiser, the readout should be less than 50. 5) Save or record this sensitivity setting. 6) This defines the max reading (RFU max ) that Optimiser based assays can reach with this reader sensitivity setting. The gain setting will be valid for all Optimiser based assays. Readjust sensitivity only if a) changing the reader or b) changing the optical unit such as light bulb, filters, etc. SILOAM BIOSCIENCES, INC. Page 11 of 13 DOC ID: OPTI 2 MS 0006 A1

GENERAL READER SETUP GUIDANCE: Optimiser based assays are compatible with standard fluorescence plate readers and multi mode plate readers with fluorescence reading capability. Below is the general guidance for setting up the readers. For further assistance, please contact Siloam s technical support. Step 1: Selecting the wavelength for excitation and emission light: Figure 5. Normalized absorption (left) and emission (right) spectra of OptiGlow chemifluorescent substrate. Assays on Optimiser uses OptiGlow substrate, which can be detected using the appropriate excitation and emission settings (Figure 5). Quantitation does not require filters that precisely match the excitation/emission maxima. However, a non overlapping filter set with a bandpass that includes the excitation/emission spectra is required. Wavelengths at 530 575 nm for excitation and 585 630 nm for emission can be used for detection. Below are examples for different types of readers: Filter based readers: install 528/20 nm (or similar) filter for excitation, and 590/35 nm (or similar) filter for emission Monochromator based readers: in wavelength setting, set excitation at 528/20 nm, and emission at 590/35 nm Readers with pre configured optical set: select the wavelength setting for Rhodamine or Cy3. Step 2: Selecting the plate type: Optimiser microplate fits 96 well SBS standard in all specifications. Please use 96 well standard or similar in plate type setting. Step 3: Selecting the probe direction: Please use top reading for probe direction. Step 4: Selecting the sensitivity/gain: When defining reading parameters for fluorescence analysis, setting the PMT sensitivity (or gain in some types of fluorescence reader) is important for obtaining useful measurements. A manual sensitivity/gain setting is recommended for reading Optimiser microplates. The procedure is as described below: 1) In a clean plastic tube, add 50 µl of OptiGlow A, 50 µl of OptiGlow B, 1 µl of OptiGlow C, and 1 µl of Siloam s SAv HRP stock solution, mix well, and wait for 2 minutes. The substrate will be fully developed and stable for hours. Note: Any HRP conjugate with concentration greater than 1 µg/ml can be used for this test with following experimental protocol 2) Load 4 µl of mixture into one well of Optimiser microplate and wait until the well is empty (do not use pad/holder) 3) Read that well in reader with various gain setting. 4) Select the gain which gives the RFU reading closest to 11,000. 5) Use the same gain setting, read one blank well of Optimiser, the readout should be less than 50. 6) Save or record this gain setting. 7) This defines the max reading (RFU max ) that Optimiser based assays can reach with this reader gain/sensitivity setting. The gain setting will be valid for all Optimiser based assays. Repeat Step 4 if a) changing the reader or b) changing the optical unit such as light bulb, filters, etc. SILOAM BIOSCIENCES, INC. Page 12 of 13 DOC ID: OPTI 2 MS 0006 A1

Technical Assistance: If you require assistance, please contact Siloam Biosciences, Inc. Technical Support at 513 429 2976 or techsupport@siloambio.com. Additional technical assistance is available under the Technical Support tab on the Siloam Biosciences web site (http://siloambio.com/). Using Optimiser Immunoassay Microplate Video Optimiser User s Guide Reader Settings Quick Reference Guide Frequently Asked Questions Application Notes Two additional videos appear under the Technology tab of the web site. Optimiser Principles of Operation Running an Assay with Optimiser Better Immunoassays Through Innovative Microfluidics Siloam Biosciences, Inc. 413 Northland Blvd., Cincinnati, OH 45240 Phone: 513 429 2976 Fax: 513 429 2946 www.siloambio.com SILOAM BIOSCIENCES, INC. Page 13 of 13 DOC ID: OPTI 2 MS 0006 A1