Appendix D. -Weyerhaeuser Fire Rated Assembly Listings-

Similar documents
LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

Stark Truss Company, Inc. Revised December 14, 2018

PinkWood Ltd. Revised September 29, 2017

Boise Cascade Company Revised June 25, 2018

LISTING INFORMATION OF Weyerhaeuser - TJI Joists SPEC ID: 26948

ESR ICC Evaluation Service, Inc. Issued November 1, 2003 This report is subject to re-examination in one year.

PFC-5804* Reissued February 1, Filing Category: DESIGN Wood

LISTING INFORMATION OF Mitek Design No. MCI/WI SPEC ID: MiTek Canada, Inc. 100 Industrial Road Bradford, ON L3Z 3G7 Canada

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California *Revised April 2003

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: PACIFIC WOODTECH CORPORATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: WEYERHAEUSER EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: REDBUILT LLC

ATI Evaluation Service A Division of Architectural Testing Certification Services

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: WEYERHAEUSER

138 H-STUD AREA SEPARATION WALL SYSTEM

FIRE FACTS. For ilevel Engineered Lumber Products iLevel8 ( ) WALL SOLUTIONS. Thorough Fire Testing

REPORT HOLDER: GYPSUM ASSOCIATION 962 WAYNE AVENUE, SUITE 620 SILVER SPRING, MARYLAND EVALUATION SUBJECT:

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: HOMASOTE COMPANY

REPORT HOLDER: GYPSUM ASSOCIATION 6525 BELCREST ROAD #480 HYATTSVILLE, MARYLAND EVALUATION SUBJECT:

ESR-1812 Reissued October 1, 2012 This report is subject to renewal November 1, 2013.

Introducing TJ Insulated Structural Framing Components

REPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER

FIRE DESIGN & INSTALLATION GUIDE

ESR-1405 Reissued November 1, 2013 This report is subject to renewal December 1, 2015.

FIRE DESIGN & INSTALLATION GUIDE

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED STRUCTURAL WOOD REPORT HOLDER: REDBUILT LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

GYPSUM BOARD

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

Featuring Fire Assembly Details and Sprinkler Installation Guidelines

Featuring Selection and Installation Information for Lateral Wind Loads

BUILDING CODE REQUIREMENTS

Strong-Drive SDWS TIMBER Screw

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

Mid-Rise Engineering Considerations for Engineered Wood Products

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

SECTION GYPSUM BOARD SYSTEM

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-FABRICATED STRUCTURAL WOOD REPORT HOLDER: REDBUILT LLC

RSIC ACOUSTIC ASSEMBLY

Page 2 of 5 1. Flooring Systems The flooring system shall consist of one of the following: System No. 1 Subflooring Nom 23/32 in. thick wood structura

UL Design System HW-D-1012 continued

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

SECTION GYPSUM BOARD SYSTEM

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code

Section Roof/Ceiling Thermal Insulation

WALL ASSEMBLIES. PHILLIPS MANUFACTURING CO. - Omaha, NE USA DESIGN NO. PMC/WA DESIGN NO. PMC/WA 60-01

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK Order No October 15, REPORT NO CRT-002d3

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

RSIC ACOUSTIC ASSEMBLY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

RSIC ACOUSTIC ASSEMBLY

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: APA- THE ENGINEERED WOOD ASSOCIATION

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System

AUTHORIZATION TO MARK

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

2009 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

Designing to Meet IRC Fire Protection Provisions for I-Joist Floor Systems

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year.

Design No. M507. Design No. M507

Preventing a Floor Truss Ban in Ohio. SBCRI/Qualtim TER Produces A Win for All Component Manufacturers (CMs)

Trusted WOOD I JOISTS SECTION: 06 ON WEB i. Conformity! ICC-ES Evaluation. Copyright 2015

ICC-ES Evaluation Report Reissued September 1, 2011 This report is subject to renewal in two years.

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: Forest rx

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council

U.S. WALL GUIDE. Featuring Trus Joist TimberStrand LSL and Parallam PSL Wall Framing. Engineered to meet code requirements for walls up to 30' tall

Multi-Institutional Academic Health Science & Research Center Evansville, IN

FOR: CEMCO - California Expanded Metal Products Co. Sound Transmission Loss Test

FLOOR CEILING ASSEMBLY

R-Matte Plus-3: Insulation for the Building Envelope

Design No. L565. Design No. L565

Deer Ridge Consulting, Inc.

TECO Certified Rim Board in Fire-Rated Assemblies TER No

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: Base 10

Originally Issued: 03/31/2017 Valid Through: 04/30/2018

SECTION GYPSUM BOARD

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: Expona

SECTION GYPSUM BOARD

CEYDC.R25563 Nonmetallic Plumbing System Components Listed for Fire Resistance

INSTALLATION GUIDE GUIDE TO ASC ISO-WALL CONSTRUCTION SYSTEM APPLICATION ISO-WALL SYSTEM. ASC Iso-Wall System Includes: Materials Required:

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: QT4005

Building Division Informational Handout

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: QT4002

Joint Evaluation Report

Joint Evaluation Report ICC-ES (800) (562)

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

ICC-ES Evaluation Report Reissued February 1, 2011 This report is subject to re-examination in one year.

FIREBLOCK/DRAFTSTOPPING INFORMATION CODE INFORMATION FOR 1 & 2-FAMILY DWELLINGS FOR WOOD-FRAMED CONSTRUCTION FIREBLOCK

Joint Evaluation Report

Duct Wrap Flexible Wraps

Joint Evaluation Report

BXUV.L576 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

SPECIFIER GUIDE I-JOISTS. PKI 10, PKI 20, PKI 23, PKI 35 Plus, PKI 40, PKI 50 - CANADA

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

3.0 DESCRIPTION. Division: Thermal and Moisture Protection Section: Thermal Insulation

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

Transcription:

Appendix D -Weyerhaeuser Fire Rated Assembly Listings-

Table of Contents Assembly Description Reference Standard/Criteria FJ-1 TJI Joist 1 hour fire resistance rated floor and roof assembly. ASTM-E119 and CAN/ULC-S101 FJ-2 TJI Joist alternative to 2X10 dimension lumber ASTM-E119, CAN/ULC-S101 and prescribed in the 2012 IRC section R501.3, exemption 4. ICC-ES AC14 WS-1 TimberStrand LSL 1 hour fire resistance rated rim board assembly. ASTM-E119 and CAN/ULC-S101 FA-1 TJI Joist 1 hour fire resistance rated floor and roof assembly. ASTM-E119 and CAN/ULC-S101

Weyerhaeuser Assembly FJ-1 (1 Hour Fire Rated Assembly) The following fire resistant designs are listed in accordance with ASTM-E119 and CAN/ULC-S101 Typical resilient channel and gypsum board attachment 1 ½ minimum 1. The flooring consists of a single layer of 48/24 span-rated, tongue-and-groove, sheathing (Exposure 1). Construction adhesive conforming to ASTM D 3498 (AFG-01) must be applied to the top of the joists prior to placing sheathing. When used as a roof-ceiling assembly, the decking is permitted to be any wood deck recognized in the code. All butt joints of the sheathing must be located over framing members. The floor sheathing shall be installed in accordance with the applicable code. 2. TJI 210, 230, 360, 560 and 560D joists with Flak Jacket Protection must be installed in accordance with this report, with a maximum spacing and shown in the table below: TJI Series Joist Depth (in) Maximum O.C. Spacing (in) 210 9½ and deeper 16 230/360/560/560D 9½ 16 11⅞ and deeper 24 For design, use 90% of published TJI 210, 230, 360, 560 and 560D bending moment capacity. Flak Jacket protection is applied in accordance with the TJI Joist With Flak Jacket Protection Manufacturing Standard and quality control program. Minimum TJI Joist flange thickness is 1⅜ (34.9mm) and minimum depth is 9½ in (241 mm) for 16 in (406mm) o.c. spacing and 11⅞ in (302 mm) for 24 in (610mm) o.c. spacing. 3. The ceiling membrane must consist of one layer of ⅝-inch-thick (15.8 mm), Type C gypsum board attached to resilient channels with 1⅛ inch Type S drywall screws spaced at 6 inches on center. All exposed gypsum board joints and screw heads must also be covered with two coats of joint compound. 4. Resilient channels (RC-1 type) spaced at 16 inches (406 mm) inches on center, installed perpendicular to the TJI Joists and attached with 1⅝ inch-long (41.3 mm), Type W screws at each joist. Where splices are necessary, the resilient channels must overlap 6-inches and fastened together with two screws. Two channels must be located at each gypsum butt joint placed 1.5 from each butt end. The additional channels shall extend to the joist on each side Optional: Glass fiber insulation, 3½ inch thick in plenum placed between joists on top of bottom flange (or higher).

Weyerhaeuser Assembly FJ-2 (2X10 Dimension Lumber Equivalence) The following fire resistant designs are listed in accordance with ASTM-E119, CAN/ULC-S101 and ICC-ES AC14 as an alternative to 2X10 dimension lumber prescribed in the 2012 IRC Section R501.3Exception 4. 1. The flooring consists of an appropriate single layer of span-rated, tongue-and-groove, sheathing (Exposure 1). Construction adhesive conforming to ASTM D 3498 (AFG-01) must be applied to the top of the joists prior to placing sheathing. The floor sheathing shall be installed in accordance with the applicable code. 2. TJI 210, 230, 360, 560 and 560D joists with Flak Jacket Protection must be installed in accordance with this report, with a maximum spacing of 24 inches (610 mm) on center. Flak Jacket protection is applied in accordance with the TJI Joist With Flak Jacket Protection Manufacturing Standard and quality control program. Minimum TJI Joist flange thickness is 1⅜ (34.9mm) and minimum depth is 9½ inches (241 mm).

Weyerhaeuser Assembly WS-1 1 Hour Rim Board Assembly - No Load Transfer to Adjacent Rim The following fire resistant design is listed in accordance with ASTM-E119 and CAN/ULC-S101 1. Floor/ceiling or roof/ceiling assembly as required by the applicable building code. 2. One - hour - rated wall assembly installed in accordance with the applicable building code. 3. TJI 110, 210, 230, 360, 560, 560D, s31, s33 or s47 joists up to 16 deep with a minimum ½ regular gypsum ceiling assembly installed in accordance with the applicable building code. 4. 1¾ (44.5mm) thick 1.5E (minimum) TimberStrand LSL installed in accordance with the applicable code. Maximum vertical load of 2000 plf ASD (un-factored) per rim board member. 5. For rim board deeper than 11 ⅞, TJI blocking placed at 4 on-center is required at walls running parallel to the floor joists. Attach blocking in accordance with detail PB1 of the Weyerhaeuser TJI Joist Specifier s Guide (TJ-4000, TJ-4005, TJ-4500 and TJ-4510).

Weyerhaeuser Assembly FA-1 (1 Hour Fire Rated Assembly) The following fire resistant designs are listed in accordance with ASTM-E119 and CAN/ULC-S101 Typical resilient channel and gypsum board attachment 1. Optional gypsum concrete, lightweight or normal concrete topping. 2. The flooring consists of a minimum single layer of 48/24 span-rated [minimum 23/32 in (18mm) thick] tongueand-groove, sheathing (Exposure 1). When TJI Joists are limited to a maximum spacing of 20 in (508 mm), a minimum 40/20 span-rated [minimum 5/8 in (15 mm) thick] sheathing is permitted. Construction adhesive conforming to ASTM D 3498 (AFG-01) must be applied to the top of the joists prior to placing sheathing. When used as a roof-ceiling assembly, the decking is permitted to be any wood deck recognized in the code. All butt joints of the sheathing must be located over framing members. The floor sheathing shall be installed in accordance with the applicable code. 3. Minimum 9½ TJI 110, 210, 230, 360, 560, 560D, s31, s33 or s47 joists with a maximum spacing of 24 in (610 mm) on center for floor ceiling or roof ceiling assemblies. 4. Optional glass fiber insulation or mineral wool insulation minimum 3½ in thick maybe placed in the plenum when resilient channels are used. The joist cavity is permitted to be filled with insulation, however the insulation must be placed above the resilient channels between the joist flanges. 5. Resilient channels (RC-1) installed at 16 in (406 mm) on center [for joist spaced at 16 in (406mm) and less, the resilient channels may be spaced at 24 in (610 mm) on center] fastened perpendicular to the TJI Joists using 1 in (25.4 mm) long type S screws. 6. The ceiling membrane must consist of two layers of ⅝ in (15.8 mm) thick Type X gypsum board. The first layer of the ceiling member must be installed perpendicular to the channels and attached to the resilient channels using 1 in (25.4 mm) long, Type S screws spaced at 12 in (305 mm) on center. The second layer must be installed with the joints staggered from the first layer and attached using 1⅝ in (41 mm) long Type S screws. The screw spacing for the second layer of gypsum board must be a maximum of 12 in (305 mm) on center in the field and 8 in (203 mm) on center at the butt joists. Additionally, 1½ in Type G screws must be spaced 8 in (203 mm) on center and 6 in (152 mm) from each side of the butt joints of the second layer. The second layer must be finished with joint tape and compound.