C.I.Agent Barrier Boom Containment System

Similar documents
Geomembrane Liner & Oil Filtration Panel Containment System

OWENS CORNING Limited Lifetime Warranty for EnergyComplete System. OWENS CORNING Limited Lifetime Warranty for EnergyComplete Sealant

VILLAGIO FLOORS, INC. TOLL FREE: Fax: VILLAGIOWOODFLOORS.COM. Finish Warranty. Structural Warranty

BULWARK BOLLARDS M30 & M50

DUST FREE ACTIVE Total Home Air Purification

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

TABLE OF CONTENTS. Section Paragraph Title Page. ADDENDUM Visual Index Quick Reference. 1 General Information 1-1

3601 E. 34th St. Tucson, AZ USA Tel Fax Web:

INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL

MODEL NUMBER: 1419 SERIES

WEST FLOORING & DESIGN (WFD)

New Advanced Environmental Air Treatment System

Model T2642E Wall Mount. Television Wall Mount with Tilt Option

New Advanced Environmental Air Treatment System

CR-3000 Car Rotator Capacity 3,000 lbs Installation Manual 2016 Mar

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. MPL Digital Pedestal. Manual Version 0.2

INSTALLATION PROCEDURE

Contactor & Recharger

Everything in its place. OWNER S MANUAL. TRINITY ECOSTORAGE 6-TIER NSF 48 x 18 x 72 WIRE SHELVING RACK w/wheels CHROME Model # TBFC-0907

Pallet Puller. Owner s Manual

INSTALLATION PROCEDURE

ipd Custom Grille for 850 ipd #850ECB, #850ECC, 850MB

RAY-CORE Structural Insulated Roof and Wall Panels

N-SERIES SUBWOOFERS USER MANUAL

PI /09 Dedicated to improving vehicle fun, safety & performance

RESIDENTIAL USE WARRANTY

3601 E. 34th St. Tucson, AZ USA Tel Fax Web:

INSTALLATION PROCEDURE

Action QuickCourt R Modular Athletic Flooring

YOUR WOOD FLOORING RESIDENTIAL AND LIGHT COMMERCIAL HARDWOOD WARRANTIES

Grinnell Mechanical Products Figure 730 Mechanical Tees - Threaded / Grooved General Description. Technical Data. Page 1 of 8 MAY, 2009 G210

Model Number: 1300 Series

AUTOMATIC FOLDING DOOR

Residential Warranty. Thank you!

117-Bin Wire Shelf Storage Rack

GE Enduris* 3500 silicone roof coating Roof Restoration Warranty - 10 Year

Arborite also offers regrind product (GSCR). This is a regraded product that can be used as a backing grade (pending upon availability).

TERMS AND CONDITIONS OF SALE

HD Firewall Mount 850 all, S/V , C ipd #

LIMITED RESIDENTIAL USE WARRANTY

SHOWER & TUB/SHOWER INSTALLATION

Residential Showers, Tub Showers & Bathtubs. Water changes everything

The Best Around Underground

Hardwood Flooring Limited Warranty - Exotics

66-Bin Wire Shelf Storage Rack

Warranties Effective on purchases as of SEPTEMBER 2015

STEEL PIPE NIPPLES SEAMLESS Price Sheet PNS-9.16C Effective: September 5, 2016 Cancels Price Sheet PNS-10.15C of October 5, 2015

INSTALLATION PROCEDURE

... your Material Handling Specialist. MC300HD Conveyor. echnology. with MicroSpan. Technology

Address: City: State: Zip: Day Phone: Fax: 5. Where Were Your Products Purchased and/or Installed: Installer s Name/Company:

QUALITY ENGINEERED Warranty

Residential Home Limited Warranty

INSTALLATION INSTRUCTIONS FOR BALCO, INC. TRENCH GRATES MR-X-P

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

Nutrient Removing Filtration System

OptoLum MegaLine RGBW Luminaire

Effective This guide supersedes all previous versions

IMPORTANT: Read and understand the Operations Manual before operating the EconoDot.

INSTALLATION INSTRUCTIONS FOR BALCO, INC. TRENCH AND ACCESS COVER TSA/ACA-X-250 W/O LINER FOR CAST-IN-PLACE INSTALLATION

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: twrlighting.com IMPORTANT!!!

END TRUCKS WHEEL SIZES: 9", 12", 15" & 18"

TAYLOR FORGE STAINLESS

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

FREESTANDING TUB INSTALLATION INSTRUCTIONS

Warranty & Terms and Conditions

Vinyl Click Flooring Limited Warranty

Vinyl Glue Down Flooring Limited Warranty - Utility

Warranty & Terms and Conditions

Hamilton Code System 3 Installation Manual

Performance Plus Carpet Selection GUIDE

CFL Series User Manual

92831 TEL: (714) FAX:

Vinyl Glue Down Flooring Limited Warranty - Pro

INSTALLATION GUIDELINE HANDBOOK RSS-2000 SERIES ELECTRIC VEHICLE BARRIER

P1902 Installation Manual

Models FWB, LWB, MWB and HWB Brakes AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

GF6580BH-1 PATRIOT LIBERTY QUARTER RAILS:

Tiny TIMBERS Limited Warranty Solid Wood Plank Flooring

STEVES & SONS PRODUCT WARRANTY

Structural Performance Tests of VHB Structural Glazing Tapes

Bulldog Coatings, LLC Limited Product Warranty Bulldog Coatings, LLC Finished-to-Order & Custom-Finished products

Residential Warranty. Rigid Luxury Vinyl Flooring

Installation Guide Document No BioSafe Cleanroom Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised December 2017

Installation Instructions 2 Ft Ft. Planter Boxes

PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE

Stainless steel rolling cabinet

Process Returns in VOTW

RNS, DRS, & ER-60 M-Line Operational Manual

Ignition Switch Replacement for 850/70 Series ipd # , #

ION Fresh & Clean Ventilation System Part # Basement Unit Part # Crawlspace Unit

SHAMROCK PLANK FLOORING

S8VM Series Replacement Brackets

PRESTO GEORUNNER FLOW PROTECTION SYSTEM INSTALLATION GUIDELINE. GRFP-V2 1 NOV Presto Products Co. All Rights Reserved.

WARNING. Introduction ! ATTENTION

Ion Fresh & Clean Ventilation System

LVT Flooring, 20mil Wear Layer Lifetime Limited Residential Use Warranty

PalletPal Low Profile Disc Turntable

4-PIECE SHOWER & TUB/SHOWER w/ E-Z Pin INSTALLATION

General Information. Southwest Office Edwards Road, Suite B105 Cerritos, CA (Main Phone)

Owner s Manual & Safety Instructions

Transcription:

Manufacturer's Recommended Installation Processes for C.I.Agent Barrier Boom Containment System Manufactured by: C.I.Agent Solutions, LLC 11760 Commonwealth Drive Louisville, KY 40299 866-242-4368 502-267-0101 fax: 502-267-0181 2-20-2014 www.ciagent.com

FULL CONTAINMENT - BACK TO GRADE METHOD If the subsoil around the area to be contained is sandy or non-impervious, you may need a liner for full protection. 2. Dig a trench around the perimeter of the substation. Depth and width depends on your particular application of Barrier Boom. For this method, the Barrier Boom must be below grade level. 3. Inside the trench, string a line from one side of the trench to the other to keep the stakes and Barrier Boom straight. 4. Position stakes or rebar every 10 feet inside the trench. Roll out the C.I.Agent Barrier Boom beside trench. The BLACK fabric side of the Barrier Boom must be up. 5. Optional: Granular Bentonite can be placed in the trench to form a seal between the ground and the Barrier Boom. 6. Stand the Barrier Boom up against the stake and staple or screw near the top of the Barrier Boom. If using rebar, lean Barrier Boom against it. Black fabric side to face the inside. 7. Stakes are trimmed off to ground level. Carefully dump clean stone in the trench and around the Barrier Boom being careful not to crush the boom. If using rebar, pull it out of the ground once clean stone is around the boom. 8. A 10 foot angle iron can be used to deflect the stone during the fill process. Rest the angle iron on the stakes or rebar and pull the angle iron to the next support during filling. 10. Cover area with clean stone and rake until the Barrier Boom is completely covered. pg 2

FULL CONTAINMENT - DIKE METHOD If the subsoil around the area to be contained is sandy or non-impervious, you may need a liner for full protection. 2. Dig a trench around the perimeter of the substation. Depth and width depends on your particular application. In the Dike method, the Barrier Boom raises above ground level. 3. Position stakes or rebar every 10 feet inside the trench. Roll out C.I.Agent Barrier Boom beside trench. The BLACK fabric side of the Barrier Boom must be up. 4. Stand the Barrier Boom up against the stake and staple or screw near the top of the Barrier Boom. If using rebar, lean Barrier Boom against it. Black fabric side to face the inside. 5. Granular Bentonite can be put in the trench at the bottom of the Barrier Boom. Carefully dump clean stone in the trench around the boom being careful not to crush the boom. An angle iron can be used to protect the Barrier Boom. Notice the boom is above ground level. 6. The clean stone forms a mound over the Barrier Boom. 7. Cover the area with clean stone and rake until the Barrier Boom is completely covered. pg 3

EQUIPMENT CONTAINMENT - DIKE METHOD 2. Dig a trench around the perimeter of the equipment. Depth and width depends on your particular application. In the Dike method, the Barrier Boom raises above ground level. 3. Position stakes or rebar every 10 feet inside the trench. Place C.I.Agent Barrier Boom inside the trench with the BLACK fabric side of the boom facing inside. Staple to stakes or lean against rebar. 4. Granular Bentonite can be put in the trench at the bottom of the Barrier Boom. Carefully dump clean stone in the trench around the boom being careful not to crush the boom. Notice the mound that is being created over the Barrier Boom. 5. The C.I.Agent Barrier Boom around this transformer provides complete protection should a spill occur. ADDITIONAL INFORMATION C.I.Agent Barrier Booms can be used in a variety of applications that may not be illustrated in this manual. If you have a particular need or application, please contact the corporate office at 866-242-4368. Product and Pollution Insurance C.I.Agent Solutions is so confident in the quality and performance of its products that they are backed by a $2 Million Pollution Insurance and a $2 Million Product Liability Policy. C.I.Agent Solutions products are manufactured under quality controlled conditions at our facility in Louisville, Ky. Testing of products is performed in our in-house lab as well as by independent thirdparty laboratories. Documented results on the performance of C.I.Agent Solutions products can be found in Case Studies and testimonials on our website at www.ciagent.com. Upon request, after the purchase of our product(s), C.I.Agent Solutions will provide a Certificate of Co-Insurance. pg 4

WARRANTY C.I.Agent Solutions, LLC warrants to the purchaser of its products, that the C.I.Agent Oil Containment and/or Hydrocarbon Filtration System for which the customer received this warranty was designed, developed, and/or fabricated using all due reasonable commercial care and good manufacturing practices. C.I.Agent Oil Containment and/or Hydrocarbon Filtration System shall be free from defects in material and workmanship. C.I.Agent Solutions further warrants the performance of their C.I.Agent Oil Containment and/or Hydrocarbon Filtration System to prevent the release of hydrocarbons due solely to the failure of the materials and workmanship of the product. The performance warranted herein is contingent upon the installation of the C.I.Agent Oil Containment and/or Hydrocarbon Filtration System being performed under the direct supervision of a C.I.Agent Solutions Factory Representative and/or a C.I.Agent Solutions Factory Certified Contractor. Said performance warranted herein is further contingent upon each C.I.Agent Oil Containment and/or Hydrocarbon Filtration System being installed in strict accordance with the C.I.Agent Solutions' Installation Manual, supported by a step-by-step photographic documentation of the installation to be sent to C.I.Agent Solutions upon completion of the installation. Upon receipt and review of the photographic installation documentation, C.I.Agent Solutions will issue to the Customer a Certificate for Pollution Insurance in the amount of $2,000,000 to address the cost of clean up solely related to the performance of the C.I.Agent Oil Containment and/or Hydrocarbon Filtration System as warranted herein. C.I.Agent Solutions' sole obligation under this warranty is to repair or replace the product as warranted herein, at C.I.Agent Solutions' option. Repair or replacement shall not apply to products that have been expended, damaged, or consumed during the capture or filtration of hydrocarbons from sources they were designed to contain and/or filter. C.I.Agent Solutions must be notified in writing of any claim under this warranty within 30 days of any claimed lack of conformity of the Product. Warranty Limitations In no event shall C.I.Agent Solutions be liable for any loss, inconvenience or damage, whether direct, incidental, consequential or otherwise, resulting from breach of any expressed or implied warranty or condition, of fitness for a particular purpose or otherwise with respect to this product, except as set forth herein. This warranty is not to confer any additional legal, jurisdiction or warranty rights to the customer other than those set forth herein. Warranty Exclusions It is the customer's responsibility to regularly examine the Product to determine if damage has occurred during the normal operation and/or maintenance of equipment at the site of the C.I.Agent Oil Containment and/or Hydrocarbon Filtration System installation to determine the need for repair or replacement. This warranty does not cover the following: Products that have been modified, neglected, misused, abused, or damaged by natural disasters. Damage to the Product resulting from improper use or occurrence during the normal operation and maintenance of equipment at or near the Product. 11760 Commonwealth Drive Louisville, KY 40299 866-242-4368 502-267-0101 Fax 502-267-0181 www.ciagent.com Revised 2/20/2014 pg 5