THE WATER MANAGEMENT SYSTEM PRODUCT MANUAL

Similar documents
THE EDDY WATER MANAGEMENT SYSTEM PRODUCT MANUAL

WATER. The Nikken PiMag technology to create living water. Water essential for all life on Earth

KDF Process Media. Improve the performance and economy of your water purification system.

Your customers are expecting less from you

Your customers are expecting less from you

about your house Water Filters

ARCHBOLD WATER TREATMENT PLANT 700 NORTH STREET ARCHBOLD, OHIO

Fresh Water Purification for Municipal Systems Global s Unique Modular Platform Systems

USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address EC Introduction of EC What is reverse osmosis

RO102 P URE PRO DRINKING WATER SYSTEM USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address RO102

Maintenance of Drip Drip Irrigation Systems. Patrick Byers Regional Horticulture Specialist University of Missouri Extension

FS-8000 USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product FS Date of purchase. Address

DW Module 23: Organic Removal Answer Key

Boss Water Systems Australia Reverse Osmosis System Model 021-4P-GM

Scavenger2000 s Technology

FRESHPOINT FILTRATION PLATFORM PENTAIR UNDERSINK DRINKING WATER SYSTEMS SOLUTIONS DESIGNED TO IMPROVE YOUR WATER WATER PURIFICATION

ERS-106UV USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

OPERATION AND MAINTENANCE MANUAL

Zip Freestanding Chilled Water Systems

DIRTY WATER? Identifying Bad Water Quality Problems. by Richard Gellert

Zero Discharge Treatment Method for Cooling Towers and Heat Exchangers with SP3, I-SOFT-OB, OXYDES & KATALOX LIGHT

P URE PRO DRINKING WATER SYSTEM USER'S MANUAL REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

HRO-50 Water Purifier

Introducing the Roving Blue OZO-Pen OZO-Pod and Ozo-Flow Line of Commercial Water Ozone Generators: Efficient and affordable electrolytic ozone

Boiling point in C. Colour in aqueous solution. Fluorine 188 colourless. Chlorine 35 pale green. Bromine X orange.

Distributed by: Phone: , Toll-Free U.S. Fax: , Toll-Free U.S.

S800-Direct Flow USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

Water Pollution. Objective: Name, describe, and cite examples of the eight major types of water pollution.

HU-10 Water Purifier. Product Installation & Operation Manual. Honeywell Environmental & Combustion Controls (Tianjin) Co., Ltd.

Beer Line Disinfection System

AlkalineSpring-QualityWaterFrom EVERYFaucetInYourHome! OWNERSMANUAL& PRODUCTINSTALLATION GUIDE.

RO105TDS P URE PRO DRINKING WATER SYSTEM USER'S MANUAL. Memo PRO REVERSE OSMOSIS SYSTEM. Type of product RO105TDS. Date of purchase.

RO105UV P URE PRO DRINKING WATER SYSTEM USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product RO105UV. Date of purchase.

Corrosion and batteries

Modular Education Program Course Catalog Certificates, Badges, and Learning Activity descriptions.

the faculty for factory program (FFF), Jordan

Water Treatment System

Puroxi Pure Water Global Inc. Shield 500/1000 Drinking Water System (DWS)

Portable Water Filter Pitcher NFP-100

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

DW Module 22 Inorganic Removal Basics Answer Key

USE AND CARE/INSTALLATION INSTRUCTIONS Shower Filter model Eco50K and model Eco50KM

CHAPTER 3 INTRODUCTION TO TREATMENT PROCESSES

ecosphere water purifier 3in1 USER MANUAL

CE 370. Wastewater Characteristics. Quality. Wastewater Quality. The degree of treatment depends on: Impurities come from:

Distributed and serviced by:

ppm Dissolved Oxygen Measurement

RO400 USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM RO400. Type of product. Date of purchase. Address

MAVEA Professional. Basics on water

Mark schemes. for 1 mark. for 1 mark. An arrow indicating a position between aluminium and zinc. electrolysis

Rusting is an example of corrosion, which is a spontaneous redox reaction of materials with substances in their environment.

HU-20 Water Purifier. Product Installation & Operation Manual. Honeywell Environmental & Combustion Controls (Tianjin) Co., Ltd.

PERIODIC TABLE. Group Family Period Valence electrons Energy levels

Chemical reactions and electrolysis

AQUATIC PRE-FILTRATION TECHNOLOGIES. A guide to water filtration for pools and spas

Owners Manual Models: 200-RODI4-XXX. US Water Systems 4 Stage RO/DI System Installation and Maintenance Manual.

Distribution Review. Corrosion Control. Corrosion Control Vocabulary. American Water College 1. Corrosion Control Training Objectives

Q & A on Reverse Osmosis

Excalibur Ultraviolet Sterilizers Choose Bacteria-free Water

Why Does Rust Occur? 7.1 IN GENERAL

Recirculating Hot Water Systems

Understanding Reverse Osmosis Mark Rowzee Mark Rowzee

Winnipeg s Water QUALITY REPORT. Water and Waste Department

National Science Content Standards: A: Science as Inquiry E: Science and Technology

EXCALIBUR - ULTRAVIOLET STERILIZERS. When performance & value matters.

Module 1: Introduction to Wastewater Treatment Answer Key

ICSE-Science 2 (Chemistry) 1996

IS MY WATER SAFE? How do I know if my water is safe to drink?

F U C H S L U B R I C A N T S C O.

EC106M-P USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product EC106M-P. Date of purchase. Address

Extracting Metals by Electrolysis

EC106M USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product EC106M. Date of purchase. Address

Electricity and Chemistry

Introduction of HR-800(M) Components. Cartridge filters. Installation diagram. Change membrane. Change filters. Operation regulation FAQ

Aqualife Products (Australia) Pty Ltd Steam Sterilisor Water System

Electricide HG Electrochemical Chlorine Generators

Table of Contents... 1 Start Up Instructions After Installation Introduction Water Quality & Conditions Weather Considerations...


SANITIZING OF MILK CASE WASHERS AND TRANSPORT CONVEYORS: AN OVERVIEW OF CURRENT PRACTICES AND ADVANTAGES OF CHLORINE DIOXIDE USE

PLEASE NOTE: *Pre-plumb or replacement installation. Prices do not include sales tax.

Energizer Silver Oxide (Zn/Ag ² O) Application Manual

The forces between iodine molecules are stronger 1. (b) anything in range +30 to It contains ions which can move 1. (f) hydrogen iodine 1 [6]

Sumo. Non-Electric Water Softeners. Highly Efficient. Powerfully Compact. Beautifully Simple. Professional Grade Water Treatment

Electrocoagulation. Achieving clean, clear, treated and reusable water: The process, technology and benefits. CALL US (631)

M1.(a) time from when the heating is started until 1. the limewater turns cloudy / milky 1

RD6000 Kitchen Range

Water Treatment & Purification Chemicals

Electro-refining: How it Works

Unit Includes: Description: Special note on chloramines: 1. Main unit ft. of 3/8 feed tubing

Time : 2 Hours (Model Answer Paper) Max. Marks : 40

PDOevo PLUS Ozone Systems LET S SOLVE WATER AND MINIMIZE THE ENERGY

BORABU-MASABA DISTRICTS JOINT EVALUATION TEST 2012 Kenya Certificate of Secondary Education (K.C.S.E)

Water and Waste Department. Winnipeg s Water QUALITY REPORT 2005

PURE PRO PUREPRO ROYAL REVERSE OSMOSIS SYSTEM. purepro products you can always count on number one source for quality filters & components

S1 Building Blocks Summary Notes

Copper Odyssey. Chemical Reactions of Copper

Household Water Treatment

EnvirEau Technologies Inc.

Covered with a thin layer of oxide at ordinary temperatures.

1. Which of the given statements about the reaction below are incorrect?

Transcription:

THE WATER MANAGEMENT SYSTEM PRODUCT MANUAL

THE WATER MANAGEMENT SYSTEM (WMS) 3

CONTENTS CERTIFICATION PRODUCT INFORMATION WATER MANAGEMENT SYSTEM INSTALLATION CARING FOR YOUR SYSTEM DOs AND DON Ts FEATURES SERVICE & CUSTOMER ASSISTANCE 6 7 8 10 10 11 12 15 5

CERTIFICATION Tested and certified by Certifications 7 6

PRODUCT INFORMATION The product is designed to accomplish two important objectives: (1) to deliver the purest water possible to an entire household from an affordable system and (2) to provide savings from reduced water usage. Unlike other home systems, the need to replace cartridges every 6 months is now extended to 5 years, and included free with service programs from Municipal Water Savings Corp. SERIAL # AGREEMENT # DATE INSTALLED TECHNICIAN NAME 7

8 WATER MANAGEMENT SYSTEM (WMS)

PRESSURE DIAL Measures the PSI going through the system and relays that information through an easy to read gauge. KDF CYLINDER AND MEDIA (KINETIC DEGRADATION FLUXION) KDF Media reduces up to 99% of harmful chlorine, and is used for the removal of heavy metals like lead and mercury. FIBONACCI VORTEX CYLINDER AND MAGNETS Vortex cascade technology energizes and scale controls your water before it enters your home plumbing and appliances. WATER OPTIMIZER Spring action piston prevents backflow and reduces false meter readings from air bubbles resulting in water and wastewater savings. BY-PASS VALVE Allows the homeowner to manually restrict or by-pass the flow of water in and out of the system. Provides an additional level of safety. 9

INSTALLATION The Water Management System is intended to be installed by an authorized Municipal Water Savings Corporation (MWSC) technician. An authorized MWSC technician is a certified and trained service professional. The device should not be installed by anyone other than a MWSC technician. CARING FOR YOUR SYSTEM Occasionally use a soft damp cloth or a mild soapy sponge to wipe the outside of your system to keep it looking shiny and new. Never use abrasive cleaners on the exterior. 10

DOs AND DON Ts DO Occasionally clean the outer surface of the unit as instructed in this manual. DO Call your representative if any malfunction or leak is noticed. DO Remember that wet surfaces can be slippery. Take care if there is any leakage on the floor surrounding the unit, and call Municipal Water Savings Corp. for service. DON T Be alarmed when the KDF Media turns black, that means it is doing its job. DON T Attempt to fix the unit yourself. DON T Store items on top of the unit. DON T Open the unit. 11

FEATURES BY-PASS VALVE Allows the homeowner to manually restrict or by-pass the flow of water in and out of the system. Provides an additional level of safety. PRESSURE READING Measures the PSI going through the system and relays that information through an easy to read gauge. WATER OPTIMIZER The WMS is equipped with a Water Optimizer, a technology which reduces water consumption, and provides homeowners potential savings of up to 7% on their water and wastewater bills. DUAL CYLINDERS The two cylinders are made of clear UV resistant PETG. Each serves a special purpose. First the water is injected into the KDF cylinder and media. Next, upon entering the second chamber, water is energized through our proprietary Double Vortex Cascade. These vortexes, along with a strategic placement of a magnetic field, energize and scale control of the water before entering your internal household water system. KDF CYLINDER AND MEDIA (KINETIC DEGRADATION FLUXION) Water passes through a bed of pure KDF Media. KDF is known to kill algae and fungi, control bacteria growth, and reduce chlorine, pesticides, organic matter, 12

unpleasant taste and odor, and other inorganic compounds. As the water makes contact with the KDF particles the Redox reaction takes place, removing such impurities as minerals, metals, dissolved oxygen and organic materials. The KDF itself creates a miniature electrolytic cell within the space between each particle, the zinc acting as the anode and the copper acting as the cathode within this cell, and the water and its impurities acting as the electrolyte through which the charge flows. When the contaminants and impurities found in water pass through this electrolytic cell, some substances, especially metals, react to the magnetic force exerted by the electrolytic cell and are attracted to the surface of the KDF particles, where they adhere. Other non-metal impurities react with the KDF and form zinc oxides, copper hydroxides, and sulfates in the water. FIBONACCI VORTEX CYLINDER AND MAGNETS This specially designed Vortex incorporates Fibonacci s mathematical formula. Water entering the cylinder is vigorously spun counter clockwise (the opposite of nature s progression), which breaks the bond of the water. The water then is exposed to six high gauss rated magnets that further break the bond, allowing for smaller clusters of previously clumped water molecules. Finally, again identical to the Fibonacci sequence, the water is spun clockwise which produces energized water. IMPORTANT: Additional energy savings may be realized due to the scale control process in the Vortex. 13

SERVICE & CUSTOMER ASSISTANCE Once the Water Management System is installed, it is designed to operate at optimal efficiency without interruption. In the case of any problem experienced with this unit, please contact Municipal Water Savings Corp. at 1-800-541-1877. For faster service, please have your Agreement number and serial number ready for the operator to assist you. 15

MUNICIPAL WATER SAVINGS CORP. www.municipalwater.com ON-V3/06212016