STANDARD OPERATING PROCEDURES

Similar documents
2.1 This procedure provides steps and conditions for the determination of Vapor Space Organic Compounds in ground waters, and industrial waste waters.

ACETALDEHYDE. The procedure is applicable to corn syrups including those containing fructose, and to most other starch hydrolyzates (Note 1).

Separation and Quantitation of a Mixture of Alcohols by Gas Chromatography

METHOD 310A - DETERMINATION OF RESIDUAL HEXANE THROUGH GAS CHROMATOGRAPHY

Corn Syrup Analysis E-1a- 1. ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Gas Chromatography Assignment Chem 543/443

CORESTA Recommended Method No. 57

Field Tests of Chloroform Collection/Analysis Methods

Two Headspace Solutions for the Analysis of Dissolved Gases in Water by Method RSKSOP-175

10. Validated Normal Phase HPLC Method for the Determination. Fulvestrant is primarily used in the treatment of hormone receptor

System Overview. Valve oven. Restrictor. Valve. Sample in and out

JAI RESEARCH FOUNDATION A Global Contract Research Organisation

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC

Formulas: See Table 1 MW: Table 1 CAS: Table 1 RTECS: Table 1. METHOD: 2555, Issue 1 EVALUATION: PARTIAL Issue 1: 15 March 2003

Standard Test Methods for Aromatics in Mineral Spirits by Gas Chromatography 1

Residual Solvents in medical cannabis analysis using the SRI 8610C FID GC June 2014

STANDARD OPERATING PROCEDURES

Capillary GC Troubleshooting: a Practical Approach

SCION GC Series. The Gas Chromatographers Choice for Separations

SCION GC Series. The Gas Chromatographers Choice for Separations

Super Clean Gas Filters Simply the best

VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY *)

Optimizing Productivity and Reliability for Monocyclic Aromatic Hydrocarbon Purity Analysis According to ASTM D7504 on the Agilent 8890 GC System

of Methane, Ethylene, Acetylene and Ethane in Water by Headspace-Gas Chromatography (HS-GC) with

NWTPH-Gx. Volatile Petroleum Products Method for Soil and Water

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

Agilent Consumables Improve Performance with Shimadzu GC/MS

A Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water

Super Clean Gas Filters Simply the best

Experiment 11. DNA Composition by HPLC 1,2

STANDARD OPERATING PROCEDURES

ANILINE, o-toluidine, AND NITROBENZENE 2017

GC Troubleshooting. Frank Michel, Katherine K. Stenerson T HCE

METHOD 7550 OSMIUM (ATOMIC ABSORPTION, DIRECT ASPIRATION)

Determination of Diesel Range Organics (DROs) Using SPE and GC/FID by Method 8015D*

CORESTA RECOMMENDED METHOD N 61

Volatile Organic Carbon Contaminated Site Assessment

Fast Detailed Hydrocarbon Analysis by Modified ASTM Method D6730

Method 0040 for Volatile Total Organics as Unspeciated Mass in Stack Gas Emissions

STANDARD OPERATING PROCEDURES SOP: 1502 PAGE: 1 of 11 REV: 0.0 DATE: 10/24/94

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE.

Olefin Analyzer Solutions for Polymer Grade Ethylene and Propylene

Investigation Requirements for Ethanol-Blended Fuel Releases Petroleum Remediation Program

Orono Spectral Solutions, Inc.

Meet the airgc. Ambient air carrier. Top performance. catalytics accelerated

Quantitative determination of residual 2-(2-chloroethoxy) ethanol (CEE) in quetiapine fumarate by gas chromatogaraphy

Validation of Analytical Methods used for the Characterization, Physicochemical and Functional Analysis and of Biopharmaceuticals.

Performance Characteristics of the Agilent 1220 Infinity Gradient LC system

Hydrocarbon Processing Industry Gas Chromatographs. Standard GC Analyzer Solutions

HYDROCARBONS, BP C 1500

MERCAPTANS, METHYL-, ETHYL-, and n-butyl- 2542

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Validation of a Dual Wavelength Size Exclusion HPLC Method with Improved Sensitivity to Detect Aggregates of a Monoclonal Antibody Biotherapeutic

Total Petroleum Hydrocarbons By Gas Chromatography in Colombian Waters and Soils

Certified Reference Material - Certificate of Analysis

Tap Water Analysis by Atomic Absorption and Ion Chromatography Michelle Youn Chem. 31: Inorganic Quantitative Analysis Section 6

METHOD 25 - DETERMINATION OF TOTAL GASEOUS NONMETHANE ORGANIC EMISSIONS AS CARBON

STANDARD OPERATING PROCEDURES

STANDARD OPERATING PROCEDURES

What Does the Future Hold for Ambient Air Monitoring Regulations?

The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications

Large Volume Injection of Organochlorine Pesticide Extracts Using a Programmable Temperature Vaporizer in the Solvent Split Mode

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer

VICH Topic GL2 (Validation: Methodology) GUIDELINE ON VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY

Using Empower SystemsQT Qualification Tool

Certified Reference Material - Certificate of Analysis

A Simple Rapid and Sensitive Method Development for Quantification of Quetiapine Fumarate in Bulk and Dosage Forms Using RP-HPLC

CORESTA Recommended Method No. 63

THIOPHANATE-METHYL in air 5606

Certified Reference Material - Certificate of Analysis

Certified Reference Material - Certificate of Analysis

A Single Analyzer Solution for Refinery Flare Emissions Monitoring (40 CFR 60 Subpart Ja) Using Mass Spectrometry

Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS

Improved Gas Chromatograph Method for the Analysis of Trace Hydrocarbon Impurities in 1, 3-Butadiene

Certified Reference Material - Certificate of Analysis

METHOD 25D - DETERMINATION OF THE VOLATILE ORGANIC CONCENTRATION OF WASTE SAMPLES. NOTE: Performance of this method should not be

Methane baseline concentrations and sources in shallow aquifers from the shale. gas-prone region of the St. Lawrence Lowlands (Quebec, Canada)

Analytical Gas Systems Product Catalog

Calibration Standards for Measurement of Toxic Organics in Biogas and Biomethane Using Permeation Tubes

á1225ñ VALIDATION OF COMPENDIAL PROCEDURES

Certified Reference Material - Certificate of Analysis

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

Using the Pulsed Flame Photometric Detector (PFPD) for Low-level Analysis of Organophosphorus Pesticides

CLSI C60: Assay Validation & Post-Validation Monitoring

Hydrogen Generators for Fuel Gas

SANTA BARBARA COUNTY APCD GUIDANCE DOCUMENT FOR EMISSION VERIFICATION OF CONTAMINATED SOIL/GROUNDWATER CLEANUP (CSC) PROCESSES

Certified Reference Material - Certificate of Analysis

ICH Q2(R1) A Primer. cgmp. GxP PIC/S SOP ISO QA/QC LOD/LOQ. Validation of Analytical Methods API EP FDA OECD GCP

When optimization is discussed throughout this talk, it s in terms of performing more samples, in less time, while minimizing investment in capital

Gas Generators. Parker Balston

Certified Reference Material - Certificate of Analysis

Application Note AN1501

EDB July ETHYLENE DlBROMlDE. F. Analytical Quantitation... I. Determinative Method. Contents. A. Introduction I3. Equipment...

TOWARDS THE UNIFYING OF THE DETECTION SYSTEMS FOR THE MEASUREMENT OF THE MAJOR GREENHOUSE GASES AND RELATED TRACERS

GUIDANCE NOTES ON ANALYTICAL METHOD VALIDATION

Agilent 7693A Series Automatic Liquid Sampler Inject new performance into your gas chromatography. Our measure is your success.

PROCESS ANALYZERS FOR PURIFIED BULK GAS QC/QA: ENTERING THE PPT RANGE

STANDARD OPERATING PROCEDURES SOP: 2021 PAGE: 1 of 7 REV: 0.0 DATE: 10/26/94

Project Summary. Field Evaluation of EPA Method 0040 (Volatiles Using Bags)

Title: Standard Operating Procedure for Measurement of CO in Ambient Air by Gas Filter Correlation (GFC)

Transcription:

PAGE: 1 of 5 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING, AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS 7.0 PROCEDURE 7.1 Gas Chromatograph 7.2 Calibration 7.3 Injection of Sample 8.0 CALCULATIONS 9.0 QUALITY ASSURANCE/QUALITY CONTROL 9.1 Precision 9.2 Accuracy 10.0 DATA VALIDATION 11.0 HEALTH AND SAFETY SUPERCEDES: SOP #1708, Revision 2.1; 04/17/91; U.S. EPA Contract EP-W-09-031.

PAGE: 2 of 5 1.0 SCOPE AND APPLICATION This standard operating procedure (SOP) is intended for use when analyzing Summa canister gas samples for low parts per million volume (ppmv) levels of methane. These are standard (i.e., typically applicable) operating procedures which may be varied or changed as required, dependent on site conditions, equipment limitations or limitations imposed by the procedure or other procedure limitations. In all instances, the ultimate procedures employed should be documented and associated with the final report. Mention of trade names or commercial products does not constitute U.S. EPA endorsement or recommendation for use. 2.0 METHOD SUMMARY A flame ionization detector (FID) gas chromatograph (GC) is used to separate and quantitate methane in gas samples. The sample is introduced into the carrier gas as a plug and passes through a gas chromatography column which then separates it into two peaks. The first peak is unresolved air; the second peak is resolved methane. Peak areas are used in conjunction with calibration plots for quantitative measurements. This separation is completed in five minutes. 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING, AND STORAGE Refer to U.S. EPA Method T014 concerning Summa canister cleaning and sample collection. In addition refer to Environmental Response Team/Scientific, Engineering, Response and Analytical Services (ERT/SERAS) ERTSERAS SOP #1703, Summa Canister Cleaning Procedures and SOP #1704, Summa Canister Sampling. Canisters are stored and analyzed at room temperature. 4.0 INTERFERENCES AND POTENTIAL PROBLEMS This section is not applicable to this SOP as interferences have not been studied. 5.0 EQUIPMENT/APPARATUS Gas Chromatograph - Varian 3400 gas chromatograph with flame ionization detector (or equivalent) capable of operating at 225 o C. Carrier gas cylinder - ultra high purity helium with a two stage regulator delivering a pressure of 90 psi 1 ml and.1 ml precision gas-tight syringes with needles for sample introduction Gas chromatography column - 10 ft. x 1/4 in. stainless steel column packed with Spherocarb, 100/120 mesh (or equivalent), capable of operating at 100 o C, injection temperature of 200 o C Electronic integrator - Spectra-Physics SP4290 integrator (or equivalent) Septum port adaptor for Summa canister Soap film flow meter (or equivalent)

PAGE: 3 of 5 6.0 REAGENTS 7.0 PROCEDURES Helium - Ultra high purity grade helium (99.9999%) Hydrogen - Ultra high purity grade hydrogen (99.9999%) Air - Ultra zero grade air (<0.05 ppmv total hydrocarbon) Calibration standards (in the range of 5-100 ppmv) - methane standards, balance air 7.1 Gas Chromatograph The carrier gas is turned on and the flow rate adjusted to 40 ml per minute. The air is turned on and the flow rate adjusted to 150 ml per minute. The hydrogen is turned on and the flow rate is adjusted to 30 ml per minute. The flows are checked with a soap film flow meter. The flame ionization detector is then ignited and allowed to equilibrate for ten minutes. The integrator is turned on and zeroed before samples are introduced. 7.2 Calibration Introduce, via 1 ml syringe, aliquots of the same size as will be used on the sample injections of the standard calibration gas mixtures in the gas chromatograph injector. At least one injection each standard gas mixture is required before starting to analyze samples. The very first calibration should be performed in triplicate. Verify the initial calibration by injection of a complete set of at least four standards (at least five different concentrations of standards are routinely available from commercial suppliers) at the commencement of each day's analytical activities. It is suggested that each sample injection be followed systematically by a standard injection so that many injection areas are tabulated and averaged in the report. 7.3 Injection of Sample 8.0 CALCULATIONS A 1-mL sample is withdrawn from the Summa septum port using a 1-mL gas-tight syringe. The sample is quickly injected, guarding against blow-back of the plunger. Simultaneously, the integrator is activated and the sample run is labeled. The integrator run is ended in five minutes and rezeroed before the next analysis. Samples analyzed above the calibrated linear range can be reanalyzed by injecting a smaller volume, or by diluting in ultra high purity zero air to acquire responses within the linear range. These dilutions may be done by injecting a measured volume of the sample into Tedlar bag and adding a measured volume of zero air. For instance, 100 ml of sample measured with a gas tight syringe, added to 900 ml of zero air would be diluted by a factor 10. These volumes have to be recorded and taken into account in the calculations.

PAGE: 4 of 5 A linear standard curve of ppmv versus peak area is prepared. The sample concentrations are calculated using the formula y = mx + b; The above equation may be rearranged to where y is the peak area, m is the slope (peak area/ppmv), b is the y intercept (peak area), and x is the concentration (ppmv). x = y-b m where y is measured area, corresponding to a sample injection and x is the desired methane concentration in the sample injection. If a dilution has been made then, of course, the concentration obtained must be multiplied by the ratio of the final sample volume to the initial sample volume. Most integrator packages will handle the above calculations but it is recommended that a commercial spreadsheet program be used so that the final report preparation may be expedited. 9.0 QUALITY ASSURANCE/QUALITY CONTROL The following quality assurance/quality control procedures are applicable: 9.1 Precision The precision of the method is monitored during the second lowest calibration standard from the linear curve. A control range is established for the standard using three standard deviations from the mean of ten independent analyses. The standard is analyzed periodically (at the beginning and end of a series of samples or every 8 hours) and must respond within the range of three standard deviations for the system and data precision to be considered under control. If the results of the standard analysis are out of range, the system must be repaired and the standards rerun, for a new calibration curve must be performed. 9.2 Accuracy 10.0 DATA VALIDATION The accuracy of the method is monitored by periodically analyzing blind performance evaluation samples. These samples should not be prepared by the same outside source that the calibration standards were obtained from. Data will be evaluated based on the information provided by Section 9.0. 11.0 HEALTH AND SAFETY

PAGE: 5 of 5 When working with potentially hazardous materials, refer to U.S. EPA, OSHA or corporate health and safety practices.