Efficient and Flexible AHAT Gas Turbine System

Similar documents
A Study of Performance on Advanced Humid Air Turbine Systems

Latest Simulation Technologies for Improving Reliability of Electric Power Systems

Completion of Hitachi Rinkai Power Station Unit-2

The H-25/H-15 Gas Turbine A Product of Hitachi Quality

MCFC/MGT Hybrid Generation System

MCFC/MGT Hybrid Generation System

The H-25/H-15 Gas Turbine A Product of Hitachi Quality

High Bridge Combined Cycle Plant

Development status of the EAGLE Gasification Pilot Plant

Hitachi H-25 & H-80 Gas Turbine. Bucharest, Apr.23, 2013

Power cycle development

Feature: New Project Development Using Innovative Technology

SOME ENERGY-EFFICIENT TECHNOLOGIES IN JAPAN

Creating the Future of Coal-Fired Power Generation

2. TECHNICAL DESCRIPTION OF THE PROJECT

Energy Procedia

NEDO s research and development of Clean Coal Technology for reducing CO 2 emission

Various Applications of High-efficiency H-25 Gas Turbine

Chapter 8. Vapor Power Systems

Course 0101 Combined Cycle Power Plant Fundamentals

Aiming for the Realization of a Low- Carbon Society through Natural Gas

Overview of Kashima Thermal Power Station. 1. Summary of power station (1) Location 9, Touwada, Kamisu city, Ibaraki prefecture, Japan

Power Systems. Thermal Power. Hydraulic Power. New Energy. Electric Power Distribution

Toshibaʼs Activities in Carbon Capture

Improving Flexibility of IGCC for Harmonizing with Renewable Energy - Osaki CoolGen s Efforts -

EFFECT OF AMBIENT TEMPERATURE, GAS TURBINE INLET TEMPERATURE AND COMPRESSOR PRESSURE RATIO ON PERFORMANCE OF COMBINED CYCLE POWER PLANT

Large-scale Carbon Dioxide Capture Demonstration Project at a Coal-fired Power Plant in the USA

Development of Electricity and Energy Technologies for Low-carbon Society

Combined Heat and Power

NOx CONTROL FOR IGCC FACILITIES STEAM vs. NITROGEN

Feed-Water Repowering in Besat Power Plant: Technical and Costing Aspects

Innovative Zero-emission Coal Gasification Power Generation Project

Distributed Energy System - pooling heat and power -

GAS-FIRED COMBINED-CYCLE POWER PLANTS HOW DO THEY WORK? A company of

Pre-owned 240 MW Combined Cycle Gas Turbine Power Plant

Vocabulary. Heat production and transfer

Gas-fired efficiency in part-load and pulse operation

Cogeneration. Thermal Chillers. and. .. ASHRAE National Capital Chapter. Arlington, VA 10/10/2012

THE EFFECTS OF THE M-CYCLE ON THE PERFORMANCE OF A GAS TURBINE

BCE Program March-2017 Electrical Power Systems Time: min Quiz 1 Model A رقم المجموعة:

COMBINED CYCLE OPPORTUNITIES FOR SMALL GAS TURBINES

Potential of Allam cycle with natural gas to reduce carbon dioxide emission in India

A novel CO 2 -capturing natural gas combined cycle with LNG cold energy utilization

Superior Efficiency Reduced Costs Viable Alternative Energy Kalex Kalina Cycle Power Systems For Biomass Applications

2The J-POWER Group is one of the biggest coal users in Japan, consuming approximately 20 million

Combustion Chamber. Fig Schematic diagram of a simple gas turbine

New Power Plant Concept for Moist Fuels, IVOSDIG

Geothermal Steam Turbines for Various Purposes

Progress in NAKOSO 250 MW Air-Blown IGCC Demonstration Project

Dry Low-NOx Combustion Technology for Novel Clean Coal Power Generation Aiming at the Realization of a Low Carbon Society

Electric Power Supply Systems that Contribute to Low carbon Society

INTEGRATION OF A NEW CCGT PLANT AND AN EXISTING LNG TERMINAL AT BARCELONA PORT Abstract ID Number: 155

Innovative Technology for Using Bioethanol to Achieve a Low-carbon Society

A TECHNOLOGY FOR TODAY. Atlanta 2010

State of the Art (SOTA) Manual for Stationary Gas Turbines

Explanation of JCM Feasibility Study in Thailand & Applicable Low CO2 Emission Technology

Equipment Design. Detailed Plant Conceptual Design. Version 7.0

Japanese Policy for Cleaner Coal - Towards Zero Emission

A proposed new gas-fired power station on the Wilton International site

A CHCP System Constituted by Microturbine and Exhaust Absorption Chiller

Recent Technologies for Steam Turbines

CO-GENERATION PLANT KUSHA INDUSTRY CO.

09/30/2010 Waterside Power Redline Version: Matt Lydon Formatted: Font: Bold, Italic Formatted: Font: Bold, Italic Draft Model Rule Control of Natural

CONTROL STRTEGIES FOR FLEXIBLE OPERATION OF POWER PLANT INTEGRATED WITH CO2 CAPTURE PLANT

Vapor and Combined Power Cycles

Development of Measurement Method for Verification of Multi-Stage Axial Compressor with Improved Performance

Investigation of steam injection effect and exergy analysis on ABC gas turbine cycle

Scott Hume. Electric Power Research Institute, 1300 West WT Harris Blvd, Charlotte NC 28262

Large Frame Gas Turbines, The Leading Technology of Power Generation Industries

IJARI. Nomenclature. 1. Introduction. Volume 2, Issue 2 (2014) ISSN International Journal of Advance Research and Innovation

Thermodynamic analysis of a regenerative gas turbine cogeneration plant

ScienceDirect. Cogeneration process modelling in a paper factory

Development of 1MW high efficiency gas engine cogeneration system

DEVELOPMENT OF HITACHI OXY-COMBUSTION TECHNOLOGY WITH NEW TYPES OF BURNER AND FLUE GAS RE-CIRCULATION SYSTEM

High efficient peak power on demand. Answers for energy.

Trial Operation Results of Steam Cooled M501H Type Gas Turbine

Evaporative Gas Turbine (EvGT)/Humid Air Turbine (HAT) Cycles

START UP ANALYSIS OF A H2-O2 FIRED GAS TURBINE CYCLE

Performance Analysis of Fogging Cooled Gas Turbine with Regeneration and Reheat under Different Climatic Conditions

Energy Audit Summary Report Audit No. 21. Pharmaceutical Industry

Challenges in Industrial Waste Heat Recovery. Texas Technology 2006 Showcase Tony Dafft December 6 & 7, 2006

TransPacific Energy Advantage: Case Studies

Design Optimisation of the Graz Cycle Prototype Plant

Long-term Operation of a Small-scale Gasification and Power Generation Plant for Chicken Manure

A qualitative comparison of gas turbine cycles with CO 2 capture

Matching of a Gas Turbine and an Upgraded Supercritical Steam Turbine in Off-Design Operation

Drive Selection for LNG FPSO

Equipment Design. Detailed Plant Conceptual Design. Version 9.0

THE ALL-IN-ONE INLET AIR COOLING AND FILTRATION SOLUTION USING YOUR WASTE HEAT FREUDENBERG FILTRATION TECHNOLOGIES

Challenges in Designing Fuel-Fired sco2 Heaters for Closed sco2 Brayton Cycle Power Plants

Gas Turbine Inlet Air Cooling System

Understand boiler performance characteristics. Use these suggestions when buying, designing or optimizing steam generators

New 790-Megawatt Unit. Council Bluffs Energy Center

Exhaust Heat Recovery Systems

RESEARCH ON MICRO GAS TURBINE EXHAUST HEAT RECOVERY AND USAGE

ANGUIL. we will begin shortly. Take the Heat and Reuse it Oxidizer Operating Cost Reduction Strategies

Carrington Power Station

LIQUID AIR ENERGY STORAGE (LAES) Pumped Hydro Capability No Geographical Constraints

Commercialization of Clean Coal Technology with CO2 Recovery

Recent and future needs on the operation of combined cycle power plants. Kilian Link, Siemens, Energy Sector

Transcription:

Efficient and Flexible AHAT Gas Turbine System Efficient and Flexible AHAT Gas Turbine System 372 Jin ichiro Gotoh, Dr. Eng. Kazuhiko Sato Hidefumi Araki Shinya Marushima, Dr. Eng. OVERVIEW: Hitachi is developing an AHAT gas turbine system that features high efficiency and excellent operational characteristics. AHAT is a new type of gas turbine generation system in which the regenerative cycle has been enhanced. AHAT achieves higher efficiency without increasing the pressure ratio or combustion temperature, and does not require high-grade, hightemperature materials. Furthermore, because a boiler or steam turbine is not used in AHAT, it is expected to provide flexible operation and a high load change rate. The feasibility of the system has been verified through testing on a 3-MWclass pilot plant. A 40-MW-class pilot plant is currently under construction and is scheduled to commence operation in the latter half of the 2011 fiscal year. Subsequent plans include conducting tests at the demonstration plant and improving efficiency in preparation for commercialization, the aim being to enter the market with a power plant in the 100- to 200-MW output class. INTRODUCTION GAS turbines have been widely adopted as emergency power supplies since the late 1970s because of features including short construction and installation times and rapid load change rate. Combined cycle plants, which combine gas and steam turbines, have high efficiency and have come to be used as high-capacity base-load power plants. Nevertheless, high-capacity combined cycle plants suffer from a number of problems such as being unable to handle rapid load change rate. In addition, their high combustion temperatures and use of expensive materials result in high maintenance costs, and the steam turbine s condenser needs to be located by water. In response to these problems, Hitachi developed the AHAT (advanced humid air turbine) to be an efficient and flexible gas turbine system (1), (2), (3). The AHAT system was proposed by Hitachi and the company was the first in the world to confirm its feasibility on a pilot plant. The Cool Earth-Innovative Energy Technology Program, adopted by the Japanese government to undertake specific measures for preventing global warming designated the technology as an efficient gas turbine and the development work needed to commercialize it is being carried out as a national project with funding from the Agency for Natural Resources and Energy. This article describes the new AHAT gas turbine system. AHAT A combined cycle generation system combines a gas turbine and steam turbine. The gas turbine uses gas at high temperature and pressure to generate electric power. The remaining heat in the exhaust gas is then used to boil water, which is fed into a steam turbine to generate more electric power. In contrast, AHAT is a new type of gas turbine generation system that can achieve high efficiency without a steam turbine by using a recuperator to recover heat from the gas turbine exhaust and injecting moisture at a level comparable to the steam used in a steam turbine. AHAT Features Table 1 lists AHAT s features. Because it lacks a steam turbine, the operational characteristics of AHAT are expected to be more flexible than combined cycle plants. AHAT has a fast start-up speed and responds to load changes similarly to a standalone gas turbine, meaning that AHAT can operate at low load with a minimal output drop when the ambient temperature is high. In terms of the environment, use of combustion with humid air achieves lower NOx (nitrogen oxides) emissions, and since the system uses a cooling tower it can be installed inland. The economic benefits of AHAT include fewer components and a shorter construction time owing to the simple equipment configuration made by dispensing with the steam turbine. Moreover, AHAT does not require high-grade, high-temperature materials because a gas turbine has low combustion temperature. It is anticipated that piping, water quality management, and utility usage will be similar to a combined cycle plant.

Operation Environmental performance Hitachi Review Vol. 60 (2011), No. 7 373 TABLE 1. Comparison of AHAT and Combined Cycle The equipment configuration of an AHAT is simpler than that of a combined cycle plant because AHAT does not have a steam turbine or waste heat recovery system. The advantages of AHATs are excellent operational characteristics, fewer restrictions on siting, and shorter construction time. Economics Comparison AHAT Combined cycle Start-up speed Faster start-up speed due to not having an ST ST and HRSG require warming-up Load responsiveness Equivalent to standalone GT system Base Minimum load Dependence on ambient temperature Combustion by humid air allows operation at low load. Minimal loss of output when temperature high due to use of water atomization cooling Ease of control Simple, equivalent to standalone GT system Requires control of ST. NOx reduction Restrictions on siting Construction lead time Piping Water quality management Use of utilities Maintenance costs Combustion with humid air results in low NOx. NOx removal equipment may be required in some cases. Can be sited inland because water is recovered at about 60 C which can be cooled using a cooling tower. Short due to simple equipment configuration with no ST Thin-wall piping as GT compressor outlet pressure is low. However, wide-diameter piping is required for regenerative cycle system. Requires water treatment system (such as ion exchange resin). Demineralized water (for compressor water atomization cooling), ammonia (for NOx removal), cooling water (cooling tower replenishment) Simple equipment configuration (no waste heat recovery or water recovery system); low GT combustion temperature : notably superior : superior : equivalent AHAT: advanced humid air turbine ST: steam turbine HRSG: heat recovery steam generator GT: gas turbine Limited by need for stable combustion with low NOx emissions. Loss of output occurs when temperature is high. Low NOx can be achieved using a low-nox combustor or by water or steam injection. NOx removal equipment is required. Must be located near water as ST output water temperature is 30 C and a condenser is required. Base Thick-wall piping required for high-pressure section of HRSG. Small-diameter pipes can be used for main steam piping. Requires addition of chemicals for ph control. Demineralized water (for HRSG blow replenishment), ammonia (for NOx removal), cooling water (replenishment) Includes waste heat recovery, ST, and condenser systems; high GT combustion temperature. System Configuration Fig. 1 shows a schematic of the AHAT system. This AHAT system combines increased output (due to humidification) with higher thermal efficiency (due to the regenerative cycle of the recuperator). A water atomization cooling system is located at the inlet of the gas turbine compressor. The increase in intake air quantity resulting from intake cooling and the transformation of atomized droplets into steam in the compressor act to reduce the compressor power requirement and minimize the output drop during summer. The air compressed by the compressor is humidified by hot water in the humidification tower. The compressed and humidified air passes through the recuperator where it is first heated by heat recovered from the exhaust gas and then supplied to the combustor. Use of humid air in combustion also significantly reduces the amount of NOx. Although demineralized water is used for humidification, the system includes a water recovery system in which most of the moisture content in the exhaust gas is recovered for reuse. The recovered water is supplied to the humidification tower and a Fuel Combustor Compressor Turbine Air (2) Humidification tower: higher output Water (1) Water atomization cooling system: reduce compressor power requirement. (3) Recuperator: waste heat recovery (4) Water recovery system Water Fig. 1 AHAT System Configuration. AHAT includes a water atomization cooling system, humidification tower, recuperator, and water recovery system. The design is simpler than that for a combined cycle plant. proportion is also cooled and recirculated into the water recovery system. Fig. 2 shows the outputs and efficiencies of different types of power generation systems. The

Efficient and Flexible AHAT Gas Turbine System 374 70 Exhaust stack Efficiency at generator (LHV%) 60 50 40 30 20 1 Target efficiency for AHAT cycle Cheng Cycle (steam-injected gas turbine) Single-pressure C/C Aeroderivative GT Simple cycle GT Source: Gas Turbine World (2010 GTW Handbook) C/C: combined cycle LHV: lower heating value Double-pressure C/C Triple-pressure C/C 10 100 1,000 Generator output (MW) Fig. 2 Output and Efficiency Relations for Different Electric Power Generation Systems. The target for the AHAT is to have the best performance in the medium-capacity class. target for AHAT is to have the best efficiency of all existing power generation systems in the mediumcapacity class. PROGRESS IN TECHNOLOGY DEVELOPMENT Operational Assessment Using 3-MW-class (4), (5) Pilot Plant Hitachi developed a 3-MW-class pilot plant and conducted testing of the entire AHAT system s feasibility, its dependence on ambient temperature, and its operational characteristics (see Fig. 3). Fig. 4 shows the dependence on ambient temperature. The test results indicate that both output and efficiency behave as predicted by calculation based on the heat balance. Fig. 5 shows the test results for the turbine speed and generator output during a cold start (startup from a full shutdown). The rated output is reached after about 60 minutes, considerably faster than the approximately 180 minutes required to cold start a conventional combined cycle plant. The AHAT start-up time is equivalent to a hot start of a combined cycle plant. 40-MW-class System Test Facility Fig. 6 shows the block diagram of a 40-MW-class pilot plant. This system configuration is used to test the interaction between the axial-flow compressor, recuperator, multi-can combustor, and cooling blades (all of which are designed to operate with humid air) under conditions of high pressure and humidity. The Cooling tower Filter house Humidification tower Water recovery system Height: 11.5 m Load resistor GT enclosure Waste water Generator treatment system Water heater Recuperator AHAT system pilot plant (Hitachinaka City, Ibaraki Prefecture) Length: 26 m Fig. 3 3-MW-class Pilot Plant. Trials were conducted to assess the feasibility, dependence on ambient temperature, and operational characteristics of the entire system. Generator output (kw) 4,200 4,000 3,800 3,600 3,400 3,200 3,000 Output Efficiency Predicted value 2,800 34 0 5 10 15 20 25 30 35 40 Ambient temperature ( C) Fig. 4 Dependence on Ambient Temperature. The measured and calculated values for output and efficiency both show similar behavior. Output (MW) 4 160% 140% 3 Generator output 120% 100% 2 Turbine speed 80% 60% 1 40% 20% 0 0% 0 30 60 90 Time after startup (min) Fig. 5 Turbine Speed and Generator Output during Cold Start. The system reaches its rated output about 60 minutes after a cold start, similar to a hot start on a combined cycle plant. plant design has been completed, and construction of this plant is underway. Load testing is planned for the latter half of the 2011 fiscal year. 48 46 44 42 40 38 36 Generation efficiency (%LHV) Speed (%)

Hitachi Review Vol. 60 (2011), No. 7 375 Air Fuel Combustor Compressor Turbine blade cooling Load compressor Humidifier Water atomization cooling system Recuperator Make-up water Fig. 6 System Block Diagram of 40-MW-class System Test Facility. The pilot plant is used to determine the interaction between its different components under conditions of high pressure and humidity. FUTURE DEVELOPMENTS Spin-offs of Specific Technologies blade cooling (which was developed as a separate technology) and technologies that have emerged from the technical development process for humid air combustion have been applied to Hitachi s range of gas turbines. These technologies are helping to reduce the environmental burden by decreasing the volume of cooling air and thus improving efficiency and cutting emissions of CO 2 (carbon dioxide) and NOx. Distributed Power Sources Small to medium-sized power generation systems with high efficiency can help to supply electric power in areas where the grid transmission infrastructure is inadequate, particularly those areas experiencing rapid growth in energy demand. They can also be used to build cogeneration (electricity and heat) systems. Fuel Flexibility Against a background of rapidly rising fuel prices, energy security considerations are driving the demand for fuel flexibility. With fuel being an important factor when selecting a power generation system, the ability to operate using a range of different fuels is expected to open up the system to a wider range of users. One example is the anticipated increase in the use of liquid biofuels, which have, in effect, zero emissions of CO 2. Since obtaining the required amount of fuel is comparatively easy for the medium-sized power plants to which AHAT is particularly suited, the adoption of AHAT is likely to encourage the use of liquid biofuels. Electric Power System Stabilization Measures Required for Adoption of Photovoltaic Power Japan intends to reduce emissions of greenhouse gases by 25% relative to 1990 levels by 2020 and, to this end, has set a target of installing 28 GW of solar power by 2020 (20 times the 2005 capacity). The Study Group on Low Carbon Power Supply System at the Ministry of Economy, Trade and Industry has reported on the need for solar power generation to be backed up by thermal power (6). This group identified the following performance requirements for thermal power generation used as a backup for solar power: (1) Short start-up time prior to starting generation (2) High rate of change in output (kw/min) in response to sudden changes in demand (3) Low minimum load level (known as having a large depowering margin ) (4) Adequate capacity for governor-free operation and LFC (load frequency control) (5) Minimal reduction in efficiency when operating at low load (6) Ability to operate on a range of different fuels. Table 2 lists how different power generation systems compare in terms of these performance requirements for handling the fluctuations in solar power output, assuming a 100-MW-class gas-fired TABLE 2. Performance Requirements for Handling Fluctuation in Solar Power Output Compared with combined cycle and conventional steam power, AHAT exhibits good performance in response to fluctuating loads. Required performance characteristic Short start-up time prior to starting generation High rate of change in output (kw/min) in response to sudden changes in demand Low minimum load level Adequate capacity for governor-free operation and LFC Minimal reduction in efficiency when operating at low load (efficiency between 50 100% load, HHV) Power generation system (comparison of 100-MW-class gas-fired plants) AHAT (targets) 30 min (hot start) 60 min (cold start) 8.3 10%/ min 25% load LFC use 43 51% GT combined cycle 60 min (hot start) 180 min (cold start) 5%/min 50% load LFC use 40 50% Conventional steam 180 min or longer 3 5%/min 20% load Governor-free operation and LFC use 38 40% LFC: load frequency control HHV: higher heating value : base level

Efficient and Flexible AHAT Gas Turbine System 376 power plant. Although the values for AHAT are still targets at this stage, the excellent start-up speed, load change rate, and operating load range of this technology indicate that it should help in maintaining power system stability. CONCLUSIONS This article has described the new AHAT gas turbine system. The AHAT system has improved cooling and an enhanced regeneration cycle, and is expected to achieve high efficiency, excellent operational characteristics, and good economics, without increasing pressures or combustion temperatures. This new technology for increasing efficiency has been recognized by a total of seven awards over the past five years from industry bodies in both Japan and overseas, including the J. P. Davis Award (4) from the American Society of Mechanical Engineers (ASME). A 40-MW-class pilot plant is currently under construction and due to commence operation in the latter half of the 2011 fiscal year. Subsequent plans include conducting tests at the demonstration plant and improving efficiency in preparation for commercialization, the aim being to enter the market with a power plant in the 100- to 200-MW output class. acknowledgments This research and development has received funding for advanced technology development for energy use rationalization from the Electricity and Gas Industry Department of the Agency for Natural Resources and Energy at the Ministry of Economy, Trade and Industry and is being conducted in cooperation with the Central Research Institute of Electric Power Industry and Sumitomo Precision Products Co., Ltd. We would like to express our thanks to these organizations. REFERENCES (1) S. Hatamiya, Gas Turbine Generation Technology Using Humid Air, Journal of the Thermal and Nuclear Power Engineering Society 552, pp. 47 54 (Sep. 2002) in Japanese. (2) S. Marushima et al., Development of Advanced Humid Air Turbine, 2007 Conference on Thermal and Nuclear Power (2007) in Japanese. (3) T. Takahashi, Research and Development of the Advanced Humid Air Gas Turbine (AHAT) Development of 3MW Verification Plant and Demonstration of the System, CRIEPI Research Report (Sep. 2008) in Japanese. (4) S. Higuchi et al., Test Results from the Advanced Humid Air Turbine System Pilot Plant - Part 1, ASME Turbo EXPO 2008, ASME Paper GT2008-51072 (2008). (5) H. Araki et al., Experimental and Analytical Study on the Operation Characteristics of the AHAT System, ASME Turbo Expo 2011 GT2011-45168 (2011). (6) Documents for Study Group on Low Carbon Power Supply System, Agency for Natural Resources and Energy, Ministry of Economy, Trade and Industry (2008) in Japanese. ABOUT THE AUTHORS Jin ichiro Gotoh, Dr. Eng. Joined Hitachi, Ltd. in 2000, and now works at the Gas Turbine Planning Section, Gas Turbine Design and Service Department, Hitachi Works, Power Systems Company. He is currently engaged in development and planning of the AHAT system. Dr. Gotoh is a member of The Japan Society of Mechanical Engineers (JSME), The Society of Materials Science, Japan, and the Gas Turbine Society of Japan (GTSJ). Kazuhiko Sato Joined Hitachi, Ltd. in 1992, and now works at the Plant System Engineering Section, Thermal Power Plant Engineering Department, Thermal Power Systems Development & Management Division, Power Systems Company. He is currently engaged in development and planning for new power generation systems. Mr. Sato is a member of the GTSJ. Hidefumi Araki Joined Hitachi, Ltd. in 1991, and now works at the Department of Gas Turbine Research, Hitachi Research Laboratory. He is currently engaged in research and development of the AHAT system. Mr. Araki is a member of the GTSJ and JSME. Shinya Marushima, Dr. Eng. Joined Hitachi, Ltd. in 1992, and now works at the Department of Gas Turbine Research, Hitachi Research Laboratory. He is currently engaged in gas turbine research. Dr. Marushima is a member of the JSME and the GTSJ.