TRUFILL DCS ORBIT Detachable Coil System

Similar documents
TRUFILL n-butyl Cyanoacrylate (n-bca) Liquid Embolic System

Azur Peripheral Coil System Helical HydroCoil Embolization System (Detachable) Instructions for Use

ASAHI Masters PARKWAY SOFT. ASAHI Masters PARKWAY HF

ASAHI Masters PARKWAY HF KIT

EkoSonic MACH4 Endovascular Device Instructions for Use

Drug-Eluting Beads Current Indication Status

Evolution of Embolization

RePlay Hemostasis Clip

GDC Detachable Coils, GDC 360o Detachable Coils, Matrix2 Detachable Coils, and Target Detachable Coils

Acoustic Pulse Thrombolysis Treatment

intervention embosphere embogold quadrasphere bearing nspva

Instructions for Use Reprocessed Coronary Sinus Diagnostic Electrophysiology Catheter

INSTRUCTIONS FOR USE FOR:

MIIG INJECTABLE Graft The following languages are included in this packet:

Page 1 of 6 Reprocessed by. Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.

Contrast media administration - Alternatives to the cubital vein

PER F ORM ANC E b y d e s i g n. Pioneering TEVAR Therapy, Time and Time Again. CONFORMABLE

Decide, guide, treat and confirm: The Philips Volcano CLI solution

CapSure Permanent Fixation System

TREAT SMARTER. ACHIEVE MORE. When Treating Thrombus

Instructions for Use Reprocessed Electrophysiology Catheter Cables

Steerable Guide Wires Precision With Every Turn

White Paper: Implantable Fabrics Revolutionize Neurovascular Devices. Andrew Metzger Senior Process Development Engineer

Instructions for Use Reusable Electrophysiology Catheter Cables

PREVELEAK Surgical sealant

INSTRUCTIONS FOR USE FOR:

Image guided therapy. Neuro suite. Azurion. Neuro suite. Neuro decisions are based on what you see, so see more

Advancing the Open Ventral Hernia Repair Experience

EkoSonic Endovascular System

Instructions for Use Reusable Ablation Catheter Cables

Shapability, Memory, and Luminal Changes in Microcatheters after Steam Shaping: A Comparison of 11 Different Microcatheters

Advancing minimally invasive. therapeutics through novel device. development. Minima y Invasive New Technologies T H E L E O N A M. A N D H A R R Y B.

Complex Left Atrial (CLA) Best Practices for Navigant

ARROW EDGE. Antegrade-tunneled chronic hemodialysis catheter

CAUTION: U.S. Federal law restricts this device to sale by or on the order of a licensed physician.

HANDLING OF WRIGHT MEDICAL DISPOSABLE PROPHECY TM ANKLE INSTRUMENTS

VASCULAR ACCESS PRELUDE SHEATH INTRODUCERS. Merit Medical s Innovative Family of Vascular Access Products A GREAT INTRODUCTION

Conformability without Compromise

Clinical Applications. ImagingRite. Interventional Radiology

TRANSFORMING NEUROLOGICAL HEALTHCARE.

3D Roadmapping in neuroendovascular procedures an evaluation

Polidocanol Endovenous Microfoam (PEM) Comprehensive Treatment for Great Saphenous Vein System (GSV) Incompetence

3M Tegaderm PICC/CVC Securement Device + I.V. Advanced Securement Dressing Product Description

Conformability without Compromise

Bleed Management MAKING A DIFFERENCE TO HEALTH

Comfort your patient deserves. Strength you demand.

TRELLIS COLLAGEN RIBBON

Vascular. Making Best Use of Trinias Applications for Lower Extremity Interventional Procedures. 1. Introduction

BIOTAPE XM TISSUE MATRIX The following languages are included in this packet:

PRODUCT DEVELOPMENT OF A NEUROVASCULAR EMBOLIZATION DEVICE. A Thesis CHRISTOPHER JAMES MICIELLI

Ventrio ST Hernia Patch featuring Sepra Technology

ProCol Vascular Bioprosthesis

P E D A L A P P R O A C H

Lombard Medical, Inc. (NASDAQ:EVAR) June 2016

Whitepaper: Precision Micro-Braiding for Implantable Devices

Beyond Tried. True. GuideLiner V3 Catheter Guide Extension Catheter With Half-Pipe Technology

RapidPort EZ Access Port Kit DIRECTIONS FOR USE (DFU)

In-Service Presentation

Instructions for Use Reprocessed Masimo LNCS Pulse Oximeter Sensor. Reprocessed Device for Single Use

Time to Go Augmented in Vascular Interventional Neuroradiology?

S.M.A.R.T. Our inspiration came right from the source. Feeling is believing. S.M.A.R.T. Flex Vascular Stent System. LinkedIn page

English. DC Bead LUMI Radiopaque Embolic Drug-Eluting Bead. INSTRUCTIONS FOR USE Version 2

RapidPort EZ Port Applier DIRECTIONS FOR USE (DFU)

Protect the Neck. Lieven Maene, MD. Marc Bosiers Koen Deloose Joren Callaert. Patrick Peeters Jürgen Verbist. Lieven Maene Roel Beelen.

BREAKING BOUNDARIES WITH ICE

Clinical Experience Using SONIALVISION G4 Multi-Purpose R/F System for Angiographic Examinations

JUL Sponsor/Applicant Name and Address Penumbra, Inc Harbor Bay Parkway Alameda, CA 94502, USA

Flow Rate Measurement In Emissions Monitoring

ACCESS OPTIONS FOR PATIENTS WITH VENOUS OUTFLOW INSUFFICIENCY SYSTEM MERIT IS COMMITTED TO DIALYSIS ACCESS

Great Saphenous Vein Occlusion with Cyanoacrylate: An Alternative to Endovenous Laser Ablation?

ACTELION TRANSFORMATION ON THE WAY. Jean-Paul Clozel Chief Executive Officer. Copyright 2016 Actelion Pharmaceuticals Ltd

January 13, Texas Medical Technologies, Inc. Consultant Smith Associates 1468 Harwell Avenue Crofton, Maryland 21114

Interventional Fluoroscopy

LAP-BAND System Access Port II Kit

Monitoring of radiation dose using dose tracking software in a neurovascular intervention room

Wireless Implantable Micromachined Pressure Sensors: Approach and Clinical Demonstration

Urology and Women s Health

Novel technology for the surgical treatment of cerebrovascular diseases

Company Update. 28 May REVA Medical, Inc.

SUBJECT: INTRAVENOUS SOLUTIONS AND ADMIXTURE I.V.SOLUTIONS

THE OPTIONAL ALN VENA CAVA FILTER

An Arteriovenous Malformation Model for Testing Liquid Embolic Materials

Guide for Cleaning, Sterilization and Storage of Introducers for Caldera Medical Implants

Ordering information Metis Blue. Metis Green

Yukon Choice 4 DES Translumina - Allows natural healing

Symphion 6.3 Endoscope

Clinical Applications. ImagingRite. Neuro Intervention. 1 ImagingRite

Cre8 TM BTK polymer-free DES technology: the Activ8 clinical trial

Atherectomy as Primary Therapy for Lower Extremity Artery Disease: What will Be its Role in the Drug-Eluting Era

Failed thrombolysis in a 56-year-old aphasic and hemiplegic patient, what s next?

Instructions for Use Reprocessed Balloon Inflation Devices

Computer-Aided Surgical Navigation Coding Guide Neurosurgery. May 1, 2009

NeuroPort Array PN 4382, 4383, 6248, and 6249 Instructions for Use

in Film Nitinol: nique Biomaterial for Next Generation dovascular Devices

Guide for Cleaning, Sterilization and Storage of Reusable Introducers

Changing the Trajectory of Atrial Fibrillation and Stroke Shlomi Nachman

Head Fixation Using a Vac-Lok Cushion during Neuroendovascular Therapy

Interventional Tumor Therapy Minimally Invasive, Maximally Effective

Merit Medical s Innovative Family. of Vascular Access Products. A Great Introduction

Emilio Calabrese MD National Center for Limb Salvage Pavia Italy International Center for Limb Salvage

Transcription:

ORBIT Conforming to Your Complex Needs Excellent Conformability and Concentric Filling for Outstanding Packing Density

ORBIT Full range of Mini Complex and new Tight Distal Loop Technology coils Our Complex Standard coils are four times more stretch resistant than our Complex Fill Coils A customized fit for aneurysms: Random loops and breaks seek out the true aneurysm periphery Mini Complex Fill Coils Tight Distal Loop Technology NEW OFFERINGS 2 2 3 ORBIT Mini Complex Fill coils are designed for increased volumetric filling Extended offering of sizes including new 2.5 mm and 3.5 mm coils and longer 3 mm x 6 cm coil ORBIT Detachable Coils with Tight Distal Loop Technology First loop is /3 smaller than the coil diameter Avoids crossing the center of the aneurysm Fully Deployed Coil

ORBIT ORBIT Delivery System Advantages Conformability: The true complex structure of ORBIT Detachable Coils is designed to provide excellent conformability and concentric filling resulting in outstanding packing density. Outstanding packing density: In a recent study, use of complex-shaped coils with a wire diameter of 0.02 in. to coil cerebral aneurysms, resulted in significantly better packing than was achieved with helical coils of 0.00 in. wire diameter. Soft gripper tube results in minimal microcatheter tip deflection while coiling Stable coil delivery Gripper Tube: Transition from soft polymer delivery tube to coil Concentric Filling For Outstanding Packing Density Microcatheter Deflection Test Setup ORBIT Delivery System Competitive Wire Delivery Systems Clinical Evidence - Long-term Results Fill from periphery to core without crossing the center of the aneurysm Helps to minimize compartmentalization Complex random coil loop of ORBIT Detachable Coils Seek out free space and favor aneurysm periphery MICROCATHETERS For your coiling needs, Codman Neurovascular offers two versions of the PROWLER Microcatheter: PROWLER SELECT LP ES PROWLER 4 ORBIT Coil ORBIT Coil2 Complex Registry ORBIT Coil3 Number of Centers 37 Number of Aneurysms w/ Follow-up 95 99 3 Recanalization 5.8% 6.2% 2.9% Retreatment 7.8% 5.% 6.5% These studies show ORBIT cases with relatively low recanalization and retreatment rates PROWLER SELECT Microcatheter Offers more stability PROWLER Microcatheter Offers more flexibility for tortuous anatomy Data on file. 2 Slob, Neurol Res. 2005;27 Suppl :S6-9; 2 3 Hirsch, J Vasc Interv Radiol 2007; 8:487-494 Efficient neck coverage Potential for shutdown of aneurysm in-flow zone

ORBIT ORBIT Delivery System Advantages Conformability: The true complex structure of ORBIT Detachable Coils is designed to provide excellent conformability and concentric filling resulting in outstanding packing density. Outstanding packing density: In a recent study, use of complex-shaped coils with a wire diameter of 0.02 in. to coil cerebral aneurysms, resulted in significantly better packing than was achieved with helical coils of 0.00 in. wire diameter. Soft gripper tube results in minimal microcatheter tip deflection while coiling Stable coil delivery Gripper Tube: Transition from soft polymer delivery tube to coil Concentric Filling For Outstanding Packing Density Microcatheter Deflection Test Setup ORBIT Delivery System Competitive Wire Delivery Systems Clinical Evidence - Long-term Results Fill from periphery to core without crossing the center of the aneurysm Helps to minimize compartmentalization Complex random coil loop of ORBIT Detachable Coils Seek out free space and favor aneurysm periphery MICROCATHETERS For your coiling needs, Codman Neurovascular offers two versions of the PROWLER Microcatheter: PROWLER SELECT LP ES PROWLER 4 ORBIT Coil ORBIT Coil2 Complex Registry ORBIT Coil3 Number of Centers 37 Number of Aneurysms w/ Follow-up 95 99 3 Recanalization 5.8% 6.2% 2.9% Retreatment 7.8% 5.% 6.5% These studies show ORBIT cases with relatively low recanalization and retreatment rates PROWLER SELECT Microcatheter Offers more stability PROWLER Microcatheter Offers more flexibility for tortuous anatomy Data on file. 2 Slob, Neurol Res. 2005;27 Suppl :S6-9; 2 3 Hirsch, J Vasc Interv Radiol 2007; 8:487-494 Efficient neck coverage Potential for shutdown of aneurysm in-flow zone

ORBIT ORBIT Delivery System Advantages Conformability: The true complex structure of ORBIT Detachable Coils is designed to provide excellent conformability and concentric filling resulting in outstanding packing density. Outstanding packing density: In a recent study, use of complex-shaped coils with a wire diameter of 0.02 in. to coil cerebral aneurysms, resulted in significantly better packing than was achieved with helical coils of 0.00 in. wire diameter. Soft gripper tube results in minimal microcatheter tip deflection while coiling Stable coil delivery Gripper Tube: Transition from soft polymer delivery tube to coil Concentric Filling For Outstanding Packing Density Microcatheter Deflection Test Setup ORBIT Delivery System Competitive Wire Delivery Systems Clinical Evidence - Long-term Results Fill from periphery to core without crossing the center of the aneurysm Helps to minimize compartmentalization Complex random coil loop of ORBIT Detachable Coils Seek out free space and favor aneurysm periphery MICROCATHETERS For your coiling needs, Codman Neurovascular offers two versions of the PROWLER Microcatheter: PROWLER SELECT LP ES PROWLER 4 ORBIT Coil ORBIT Coil2 Complex Registry ORBIT Coil3 Number of Centers 37 Number of Aneurysms w/ Follow-up 95 99 3 Recanalization 5.8% 6.2% 2.9% Retreatment 7.8% 5.% 6.5% These studies show ORBIT cases with relatively low recanalization and retreatment rates PROWLER SELECT Microcatheter Offers more stability PROWLER Microcatheter Offers more flexibility for tortuous anatomy Data on file. 2 Slob, Neurol Res. 2005;27 Suppl :S6-9; 2 3 Hirsch, J Vasc Interv Radiol 2007; 8:487-494 Efficient neck coverage Potential for shutdown of aneurysm in-flow zone

ORBIT CONSTRUCTION Coil Outer Diameter: 0.02 inches Usable Length: 75 cm Easy-to-Use Introducer Design ordering information: PRODUCT COMPATIBILITY Compatible with Dual Markerband PROWLER SELECT LP ES and PROWLER SELECT Plus Microcatheters as well as PROWLER 4 and PROWLER Plus Microcatheters USA Codman & Shurtleff, Inc. 325 Paramount Drive Raynham, MA 02767 www.codman.com To place an order, call -800-255-2500. For technical/product questions, call -800-225-0460. For product availability, please contact your Codman Neurovascular representative. TDL Shape Coil Length Softness Catalog No. Diameter (mm) (cm) Type Mini Complex Fill 637MF020 2.5 FILL 637MF0202 2 2 FILL 637MF2525 2.5 2.5 FILL 637MF2535 2.5 3.5 FILL 637MF2545 2.5 4.5 FILL 637MF0303 3 3 FILL 637MF0304 3 4 FILL 637MF0306 3 6 FILL 637MF3505 3.5 5 FILL 637MF3575 3.5 7.5 FILL 637MF3509 3.5 9 FILL 637MF0403 4 3 FILL 637MF0407 4 7 FILL 637MF040 4 0 FILL 638MF0407 4 7 FILL 638MF040 4 0 FILL Complex Fill 637CF0505 5 5 FILL 637CF050 5 0 FILL 637CF055 5 5 FILL 637CF0609 6 9 FILL 637CF065 6 5 FILL 637CF073 7 3 FILL 637CF072 7 2 FILL 637CF085 8 5 FILL 637CF0824 8 24 FILL 637CF095 9 5 FILL 637CF0925 9 25 FILL 637CF030 0 30 FILL 637CF230 2 30 FILL Shape Coil Length Softness Catalog No. Diameter (mm) (cm) Type Complex Standard 637CS065 6 5 STANDARD 637CS072 7 2 STANDARD 637CS0824 8 24 STANDARD 637CS0925 9 25 STANDARD 637CS030 0 30 STANDARD 637CS230 2 30 STANDARD 637CS430 4 30 STANDARD 637CS630 6 30 STANDARD 637CS830 8 30 STANDARD 637CS2030 20 30 STANDARD Helical Fill 637HF0202 2 2 FILL 637HF0204 2 4 FILL 637HF0206 2 6 FILL 637HF0208 2 8 FILL 637HF0304 3 4 FILL 637HF0306 3 6 FILL 637HF0308 3 8 FILL 637HF030 3 0 FILL 637HF0406 4 6 FILL 637HF0408 4 8 FILL 637HF040 4 0 FILL 637HF052 5 2 FILL 637HF065 6 5 FILL 637HF075 7 5 FILL 637HF0830 8 30 FILL 637HF0930 9 30 FILL 637HF030 0 30 FILL 637HF230 2 30 FILL Shape Coil Length Softness Catalog No. Diameter (mm) (cm) Type Complex Fill - Tight Distal Loop 638MF0407 4 7 FILL 638MF040 4 0 FILL 638CF050 5 0 FILL 638CF055 5 5 FILL 638CF065 6 5 FILL 638CF072 7 2 FILL 638CF0824 8 24 FILL 638CF0925 9 25 FILL 638CF030 0 30 FILL 638CF230 2 30 FILL Complex Standard - Tight Distal Loop 638CS065 6 5 STANDARD 638CS072 7 2 STANDARD 638CS0824 8 24 STANDARD 638CS0925 9 25 STANDARD 638CS030 0 30 STANDARD 638CS230 2 30 STANDARD 638CS430 4 30 STANDARD 638CS630 6 30 STANDARD 638CS830 8 30 STANDARD 638CS2030 20 30 STANDARD TRUFILL DCS Syringe II / 635-002 ORBIT Detachable Coil Essential Prescribing Information (EPI) INTENDED USE: The ORBIT Detachable Coil is indicated for embolizing certain intracranial aneurysms that, because of their morphology, location, or the patient s general medical condition, are considered by the treating neurosurgical team to be:. Very high-risk for management by traditional operative techniques; 2. Inoperable and for embolizing other vascular malformations such as arteriovenous malformations and arteriovenous fistulae of the neurovasculature. The ORBIT Detachable Coil is also intended for arterial and venous embolization in the peripheral vasculature. CONTRAINDICATIONS: The use of the ORBIT Detachable Coil is contraindicated when: superselective placement is not possible; the arteries supplying the lesion are not large enough to accept embolic material; patent extra-to-intracranial anastomoses are present; end arteries lead directly to cranial nerves; the A-V shunt is bigger than the size of the coil; there is severe atheromatous disease; in the presence or likely onset of vasospasm. WARNINGS: Therapeutic embolizations to occlude blood vessels are high-risk procedures. The procedure should be carried out under the direction of personnel with the requisite interventional training and thorough knowledge of angiographic techniques, especially coil embolization techniques. Appropriate facilities should be available for managing the potential complications of the procedure. Contaminants found in the angiography room may cause foreign body reactions or infection. The physician must use the utmost caution to avoid introducing contaminants. Incomplete occlusion of vascular bed or territories may give rise to hemorrhage, ischemia, infarction, development of alternative vascular pathways, or recurrence of symptoms. Do not use any other syringes other than the specified TRUFILL DCS Syringe for operation of the ORBIT Detachable Coil. The introduction of air emboli may occur during detachment if one of the following is not performed properly: saline purge of the syringe to remove all air prior to connecting to the delivery tube hub; saline purge of the delivery tube with visual confirmation at the hub; saline flush of the delivery tube hub prior to any system reconnections. Do not use the distal tip of the infusion catheter to manipulate or reposition embolic coils previously detached in the patient s vasculature. Do not reuse. Discard after one procedure. Failure to open the second RHV sufficiently prior to slow and careful removal of the delivery tube from the patient could result in damage to the distal portion of the delivery tube. PRECAUTIONS: ORBIT Detachable Coils are delicate devices and should be handled carefully. Prior to use and when possible during the procedure, inspect the system for bends or kinks. Do not use a coil system that shows signs of damage. Do not expose the product to organic solvents. The long-term effects of this product on extravascular tissues have not been established, so care should be taken to retain this device in the intravascular space. Multiple embolization procedures may be required to achieve the desired occlusion of some vessels or aneurysms. The ORBIT Detachable Coil is intended for one use only. Do not resterilize and/or reuse the device. After use, dispose in accordance with hospital, administrative and/or local government policy. Store in a cool, dark, dry place. Do not use if package is open or damaged. Use prior to the Use By date. Angiography is necessary for the pre-embolization evaluation, operative control, and post-embolization follow up. Ensure proper detachable coil selection according to vascular territory and measurements taken from a baseline angiogram. ADVERSE EVENTS: Complications specific to embolization procedures may occur at any time during or after the procedure and may include, but are not limited to, the following: ischemia at an undesired location; stroke or cerebral infarction; coil migration into normal vessels adjacent to the lesion; pulmonary embolism; vessel dissection, perforation, rupture and hemorrhage; neurological deficits; injury to normal vessels or tissue; infection; allergic reaction; vasospasm; and/or death. Caution: Federal (USA) law restricts these devices to sale by or on the order of a physician. Prior to use, please read the more detailed information in the Instructions for Use. The third party trademarks used herein are trademarks of their respective owners. ORBIT, TRUFILL, Prowler and Prowler Select are registered trademarks of Codman & Shurtleff, Inc. 2009 Codman & Shurtleff, Inc. All Rights Reserved. Codman Neurovascular is a business unit of Codman & Shurtleff, Inc. VC/SE CNV-05-000