Performance Based Seismic Design of Reinforced Concrete Building

Similar documents
PERFORMANCE BASED SEISMIC EVALUATION OF MULTI-STOREYED REINFORCED CONCRETE BUILDINGS USING PUSHOVER ANALYSIS

OPTIMUM POSITION OF OUTRIGGER SYSTEM FOR HIGH RAISED RC BUILDINGS USING ETABS (PUSH OVER ANALYSIS)

NON LINEAR STATIC ANALYSIS OF DUAL RC FRAME STRUCTURE

Non Linear Static Analysis of Multi-storeyed Special Moment Resisting Frames

Effects of Building Configuration on Seismic Performance of RC Buildings by Pushover Analysis

International Journal of Advance Engineering and Research Development PERFORMANCE BASED ANALYSIS OF RCC BUILDING

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

International Journal of Engineering Research & Science (IJOER) ISSN: [ ] [Vol-3, Issue-3, March- 2017]

Pushover Analysis Of RCC Building With Soft Storey At Different Levels.

Comparative Study on Concentric Steel Braced Frame Structure due to Effect of Aspect Ratio using Pushover Analysis

STUDY ON ROLE OF ASYMMETRY IN PUSHOVER ANALYSIS WITH SEISMIC INTERPRETATION

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October ISSN Pushover Analysis of RC Building

APPLICATION OF PERFORMANCE - BASED DESIGN TO UPGRADE UNSYMMETRICAL RC BUILDING

Pushover Analysis of Multistoried Building

PERFORMANCE BASED ANALYSIS OF R.C.C. FRAMES

Comparative Study of Pushover Analysis on RCC Structures

Development of fragility curves for multi-storey RC structures

A Performance Based Evaluation of a Wall- Frame Structure Employing the Pushover Analysis Tool

Nonlinear Pushover Analysis of Steel Frame Structure Dahal, Purna P., Graduate Student Southern Illinois University, Carbondale

A Comparative Study on Non-Linear Analysis of Frame with and without Structural Wall System

COMPARATIVE STUDY OF REINFORCED CONCRETE SHEAR WALL ANALYSIS IN MULTI- STOREYED BUILDING WITH OPENINGS BY NONLINEAR METHODS

PERFORMANCE- BASED SEISMIC DESIGN OF A BUILDING

Seismic Damage Prediction of Reinforced Concrete Buildings Using Pushover Analysis

AN ASSESSMENT OF SAFETY OF A REAL SIX STORIED R.C.C FRAME STRUCTURE BY NON LINEAR STATIC PUSHOVER ANALYSIS

Seismic Assessment of an RC Building Using Pushover Analysis

International Journal of Intellectual Advancements and Research in Engineering Computations

Seismic performance assessment of reinforced concrete buildings using pushover analysis

Modeling of Reinforced Concrete Folded Plate Structures for Seismic Evaluation Swatilekha Guha Bodh

Evaluation Of Response Modification Factor For Moment Resisting Frames

PUSHOVER ANALYSIS FOR THE RC STRUCTURES WITH DIFFERENT ECCENTRICITY

Performance Based Seismic Design of Reinforced Concrete Building

Inelastic seismic analysis of six storey RC building

Seismic Performance of Residential Buildings with Staggered Walls

NONLINEAR STATIC ANALYSIS OF R.C.C. FRAMES (Software Implementation ETABS 9.7)

PARAMETRIC STUDY OF BEHAVIOR OF AN ELEVATED CIRCULAR WATER TANK BY NON LINEAR STATIC ANALYSIS. Prakash Mahadeo Mohite and Saurabh Arun Jangam

SEISMIC ASSESEMENT OF RC FRAME BUILDINGS WITH BRICK MASONRY INFILLS

Static Analysis of Multistoreyed RC Buildings By Using Pushover Methodology

Pushover analysis of RC frame structure using ETABS 9.7.1

Application of Pushover Analysis for Evaluating Seismic Performance of RC Building

SEISMIC VULNERABILITY OF EXISTING RC BUILDINGS IN INDIA

Analysis and Capacity Based Earthquake Resistance Design of Multy Bay Multy Storeyed Residential Building

Seismic assessment of an existing hospital

Seismic Analysis of Earthquake Resistant Multi Bay Multi Storeyed 3D - RC Frame

Non-Linear Pushover Analysis of Flatslab Building by using Sap2000

COMPARISON OF A REINFORCED CONCRETE BUILDING STRENGTHRND WITH VARIOUS METHODS

NON-LINEAR STATIC PUSHOVER ANALYSIS FOR MULTI-STORED BUILDING BY USING ETABS

Pushover Analysis of RC Frame for effective column design

Evaluation of Response Reduction Factor and Ductility Factor of RC Braced Frame

Evaluation of Response of OMF, CBF and EBF to Lateral Loads Using Nonlinear Pushover Analysis

NON-LINEAR STATIC ANALYSIS OF TEE-BEAM BRIDGE

EVALUATION OF RESPONSE REDUCTION FACTOR OF RC FRAMED BUILDINGS BY PUSHOVER ANALYSIS

Miss. Sayli S Kamble. 1, Prof. Dr. D. N. Shinde 2 1 Department of civil Engineering, PVPIT Budhgaon, Shivaji university, Maharashtra, India.

Performance Based Analysis of Concealed Beam in Reinforced Concrete Structure

International Journal of Engineering Research And Management (IJERM) ISSN: , Volume-03, Issue-11, November 2016

PUSHOVER ANALYSIS (NON-LINEAR STATIC ANALYSIS) OF RC BUILDINGS USING SAP SOFTWARE

Research Article Volume 6 Issue No. 7

Effect of Diaphragm Openings in Multi-storeyed RC framed buildings using Pushover analysis

Index terms Diagrid, Nonlinear Static Analysis, SAP 2000.

Seismic Performance of Multistorey Building with Soft Storey at Different Level with RC Shear Wall

PUSHOVER ANALYSIS OF A 19 STORY CONCRETE SHEAR WALL BUILDING

Seismic Evaluation of Infilled RC Structures with Nonlinear Static Analysis Procedures

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

PERFORMANCE BASED EVALUATION OF FRAMED REINFORCED CONCRETE SHEAR WALLS BY PUSHOVER ANALYSIS

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

Non-Linear Static Analysis of Multi Storeyed Building A Modified Approach

[Mohammed* et al., 5(8): August, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

Pushover Analysis of Reinforced Concrete Structures with Coupled Shear Wall and Moment Frame. *Yungon Kim 1)

EVALUATION OF ANALYSIS PROCEDURES FOR PERFORMANCE-BASED SEISMIC DESIGN OF BUILDINGS

Pushover Analysis of High Rise Reinforced Concrete Building with and without Infill walls

SEISMIC EVALUATION OF BUILDINGS WITH POSTTENSIONED BEAMS BY NON-LINEAR STATIC ANALYSIS

EVALUATION OF NONLINEAR STATIC PROCEDURES FOR SEISMIC DESIGN OF BUILDINGS

Seismic Performance Model of an Important Building in Peru - Evaluation of a Hospital Structure -

Behaviour of Tall Structure with Eccentric Loading

Case Study of RC Slab Bridge using Nonlinear Analysis

A Comparison of Basic Pushover Methods

Analysis the Behavior of Building with Different Soft Story

International Journal of Engineering Science Invention Research & Development; Vol. II Issue VII January e-issn:

Performance Based Seismic Design of RC Building with Consideration Of Soil Structure Interaction

Comparative Study of Multi-storeyed RC Building With Open Ground Storey Having Different Type Infill Walls

Effect of Pushover Load Pattern on Seismic Responses of RC Frame Buildings.

Pushover Analysis for an Elevated Water Tanks

Seismic Evaluation and Strengthening of RC Frames with FRP Composites

DESIGN AMPLIFICATION FACTOR FOR OPEN GROUND STOREY RC STRUCTURE WITH INFILL OPENINGS IN UPPER STOREYS

SEISMIC DEMAND STUDY OF SOFT STOREY BUILDING AND IT S STRENGTHENING FOR SEISMIC RESISTANCE

EFFECTS OF SOFT FIRST STORY ON SEISMIC PERFORMANCE OF RC BUILDINGS AND SUSTAINABLE APPROACH TO RETROFIT

PUSHOVER ANALYSIS OF UNSYMMETRICAL FRAMED STRUCTURES ON SLOPING GROUND

Damage-control Seismic Design of Moment-resisting RC Frame Buildings

PERFORMANCE ASSESMENT OF RC BUILDING FRAMES BY NON LINEAR ANALYSIS

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

EFFECT OF USER DEFINED PLASTIC HINGES ON NONLINEAR MODELLING OF REINFORCED CONCRETE FRAME FOR SEISMIC ANALYSIS

Pushover Analysis of G+15 Steel and Steel-Concrete Composite Frame Structure

SEISMIC EVALUATION OF R.C.C FRAME BUILDINGS WITH LINEAR AND NON LINEAR STATIC ANALYSIS

Egyptian Code Seismic Load Design Provisions for Moment Resisting Frames

OPTIMUM LOCATION OF RC SHEAR WALL FOR A FIVE STOREY SYMMETRICAL FRAMED STRUCTURE FOR EFFICIENT SEISMIC DESIGN USING PUSHOVER ANALYSIS

STRUCTURAL DESIGN REQUIREMENTS (SEISMIC PROVISIONS) FOR EXISTING BUILDING CONVERTED TO JOINT LIVING AND WORK QUARTERS

International Journal of Advance Engineering and Research Development A REVIEW ON PERFORMANCE BASED PLASTIC DESIGN METHODOLOGY

Analytical Studies on Effect of Brick Elemental Properties on Static Pushover Analysis of Multi-Storey Frame

ANALYSIS PROCEDURES FOR PERFORMANCED BASED DESIGN

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Seismic Response of RC Building Structures using Capacity Spectrum Method with included Soil Flexibility

Transcription:

Open Journal of Civil Engineering, 2016, 6, 188-194 Published Online March 2016 in SciRes. http://www.scirp.org/journal/ojce http://dx.doi.org/10.4236/ojce.2016.62017 Performance Based Seismic Design of Reinforced Concrete Building Dilip J. Chaudhari, Gopal O. Dhoot * Applied Mechanics Department, Government College of Engineering, Amravati, India Received 6 February 2016; accepted 27 March 2016; published 30 March 2016 Copyright 2016 by authors and Scientific Research Publishing Inc. This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/ Abstract In past two decades earthquake disasters in the world have shown that significant damage occurred even when the buildings were designed as per the conventional earthquake-resistant design philosophy (force-based approach) exposing the inability of the codes to ensure minimum performance of the structures under design earthquake. The performance based seismic design (PBSD), evaluates how the buildings are likely to perform under a design earthquake. As compared to force-based approach, PBSD provides a methodology for assessing the seismic performance of a building, ensuring life safety and minimum economic losses. The non-linear static procedures also known as pushover analysis are used to analyze the performance of structure under lateral loads. Pushover analysis gives pattern of the plastic hinge formations in structural members along with other structural parameters which directly show the performance of member after an earthquake event. In this paper, a four-storey RC building is modelled and designed as per IS 456:2000 and analyzed for life safety performance level in SAP2000 v17. Analysis is carried out as per ATC 40 to find out storey drift, pushover curve, capacity spectrum curve, performance point and plastic hinges as per FEMA 273 in SAP2000 v17. From the analysis, it is checked that the performance level of the building is as per the assumption. Keywords PBSD, Performance Level, Pushover Analysis, Performance Point, Plastic Hinge 1. Introduction As per the conventional earthquake-resistant design philosophy, the structures are designed for forces which are much less than the expected design earthquake forces. Hence, when a structure is struck with severe earthquake * Corresponding author. How to cite this paper: Chaudhari, D.J. and Dhoot, G.O. (2016) Performance Based Seismic Design of Reinforced Concrete Building. Open Journal of Civil Engineering, 6, 188-194. http://dx.doi.org/10.4236/ojce.2016.62017

ground motion, it undergoes inelastic deformations. Even though the structure may not collapse, the damages can be beyond repairs. These methods usually don t consider the expected performance level and seismic risk levels of the structure after an earthquake event. Since, these methods give high base shear, high ductility demand and also don t give the actual performance of structure after an earthquake event need of new method comes which would give the actual performance of the structure after an earthquake event. 2. Literature Survey The literature shows considerable research in PBSD. This research is reviewed keeping in view the methodology, principles and various aspects of PBSD. Some of related works are discussed below. Seismic evaluation and retrofitting of concrete buildings are studied considering seismic safety and re-strengthening [1]. Also pre-standard and commentary for the Seismic Rehabilitation of Buildings are provided by ASCE FEMA repost where provisions are given for the same [2]-[4]. This paper outline and compares the three methods along with discussion in the context of traditional force based seismic design and earlier design approaches of performance based design. Factors defining different performance states were discussed including the need to include residual displacement as a key performance limit. Sashi K. Kunnath (2006), conducted study on seismic design and evaluation of building structures using PBSD. Deterministic approach and probabilistic approach is discussed in which capacity spectrum method from ATC-40 and standard pushover analysis from FEMA 356 is in brief. Comparative study of ATC-40 and FEMA 356 is done (Farzad Naeim, Hussain Bhatia, 2008). This paper provides a basic understanding of the promises and limitations of performance based seismic engineering. The state-of-the-art methodologies and techniques embodied in the two leading guidelines on this subject ATC-40 and FEMA 273/274 are introduced and discussed. Numerical examples are provided to illustrate the practical applications of the methods discussed (Vivinkumar, R.V., 2013). This study explains about two major seismic design methods (i.e.) Force based design and direct displacement based design in which former is a conventional method while later one is a performance approach of design. Design and analysis were done on two dimensional bare frames of four, eight and twelve stories based on following codes IS 456, IS 1893:2000, FEMA 356 and the two design approaches were studied [5]. 3. System Development 3.1. Performance Based Seismic Design Performance based seismic design is a process of designing new buildings or seismic up-gradation of existing buildings, which includes a specific intent to achieve defined performance objectives in future earthquakes. Performance objectives relate to expectations regarding the amount of damage a building may experience in response to earthquake shaking and the consequences of that damage. Performance objectives are operational (O), immediate occupancy (IO), life safety (LS), collapse prevention (CP), in which Life safety is the major focus to reduce the threats to the life safety of the structure in Figure 1. Performance based design approach in which performance levels are described in terms of displacement as damage is better correlated to displacements rather than forces. The fundamental goal of PSBD is to obtain a Figure 1. Different performance levels. 189

structure which will reach a target displacement profile when subjected to earthquakes consistent with a given reference response spectrum. The performance levels of the structure are governed through the selection of suitable values of the maximum displacement and maximum inter storey drift. Figure 2 shows the typical process of design is to be followed. 3.2. Capacity Response Spectra The conventional response spectrum is represented by the acceleration versus period relationship for different damping levels. In the capacity response spectrum format, the period axis is converted in the displacement axis. The structure period T is represented by radial lines, instead of being the horizontal axis. The advantage of this representation is that both strength and displacement demands are evident in a single graph. The elastic displacement demand and the structure period may be determined for elastic forces. Considering the inelastic behaviour, the inelastic displacement at the reduced force is obtained in the horizontal branch of the capacity curve corresponding to the intersection with inelastic reduced spectra. At the same time, the reduced period due to inelastic deformation may be determined. Another advantage of this representation is that both earthquake demands and structure capacity may be compared directly from the same figure. 3.3. Structural Model Development In the present work, a four storey RC frame building situated in zone IV is taken for the purpose of study. It consists of 2 bays of 5 m each in X-direction and 2 bays of 4 m each in Y-direction. The total height of the building is 14 m. The building is modelled and designed as per IS 456:2000 in SAP 2000 v17. Material Properties: Grade of Concrete: M 25 Grade of Reinforcing Steel: Fe-415 Elastic Modulus = 5000 f ck 0.5 Sectional Properties: Size of Beam = 350 mm 500 mm Size of Column = 350 mm 350 mm Thickness of Slab = 125 mm Tensile Strength = 0.7 f ck 0.5 Loading Considered: Dead Load: a) Roof Level: Weight of Slab = 3.125 kn/m 2 Weight of F.F. = 3.2 kn/m 2 b) Floor Level: Weight of Slab = 3.125 kn/m 2 Weight of F.F. = 2.260 kn/m 2 Weight of Partition Walls = 1.5 kn/m 2 Figure 2. Flowchart of performance based design process. 190

Seismic Properties (as per IS 1893:2002 part 1): Zone Factor = 0.24 Response Reduction Factor = 5 Soil Profile Type = II Importance Factor = 1 Assumptions: 1) All columns supports are considered as fixed at the foundation. 2) Plastic hinges are assigned to all the member ends. In case of columns PMM hinges (i.e. Axial Force and Biaxial Moment Hinge) are provided at both the ends, while in case of beams M3 hinges (i.e. Bending Moment Hinge) are provided at both ends. 3) The maximum target displacement of the structure is kept at 4.0% of the height of the building (4.0/100) 14 = 0.56 m = 560 mm. 4. Performance Analysis The seismic performance of a building is evaluated in terms of pushover curve, performance point and plastic hinge formation [6] [7]. 4.1. Pushover Analysis An incremental static analysis used to determine the force displacement relationship or the capacity curve for a structure in Figure 3. The analysis involves applying horizontal loads, in a prescribed pattern to a computer model of the structure incrementally and plotting the total applied shear force and associated lateral displacement at each increment until the structure reaches a limit state or collapse condition. From Table 1 it is seen that performance point lies in between step 6 and step 7. It is also seen that all hinges are within assumed performance level life safety. 4.2. Capacity Demand Spectrum Capacity demand spectrum is the representation of structures ability to resist the seismic demand. The point of intersection of capacity spectrum and demand spectrum is required performance point. Figure 4 shows the capacity spectrum curve as per ATC-40. Table 2 shows the performance point in terms of different structural parameter like base shear (V), displacement (D), spectral acceleration (Sa), spectral displacement (Sd), effective time period (T eff ), effective damping (β eff ). 4.3. Inter Storey Drift The inter storey drifts corresponding to the displacement profiles are shown in Figure 5. The limiting value of inter storey drift is 0.4% as per IS 1893:2002. For building under consideration inter storey drift is within permissible limit satisfying the displacement requirements. Hence, the building performance is satisfactory. Figure 3. Pushover curve. 191

Table 1. Pushover analysis details. Case Step Displ. (m) Base Force (kn) A to B B to IO IO to LS LS to CP Total PUSH 1 0.0001732 0 168 0 0 0 168 PUSH 2 0.02009 364.022 167 1 0 0 168 PUSH 3 0.031053 496.87 153 15 0 0 168 PUSH 4 0.043831 563.203 140 28 0 0 168 PUSH 5 0.049097 576.255 136 32 0 0 168 PUSH 6 0.05243 579.713 133 35 0 0 168 PUSH 7 0.075307 583.028 133 33 2 0 168 PUSH 8 0.108978 609.944 125 25 18 0 168 PUSH 9 0.11679 609.934 125 22 21 0 168 PUSH 10 0.12506 614.902 120 27 21 0 168 Table 2. Capacity spectrum method outputs. Performance Point SAP Output Performance Point (V, D) (581.33, 0.064) Performance Point (S a, S d ) (0.284, 0.053) Performance Point (T eff, β eff ) (0.867, 0.229) Figure 4. Capacity spectrum curve. 4.4. Plastic Hinge Results The sequence of plastic hinge formation and state of hinge at various levels of building performance is obtained from SAP output as shown in Figure 6. All the hinges are within required performance levels. Since no hinge is 192

Figure 5. Inter storey drifts. Figure 6. Plastic hinge formations. Table 3. Target roof displacement ratios at various performance levels. Performance Level Operational IO LS CP Lateral Drift Ratio (δ/h)% 0.37 0.7 2.5 5 δ = Lateral Roof Displacement; h = Total Height of Building. going in collapse prevention range designed building is safe for design basis earthquake and life safety performance level is achieved. Plastic hinge results give the information about the weakest member and so the one which is to be strengthened to achieve required performance level. Accordingly the detailing of the member can be done in order to achieve the desired pattern of failure of members in case of severe earthquakes. 4.5. Performance Based Design Specified deformation states are often taken as a measure of building performance at corresponding load levels. Federal Emergency Management Agency [FEMA] identifies the operational, IO, LS, CP performance levels and adopts the roof level lateral drift at the corresponding load levels as a measure of the associated behavior states of the building. Table 3 shows the target roof displacement ratios at various performance levels where the target 193

roof displacements are provided in terms of lateral drift ratio. For Immediate Occupancy, Target roof displacement = 0.007 14 = 0.098 m = 98 mm. Similarly for Life Safety, Target roof displacement = 0.025 14 = 0.350 = 350 mm. By analysis, roof displacement achieved = 149.298 mm. Thus, by this design building lies in between immediate occupancy and life safety range. So, the required performance objective of design is achieved. 5. Conclusions 1) The need for performance based seismic engineering in contrast to force-based design approaches as studied and the four building performance levels namely operation, immediate occupancy, life safety and collapse prevention were studied. In performance based design, multi-level seismic hazards are considered with an emphasis on the transparency of performance objectives, thus ensuring better performance and minimum life-cycle cost. 2) It has been recognized that the story drift performance of a multi-story building is an important measure of structural and non-structural damage of the building under various levels of earthquake motion. Storey drift requirement specified by FEMA 273 is satisfied for building under consideration. Thus the global performance of the building was considered as satisfactory for design objective. 3) Performance based seismic design provides reliable methodology for seismic up-gradation or for retrofitting of the existing building to achieve required performance objectives. 4) Pushover analysis is a reliable method in determination of the sequence of yielding of the components of a building, possible mode of failure, and final state of the building after a predetermined level of lateral load sustained by the structure. References [1] Applied Technology Council (1996) Seismic Evaluation and Retrofitting of concrete Buildings, ATC-40. Volume 1 and 2, Seismic Safety Commission, Redwood City, 1-346. [2] Federal Emergency Management Agency (1997) NEHRP Guidelines for the Seismic Rehabilitation of Buildings. Report FEMA-273, Federal Emergency Management Agency, Washington DC. [3] ASCE (2000) Prestandard and Commentary for the Seismic Rehabilitation of Buildings. FEMA 356 Report, American Society of Civil Engineers for the Federal Emergency Management Agency, Washington DC. [4] Priestley, M.J.N. (2003) Performance Based Seismic Design of Concrete Buildings. Bull. NZSEE. (In Press) [5] Kunnath, S.K. (2006) Study on Seismic Design and Evaluation of Building Structures Using PBSD. CRC Press, Taylor & Francis Group, Boca Raton. [6] Naeim, F. and Bhatia, H. (2008) The Seismic Design Handbook. 2nd Edition, Springer Publication, Berlin, 757-792. [7] Khan, R.A. (2014) Performance Based Seismic Design of Reinforced Concrete Building. International Journal of Innovative Research in Science, Engineering and Technology, 3, 13495-13506. 194