Eziform Ridge Vent Natural Roof Ventilators

Similar documents
Eziform Half Round Gutter

Stramit Patio Roofing Cyclonic Span Tables

BUILDING PRODUCTS LCP K-CLAD. Metal Roof & Wall Cladding System

Superdek DESIGN GUIDE

METLOK 700 DESIGN & INSTALLATION GUIDE CONCEALED FIX ROOF SYSTEM. A Met-TECH GUIDE

METLOK 700 DESIGN & INSTALLATION GUIDE CONCEALED FIX ROOF SYSTEM. A Met-TECH GUIDE

BUILDING PRODUCTS LCP KLIPDECK. Metal Roof & Wall Cladding System

Cyclonic Areas Roof & Wall Cladding

ROOFING & SHEET METAL MANUFACTURERS

ROOFING & SHEET METAL MANUFACTURERS

FLATDEK II DESIGN AND INSTALLATION GUIDE

Architectural Roofing

LCP MULTIDECK. Metal Roof & Wall Cladding System

Architectural Roof Products Guide Specifications

Architectural Roof Products Guide Specifications

ABSeam Panel Overview and Installation Instructions

Lysaght Klip-lok Maxima Concealed-fixed deck with extra wide coverage. Klip-lok Maxima Available in WA only.

STRAMIT CapacityPLUS 660 DEEP ROOF CLADDING

SPANDEK. Design & Installation guide. LYSAGHT SPANDeK

Custom Orb Accent 35. Corrugated steel cladding optimised for commercial applications

range of colours in COLORBOND factory pre-painted steel and in unpainted

INTEGRITY 820. Design and installation guide. integrity 820

spandek optima LYSAGHT Trapezoidal steel cladding with longer spanning capability BlueScope LYSAGHT SINGAPORE roofing & walling Solutions

Custom Orb Accent 21. Deeper, stronger corrugated steel cladding. CUSTOM ORB ACCENT 21 is ideal for traditional or contemporary design

TRIMDEK. design and installation guide. lysaght trimdek

ABS Pre-Fab Building S ystem

SPECIFICATION. ~ (project name) ~ (project address) ~ (owners name)

STRAMIT MONOCLAD ROOF AND WALL CLADDING

New versatile and effective dry fix solutions for the roofline and above

INSTALLATION MANUAL Heritage Series

Guidance document January 2015

TRIMDEK Subtle Square Fluted Steel Cladding

Lysaght Custom Orb. Custom Orb. Traditional corrugated steel cladding. Colours

Installation Guide. PAROC panel solutions

SPECIFICATIONS FOR PROPOSED

05 Roofing, Roof Fabric & Roof Safety

Architectural Roof and Wall Products Guide Specifications

Klip-lok Classic 700. Concealed-fixed steel cladding

JUNIOR HF Steel Roof Panels

Architectural Roof and Wall Products Guide Specifications

ARCADIA SPUR FIXED LOUVRE SYSTEM 2017 ARCADIA GLOBAL PTY. LTD.

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

STRAMIT SPEED DECK ULTRA

maxispan Practical commercial roofing & cladding solutions innovative products

Mega 5. Specific Profile Data Sheet BACK. Table of Contents. Technical Drawing File Downloads

Siding and Soffit Installation Guidelines

CUSTOM ORB ACCENT 35 DESIGN AND INSTALLATION GUIDE

ALLMET CONTINENTAL INSTALLATION GUIDE

STRAMIT MONOCLAD ROOF AND WALL CLADDING MON

Hi Five. Specific Profile Data Sheet BACK. Table of Contents. Technical Drawing File Downloads

Coated steel products for corrosive environments.

Architectural Wall Products Guide Specifications

ONDULINE MINI 18. The stylish Do it Once roofing upgrade for your garden buildings.

SMART ROOFS AFFORDABLE HOUSING LEISURE HOUSING STORAGE BUILDINGS BARNS GARAGES & CARPORTS GARDEN OR WOOD SHEDS.

SECTION STAINLESS STEEL WALL PANELS

ever before. The smaller number of clips for a given area provides extra economy.

CUSTOM ORB ACCENT 21 DESIGN AND INSTALLATION GUIDE

SPANDEK DESIGN AND INSTALLATION GUIDE

INSTALLATION GUIDE.

SECTION PRE-ENGINEERED EXTRUDED ALUMINUM DECKING WALKWAY COVERS SPECIFICATION

TRIMDEK DESIGN AND INSTALLATION GUIDE

GM-CM30078-RevA. Metalcraft Insulated Panel Systems I Specification Guide V1 NZ I June

SPANDEK DESIGN AND INSTALLATION GUIDE

Pacific Tile Counter Batten and Batten

Pacific Tile Counter Batten and Batten

RESIDENTIAL LIGHT GAUGE APPLICATION GUIDE

Product Data Sheet (rev c 16/7/15) Product: BENCHMARK Roofliner System

CONTINUOUS VENTILATORS

BARREL VAULT Tile Counter Batten and Batten Installation Guide

TATA BLUESCOPE STEEL LIMITED PRODUCT SPECIFICATION LANGUAGE FOR PRE ENGINEERED STEEL BUILDING (BUTLER BUILDING SYSTEM- WITH MR-24 ROOF SYSTEM)

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate knowledge of metal roof and wall cladding systems

INSTALLATION GUIDE COMPOSITE DECKING

DL-200. Specifications

Classic and NB Tile Counter Batten and Batten

Siding and Soffit Installation Guidelines

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5

1XH Monoclad 8pp 2001.art 22/4/02 10:58 AM Page 1 STRAMIT MONOCLAD ROOF AND WALL CLADDING MON

Clenergy ezrack SolarRoof Code-Compliant Planning and Installation With Australia AS/NZS1170

Standing Seam Installation Guide

Steel Floor Framing Solutions

KLIP-LOK 406 DESIGN AND INSTALLATION GUIDE

YOU BRING THE PASSION, WE'LL BRING THE FLAT & GABLE SHEDS DOMESTIC RURAL INDUSTRIAL

SECTION PRE-ENGINEERED METAL BUILDING

klip-lok 700 HI-STRENGTH

BUILDING PRODUCTS LCP SPANLOCK. Metal Roof & Wall Cladding System

Cavity Tray Application

SSL-175. Specifications

Architectural Roof & Wall Products Guide Specifications MANUFACTURER KLOECKNER METALS KALAELOA BLVD, KAPOLEI, HI 96707,

Trough Section Roofing & Cladding

Fundamentals of Insulated Panel Installation. MBCEA 2016 Clearwater, FL

Foundations. Issue. Slab-On-Grade Liquid Water Control (See Figure 2-2) Goals. Guidance

FUNCTIONAL REQUIREMENTS

Trimform for panels, purlins & gutters. No obligation consultation

Custom Orb Custom Blue Orb

CS-100 Guide Specifications

SECTION HVAC GRAVITY VENTILATORS

Global Roofing Solutions Zip-Tek 420

DuraComp Composite Decking Installation Guide. Hidden Plastic Clip Fixing

Louvres ACOUSTIC LOUVRES TO SUIT ALL BUILDING TYPES

Product Data Sheet. Product: Benchmark Wall Liner System

Transcription:

Eziform Ridge Vent Natural Roof Ventilators 1

Eziform Ridge Vent Natural Roof Ventilators Eziform Ridge Vents from Eziform Sheet Metal provide an economical, effective and low maintenance method of exhausting heat, moisture and air-borne contaminants from industrial and commercial buildings. By taking advantage of natural thermodynamic forces, ridge ventilators offer a sustainable solution to improving energy efficiency, without moving parts. Eziform Ridge Vents are ideally suited to the extraction of low to medium heat loads, with virtually no running costs or maintenance. Natural ventilation low running expenses Efficient air flow cooler building One-piece brackets easy installation Knockdown form cost-effective, damage resisting Extensive size range suits most designs No moving parts low maintenance Compound design resists rainwater entry Self draining no additional plumbing Mesh guarding provides bird and vermin barrier Eziform Ridge Vents are suitable for use in light and moderate factory, shed and storage facilities with non-corrosive ridge ventilation needs. 2

Selection & Specification Materials Components for Eziform Ridge Vents are supplied as coated steel products. Coated sheet product is manufactured from material conforming to AS1397. External components are supplied in a pre-painted or zincaluminium finish to suit the project. For sizes 750mm and above, the external side cladding can be provided in a comprehensive range of pre-painted colours as standard. Non-ferrous cladding materials such as aluminium and stainless steel are also available. Adverse Conditions Eziform Ridge Vents offer excellent durability in benign locations. Do not use in marine or heavy industrial environments or applications where corrosive or above ambient humidity air will be discharged. Compatibility All building products need to be checked for compatibility with adjacent materials, whether they are part of the current project or pre-existing or planned building elements. Avoid placing Eziform Ridge Vents on or in conjunction with components made from copper, lead, green or treated timber, stainless steel and mortar or concrete. Contact Eziform Sheet Metal for more detailed information. Architectural Specification This specification may be used to ensure that required performance and functional needs are met: The venting shall be Eziform Ridge Vents in m length/s with a throat width of mm (300/450/600/750/900/1200) and for a roof slope of degrees. Sheet materials shall be protected steel sheet to Australian Standard AS1397, with a minimum AZ150 zinc-aluminium or Z275 zinc coating with or without an oven-baked paint film of selected colour. The assembly shall be fixed to the purlins/girts in accordance with the manufacturer s recommendations. Suitable fixing screws in accordance with Australian Standard AS3566, Class 3 minimum, shall be used at each connection. Flashing shall be supplied in compatible materials as specified. All components shall be fixed in a workman-like manner, leaving the job clean and weathertight. Minor blemishes should be repaired with touch-up paint supplied by the roof manufacturer. All debris (nuts, screws, cuttings, filings, etc.) shall be cleaned off daily. 3

Standards Eziform Ridge Vents have been independently tested to: AS2428.5-2004 Methods of testing smoke/heat release vents: Discharge coefficient and effective aerodynamic area AS4740:2000 Natural Ventilators Classification and Performance, Appendix D and E Design Eziform Ridge Vents are only intended for installation along the ridgeline of a roof. It is possible to specify and install the vent as a continuous unit, therefore it should be considered whether access from one side of the roof to the other is required. This could be achieved by specifying more than one unit within the roof length, leaving access at one or more ends or by the use of access ladders or walkways. Sizes A Vent Size (Throat) E C A Top flange of roof purlin must be fixed between dimensions A and E, as close as possible to opening. (Bracing members not shown for clarity.) Eziform Ridge Vents Dimensions (mm) B Unit Height C Unit Width Side Cladding D Maximum Frame Spacing E Flange Length 300 400 700 Flat sheet 1350 300 450 600 1050 Flat sheet 1200 400 600 780 1400 Flat sheet 1200 400 750 950 1800 Longspan* 1200 475 900 1130 2200 Longspan* 1200 600 1200 1490 2860 Longspan* 1500 750 * Stramit Longspan sheeting Eziform Ridge Vents Mass Vent Size (Throat) Frame Spacing Vent Mass (kg/m) 300 1350 17 450 1200 24 600 1200 31 750 1200 39 900 1200 54 1200 1500 74 B Spacing/Support Eziform Ridge Vent frames must be installed at the spacings given in dimension D of the table at left, or less. Purlins must be positioned to allow attachment of the frame on the purlin flanges as defined by dimension E. Designers are reminded to allow for point loadings applied to the purlins for both dead and wind loadings. The use of Stramit EX-facta purlin software will make this task easier. Wind Pressures The behaviour of Eziform Ridge Vents was analysed independently to determine the adequacy of the structural frames and to determine the reaction forces that are applicable to the rest of the structure. This analysis has been completed for non-cyclonic Regions A and B, as well as cyclonic Region C. Eziform Ridge Vents Wind Loadings Wind Region A B C Wind Speed (m/sec) 50 61 66 Basic Wind Pressure (kpa) 1.75 2.6 3.0 This table assumes vents will only be installed on industrial type, importance level 2 buildings with a roof pitch of 10 degrees or less, up to 10 metres high. Other Cyclonic Areas Eziform Ridge Vents have not yet been verified for use in Region D. Foot Traffic Standing or walking on Eziform Ridge Vents is not recommended, as this could be unsafe and may cause superficial or visual damage to the vents. Ventilation Ventilation through the Eziform Ridge Vent is passive, therefore performance will vary and will be highly dependent on building geometry, internal building use and weather conditions. The cooling benefits of passive venting are universally recognised and Eziform Ridge Vents have been independently tested to determine airflows under a variety of conditions. Exhaust Performance The performance of any ridge ventilator will depend on the throat size of the vent, the height of the structure to the top of the vent, the inlet height (assumed to be half the door or inletvent height above the floor) and the temperature difference between the outside and inside of the building. These parameters are included in the ridge vent performance graph at right. 4

Design Procedure To determine the vent size required the following procedure should be followed. 1. Determine the stack height (distance from inlet to the top of the vent in metres). 2. Find the temperature difference inside to outside of the building in degrees Centigrade. 3. Find the average building height [(ridge + eaves height) / 2] and multiply this by the building width. Lengths are in metres. 4. Select the number of air changes required per hour to suit the use of the building. Multiply the answer to item 3 by the number of air changes, and plot this on the y-axis. 5. Multiply the stack height by the temperature difference, and plot this on the x-axis. 6. The intersection of the plot lines gives the size of the required Eziform Ridge Vent. This procedure determines the vent size for an installation along the full building length. If only partial length vents are to be used, designers should modify the building volume in inverse proportion to the percentage of ridge vent proposed. Design Example A warehouse building, 100 metres long and 30 metres wide, is to be fitted with Eziform Ridge Vents. The eaves height is 6 metres and roof pitch is 3 degrees. The warehouse has many open access doors along its sides, but because of insulation in the roof, it is thought that the temperature difference could be about 9 degrees. Using 4 vents, installed in 20 metre lengths with equidistant spacings between, determine the vent size required. 1. Determine the stack height. Eaves height = 6m, Roller doors = 4m (Inlet height = 2m) Roof pitch = 3 degrees Roof rise = (bldg wdth/2) x tan roof pitch = 0.78m Assume vent size of 600 mm Vent height = 0.78m Stack height = 4 + 0.78 + 0.78 = 5.6m (approx.) 2. Temperature difference = 9º 3. Average bldg ht = (6 + 6.8)/2 = 6.4m Modify building width to allow for 80m of vent. Modified width = 30 x 100 / 80 = 37.5 Building volume = 6.4 x 37.5 = 240m 3 4. Air changes per hour = 5 Y axis plot = 1200 5. X axis plot = 50.4 6. Solution is a 900mm vent running 80% of the building length. An alternative solution could be a 600mm vent running the full length of the building. Ridge Vent Exhaust Performance Exhaust capacity per metre length (m 3 /hr) 2800 2600 2400 2200 2000 1800 1600 1400 1200 1000 800 600 400 200 0 0 10 20 30 40 50 60 70 80 90 100 100 120 130 140 150 Temperature difference (deg C) x stack height (m) Design Example Alternative Design Vent Size (mm) 1200 900 750 600 450 300 Exhaust capacity per metre length (m 3 /hr) = building width x height x number of air changes per hour 5

Air Changes per Hour The building use and the building designers will determine the number of air changes required. Typical values are: Building Use Air Changes/Hour Warehouse 5 Poultry Shed 8 Light Manufacturing 10 Plant Building 12 Assembly Hall 15 Kitchen 20 Purlin Loads In addition to the dead loads caused by the mass of the ridge vent, designers need to consider the effect of the wind reaction loads on the purlin design and specify adequate fasteners. Based on the wind and frame details outlined above, the reaction loads at each fixing point are given in the following table. Region A Region B Region C Vent Reactions (kn) Size Horiz Vert Horiz Vert Horiz Vert 300 0.62 0.47 0.93 0.71 1.07 0.81 450 0.86 0.65 1.28 0.96 1.47 1.11 600 0.54 0.73 0.80 1.08 0.92 1.25 750 0.79 1.09 1.17 1.62 1.35 1.87 900 0.95 1.24 1.40 1.84 1.62 2.12 1200 1.58 1.88 2.34 2.79 2.70 3.22 These loads may vary with frame spacing and local conditions. Fastener Specification Fasteners to attach frames to the ridge purlins must be designed to suit individual projects, allowing for variations in purlin thickness and fastener configuration. Procurement Prices of Eziform Ridge Vent and accessories can be obtained from Eziform Sheet Metal or any distributor of Stramit products. Eziform Ridge Vents are supplied in knockdown form, ready for assembly, and are custom made to suit the length of vent required. When designing or transporting long products, ensure the length is within the limit of the local transport authority regulations. Manufacturing tolerance on the length of components supplied is +0-15mm. Stramit Longspan sheeting, used as side panelling for 750/900/1200 Eziform Ridge Vents, is supplied up to 8 metres (maximum length of vent module). Allow 100mm for overlaps if multiple sheets are to be used in a continuous vent. Flashing, trays and capping are generally supplied in specified lengths up to a maximum length of 8 metres. Ordering Eziform Ridge Vents can be ordered directly, through distributors, or supplied and fixed by a roofing contractor. Delivery/Unloading Delivery can normally be made within 14 days ex-brisbane, subject to delivery location, quantity and material availability, or can be pre-arranged. Please ensure that suitable arrangements have been made for truck unloading, as this is the responsibility of the receiver. Pack mass may be up to one tonne. When lifting Eziform Ridge Vent components, care should be taken to ensure that the load is spread to prevent damage. Handling/Storage Eziform Ridge Vent components and assemblies should be handled with care at all times to preserve the product capabilities and quality of the finish. Packs should always be kept dry and stored above ground level while on site. If the materials become wet, they should be separated, wiped and placed in the open to promote drying. Misting During wet weather, with high winds and driving rain, misting can sometimes be created by negative internal pressures. This can be controlled with adequate wall ventilation to balance internal and external air pressures. 6

Installation Site Induction Consideration should be given to including vent ridges as part of roof and wall handling and installation in site induction safety procedures. Specific consideration should be given to handling, avoidance of cuts, trips, slips and falls, sheet handling (particularly in windy conditions), sheet cutting procedures and surface temperature (on sunny days). Insulation Eziform Ridge Vent is suitable as specified for use in roofs with insulating blanket up to 50mm. Increased thicknesses require longer fasteners and greater care in installation. The throat area of the vent must remain clear of insulating material. Installation Sequence All orders are delivered with an assembly guide and components list. Eziform Ridge Vents can be installed using the following sequence: Walking As with all roofing products, extra caution is recommended when walking on the roof. Always wear flat rubber soled shoes and place feet only in the pans of rib/pan profiles, taking care to avoid the last pan or two near edges of the metal roof area. Do not walk on the roof vent itself. Good Practice Eziform Sheet Metal recommends that good trade practice be followed when using this product, such as that found in Australian Standards Handbook HB39. Cutting Should cutting be required, use a power saw with a steel cutting blade or a power nibbler and, for localised cutting, tin snips. Avoid the use of abrasive discs as these can cause burred edges and coating damage. Please dispose of off-cuts carefully. 300mm to 1200mm Series Vents 1. Fix one frame at each end of the opening using four No 14 x 22mm screws (non-cyclonic areas) or other fasteners as specified by the engineer. The base of each frame must either be fitted under the roof sheet directly on to the purlin, or in the pan of the roof sheeting. Do not install on top of roof ribs. 2. Align and space the remainder of the frames, ensuring that the lap join for the cover panels is on a frame. Fix as per step 1. 3. Loosely fit the apron flashing to both sides of the vent. Scribe the turn down to the roof profile. 4. Fit the internal ridge flashings using 10 x 16mm screws at maximum 150mm centres. 5. The internal gutter channel (supplied with 600, 750, 900 and 1200 vents) are fitted at every second frame. To fit the internal downpipe, cut the ridge capping and slide the channel through the space in the bracket. Fix and seal the downpipe channel to ridge capping. 6. Fit the lower mesh to the lower outer edge of the frame using 10 x 16 wafer tek screws. Then scribe the apron edge of the mesh to match the profile of the roof. Other Products Eziform Sheet Metal offers a wide range of purpose fabricated roofing accessories in stainless steel, coated steel, aluminium and copper, including: Custom Ridge Capping Half-Round Gutters Custom Fabricated Gutters Stainless Steel Box Gutters Fascia Gutter and Brackets Downpipes Rainwater Heads Commercial Flashing 7. (300-600 Series Vents). Fit the top and side flashing with 10 x 16mm screws at maximum 150mm centres, ensuring the lower mesh is tucked behind the side cover. 8. (750-1200 Series Vents). Fit the top flashings and the Stramit Longspan cladding to the sides of the frames using 10 x 16mm screws at maximum 150mm centres. 9. Fit the upper mesh between the two edges of the top flashing. Notes All laps are to be silicone sealed. For installation in cyclonic areas all No 10 x 16mm screws are to be replaced with No 12 x 20mm screws. Installation procedures are to follow all workplace health and safety requirements. Screws not supplied with kit. The information contained in this brochure is as far as possible accurate at the date of publication. However, before application in a particular situation, Eziform Sheet Metal recommends that qualified expert advice be obtained confirming the suitability of the product(s) and information in question for the application proposed. While accepting its legal obligations, Eziform Sheet Metal disclaims all liability (including liability for negligence) for all loss and damage resulting from the use of the information provided in this brochure. 7

Eziform Sheet Metal 41 Parramatta Road, Underwood, Qld 4119 Phone: 07 3208 0660 Fax: 07 3808 2928 sales@eziform.com.au Trade marks of Stramit Corporation Pty Limited ABN 57 005 010 195 Trading as Eziform Sheet Metal. A member of the Fletcher Building Group. Stramit Corporation Pty Limited, March 2011