INSTRUCTIONS & CALIBRATION PHOTOBOOK

Similar documents
DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD

BIOSCAN* ATP method for monitoring of biofilm/sessile microorganisms in cooling systems

MICkit Pipe Inspection Kit

MICkit Pipe Inspection Kit For the Physical Inspection of Pipe in Fire Protection Systems (FPS)

Silage DNA extraction procedure

BIOSCAN* ATP method for biocide (toxicant) evaluations

Oxygen Demand, Chemical

Collecting a Surface Water Sample

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement

Measuring Dissolved Oxyg Instructions for the La Motte Field-Test Kit

EXPERIMENT 7A. Chemical Separation by Filtration and Recrystallization INTRODUCTION

Method 8017 (0.7 to 80.0 µg/l) Powder Pillows. Scope and Application: For water and wastewater; digestion is required to determine total cadmium.

Polymer Block Cleaning Kit

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Oxygen Demand, Chemical

CHEMetrics, Inc. Indigo Ozone Vacu-vials Technical Data Summary

Experiment 2: The Chromatography of Organic Compounds

Overview. Learning Objectives: This module provides step-by-step instructions in how to do the Bulk Density Protocol.

AES-v-RCF solubility test kit get a fast and clear diagnosis

ecry3.1ab ELISA Kit DAS ELISA for the detection of ecry3.1ab protein Catalog number: PSP 49000

Human DNA Alu Amplification by Polymerase Chain Reaction (PCR)* Laboratory Procedure

Experiment 21 - Solubility and Molecular Structure

Direct ISE Method Method to 4.00 mg/l NO 3 N Nitrate ISE

Wipes for Disclosing the Presence of Lead

Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Pour-Thru Cell

Specific Heat. q = csm T (1)

CHM Gravimetric Chloride Experiment (r7) 1/5

FIELD PROCEDURE: TURBIDITY

Forensics with TI-Nspire Technology

Phosphorus, Reactive (Orthophosphate)

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1122 DETERMINING SULFATE CONTENT IN SOILS. July 17, 2015

Making Saline SOLUTION. Lab Number 2 Part 1

Bt-Cry1F ELISA Kit Qualitative DAS ELISA for the detection of the Bt-Cry1F transgenic protein Catalog number: PSP 10301

Collecting a Surface Water Sample

Technical Manual No Version

Copper Odyssey. Chemical Reactions of Copper

1. Determine the mass of each element in a sample of the compound

EXPERIMENT 5 Chemistry 110 COMPOSITION OF A MIXTURE

Evaluation Report of

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised January 2017

QuickTox Kit for Fumonisin

Eutrophication Using Up Oxygen In Water

Safe Pesticide Practices

Bt-Cry1F ELISA Kit Quantitative DAS ELISA for the detection of the Bt-Cry1F transgenic protein Catalog number: PSP 11700

EXPERIMENT. The Reaction of Magnesium with Hydrochloric Acid; The Molar Volume of Hydrogen

1. Acid Rain and Weathering

LABORATORY 3 SOIL ANALYSIS

SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN

SUPER FRESHNESS METER KV-202. Instruction Manual

Recrystallization with a Single Solvent

The students will be able to: define porosity and relate it to the capacity of a common object's TEKS ADDRESSED:

Table 163 Instrument-specific information. Instrument Pour-thru Kit Cell orientation Adapter. DR 6000 LQV Arrow faces right

Dangerous for the environment

Tissue Total DNA Purification Kit (Unlabel)

Analysis of Calcium Carbonate Tablets

REAGENT SAFETY DATA SHEET

A natural impurity in water. The test will measure the amount of free oxygen "gas" dissolved in your water sample in ppm (mg/l).

OPERATING INSTRUCTIONS

OPERATIONAL MEMO GEN-14 Revision 3. November, Volatile Organic Compound (VOC) Sediment Sampling Method 5035 Field Sampling Procedure

Materials. Materials. NOTE Delta Education Customer Service can be reached at

Prolyl 4-Hydroxylated Human α- Fibrinogen ELISA

DNA Strands Revealed

MATERIAL SAFETY DATA SHEET

Significance of Water Observation Lab

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised November 2015

Experiment: Measurements

PHYSICAL CHANGE OR CHEMICAL CHANGE?

CARACTÉRISTIQUES AVANTAGES. TEST DU FER en attente de brevet

AQUATERR I N S T R U M E N T S. M, T & EC -300 User s Manual

Cartridge Prep Manual

Write your own lab Spectrophotometry/Colorimetry

Managing Hazardous Chemical Waste

Evaluate long- range plans concerning resource use and by- product disposal for environmental, economic, and political impact

QualiTube Kit For Microcystin

REAGENT SAFETY DATA SHEET

An Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+

Contact Information: Laboratory Supervisor: Denise Kind Laboratory Manager: Mat Ashby

SAMPLE LITERATURE Please refer to included weblink for correct version.

Contact: To sterilize or decontaminate uniformly, superheated steam must contact all areas of the load.

InfraCal 2 Analyzer. User s Guide. Model ATR-SP. WilksIR.com

Standard Operating Procedures. Strong Corrosives Strong Acids (SA) Acutely Toxic Chemicals Hydrofluoric Acid

Direct ISE Method Method to 10.0 mg/l F Fluoride ISE

IDENTIFYING UNKNOWN SUBSTANCES

Best Practices for Collecting Soil Samples for VOC Analysis

Bulk Density Protocol

Isolation & Characterization of Bacteria

Human beta-ngf ELISA Kit. User Manual

Standard Operating Procedure (SOP)

Use of Semi-Quantitative Field Screening Data in Hydrocarbon Investigation and Remediation

Saliva DNA Collection, Preservation and Isolation Kit 50 Individual Devices

Biotechnology In Your Mouth

DR/4000 PROCEDURE. IRON, Ferrous. Using Powder Pillows

UltraClean Mega Soil DNA Kit Catalog number: Preps (For up to 10 grams of soil)

The following list contains the Material Safety Data Sheets you requested. Please scoll down to view the requested

CHEMICAL KIT - SOLIDS

EPK- EasyTest Patch Test Kit Manual

Standard Operating Procedures. Regulated Carcinogens (RC) Formaldehyde

QuickTox Kit for Fumonisin

Microbiological Methods

Metal Finishing Products and Service META-MATE ZINCATE 40 "A CONCENTRATED LIQUID ZINCATE FORMULATION FOR THE PRETREATMENT OF ALUMINUM AND ITS ALLOYS"

Transcription:

INSTRUCTIONS & CALIBRATION PHOTOBOOK Copyright, Hanby Environmental, LLC 2012

Table Of Contents Included in your Kit / A Note on Soil Sampling..Page 4 Kit Instruc ons... Pages 5-7 Calibra on Photos Standards...... Pages 8-18 Copyright, Hanby Environmental, LLC 2012 3

Included in your Soil Test Kit: 15 Ampoules Extraction Reagent 15 Vials of Color Development Reagent 15 Screw Top Test Tubes w/ Scribed Measurement 6 Screw Top Test Tubes 1 Wooden Test Tube Rack 1 Soil Color Calibration Photobook (located behind top foam of Kit) 6 Beakers 1 Electronic Balance 1 Waste Bottle & Box (located behind top foam of Kit) 1 Graduated Cylinder 3 Pairs of Safety Gloves 1 Pair of Safety Glasses 1 MSDS Safety Instruction(located behind top foam of Kit) 1 Soil Kit Instruction 1 Instructional Video 1 Case with Foam Inserts 15 Ampoules Extraction Reagent 15 Vials of Color Development Reagent 15 Screw Top Test Tubes w/ Scribe d Measurement 1 Waste Bottle 3 Pairs of Safety Gloves A Note about Soil Sampling Soils are heterogeneous. That is, they are composed of different substances that vary widely in composition, density and absorptive properties. To simplify matters, we will describe only three soil types: sand, sandy loam and clay. Typically, you will be using Hanby Soil Kit to rapidly check several samples to determine their contamination level. Here are a few guide lines from users of our kits for over 23 years that can assist you in using the kit to best accomplished your field tasks. 1. In general, a looser (less dense) soil, such as sand or sandy loam; will absorb more liquid (petroleum or water) than compact clay. 2. Humic soils are usually very absorbent. These soils are typically dark and loose. Typically you should select these materials in a sample when you are trying to determine worst case (highest concentration of TPH) in your sample. Conversely, clays, which are typically light colored, compact and gummy show low TPH. 3. Visually Inspect several samples before you take time to analyze them with the kit. 4. Remember that in most cases you want to screen a site for the highest level of contaminant present. Following these guidelines will help in sure that your field tested samples will not be false negatives in comparison to the follow up samples you send to a lab for confirmations. Copyright, Hanby Environmental, LLC 2012 4

For Accurate Field Analysis. Hanby COLORIMETRIC Field Test Kit for TPH SOIL KIT INSTRUCTIONS Copyright, Hanby Environmental, LLC 2012 5

Six easy steps to Screening TPH s in Soil Rapid, sensitive, positive detection of petroleum in solid samples Hanby Method publica ons of the.s. EPA: Field Methods: Dependable Data When You Need It, Sept., 90 Subsurface Characteriza on and Monitoring Techniques, May, 93; S.I.T.E. Evalua on ogram, Dec 96; Expedited Site Assessment Tools for Underground Storage Tank Sites, March 97 Colorado Oil and Gas Commission, Soil Analysis Report Form #24, Rev. 3/03 Copyright, Hanby Environmental, LLC 2012 6

Hanby Soil Test Kit Instructions CAUTION: Wear safety glasses and gloves, avoid fumes Keep work area clean and well ventilated. Safety First! Introduction The accurate determination of petroleum substances in soils requires that analysis be performed as rapidly and efficiently as possible. Hanby Kits are designed to meet this important objective. Please familiarize yourself with this Field Test Kit and its procedures. Watch the video instructions, observe all cautions concerning the chemical reagents and set up your kit on a stable surface in a open ventilated area. 1. 2. 3. 4. 5. 6. 7. 8. 9. Soil Procedure Place one of the beakers on the balance and turn it on. It automatically zeros Add 5 grams of soil sample to the beaker with your spatula spoon. Remove one of the soil extraction ampoules from the foam block, hold it firmly on a flat surface and snap off the top. Avoid the sharp glass edges! Empty the ampoule into the beaker. Avoid solvent fumes! Chop the sample with the spatula and stir it in the solvent for one minute. If the soil is a clay it will be necessary to smear the soil under the solvent to insure extraction. Remove one of the test tubes from the foam. Carefully pour the solvent from the beaker into the test tube up to the marked line. Take one of the Color Development Vials out of the jar, remove the cap, and carefully empty all the white powder into the test tube. Avoid contact with the powder on skin, eyes and water! Firmly screw the cap on the test tube and vigorously shake the tube for 15 seconds. Over the next 2 minutes, periodically shake the tube for 5 seconds. Compare the color of the solid material in the bottom with the appropriate calibration photograph in your photobook. As soon as you have finished the test, record your results. Important! Empty the liquid from the test tube into the waste bottle, DO NOT POUR THE COLORED MATERIAL INTO THE BOTTLE. This remains in the bottom of the test tube. Put the used test tube back in the foam block foam for later disposal according to MSDS instructions. Do not leave solvent in used test tube. CAREFUL! The waste bottle builds up fumes hold it away from eyes and breathing zone when opening it! PLEASE DISPOSE OF WASTE PROPERTY ACCORDING TO MSDS INSTRUCTIONS. HANBY CAN NO LONGER ACCEPT WASTE BOTTLES Copyright, Hanby Environmental, LLC 2012 7

For Accurate Field Analysis. SOIL Calibra on Photobook Copyright, Hanby Environmental, LLC 2012 8

GASOLINE in Soil mg/kg GASOLINE in Soil mg/kg Copyright, Hanby Environmental, LLC 2012 9

Copyright, Hanby Environmental, LLC 2012 10

Copyright, Hanby Environmental, LLC 2012 11

Copyright, Hanby Environmental, LLC 2012 12

Copyright, Hanby Environmental, LLC 2012 13

Copyright, Hanby Environmental, LLC 2012 14

Copyright, Hanby Environmental, LLC 2012 15

Copyright, Hanby Environmental, LLC 2012 16

DDT-DD IN SOIL mg/kg Copyright, Hanby Environmental, LLC 2012 17

BLK 50 200 400 500 800 1000 Lubricating oil in Soil (mg/kg) BLK 100 500 1000 5000 10000 20000 Benzene in Soil, mg/kg (PPM) 18

1772 W Sam Houston Pkwy N Houston Tx 77043 877.806.0901 Toll Free 713.468.3897 fax Copyright, Hanby Environmental, LLC 2012 19