The Root Cause of Varnish Formation Buddy Atherton, Technical Sales Manager, United Air Specialists, Inc. / Kleentek

Similar documents
Technical White Paper

Oil Degradation [Varnish]

MEASURING AND TREATING VARNISH FORMATION IN TURBINE OILS

Introduction. Adverse Affects

OIL PURIFICATION SYSTEM

Filtration of Industrial Lubes:

ADDITIVE DEPLETION: IMPACT ON USEABLE OIL LIFE AND EQUIPMENT WEAR

ESP Electrophysical Separation Process

Air, moisture, heat and particulates are among the enemies threatening the performance and life of your machinery.

Electrostatic Discharge in Hydraulic and Lubrication Systems

Phosphate Ester Fluid Testing, Maintenance Challenges, and Solutions in EHC Systems

Vacuum Dehydration Oil Purification System (VDOPS)

TRIPLE R BYPASS OIL CLEANERS

Reducing risks and raising performance: Removing dispersed and dissolved water from lubricants

EHC Fluid Recovery Case Studies using ICB, TMR, & ECR

Lubricant Varnishing and Mitigation Strategies

Simple Solutions for Removing Moisture, even with Strong Emulsions, from Oils up to ISO VG 1000

WATER & PARTICULATE CONTAMINATION IN OIL & LUBRICATED SYSTEMS

Why Fine Filtering for quench oil systems is a must!

The World s Most Versatile Filter System

Filtration of Oil and Related Benefits

Fluid Contamination Under Control...

Filtration of modern zinc-free and ashless hydraulic and lubrication oils

Gas Turbine Lubrication: Filter Plugging & Valve Sticking (Cause & Effect, and Prevention)

DFE... The Evolution in Filter Element Multi-Pass Development Testing Hy-Pro s Competitive Advantage

Piedmont Chapter 14, Vibration Institute Meeting December 5, Midlands Technical College West Columbia, SC

ANSI/IEEE Standard C57.12"Standard Guide for Loading Mineral Oil Insulated Transformers"

The real reasons why. And strategies to stop problems before they start.

Water Droplet Impingement Erosion (WDIE) Water Droplet Impingement Erosion (WDIE) Solid Particle Erosion. Outline

Nonwovens in Gas Turbine Air Filtration Past, Present and Future By Steve Hiner

Condition-Monitoring of Phosphate Ester

CJC Fine Filter Technology

Catalyst properties and FCC operational variables effecting resistivity

Appendix B. Glossary of Steam Turbine Terms

Water Removal. Filter Element PASSION TO PERFORM

OFFLINE FILTRATION SERVICE

Presented by: Jeff Freitag, The Water Guy Jon Tiegs, General Manager

Risk to GSHP Closed Circuit Systems Methodology & Analysis. John Westerman

Energy Transfer in a Hydraulic System. Lecture (1) Hydraulic and Pneumatic Circuits 4th year Mech. power Engineering Dept.

Taravosh Jam Design & Engineering Co.

Prediction of the Characteristics of Transformer Oil under Different Operation Conditions

Understanding hydraulic fluid contamination

A Review of Sulfide Smelting Process Gas Handling Systems

MOISTURE The Second Most Destructive Lubricant Contaminate, and its Effects on Bearing Life

Par-Test. Fluid Analysis

Wastewater Recycling Plants with Zero Effluent Discharge. Water Recycling Plants

Fluid Conditioning All-Round Protection from the Fluid to the System

How to ensure proper oil cleanliness in lubrication systems

High Velocity Oil Flushing Contamination Control Oil & Fuel Purification Services

VOLUME 06 ISSUE 07-JULY 2013

How a high quality Turbine Oil can help reduce Downtime

NANO FILTERING SYSTEM

Understanding and Cleaning of Reverse Osmosis System Article of interest by Dewindia Team

Tribology Module4: Lubricants & Lubrication

The blackout of 14 August 2003 was

Filtration for Oil and Gas

Hydrosol System Furnace Cooling Water Cleaning Case Study: North American Stainless

PAG-based Turbine Fluid-Five Years of Varnish Free Performance

White Paper. Fire Sprinkler Riser Corrosion. (May 2014) Jeffrey Kochelek (Engineered Corrosion Solutions, LLC) V.1.0.1

Table of Contents... 1 Start Up Instructions After Installation Introduction Water Quality & Conditions Weather Considerations...

NUCLEAR TRAINING CENTRE COURSE 134 FOR ONTARIO HYDRO USE ONLY

R & R IDENTIFICATION CO.

Downsizing a Claus Sulfur Recovery Unit

Technical Paper Aluminum Wire Drawing Filtration Presented By Joseph F. Scalise, President, Filtertech, Inc. U.S.A.

Contamination Control For Wind Turbines

Excellent Insulation and Cooling of Power Transformer Oil 25#&45# Brand Transformer Oil Specification

BOILER FEED WATER AND ITS TREATMENTS

Technical Information Paper. (R)FCC Slurry Oil Filtration

Electro Discharge Machining

Valve Nest Filter with Time Clock Control Installation and Operation Manual

Water supplied by Marafiq does not meet the process requirements.

Managing Water Contamination in Hot Rolling Mills to Improve Productivity

RainMaker Humidification System for Precise Delivery of Water Vapor into Atmospheric and Vacuum Applications

1. Scaling. H.O.: H-5/21, KRISHNA NAGAR, DELHI Tel.: , Fax:

Preface to the First Edition Preface to the Second Edition. Acknowledgment

HTP. HTP070 Purifier for Dielectric Fluids. PIH HTP070b

Custom Systems Built to Exacting Client Specification

Contamination Fundamentals

Basics of Oil Condition Monitoring Through Oil Analysis Marian Kiley Key Account Manager Analysts, Inc.

G E N E R A L C AT A L O G

Advanced water purifier system operation manual and setup guide

Comparing Renewable Energy Sources

POREX Tubular Membrane Filter Modules For Metal Contaminated Wastewater Treatment & Reclamation

GLASS enamelled hot water cylinder with 1 fixed spiral coil

XL0897 HIGH-FLASH POE CHAIN OIL

Fluid Contamination Under Control with Innovative Products, Support and Solutions.

High Performance, Corrosive Handling Pleated Filters

Clean Oil. Guide. 100 micrometres Grain of salt. 40 micrometres Naked eye visibility. 70 micrometres Human hair. 3 micrometres OIL

Versatile Research Heat Exchanger

STATE OF NEW YORK EXECUTIVE DEPARTMENT - OFFICE OF GENERAL SERVICES DESIGN AND CONSTRUCTION GROUP - DIVISION OF DESIGN

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

NIRMAL. Generating Efficiency. Transforming Businesses

Revolution. NON-Chemical Treatment. Technology. for Scale Control. 500 different Applications NON TOXIC FOR POLLUTION PREVENTION AND GREEN TECHNOLOGY

Preliminary Hazard Analysis and Risk Assessment for the Wood Centre Development, Southwood Resources - Huon

CAUSTIC RECOVERY USING MEMBRANE FILTRATION

AQUAVENDOR AUTO. Ultrafiltration Unit SETUP OPERATING INSTRUCTIONS

oil cleaner Electrostatic Product brochure

ISSN: [Utama et al., 8(1): January, 2019] Impact Factor: 5.164

Fluid Trending Service

The ORBITRON 3000 Electrostatic Oil Purification System Orlando Utilities Commission BETA Test and Lab Results December 13 th, 2016

Transcription:

The Root Cause of Varnish Formation Buddy Atherton, Technical Sales Manager, United Air Specialists, Inc. / Kleentek INTRODUCTION It has long been established that thermal stressing of lubricating oil results in its oxidation. It is also known that the byproducts of oil oxidation lead to the formation of varnish in hydraulic control and lubricating oil systems. Dr. Akira Sasaki, former Managing Director, Kleentek Corporation, conducted a groundbreaking study on the root causes of varnish formation in gas turbine oil. Specifically, his study examined the hydraulic control and lubricating oil filters of a gas turbine to determine what role they played in the formation of varnish, and the reasons for spark discharges that result from static charge buildup within the system. The research included the examination of a GE Frame 9FA gas turbine that was experiencing severe varnish effects. Although the subject of review involved a gas turbine, the conclusions do have relevance to both gas and steam turbine systems, as well as hydraulic control and lubricating systems in general. GAS TURBINE APPLICATIONS THE MOST SEVERE CASE The severity of the operating environment for gas turbine oil has significantly increased through the years as turbine developments to improve efficiency and minimize capital cost have led to elevated firing temperatures (hence higher operating oil temperatures) and the use of a common oil reservoir, often combining the turbine s bearing oil with the control oil. In some cases, this single oil reservoir may also supply the sealant for compressed gases (such as hydrogen) and provide hydrostatic lift oil while the turbine is on turning gear. These severe operating conditions particularly the high cyclic nature of operation and very high temperatures cause varnish generation. Although steam turbines and other hydraulic applications may have less severe operating conditions, the formation of varnish is still a problem. TURBINE PROBLEMS CAUSED BY VARNISH Figure 1 Varnish on a bearing (left). Stuck valve due to varnish (top). Varnished pencil filter (bottom). After oxidation of the oil and the evolution of free radicals into a combined form that constitutes varnish, these sticky deposits adhere to the metal surfaces of the oil loop piping, valves, heat exchangers, strainers, filters, and other sensitive equipment. In turn, this growing film catches other fine particulates on the sticky surface, which continues to build up around the particulates, forming an abrasive, destructive surface. Research has also shown that deposits of polymerized oil oxidation products play a role in the deterioration of gaskets and mechanical seals. Other potential problems caused by varnish in turbine systems include: Restriction and sticking of moving mechanical parts, such as servo or directional valves. Increased component wear due to varnish s propensity to attract dirt and solid particle contaminants. Loss of heat transfer in heat exchangers, increased friction, heat and energy due to varnish s thermal insulation effect. 1

Auto-catalytic deterioration of the lubricant. Plugging of small oil flow orifices and oil strainers. Reduction in filter efficiency and potential filter plugging. Journal-bearing failure. Increased maintenance costs due to cleanup and discard of oil. MAIN ROOT CAUSE OF VARNISH: HEAT No matter how robust the oil additive package for oxidative and thermal stability, there is always a point where the varnish contamination level in the oil exceeds the capability of the inhibitors. Higher operating temperature or increased levels of harmful catalysts (e.g., water and wear metals), accelerate the oxidation of the oil and severely challenge the effectiveness and durability of antioxidant additive packages. It is observed that for every 10C (18F) increase in operating oil temperature, the rate of oil oxidation doubles (Arrhenius rate rule). However, oxidation of oil, and hence the formation of varnish, is not slowed as much as expected when the oil temperature is kept below 60C (140F). Reason: Other causes of intense heat, beyond the heat generated within the turbine bearings, exist within the oil circuit. One cause of hot spots in the oil is micro-dieseling the implosion of entrained air bubbles when the oil passes through a high-pressure pump in the hydraulic circuit that creates a local oil temperature in excess of 1000ºC (over 1800ºF), more than hot enough to cause oxidation of oil molecules. Another cause of hot spots is the generation of spark discharges. The power generation industry s shift to synthetic and glass filter media has created unexpected side effects due to the combination of tighter filter pore sizes to remove fine sediment with very high filter flux rates (flow rate per unit area) to reduce capital cost. The result is significant static charge buildup within the oil system. Figure 2 Spark discharge within an oil reservoir. These spontaneous discharges (lasting nano seconds) can generate sparks with temperatures greater than 10,000ºC (over 18,000ºF) which is hotter than the surface of the sun. This intense heat caused by static discharges literally cooks the oil, creating oil molecule fragments that deplete antioxidant additives. A video of the filter spark discharge test conducted by Dr. Sasaki can be found at www.kleentek.com/video.asp. Although filter manufacturers are conducting research to mitigate the static charge effect of synthetic and glass media, additional research has shown that places in the oil circuit where there is metal-on-metal contact can also generate a significant static charge that leads to spark discharges. Even gas turbines that drive peaking units having very low operating hours are still vulnerable to oil oxidation and varnish formation. Experience with gas turbines shows that the practice of rolling the turbines with the turning gear two to four hours each week minimizes rotor bowing and keeping the lube oil circulating at all times maintains high reliability and availability. But with those benefits comes the undesirable side effect of furthering lube oil oxidation and varnishing. SPARK DISCHARGE IN OIL FILTERS Dr. Sasaki looked at the voltage potential generated by oil flow through various common filter medias used in turbine oil filtration the most prevalent being a tight-pore glass media composite. 2

The electrically isolated test assembly configured to see if a charge is produced within the filter when grounded and un-grounded is shown in Figure 3. Figure 3 Filter spark discharge test assembly. The hose on the right of the small tank supplies oil to the pump (seen in the background), which then delivers oil to a filter cell assembly (inlet marked by the flow transmitter mounted on a tee at the inlet to the filter). The outlet of the filter cell is directed through a hose back to the tank, closing the oil flow circuit. The wire leading from the left side of the filter cell is connected to one side of a gap electrode assembly while a ground wire leading from the other electrode in the glass beaker heads off to the right of the assembly. The glass beaker is filled with ISO VG32 oil and the stick extending out of the small tank is a thermometer for monitoring the oil temperature. The gap between the electrodes that are immersed in the beaker of oil Figure 4 Measured oil potentials. measures 1mm. The complete assembly is mounted on a poly-tetrafluoro-ethylene base with vinyl hoses to electrically isolate the system, so any charge produced within the filter cell could be measured at the outside wall of the filter cell. The two most startling observations from this experiment (Figure 4) are that the oil filter generates a greater voltage potential when it is grounded than when electrically isolated and that the generation of these high voltages, and resultant spark discharges, can occur quite quickly and frequently. Dr. Sasaki consistently found voltage potentials exceeding 10 kilovolts and that the magnitude of the voltage potential caused by static charge buildup is directly related to the flux rate through the filter media. A high flux rate creates very high voltages resulting in more powerful and frequent spark discharges while a low flux rate yields lower voltages. In his analysis of the hydraulic and lubricating oil filters on a GE 9FA large frame gas turbine, Dr. Sasaki observed that the oil flow through these two circuits is decidedly different in two key process parameters: The oil flux rate (flow per unit filter area) through the lubricating oil filter is dramatically higher than in the hydraulic control oil filter. The oil flow through the lubricating oil filter protecting the turbine bearings is continuous while the oil flow through the hydraulic control oil filter is very infrequent (occurring only when a control device is adjusted), leading to cooler oil in the hydraulic lines. The significance of these disparate conditions is that the high flux lubricating oil filter contributes by frequent spark discharges to the creation of oxidized oil byproducts that form varnish and the hydraulic filter system provides the cooler, more sedate environment where these varnish molecules can combine and become a substantial fouling problem for the critical hydraulic control devices. 3

The results of the study clearly show that spark discharges in oil do cause oxidation of the oil and that the magnitude of this oxidation is affected by the frequency of spark discharges. Dr. Sasaki s research also involved studying oil that is subjected to varying frequencies of spark discharges followed by isolation from light at room temperature over a period of months. His findings reveal that there is an auto-catalytic process that continues the oxidation of the oil (and hence varnish formation), even when the conditions that directly cause oxidation (such as heat and oil wear) are removed. (Table 1) TABLE 1 TURBINE OIL ACID NUMBER, MG KOH/G Number of Spark Discharges 0 500 2000 3000 AN Just after Spark Discharges 0.08 0.08 0.08 0.08 AN After 6 Months 0.08 0.09 0.36 0.59 AN After 9 Months 0.08 --- 0.40 0.74 The results of this test work shows that spark discharges in oil do cause oxidation of the oil, that the magnitude of this oxidation is affected by the frequency of spark discharges, and that there is an auto-catalytic process that continues the oxidation of oil (and hence varnish formation) even when the conditions that cause oxidation (such as heat) are removed. PROCESS OF AUTO-CATALYTIC OIL OXIDATION Regardless of the cause of the start of oil oxidation (high operating temperatures or spark discharge), once sufficient oil molecules have broken down into free radicals and wear metal ions, such as iron and copper, are present, a self-perpetuating reaction that continues the degradation of oil molecules may start. The impact of this chain reaction depends on the degree to which the anti-oxidant (AO) additives have been consumed. Left unchecked, this auto-catalytic oxidation process will accelerate and ultimately overpower the AO additives. The sequence of reactions that form an auto-catalytic process is shown below. Lubricant Auto-Catalytic Oxidation Process: Metal (Iron and Copper) catalyzed chain initiation Dissolved oxygen reacts with oil molecules, creating free radicals R and HOO RH + O 2 R + HOO (1) 2RH + O 2 2R + H 2 O 2 (2) Iron ion is both oxidized in #3 and reduced in #4 for a net balance Fe3+ + ROOH Fe 2+ + ROO +H + (3) Fe2+ + ROOH Fe 3+ + RO +HO - (4) Copper ion is both reduced in #5 and oxidized in #6 for a net balance Cu2+ + ROOH Cu + + ROO +H + (5) Cu+ + ROOH Cu 2+ + RO +HO - (6) Chain propagation and branching Free radicals R of #8 reaction feeds #7 reaction R + O 2 ROO (7) ROO + RH ROOH + R (8) ROOH breaks down into two radicals ROOH RO + HO (9) The two products of reaction #9 react with oil molecules to create new free radicals R that feed reaction #7 above along with alcohols (ROH) and water RO + RH ROH + R (10) HO + RH H 2O + R (11) What then follows are: Formation of aldehydes and ketones Volatiles result Condensation reactions Higher molecular weight polymers are produced Sludge and deposit formation Insolubles and varnish formed 4

TABLE 2 EFFECTS OF METAL CATALYSTS AND WATER ON OIL OXIDATION Sample # Catalysts Water Time (h) TAN 1 Nil Nil 3500 0.17 2 Nil Exist 3500 0.90 3 Fe Nil 3500 0.65 4 Fe Exist 400 8.10 5 Cu Nil 3000 0.89 6 Cu Exist 100 11.20 Reference: Tribology Series - Practical Performance of Lubricants, Saiwai Publisher Table 2 demonstrates the relationship between the presence of metal catalysts and water versus oil oxidation as measured by the total acid number (TAN). Note that the oil samples shown in Table 1 after spark discharges and left for months in a controlled environment did not have free or emulsified water present or significant levels of wear metals (it was new oil), yet the TAN value increased for the 3000 spark discharge/9-month sample. If you combine the harmful effects shown by Dr. Sasaki that occur from spark discharges in oil filters and oil circulation systems with the addition of a continuing supply of wear metals and water, the rate of oil oxidation in lubrication and hydraulic systems can be very challenging for antioxidant additives. INEFFECTIVENESS OF CURRENT OIL ANALYSIS TESTS Most oil analysis tests (such as the Rotating Pressure Vessel Oxidation Test, RPVOT) do not reliably indicate the true varnish forming potential of an oil sample, and often cannot detect this condition unless the oil already has a high enough varnish level to be detected, thus serving only as a confirmation of the existence of formed varnish. Research has shown that the application of traditional oil test methods as an early warning for the onset of oil varnish is either ineffective or provides limited information. Tests such as Fourier Transform Infra-Red (FTIR) can detect the oil oxidation byproducts that are precursors for varnish formation as a present or not present finding, but do not quantify the condition, which would provide an expression of the degree of vulnerability. The continuing development of colorimetric methods appear to provide a relatively inexpensive means for both early detection of varnish issues and a way of quantifying the condition across time to chart the system trend. This method (for example, the Quantitative Spectrophotometric Analysis, or QSA test offered by Analysts, Inc.) provides a rating number that can be compared to a relative scale to determine the degree of vulnerability to the varnish problem and help to evaluate equipment and methods that seek to reduce varnish. PREVENTING, SOLVING & REVERSING THE VARNISH PROBLEM ELECTROSTATICALLY Conventional oil cleaning methods include strainers, centrifuges, vacuum dehydrators, and mechanical media filtration. These methods are effective in removing water and hard contaminants, along with some larger soft contaminants. But removing varnish and the byproducts of oil oxidation that lead to the formation of varnish require the removal of the insoluble sub-micron size soft oxidation products. The best method demonstrated to be effective in accomplishing this is continuous electrostatic oil cleaning, which addresses contamination well beyond conventional means. 5

Figure 5 Electrostatic collection process. Figure 6 Varnished servo valve before and after 45-days of electrostatic cleaning. Operation of an electrostatic oil cleaning system on the oil leads to a lower concentration of oxidized oil byproducts, which in turn dissolves the formed varnish on the surfaces of the oil circuit as the oil tries to reestablish the equilibrium relationship between formed varnish and its precursor, the oxidized oil byproducts. As the electrostatic oil conditioner continues to remove the oxidized oil byproducts, the natural response of the fluid system to maintain the equilibrium continues to dissolve formed varnish until it is no longer present. The mechanism by which an electrostatic oil conditioner removes naturally charged contamination, such as sub-micron sized oxidized oil by products, is shown in Figure 5. Varnish that has formed (the soft, sticky contaminate) is by its nature polar (e.g., zero net charge, but having charge distribution within the particle that creates positive and negative charged poles), but is still removed by the system by a process called di-electrophoresis. A more detailed description of this process is provided in the How It Works section at www.kleentek.com. Figure 6 shows a varnished servo valve before and after 45 days of continuous electrostatic cleaning, demonstrating that formed varnish dissolves and is removed by the system when there is continual removal of the oxidized oil byproducts. Continuous, on-line electrostatic oil cleaners offer the best means of preventing varnish from interfering with the reliable operation of your equipment. United Air Specialists, Inc./Kleentek 4440 Creek Road Cincinnati, OH 45242 513-891-0400 800-252-4647 www.kleentek.com 2007 United Air Specialists, Inc./Kleentek 7