panels P RO D U C T M A P PA N E L O V E RV I E W S U P E R PA N E L B A S I C S M O D U L A R P OW E R PA N E L B A S I C S...

Similar documents
elements P RO D U C T M A P / TA B L E O F C O N T E N T S E L E M E N T S O V E RV I E W

Concentration and Collaboration in Balance

Bid Opportunity No Page 2 of 11

SYSTEM XXI PANEL SYSTEM

Apogee Planning Guide

storage P RO D U C T M A P AU D I E N C E C R E D E N Z A S TO R A G E B A S I C S

Moveable. Demountable. Reconfigurable. Architectural Walls

Specifications WireWorks Panel System KI-62214R2 1/22/2015

overview soft seating Aegis, Teknion DNA, Vignette: Full Wool, Blanc and Peridot altos solid fascias/ sidewise casegoods Flintwood, Blonde Maple

THE PERFECT FIT. Also shown Task Seating: Wish / Storage: Priority / Side Seating: Event / Table: Scenario

panel walls UNDERSTANDING PANEL WALLS FLUSH PANEL WALL BASICS ELEVATED PANEL WALL BASICS CONVERTIBLE PANEL WALL BASICS...

XSITE T. XSITE Panel System. Table of Contents. Panel System. Xsite Kimball Panel Systems

XSITE T. XSITE Panel System. Table of Contents. Panel System. Xsite Kimball Panel Systems

MultiStations OS. Three H Furniture Systems Limited Clover Valley Rd. New Liskeard, ON Canada P0J 1P0

storage AUDIENCE CREDENZA STORAGE BASICS AUDIENCE CREDENZA CONFIGURATIONS LOCKS & KEYS CHART AUDIENCE A.V. CART BASICS...

storage AUDIENCE CREDENZA STORAGE BASICS AUDIENCE CREDENZA CONFIGURATIONS LOCKS & KEYS CHART AUDIENCE A.V. CART BASICS...

PRODUCT SPECIFICATIONS Unite System

making it possible to accommodate the individual needs of end-users without planning flexibility, Transit allows you

Technical Data Sheet Signature 842

architectural products altos/optos

Boulevard System 3 Make your place

Boulevard System 3 Make your place

docittm the next phase of Viceversa

panel walls PRODUCT MAP / TABLE OF CONTENTS UNDERSTANDING PANEL WALLS FLUSH PANEL WALL BASICS ELEVATED PANEL WALL BASICS...

storage PRODUCT MAP AUDIENCE CREDENZA STORAGE BASICS AUDIENCE CREDENZA CONFIGURATIONS LOCKS & KEYS CHART...

Application Guide PLANNING WITH MONTAGE

Architect and Engineer Specifications

WINDOW TREATMENTS Window Blinds Window Shades Roller Window Shades

MODEL: SIGHT-LINE- COMMAND CENTER CONSOLES

compile systems PROTECTING THE ENVIRONMENT FOR FUTURE GENERATIONS SUSTAINABILITY INFORMATION

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

Axel Systems Furniture

SECTION Manufactured Metal Casework FLEXIBLE LABORATORY FURNITURE SYSTEM (OPTIMA) USA VERSION

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

PrivaSEE All Glass Single Track Sliding System for Acoustical Separation

Product Guide Specification

MODEL: SLAT-WALL COMMAND CENTER CONSOLES

GlassWall. Operable Partitions

MODEL: ASCEND SIT/STAND COMMAND CENTER CONSOLES

Product Guide Specification

CLINICS. LABS. PHARMACIES. PREP AND PACK.

MODEL: ASCEND SIT/STAND COMMAND CENTER CONSOLES

docittm 1 introduction 2 rails 3 work stations 4 architectural elements / accessories 5 power delivery

Architect and Engineer Specifications

THE PHARMACEUTICAL CORPORATION ( I M) KERALA LTD, KUTTANELLUR, THRISSUR

THINK OUTSIDE THE CUBE...

ALTO OFFICE + BENCHING

MODULAR PANELS PRIVACY SCREENS

VAULT. VIntegrated Storage and Filing wall

Emerge Frame and Tile System

glasswalls > Simple Double

ALARIS CONSOLE ABOUT ALARIS CONSOLE ALARIS CONSOLE FEATURES. Product Specification Document Date Published: September 17, 2004

WARRANTY 5-year product assurance.

DESIGN AND CONSTRUCTION STANDARDS. Section 2: Standards for Specific Categories of Work. Laboratory Standards

RESPONSE CONSOLE ABOUT RESPONSE CONSOLE RESPONSE CONSOLE FEATURES. Product Specification Document Date Published: September 17, 2004

HALLOWELL FORT KNOX Modular Utility Storage and Workbench System Specifications

e v o l v e s y s t e m s

VARIOTEC - TRIMMED Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit

- Standard off-modularity control

workstationindustries.com Made in the USA

SPECIFICATION GUIDE SLIDING CLOSET DOOR PART 1 - PRODUCT

Union County Vocational - Technical Schools Scotch Plains, New Jersey

CONTENTS. INTERRA 4 Overview 8 Typicals 10 Features 22 Finishes. DASH 13 Overview 16 Features 17 Typicals 23 Finishes

light and elegant twin-beam understructure freestanding or attached desks integrated storage

DIVISION 10 SPECIALTIES

1 data PIC location (with 2 ports) typically asf for multiple staff members

Workstations & Tool Supports

STUDIO 50 OFFICE PARTITIONS

UNIVERSAL. Weight Max Panel Weight: 130kg. Parameters Panel Width: Max 1300mm Glass Thickness: 8-12mm

glasswalls > Warehouse

Communications Page 1 of 9

w w w. a i s - i n c. c o m

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

GLASS WALL SPECIFICATIONS

TrendWall. Planning Guide. December 2017

PHYSICAL FACILITIES Consultant s Handbook Division 27 COMMUNICATIONS 0000 COMMUNICATIONS

ULTRA-FRAME Landscaping System

deceuninck 2500 chamfered series

GLASSWALL SPECIFICATIONS

SECTION MEDICATION CABINET. 1.1 SUMMARY A. Section Includes: 1. Medication cabinets with self-contained refrigerator and fixtures.

NOC Vision Full Depth Consoles Product Images, Description, and Module Details

Double-sided bench with intermediate legs. // worksurface: White MFC, flat edge with Desk pad SmartLeather Black

PHYSICAL BARRIERS MACHINE GUARDS ROBOTIC WORK CELLS PERIMETER OR AREAS GUARDS PHYSICAL BARRIERS

glasswalls > Warehouse

folding wall, fixed panels and Architect: David Easton

AIS Calibrate - Freestanding Application

Collaboration Boards. Industry leading design, construction and sustainability.

ASDA Aluminium Stockists and Distributors Association

Q Line Shelving Bulk Storage Shelving Heavy Duty Reinforced Shelving

OVERHEAD SERVICE DISTRIBUTION

UDL. up to QUICK. boltless. Expo Shelving. Adaptable Boltless System

SPECIFICATION - SECTION (10650) OPERABLE PARTITIONS

EDUCATION. mtmsolution.com

SECTION OUTLET, PULL, AND JUNCTION BOXES

architectural wall portfolio

A. Basket Cable Tray: A fabricated structure consisting of wire mesh bottom and side rails.

ACOUSTI-CLEAR AUTOMATIC SERIES TECHNICAL DATA

C.R. LAURENCE CO., INC. Intelli-Track SPS. Phase One - Installation Instructions

10155 Toilet Compartments


Transcription:

P RO D U C T M A P....................................1 9 PA N E L O V E RV I E W..................................2 1 17 P OW E R PA N E L B A S I C S...............................2 2 M O D U L A R P OW E R PA N E L B A S I C S.......................2 3 S U P E R PA N E L B A S I C S...............................2 4 P R I VA C Y S C R E E N B A S I C S.............................2 5 B R I D G E B A S I C S....................................2 6 D O O R PA N E L B A S I C S................................2 7 PA N E L T B A S I C S...................................2 8 PA N E L M AT R I X O R D E R F O R M.........................2 9 PA N E L P R I C I N G B U I L D - U P W O R K S H E E T..................3 0 PA N E L P R I C I N G R E M O V E / R E P L A C E W O R K S H E E T...........3 1 P RO D U C T L I S T I N G.................................3 2 t/o/s price guide February, 17

product map P E Power Panel P M Modular Power Panel P X Super Panel Page 32 Height: 36" 81" / Width: " 60" Page 38 Height: 36" 81" / Width: " 60" Page 42 Height: 36" 81" / Width: " 60" P X Add-On Module P X L 1 5 Add-On Module - Lay-In P X D Add-On Module PE42 Page 44 Height: 6" 15" / Width: " 60" Page 45 Height: 15" / Width: " 60" Page 46 Height: 6" - 15" / Width: " - 60" P O Over Panel P D Door Panel P P S F Privacy Screen Page 48 Height: 9" " / Width: " 60" Page 49 Height: 81" / Width: 36" & 42" Page 50 Height: 51" 81" / Width: 36" & 42" T P T A Panel T Page 51 Height: 36" 66" T P Bridge Page 52 Pole & T-End Height: 51" & 66" / Partition Height: " & 45" / Width: 72" 96" t/o/s price guide February, 17

panel overview Panels are the basic building block for which all other system components are dependent to create a comprehensive environment. The following outlines the basic features of all T/O/S panels. T/O/S offers three panel types Power Panel (PE), Modular Power Panel (PM) and Super Panel (PX) A variety of optional element types are available Acoustic Elements (PAA) are the default elements for both inner and outer sides of the panels An enclosed raceway is included on all panels at to carry power and communication cables: the raceway provides a conduit that allows for installation of outlets, enabling access at worksurface height Power and communications access is provided through the access door, access cover or facemounted Pass Through Holes are punched into the frame structure to enable the passage of communication cables. Up to 60 Category 5 communication cables can be accommodated in each hole power/communication element Panel frames are constructed of welded steel with an integrated baseboard Levelers are included and have an adjustment range of 2 1/2" to allow for consistency of Panel height t/o/s price guide February, 17

power panel basics The Power Panel (PE) is an economical single-frame panel, non-segmented above 36", which supports a limited portion of the Element Program and provides both power pass-through and power access capabilities. When adding an Add-On Module (PX, PXL15. PXD) to a 36" or 42" high panel with existing wiring, a special bracket is required. Please contact your Teknion Customer Service Representative for more information Overhead storage must be hung on-module using on-module brackets on any panel or 15" add- on panel Finishes Frame and metal top trim are available in Foundation and Mica colors Flintwood top trim is available in Flintwood stains " - 60" " - 60" 6" & 15" 15" The frame can be ordered as a bare frame with all elements and trim ordered separately or as a complete panel when a panel matrix is used Is not segmented above 36" height Cannot be decreased from original height specified however, can be increased Bare frames do not include top trims *Lay-in option includes a lay-in channel at the top of the panel for routing communications cables * (Not compatible with PAG, PTS or PTN Elements) There are two knockouts in each raceway for outlets, enabling access to power at worksurface height The raceway is an enclosed area used to carry power and communications cabling Ceiling feed entry via Power Pole Without lay-in Add-On Modules (PX, PXL15, PXD) Can be applied to the top of any Panel to increase height (42" high panels require PXD) Multiple 15" add- on modules can be applied on a panel to increase height Only one 6" add-on module can used on a panel and must be at the top of each Panel. 6" add- on modules cannot be used to support overhead storage With Lay-In (PXL15 or PXD-2) includes a lay-in channel for routing communication cables Must be specified at Level 2 or higher Alternative to Add-On Modules: " & 60" With lay-in A base feed knockout is included per side of the Panel Levelers offer a 2 1/2" adjustment range Over Panel (PO) Is a custom Glass Element within a frame available in a Clear or Frosted finish Must be specified at the top level and can extend to the ceiling 15" - 45"h 36" - 81"h 36"h " - 60"w t/o/s price guide February, 17 36" height: below worksurface 42" height: partial seated 51" height: full seated 60" height: full seated and partial standing 66" height: partial standing 72" height: full standing 81" height: full standing

modular power panel basics The Modular Power Panel (PM) is a single-frame Panel, segmented above 36" which supports the full Element Program and provides both power pass-through and power access capabilities. Includes a horizontal rail at every 15" increment above 36" When adding an Add-On Module (PX, PXL15) to a 36" or 42" high panel with existing wiring, a special bracket is required. Please contact your Teknion Customer Service Representative for more information Overhead storage can be hung on- or off-module on any panel or 15" add- on module Finishes Frame and metal top trim are available in Foundation and Mica colors Flintwood top trim is available in Flintwood stains The frame can be ordered as a bare frame with all elements and trim ordered separately or as a complete panel when a panel matrix is used Is segmented above 36" height Cannot be decreased from original height specified however, can be increased Bare frames do not include top trims *Lay-in option includes a lay-in channel at the top of the panel for routing communications cables * (Not compatible with PAG, PTS or PTN Elements) Ceiling feed entry via Power Pole " - 60" Without lay-in 6" & 15" " - 60" Add-On Modules (PX, PXL15, PXD) Can be applied to the top of any Panel to increase height (42" high panels require PXD) Multiple 15" add- on modules can be applied on a panel to increase height Only one 6" add-on module can used on a panel and must be at the top of each Panel. 6" add- on modules cannot be used to support overhead storage With Lay-In (PXL15 or PXD-2) includes a lay-in channel for routing communication cables Must be specified at Level 2 or higher Alternative to Add-On Modules: With lay-in 15" There are two knockouts in each raceway for outlets " - 60" The raceway is an enclosed area at used to carry power and communications cabling, enabling access at worksurface height A base feed knockout is included per side of the Panel Over Panel (PO) Is a custom Glass Element within a frame available in a Clear or Frosted finish Must be specified at the top level and can extend to the ceiling Levelers offer a 2 1/2" adjustment range 15"h 15"h 15"h 36" - 81"h 36"h " - 60"w 36" height: below worksurface 42" height: partial seated 51" height: full seated 66" height: partial standing 81" height: full standing t/o/s price guide February, 17

super panel basics The Super Panel (PX) allows maximum panel-height flexibility. It is made up of individual 15" segments from 36" up which supports the full Element Program and provides both power pass-through and power access capabilities. Includes a horizontal rail at every 15" increment above 36" When adding an Add-On Module (PX, PXL15) to a 36" or 42" high panel with existing wiring, a special bracket is required. Please contact your Teknion Customer Service Representative for more information Overhead storage can be hung on- or off-module on any panel or 15" add-on panel Finishes Frame and metal top trim are available in Foundation and Mica colors Flintwood top trim is available in Flintwood stains " - 60" " - 60" 6" & 15" 15" The frame can be ordered as a bare frame with all elements and trim ordered separately or as a complete panel when a panel matrix is used Is segmented above 36" height Can be decreased in height down to 36" Bare frames do not include top trims *Lay-in option includes a lay-in channel at the top of the panel for routing communications cables * (Not compatible with PAG, PTS or PTN Elements) There are two knockouts in each raceway for outlets enabling access to worksurface cabling Ceiling feed entry via Power Pole Without lay-in Add-On Modules (PX, PXL15) Can be applied to the top of any Panel to increase height Multiple 15" add- on modules can be applied on a panel to increase height Only one 6" add- on module can be used on a panel and must be at the top of each Panel. 6" add- on modules cannot be used to support overhead storage With Lay-In (PXL15) includes a lay-in channel for routing communication cables Must be specified at Level 2 or higher Alternative to Add-On Modules: " - 60" With lay-in The raceway is an enclosed area at 36" high used to carry power and communications cabling A base feed knockout is included per side of the Panel Levelers offer a 2 1/2" adjustment range Over Panel (PO) Is a custom Glass Element within a frame available in a Clear or Frosted finish Must be specified at the top level and can extend to the ceiling 15"h 15"h 15"h 36" - 81"h 36"h " - 60"w t/o/s price guide February, 17 36" height: below worksurface 42" height: partial seated 51" height: full seated 66" height: partial standing 81" height: full standing

screen basics The Privacy Screen (PPSF) is a lightweight, translucent panel-mounted, sliding partition. Must be mounted on adjacent Panels of the same height The total combined width of the adjacent panels must be equal to or greater than the screen width May be same width or wider than opening to be covered Cannot mount to " wide Panels; mounting brackets interfere with panel connections The Privacy Screen is not load bearing Direction in which the door will slide can be changed in the field Comes complete with caps and mounting hardware Add-On Modules (PX) and Over Panels (PO) cannot be applied on the top of the Panel to which the Privacy Screen is mounted Overhead Cabinets cannot be mounted using off-module brackets on the same Panel as the Privacy Screen 51" 66" or 81" h Mounting Brackets for Privacy Screens are 3" deep The face of the Privacy Screen sits 3" from the face of the Panel to which it is attached 36" or 42" w Finishes Screen has a lightweight translucent finish Frame is available in Foundation and Mica Colors Caps located at the end of the frame will match the Foundation finish color selected for the frame. If Mica frame is selected, caps will be Black This diagram illustrates the location of the mounting brackets and demonstrates why the " wide panel cannot be used 32 1/2" or 38 1/2" w 1/2" or 32 1/2" w 37" or 45" w Actual Screen Size t/o/s price guide February, 17 3" 3"

bridge basics The Bridge (TP) is an on or-off module panel-attached tackable space divider that moves easily within a panel environment. The Bridge is not load bearing. Cannot support shelves, cabinets or worksurfaces Not freestanding and is not intended to provide panel support Cannot be higher than the panel spine Only dry erase markers can be used on the whiteboard Consists of three parts (frame, pole and T-end), but is ordered as one unit The pole and T-end are specified at the same height Equipped with 3" levelers Different fabric can be specified for the left and right side of the Bridge 72" - 96" & 45" for 51" high pole & t-end 45" only for 66" high pole & t-end Frame Fabric (both sides) Pole Fabric or Whiteboard (both sides) 51" or 66" ABridge Tray (TZB) can be specified separately for application to one or both sides of the Bridge The Diskette Holder (ASDH) and a limited selection of Personal Organizers (PAX) can be used when the Bridge Tray has not been applied (see Compliments catalogue) Equipped with 3" levelers T-End 72" - 96" Partition can be adjusted vertically in 15" increments Finishes The pole leveler and bridge tray are Black Bridge can be finished with a Whiteboard or Fabric Pole, Frame and T-Ends are available in Foundation and Mica colors Panel-mounting hardware is available in Foundation colors t/o/s price guide February, 17

door panel basics The Door Panel (PD) allows for door applications within the Panel environment, however does not allow for power passthrough or power access. Door Panels must be connected to Panels of the same height or higher Add-on Module (PX) or Over Panel (PO) of the same width can be stacked on the Door Panel For wheelchair accessibility, specify the 42" wide Door Panel If the Door Panel is to be attached to a Wall Adapter (PWA), Panel Hinges (PH40) must be ordered The door swing is identified as left and right according to the location of the hinges This style is not available in the U.S.A. 81" Handle Style 1 (Ball Handle with Lock) Handle Style 3 (Lever Handle No Lock) 36" or 42" Handle Style 2 (Lever Handle with Deadbolt) Handle Style 9 (No Handle) Door Door Dimensions Door Clearance (Nominal) (Frame width: side-to-side) TPD_8136 79" high x 32" wide " TPD_8142 79" high x 38" wide 37" Finishes Doors are available in Foundation Laminate, and Flintwoods finishes Frame is available in Foundation and Mica colors Top trims are available in Foundation and Mica colors and Flintwood stains If Flintwood is not specified for the top trim finish, the finish will match the finish color of the frame Handles, locks and thresholds are finished in a Brushed Chrome t/o/s price guide February, 17

panel T basics The Panel T (TPTA) adds an architectural accent to a workstation while providing a secondary support to the end of a panel. The Panel T and trim adapter are supplied at the same height Does not provide primary support for panel-mounted worksurfaces Trim adapter; color should match panel frame End Trim 36" - 66" Leveling adjustment range of 3" " Finishes Panel T is available in a selection of Foundation and Mica colors Trim adapter is available in a selection of Foundation colors Panel trim adapter should match the Panel frame not the Panel T Hardware is Black If the Panel T is shorter than the Panel to which it is applied, additional Intermediate Trim must be specified t/o/s price guide February, 17

panel matrix order form Panel orders cannot be processed if element placement is not appropriately described for a panel matrix order form. The panel matrix applies to all panels (PE, PM, PX). To specify panels, a panel matrix order form must be completed identifying placement/finish of the elements and finish for the top trim T/O/S Panels can be customized to meet client requirements. This can be done by replacing the Acoustic Element (PAA) which comes as a default on the panel, with any other in the T/O/S element offering Panel Matrix order forms may be used for all types of panels, elements or Panel Add-Ons Top Trim Upper 3 Upper 2 Upper 1 Access Door Base Element 81" 66" 51" 36" t/o/s price guide February, 17

panel pricing build-up worksheet The Build-Up Pricing Worksheet is designed to help you price an order for a panel that deviates significantly from the standard offering of a complete panel with Acoustic Elements. Total cost is not affected by the pricing method you choose. For 32" Base Top Trim Upper 3 $ Upper 2 Upper 1 Access Door or Element Base Element Frame Total For 32" Base Top Trim Upper 3 + = Upper 2 Upper 1 Base Element Frame Total + = For Standard Base Top Trim Upper 3 Upper 2 Upper 1 Access Door or Element Base Element Frame Total t/o/s price guide February, 17 + =

panel pricing remove/replace worksheet The Remove/Replace Pricing Worksheet is designed to help you price an order for a panel where there is minor deviation from the standard offering of a complete panel with Acoustic Elements. Total cost is not affected by the pricing method you choose. For 32" Base Remove Replace Remove Replace Top Trim Upper 3 Upper 2 Upper 1 Access Door or Element Base Element Frame For 32" Base Top Trim Upper 3 Complete Panel Removed Replaced - + Remove Replace Removed Replaced Total - + = Remove Replace Upper 2 Upper 1 Base Element Frame Complete Panel Removed Replaced - + Removed Replaced Total - + = For Standard Base Remove Replace Remove Replace Top Trim Upper 3 Upper 2 Upper 1 Access Door or Element Base Element Frame Complete Panel Removed Replaced - + Removed Replaced Total - + = t/o/s price guide February, 17