DINAK Camiño do Laranxo, , VIGO (SPAIN) DIFLUX POLYPOPRYLENE. TÜV Industrie Service GmbH TÜV SÜD Gruppe 0036 CPD

Similar documents
Declaration of Performance (DOP)

Declaration of Performance (DOP)

2. Type, batch or serial number or any other element allowing identification of the construction product as required under Article 11(4):

Issued in accordance with the Construction Products Directive 89/106/EEC. Oude Veerseweg 23 Middelburg - The Netherlands

EEC-DECLARATION OF CONFORMITY

DINAK NEW. GREEN Line. Range of modular steel chimneys for combined heat and power (CHP) and micro combined heat and power (micro CHPs) equipment.

Installation instructions

DECLARATIONS OF CONFORMITY AND INSTALLATION INSTRUCTIONS FOR A CORRECT INSTALLATION OF A FLEXIBLE LINERS (METALLIC LINERS)

Skoberne Flue systems

InoxSabiana 25 Flues. Stainless Steel Double Wall

Installation instructions

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

INSTRUCTION MANUAL OF INSTALLATION, SELECTION AND OPERATION OF METAL CHIMNEYS AND THEIR SYSTEM ELEMENTS

Independent certification of your products & services. 2.2 Relevant Standards 1. SCOPE


Date of update January 25, 2018 Valid until

Installation Instructions

Corium Brick Rainscreen System Specifications

HEATING SOLUTIONS LTD. Cascade Flue Systems

Exterior Wall Solutions Building Shell

ASSE International Product (Seal) Listing Program. ASSE Outdoor Enclosures for Fluid Conveying Components

Installation instruction

PRODUCT APPLICATION MANUFACTURER INTRODUCTION CERTIFICATION PROCEDURE. Date of update April 6, 2018 Valid until

iglidur J200 For Anodized Aluminium iglidur J200 Phone Fax Very long service life with hard anodized aluminium

Ø mm. SYSTEM KAN-therm. High quality for reasonable price TECHNOLOGY OF SUCCESS ISO 9001

DECLARATION OF PERFORMANCE

Air flue duct for use with ecotec boilers

Sheet Metal Protective Films

Pipe Joints. Requirements and Test Methods. VdS-Guidelines for water extinguishing systems. VdS en. VdS en : (01)

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.

INSTRUCTION MANUAL OF INSTALLATION, SELECTION AND OpERATION OF METAL CHIMNEYS AND THEIR SYSTEM ELEMENTS

Metal Roof Certification & Listing Program

Installation Instructions

P36 / P36E Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.35 kw)

PRODUCT CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE

EPV Pellet Vent Pellet Stove Venting System Installation Instructions

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Dunbrik A1 Concrete Flue Liners

PIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D

F Ü R D I E ZU K U N FT G E DAC HT. Flat roof vents. Soil vent pipes Refurbishment vents Cold roof vents

DWKL/SWKL PRODUCT LINE DWFL/SWFL PRODUCT LINE DWGV/SWGV PRODUCT LINE

BuildingName The Description of the Project P DOCUMENTS

European Technical Assessment. ETA-18/0083 of Member of. General part

iglidur A180 Very Appetising iglidur A180 Fax Phone

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.

MULTILINE FLUE KIT EVOMAX P - 80P

Metal Roof Certification & Listing Program. 4. Evaluated Roof System Description: 1. Program Licensee: 2. Certified Roof Covering: 5.

APPENDIX "B" November 5, 2002 Page 1 of 6 BOILERSMITH LTD. STACKS AND BREECHING

Midtherm Vitrelux flue pipe is available from stock, in the following standard colours and diameters, unless otherwise stated:

Appraisal No. 719 (2011) BRANZ Appraisals Marshall Innovations Limited BRANZ

EN :2003. TESTS OF INDUSTRIAL, COMMERCIAL and GARAGE DOORS and GATES. A Report To: D4 Products Ltd. Document Reference: WIL

Type II Environmental Declaration according ISO 14021:2001/A1:2011

CERTIFICATE No VTT-C Date of issue

Quality NBR Insulation

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Trapezoidal Plus KS1000 DLTR PLUS 1.3 & 0.8

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Klick KS500 DLKK

European Technical Assessment. ETA-11/0372 of Member of. General part

iglidur F The Lightning Conductor iglidur F Phone Fax Electrically conductive High compressive strength

Fire resistant toughened safety glass. Heat-reflective coating*

Revision:C Pipework Insulation Issued:14/11/2012 PIPEWORK INSULATION CU14. 14/11/2012 Page 1 of 10 Pipework Insulation - RevC

SI T T FST

ROCKWOOL Board Insulation Section Master Guide Specification Page 1 Jan 2017

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations...

SoCal Dynamic Dome Skylight SECTION UNIT SKYLIGHTS

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

SPECIFICATION For the Supply and Installation of BRITAL SG-2-56-HFF. Two Sided Structurally Glazed Curtain Walling. (Horizontal Structural joints)

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

Regency Bellerive & Berwick Zero Clearance Box and Flue Kit Part No Assembly Instructions

One off tiled/mortared stoves Calculation method

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations...

The syphonic roof drainage system

Installation Instructions

CUAP 06.02/13. Blind rivets for metal members and sheeting

Sprinkler Identification Numbers (SINs)

Assembly Instruction. FLAMRO Variant N II A / N II KS

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE

SI T T FSS/FSTT Open Fire

All pipes and fittings produced by Iplex Pipelines are manufactured using a Quality Management System accredited to ISO 9001:2000.

Earth Retaining Structures and Systems Submittal Checklist. Part One: Materials and Material Properties

ESSERGULLY. Safe conventional drainage. Gully systems for flat roofs, balconies and terraces

Arcwall. Rain Screen Wall System

mcr LAM louvered vents

iglidur A180 FDA-general purpose waterproof material

European Technical Assessment ETA-18/0449 of 2018/06/01

Characteristics of Packings for Stuffing Boxes for the Proof of Strength, Function and Tightness of Valves

CRYOGENIC SUPPORTS INTRODUCTION

SRP-AirOutshield ROOF Issued:

DANGEROUS GOODS PETRO INDUSTRIAL TANK COMPLIANCE CHECKLIST FORM

ROCKWOOL Board Insulation Section Master Guide Specification Page 1 Jan 2017

Design Criteria, CPVC Pipe

ATTENTION INSTALLING PERSONNEL

Hoesch isodach integral Technical information

Beele Engineering B.V.

ROOFING UNDERLAYS AND MEMBRANES.

Transcription:

Rev.2 DECLARATION OF CONFORMITY AND PRODUCT DESCRIPTION 14471 Chimneys - System chimneys with plastic flue liners - Requirements and test methods Manufacturer: Product commercial name: Product description: DINAK Camiño do Laranxo, 19. 36216, VIGO (SPAIN) DIFLUX POLYPOPRYLE Double wall plastic chimney Name and function of the responsible person: Notified Body: Certificate number: Íñigo A. Canoa (General Manager) TÜV Industrie Service GmbH TÜV SÜD Gruppe 0036 CPD 90220 017 Designations according to 14471: 0.1 Double wall plastic chimney (DN 160) Product description Standard number Temperature class Pressure class 14471 T120 H1 O W 2 O00 E E L0 Mechanical resistance and stability Tensile strength: 30 m. Inner roughness: 1 mm (according to 13384-1 Standard) coefficients ζ according to 13384-1 Standard Sootfire resistance Condensate resistance class Wet working conditions: Yes Corrosion resistance class Distance to combustible material Location Reaction to fire Enclosures class 1

Rev.2 DECLARATION OF CONFORMITY AND PRODUCT DESCRIPTION 14471 Chimneys - System chimneys with plastic flue liners - Requirements and test methods Manufacturer: Product commercial name: Product description: DINAK Camiño do Laranxo, 19. 36216, VIGO (SPAIN) DIFLUX POLYPOPRYLE Double wall plastic chimney Name and function of the responsible person: Notified Body: Certificate number: Íñigo A. Canoa (General Manager) TÜV Industrie Service GmbH TÜV SÜD Gruppe 0036 CPD 90220 017 Designations according to 14471: 0.1 Double wall plastic chimney (DN > 160) Product description Standard number Temperature class Pressure class 14471 T120 P1 O W 2 O00 E E L0 Mechanical resistance and stability Tensile strength: 30 m. Inner roughness: 1 mm (according to 13384-1 Standard) coefficients ζ according to 13384-1 Standard Sootfire resistance Condensate resistance class Wet working conditions: Yes Corrosion resistance class Distance to combustible material Location Reaction to fire Enclosures class 2

Rev.2 Characteristics Unit s 1 Nominal dimensions mm 5 2 Material inner wall Quality Nominal thickness (minimum thickness mm Ref. 14471 Inner: 60, 80, 100 Outer: 100, 125, 150 Polypropylene ND 60: 2,0 ND 80: 2,0 ND 100: 2,2 3 Material outer wall 6 Steel ST 1203 Values / Levels Remarks Thickness 0,8 mm 4 Thermal performance 6.2.1 According to 13216-1 5 Mechanical behaviour and stability 6 Wind load resistance 6.2.2 30 m. 6.3 7.3 Non applicable 7 Fire resistance 6.4 None 8 Gas tightness 6.5 7.5.1 9 Recycling 6.5.2 10 11 Accidental human contact Adjacent combustible materials 12 Thermal resistance 13 Tightness against moisture and condensate 14 15 16 17 18 Long-term resistance to thermal load Long-term resistance to condensate exposure Resistance to wet/dry cycling Resistance to ultraviolet radiation (UV) 19 Geometrical stability 20 Reaction to fire 6.6.1.2 7.6.1.2 6.6.1.3 7.6.1.2 6.6.2 7.6.2 Pressure level: DN 160: H1 (leakage rate <0.006 L/s/m 2 at 5000 Pa) DN > 160: P1 (leakage rate <0.006 L/s/m 2 at 200 Pa) Protection in the traffic area needed None None 6.6.3 The chimney is resistant 6.6.5 7.6.6.1 6.7.3 7.7.3 6.7.4 7.7.4 6.7.5 7.7.5 6.7.6 7.7.6 6.7.7 7.7.7 6.7.8 4.10 According to 13384-1 Long-term resistance to thermal load fulfilled Long-term resistance to condensate exposure fulfilled Resistance to wet/dry cycling fulfilled Non applicable, because the free end of the plastic flue liner is not more than 0,4 m in length exposed to UV of the sun. Fulfilled Fulfilled according to 13501-1. Class E 21 Seals and sealants 6.7.9 EPDM. Fulfilled according to 14241-1 Density g/c m3 1,10 Hardness ShA 52 Lengthening strength to 100% MPa 1,45 1639-00/07 3

Rev.2 Characteristics Unit s Ref. 14471 Tensile strength MPa 12,1 Lengthening to breakage % 489 Permanent deformation % 22 Dimensions 60, 80, 100 Values / Levels Remarks 4

Rev. 2 DECLARATION OF CONFORMITY AND PRODUCT DESCRIPTION 1856-1 Chimneys Requirements for metal chimneys. Part 1: System chimney products Manufacturer: Product commercial name: Product description: Name and function of the responsible person: Notified Body: Certificate number: DINAK Camiño do Laranxo, 19. 36216, VIGO (ESPAÑA) DIFLUX INOX Concentric double wall metal chimney for roomsealed appliances providing the flue gas outlet through the inner wall and the air supply through the outer wall Íñigo A. Canoa (General Manager) TÜV Industrie Service GmbH TÜV SÜD Gruppe 0036 CPD 90220 024 Designations according to 1856-1: 0.1 Metal chimney with seal 1.4404/316L Product description Standard number Temperature level Pressure level Condensate resistance (W: wet; D: dry) Corrosion resistance and inner wall material Sootfire resistance (G: yes; O: no) and distance to combustible materials (in mm) 1856-1 T200 P1 W V2-L50040 O(50) Compressive strength Up to 27 m. See Annex Inner roughness: 1 mm (according to 13384-1 Standard) coefficients ζ according to 13384-1 Standard Thermal resistance 0 m 2 K / W at reference temperature Mechanical resistance and stability Non vertical installation: maximum deflection 90º and maximum length of the slope 1 m. Wind load resistance: Maximum length between supports 3 m. Maximum length from the last support 1,5 m. See Annex Wet working conditions: Yes 1

Rev. 2 DECLARATION OF CONFORMITY AND PRODUCT DESCRIPTION 1856-1 Chimneys Requirements for metal chimneys. Part 1: System chimney products Manufacturer: Product commercial name: Product description: Name and function of the responsible person: Notified Body: Certificate number: DINAK Camiño do Laranxo, 19. 36216, VIGO (ESPAÑA) DIFLUX INOX Concentric double wall metal chimney for roomsealed appliances providing the flue gas outlet through the inner wall and the air supply through the outer wall Íñigo A. Canoa (General Manager) TÜV Industrie Service GmbH TÜV SÜD Gruppe 0036 CPD 90220 024 Designations according to 1856-1: 0.1 Metal chimney with seal 1.452 /444 Product description Standard number Temperature level Pressure level Condensate resistance (W: wet; D: dry) Corrosion resistance and inner wall material Sootfire resistance (G: yes; O: no) and distance to combustible materials (in mm) 1856-1 T200 P1 W V2-L99040 O(50) Compressive strength Up to 27 m. See Annex Inner roughness: 1 mm (according to 13384-1 Standard) coefficients ζ according to 13384-1 Standard Thermal resistance 0 m 2 K / W at reference temperature Mechanical resistance and stability Non vertical installation: maximum deflection 90º and maximum length of the slope 1 m. Wind load resistance: Maximum length between supports 3 m. Maximum length from the last support 1,5 m. See Annex Wet working conditions: Yes 2

Rev. 2 DECLARATION OF CONFORMITY AND PRODUCT DESCRIPTION 1856-1 Chimneys Requirements for metal chimneys. Part 1: System chimney products Manufacturer: Product commercial name: Product description: Name and function of the responsible person: Notified Body: Certificate number: DINAK Camiño do Laranxo, 19. 36216, VIGO (ESPAÑA) DIFLUX INOX Concentric double wall metal chimney for roomsealed appliances providing the flue gas outlet through the inner wall and the air supply through the outer wall Íñigo A. Canoa (General Manager) TÜV Industrie Service GmbH TÜV SÜD Gruppe 0036 CPD 90220 024 Designations according to 1856-1: 0.1 Metal chimney with seal 1.4162/S32101 Product description Standard number Temperature level Pressure level Condensate resistance (W: wet; D: dry) Corrosion resistance and inner wall material Sootfire resistance (G: yes; O: no) and distance to combustible materials (in mm) 1856-1 T200 P1 W V2-L99050 O(50) Compressive strength Up to 27 m. See Annex Inner roughness: 1 mm (according to 13384-1 Standard) coefficients ζ according to 13384-1 Standard Thermal resistance 0 m 2 K / W at reference temperature Mechanical resistance and stability Non vertical installation: maximum deflection 90º and maximum length of the slope 1 m. Wind load resistance: Maximum length between supports 3 m. Maximum length from the last support 1,5 m. See Annex Wet working conditions: Yes 3

Rev. 2 DECLARATION OF CONFORMITY AND PRODUCT DESCRIPTION 1856-1 Chimneys Requirements for metal chimneys. Part 1: System chimney products Manufacturer: Product commercial name: Product description: Name and function of the responsible person: Notified Body: Certificate number: DINAK Camiño do Laranxo, 19. 36216, VIGO (ESPAÑA) DIFLUX INOX Concentric double wall metal chimney for roomsealed appliances providing the flue gas outlet through the inner wall and the air supply through the outer wall Íñigo A. Canoa (General Manager) TÜV Industrie Service GmbH TÜV SÜD Gruppe 0036 CPD 90220 024 Designations according to 1856-1: 0.1 Metal chimney with seal 1.4301/304 Product description Standard number Temperature level 1856-1 T200 P1 W Vm- L20040 O(50) Compressive strength Up to 27 m. See Annex Inner roughness: 1 mm (according to 13384-1 Standard) coefficients ζ according to 13384-1 Standard Thermal resistance 0 m 2 K / W at reference temperature Pressure level Condensate resistance (W: wet; D: dry) Corrosion resistance and inner wall material Sootfire resistance (G: yes; O: no) and distance to combustible materials (in mm) Mechanical resistance and stability Non vertical installation: maximum deflection 90º and maximum length of the slope 1 m. Wind load resistance: Maximum length between supports 3 m. Maximum length from the last support 1,5 m. See Annex Wet working conditions: Yes 4

Rev. 2 Characteristics Unit s Ref. 1856-1 Values / Levels Remarks 1.0 Nominal dimensions mm 4, 5 80, 100, 130 See Annex 2.0 Inner/outer diameter 80/125, 100/150, 130/200 3.0 Inner diameter (minimum) 4.0 Inner wall material mm 4, 5 78,4; 98,4; 128,4 4, 5, 6.5.2 Quality 1.4404 / 316L 1.4521 / 444 Nominal thickness (minimum thickness) Description according to 1856-1 5.0 Outer wall material 1.4162 / S32101 1.4301 / 304 mm 0,4 (0,34) 0,4 (0,34) 0,5 (0,44) 0,4 (0,34) 4, 5, 6.5.2 L50040 L99040 L99050 L20040 Quality 1.4301 / 304 1.4404 / 316L Nominal thickness (minimum thickness) Description according to 1856-1 mm 0,4 (0,34) 0,4 (0,34) L20040 L50040 Quality 1.4521 / 444 1.4509 / 441 1.4075 / 430 Nominal thickness (minimum thickness) Description according to 1856-1 6.0 Insulation 7.2 None 7.0 Seals 7.2 Designation according to 14241-1 standard Density mm 0,4 (0,34) 0,4 (0,34) 0,4 (0,34) g/c 3 1.20 ± 0.1 m Hardness ShA 55-60 Lengthening strength to 100% Tensile strength N/m m 2 1.2 N/m m 2 4.5 Permanent deformation % 25 L99040 L99040 L99040 14241-1 T200 W 2 K2 I RP: IMQ- 01SG00017 Nominal dimensions 80, 100, 130 Mechanical resistance and stability 6.1 8.0 Compressive strength 6.1.1 Up to 27 m. See Annex 9.0 Tensile strength 6.1.2 Up to 23 m. See Annex 10.0 Wind load resistance 6.1.3.2 Non vertical installation 6.1.3.1 Maximum length from the last support: 1,5 m. Maximum length between supports: 3 m. See Annex 11.0 Maximum deflection 90º (horizontal installation) See Annex 5

Rev. 2 12.0 Characteristics Maximum length of the slope Unit s Ref. 1856-1 13.0 Gas tightness 6.3 Pressure level: P1 14.0 15.0 Distance to combustible materials at T200 Accidental human contact at T200 16.0 Thermal resistance 17.0 Condensate resistance 18.0 19.0 20.0 21.0 22.0 Resistance against rainwater penetration mm 6.2 50 (O50) m 2 K / W 6.4.2 6.4.3 0 6.4.4, 6.4.5 6.4.7 Mean value of roughness Coefficients of flow resistance for fittings Terminal Coefficient of flow resistance Protection against rainwater Values / Levels Remarks 1 m. See Annex Protection in the traffic area is not needed (back ventilated air gap between de inner wall and the outer wall) Designation: W (wet) 6.4.6 Not apply (not insulated) mm 6.4.7.1 1 (according to 13384-1 standard) 6.4.7.2 Values according to 13384-1 standard 6.4.7.3 Values according to 13384-1 standard 6.4.8.1 N.P.D. 23.0 Aerodynamic behavior 6.4.8.2 N.P.D. 24.0 Corrosion resistance 6.5.1 1.4404 / 316L 1.4521 / 444 1.4162 / S32101 V2 V2 V2 Vm 25.0 Freeze / thaw resistance 6.5.3 Fulfilled according to 1856-1 1.4301 / 304 1439-00/05 26.0 Dangerous substances 7.2 None 27.0 Typical installation drawing 7.2 See Annex 28.0 Assembly instructions 7.2 See Annex 29.0 Flow direction 7.2 Installation with the outer Female at the top 30.0 Storage instructions 7.2 No corrosive atmosphere 31.0 Method of application of any sealant required 7.2 None 6

Rev. 2 Outer material COMPRESSIVE STRGTH TSILE STRGTH Height Size D (m) Height (m) 1.4301 /304; 1.4404 / 316L; 1.4521 / 444; 1.4509 / 441; 1.4075 / 430 ND (mm) 80 27 23 100 22 19 130 17 14 ND (mm) Outer material NON VERTICAL INSTALLATION Maximum deflection α (º) Maximum length of the slope Size E (m) 1.4301 /304; 1.4404 / 316L; 1.4521 / 444; 1.4509 / 441; 1.4075 / 430 80 90 1 100 130 90 1 90 1 Outer material Model COMPRESSIVE STRGTH OF THE SUPPORT Height 1.4301 /304; 1.4404 / 316L; 1.4521 / 444; 1.4509 / 441; 1.4075 / 430 Wall support 080 Adjustable wall support 083 ND (mm) 80 6 6 100 5 5 130 4 4 7

Rev.0 DECLARATION OF CONFORMITY AND PRODUCT DESCRIPTION 1856-2 Chimneys Requirements for metal chimneys. Part 2: Metal liners and connecting flue pipes Manufacturer: Product commercial name: Product description: DINAK Camiño do Laranxo, 19. 36216, VIGO (ESPAÑA) DIFLUX ALUMINIUM EVB/01 Concentric metal chimney Name and function of the responsible person: Notified Body: Certificate number: Íñigo A. Canoa (General Manager) TÜV Industrie Service GmbH TÜV SÜD Gruppe 0036 CPD 90220 042 Designations according to 1856-2 standard: 0.1 Metal chimney 1856-2 T200 P1 W Vm- L13100 O Compressive strength N.P.D. Product description Standard number Temperature level Inner roughness: 1 mm (according to 13384-1 Standard) coefficients ζ according to 13384-1 Standard Pressure level Condensate resistance (W: wet; D: dry) Corrosion resistance and inner wall material Sootfire resistance (G: yes; O: no) Thermal resistance 0 m 2 K/W at reference temperature Mechanical resistance and stability Tensile strength: 0 m. Non vertical installation: maximum deflection 90º and maximum length of the slope up to 1 m. Wet working conditions: Yes 1

Rev.0 Characteristics Unit s Ref. 1856-2 1.0 Nominal dimensions mm 4, 5 60, 80 2.0 Nominal/Outer dimension 3.0 Inner wall material mm 60/100, 80/125 4, 5, 6.5.2 Values / Levels Quality Aluminium AW 6060 573-3 Nominal thickness (minimum thickness) Description according to 1856-2 4.0 Outer wall material mm 4, 5, 6.5.2 1,0 L13100 Quality Aluminium AW 6060 573-3 Nominal thickness (minimum thickness) Description according to 1856-2 mm 1,0 L13100 5.0 Insulation 7.2 None 6.0 Seals 7.2 Remarks Mechanical resistance and stability 6.1 7.0 Compressive strength 6.1.1 N.P.D. 8.0 Tensile strength 6.1.2 0 m. Non vertical installation 6.1.3.1 9.0 Maximum deflection 90º (horizontal installation) 10.0 Maximum length of the slope Up to 1 m. 11.0 Gas tightness 6.3 Pressure level: P1 12.0 Accidental human contact 13.0 Thermal resistance 14.0 Condensate resistance 15.0 16.0 17.0 18.0 19.0 Resistance against rainwater penetration m 2 K / W 6.4.2 Protection in the traffic area needed 6.4.3 0 6.4.4, 6.4.5 6.4.7 Mean value of roughness Coefficients of flow resistance for fittings Terminal Coefficient of flow resistance Protection against rainwater Designation: W (wet) 6.4.6 Not apply (not insulated) mm 6.4.7.1 1 (according to 13384-1 standard) 6.4.7.2 Values according to 13384-1 standard 6.4.7.3 Values according to 13384-1 standard 6.4.8.1 N.P.D. 20.0 Aerodynamic behavior 6.4.8.2 N.P.D. 2

Rev.0 Characteristics Unit s Ref. 1856-2 21.0 Corrosion resistance 6.5.1 Vm 22.0 Freeze / thaw resistance 6.5.3 Fulfilled according to 1856-1 Values / Levels Remarks 23.0 Dangerous substances 7.2 None 24.0 Typical installation drawing 7.2 25.0 Assembly instructions 7.2 26.0 Flow direction 7.2 Installation with the Female at the top See product brochures See product brochures 27.0 Storage instructions 7.2 No corrosive atmosphere 28.0 Method of application of any sealant required 7.2 None 3