Solar Cell Optimization: Cutting Costs and Driving Performance

Similar documents
Maxim Solar Cell Optimizers Next Generation of Performance Optimization Residential & Commercial Rooftop

LA SILLA PV PLANT INNOVATIVE BIFACIAL PV PLANT AT LA SILLA OBSERVATORY IN CHILE

MODULE LEVEL POWER MANAGEMENT DECREASES PV COSTS AND RISKS

An inverter is the heart of a solar PV installation and it plays a critical role in maximizing energy harvest.

optimization Redefined

High Performance Monitoring Install and forget? Not quite. Best practices for PV performance management tools

INCREASING PV SYSTEM PERFORMANCE WITH ACTIVE POWER MANAGEMENT

Technical Talk on HK s Largest Solar Power System at Lamma Power Station

ANALYZING THE IMPACT OF SHADING ON PHOTOVOLTAIC ARRAYS TO OPTIMIZE SYSTEM EFFECTIVENESS

A CASE STUDY OF A RESIDENTIAL PHOTOVOLTAIC SYSTEM WITH MICROINVERTERS

LECTURE 15 PHOTOVOLTAIC MATERIALS. ECE 371 Sustainable Energy Systems

2011 UC Solar Research Symposium

Solar Photovoltaic Technologies

Decentralized Commercial Systems

FREQUENTLY ASKED QUESTIONS: STANDALONE PV

Using PVSYST for Grid-Connected Systems. PV design engineers, PV installers (with experience), PV project managers and teachers.

13-PV System Design. ECEGR 452 Renewable Energy Systems

George Gross Department of Electrical and Computer Engineering University of Illinois at Urbana-Champaign

EELE408 Photovoltaics Lecture 18 Photovoltaic Arrays & Modules

Westbrook House Annual Utility Data. Table 1. Westbrook House Utility Use. 2,713 sf, 3 people

Product Portfolio 2016 v2. Trace the sun Capture the benefit

Now we come to an important power electronic device that makes the modern PV system widely usable.

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

SVM Solar Carport Nanopower SC Application - Technical Performance Review & Data Assessment

How do weather, environment and location affect solar?

Home PV System Design

5.5 KW DC PV SYSTEM Optimal Location W Solar PV Panels 60 Cell 250W PV Module

Why PV-Testing: Quality Reasons

THE NEW SPEED OF SOLAR

TEMPERATURE TESTING AND ANALYSIS OF PV MODULES PER ANSI/UL 1703 AND IEC STANDARDS

Guideline for Fire Safety. Elements of Solar. Photovoltaic Systems

Photovoltaic Systems II. EE 446/646 Fall 2013

SOLAR ENERGY CHRIS PRICE TECHNICAL SERVICES OFFICER BIMOSE TRIBAL COUNCIL

6KW Grid Interactive Photovoltaic System

Benefits in Speed and Logistics using the RL System. snapnrack.com

The Competitive Cost Position of Thin Film Module Technologies In High Temperature and Low Light Conditions

SOLAR ENERGY ASSESSMENT REPORT. For 80.5 kwp. Meteorological Data Source NASA-SSE. Date 18 October, Name of Place Uttar Pradesh.

NABCEP PV Technical Sales Job Task Analysis

Green Star Photovoltaic Modelling Guidelines

BANKABILITY OF SOLAR PROJECTS HOW TO MAKE YOUR PV PROJECT BANKABLE? HOW TO SELECT EPC CONTRATCOR? ROLE OF TECHNLOGY SELECTION

SOLAR MODULES FOR ROOFTOP SYSTEMS AND SOLAR PARKS ENGLISH

Santa Monica Fire Department SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE 2008 TABLE OF CONTENTS

Beverly Hills Fire Department SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE 2008 TABLE OF CONTENTS

Thin Film TECHNOLOGY ADVANTAGE

7 Project Description

A Distributed Maximum Power Point Control For Efficiency Enhancement Of Photovoltaic System

We ve cracked the code to harness the sun

Transition to 100% Renewable Energy in California in 25 years By Tom Rust, Custom Power Solar

DEVELOPMENT OF TRANSITIONAL METHODS

FLORIDA PHOTOVOLTAIC BUILDINGS PROGRAM

Global Top 10 Trackers for 2016 GTM Research

IEC Installation Guide for SERAPHIM Photovoltaic Module

Residential PV Rooftop in India - Motivation and Quality Assessment

We ve cracked the code to harness the sun

Course Title: Advanced PV Design (PV201) (NRG 220) 5 credits (55 hours)

Basic of Bifacial. 1-1 What is Bifacial? 1-2 Terms related to Bifacial. Design guide for Bifacial

MARBLEHEAD FIRE DEPARTMENT Standard Operating Guideline Draft for Photovoltaic/Solar Installations

Guidelines for Solar Photovoltaic Installation

Bifacial PV Tracking Designing Bifacial PV projects

PV SYSTEMS PREPARING & EDUCATING YOURSELF: - SITE, SYSTEM, ECONOMICS & EXPECTATIONS - GOVERNMENT SUPPORT PROGRAMS

ABSTRACT. Introduction

PV Module Right-Sizing for Microinverters

FLORIDA PHOTOVOLTAIC BUILDINGS PROGRAM

At a Glance. Skylite Solar and Our Partners. Estimated annual revenue of : USD 17.5 $ Billion Global Employees : 45,000+ people,

Switch Solar. Praveen Raj. [20 KWp Solar Power Plant Technical Proposal] Noble Hospital Chennai, Tamil Nadu.

Q.CELLS: NOT ALL MODULES ARE CREATED EQUAL

Moving Forward to Module- Level Power Optimization

ENHANCEMENT OF MAXIMUM POWER WITH PV ARRAYS UNDER PARTIAL SHADING CONDITIONS USING SWITCHED PV APPROACH

Performance evaluation of hybrid solar parabolic trough concentrator systems in Hong Kong

Toronto Fire Station # kw PV Installation Final Report January 2012

SolarEdge. Distributed Solar Power Harvesting Systems. Company Introduction SolarEdge

Appendix T Renewable Energy Applications on the Green Deck

Soiling Monitoring Solution & Field Test Results in MENA Regions

The role of Power Electronics in Photovoltaic Power Generation Systems

Appendix 22. Copyright 2011 Surmount Energy Solutions Pvt. Ltd. Copyright 2011 Surmount Energy Solutions Pvt. Ltd

SMA STRING INVERTER SOLUTIONS FOR COMMERCIAL PV APPLICATIONS

5. Solar Photovoltaic System

Basic technical information on solar PV

LEAST COST ANALYSIS FOR SOLAR PHOTOVOLTAIC MAINTENANCE at the WMU Miller Array

CITY OF LA MESA FIRE DEPARTMENT SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE

Basic technical information on solar PV

Inside Yingli Solar s Key Components

Inside Yingli Solar s Key Components

future-proof energy with photovoltaic systems

Does a PV Tracking System Make Sense for Co-ops?

TallSlateTM Grandee Installation Manual

Design Installation and Testing of 1.6 kwp GPV System

More energy. For your business. Make the right choice with SunPower.

AN EFFECTIVE STUDY ON PERFORMANCE ANALYSIS OF GRID CONNECTED PV SYSTEM

Roll to Roll Flexible Microgroove Based Photovoltaics. John Topping Chief Scientist Big Solar Limited

HAVE THEM ALL WITH Q.ANTUM

Solar Energy Solutions

Importance of balance of system in a solar PV application

CIS. Copper Indium Selenium

CIS. CIS offers three key advantages for the homeowner, the business manager and the power plant operator:

PID Analysis MEUBELEN VERHAEGEN BETEKOM, BELGIUM

YINGLI SOLAR TWINMAX MODULES Installation and User Manual

Partial project funding by customers of Xcel Energy through a grant from the Renewable Development Fund.

A New Type of Hybrid Groundwater Energy System

Building Applied and Back Insulated Photovoltaic Modules: Thermal Models. Jaewon Oh

Transcription:

Solar Cell Optimization: Cutting Costs and Driving Performance 1

Executive Summary Over the past several years, DC optimizers have become an important technological ingredient in many residential, commercial and utility-scale solar designs. By utilizing modules integrated with this technology, system designers can reduce the power loss from shade obstructions, thus safeguarding systems against long-term module mismatch caused by uneven soiling or debris. Many PV module OEMs are now incorporating the next generation of DC performance optimization: a highly-integrated power regulator included on each cell-string within the solar module. This new solution brings more production upside while also addressing the limitations of first-generation solutions. In this white paper, we ll discuss the benefits of Maxim solar cell optimizer solutions and how modules with this technology enable increased energy harvest, expanded system size, extended reliability, and a simple, low-cost installation. 1

Solar Cell Optimization: Cutting Costs and Driving Performance Over the past several years, DC optimizers have become an important technological ingredient in many residential and commercial solar system designs. By adding these devices to each module, system designers can reduce the power loss from shade obstructions, thus safeguarding systems against long-term module mismatch from uneven soiling or debris. A growing number of module manufacturers have begun to include first-generation DC optimizers from various system integration manufacturers. But even while Greentech Media (GTM) forecasts that global shipments of modules with DC optimizers will grow from 1.3GW in 2015 to 3GW by 2017, broader adoption of these devices will continue to be limited by cost and installation complexity. Forward-thinking PV module OEMs are now incorporating the next generation of DC performance optimization: a highly-integrated power regulator included on each cell-string within the solar module. This new solution brings more production upside while also addressing the limitations of first-generation solutions. Widespread adoption of this technology is expected in geographies and solar market segments that have never before considered DC optimizers. By designing it into a solar project, developers can: Enjoy additional performance gains by building MPPT into the cells, rather than outside the module. Address obstruction scenarios that module-level products can t improve, such as cross-bank shading or even soiling patterns. Eliminate hot-spot conditions associated with diode operation, improving long-term module reliability. Continue to deploy conventional installation processes, but without the increased labor needed to install optimizer boxes, additional wiring, communication devices, Internet connections, or proprietary inverters. Benefit from performance optimization, but with a substantially lower incremental cost than firstgeneration solutions. About the Maxim Solar Cell Optimizer Conventional solar systems are limited in performance by the series connectivity of modules: forcing the string current to equal that of the least illuminated or weakest cells. Maxim solar cell optimizer works by boosting the current of the weak cells to match those of the stronger, eliminating the corresponding performance penalty of the conventional system. The solar cell optimizer s MPPT function works alongside the inverter MPPT, to ensure that the system output is optimal under any environmental conditions. The module includes three Maxim solar cell optimizers, which replace the three diodes found in a conventional module junction box. Benefits and Competitiveness Over the past 20 years, many researchers, engineers and scientists have developed a variety of electronic solutions to improve the efficiency of solar module energy output. Many existing products, such as microinverters, DC optimizers, smart modules, and string-level performance monitoring systems, are available for those bankers, investors or home users who are looking for a better return on their investments. 2

Up until now, however, there are no electronic solutions that effectively improves solar modules from within. A module-level optimizer prevents underperforming modules from harming overall system performance, but does little to minimize energy loss caused by shading, soiling, or hot spots within the module. To address this issue, major PV module OEMs are now integrating Maxim solar cell optimizers into their solar modules, bringing MPPT to every cell string within each module. Modules with solar cell optimizers provide the following benefits not available from other types of PV modules: Increased energy harvest Reduced power degradation Expanded system size Flexibility in design Minimize soiling losses CONVENTIONAL OR MODULE MODULES SOLAR CELL MODULES SOLAR CELL PANEL SOLAR CELL SOLAR CELL 85W + 85W -5W = 165W 85W + 85W +40W = 210W Figure 1: Performance of conventional module vs. solar cell optimizer module, when a single cell is shaded. 3

High-reliability solution Simple, low cost installation, with conventional system architecture Increased Energy Harvest In a conventional solar module, three bypass diodes combine to serve as a protection mechanism, allowing the module to produce power even when one of its cell strings is shaded or damaged. When the bypass diode is active, the energy production of the entire cell string is lost, even when only a small portion is shaded. The active diode now carries current, which creates heat and stress that can lead to premature failure. Such a failure results in a permanent loss of cell-string output, and potentially presents a safety issue, as the underperforming cellstring is now forced to operate in a dangerous, reverse bias condition. In the new Maxim design, however, bypass diodes are replaced with smart integrated circuits (ICs). When one cell is shaded, the smart IC chip will increase the current output from the cell-string to match that of neighboring, unshaded cell-strings. The shaded cell-string will continue to contribute all available energy, without affecting the production of unshaded strings. (In the case of a conventional solar module or module-level optimizer, one shaded cell would likely cause the entire cell-string to go offline.) Reduced Power Degradation In a conventional PV system, since solar modules are connected in series to form strings, the same current must flow through all the modules. But due to shading caused by moving clouds, leaves from trees, soiling, or module power tolerance, each module needs to work at a different current to achieve its maximum power point (MPP). Due to the series connection, the worstperforming modules wind up determining the string current, which in turn means that the other modules will deliver less power than they are capable of producing. In a Maxim system, on the other hand, solar cell optimizers find the best working point for each of the cell-strings and modules, increasing the current of weaker cell-strings to match that of the strongest one. MPP tracking (MPPT) is performed for each individual cell-string, minimizing any energy loss due to cell mismatch. During the long-term operation of a PV power plant, the solar modules suffer aging, cell microcracks, potential induced degradation (PID) and so on, which will cause power loss. A module-level optimizer can prevent an underperforming module from harming overall system performance, but cannot reduce loss caused by degradation within one panel. Integrating solar cell optimizers into a module, by contrast, permits a redesign that brings MPPT to every cell string within the module. As a result, we can optimize output at the cell-string level a far more finely-tuned solution. In a conventional or first-generation optimized module, the weakest cell in the module will determine its performance. With the Maxim module, however, mismatch within cell-strings is eliminated, so that a weak cell affects module performance much less. This module outperforms both conventional and externally optimized SOLAR CELL Figure 2. The worst-performing cell no longer determines module output. 4

Expanded System Size Well-known environmental sources of mismatch that affect PV system performance include shade, soiling, temperature gradients, and cell aging. But another common source of energy loss comes from edge-of-day, row-to-row shading, in a tilted flat roof or ground-mount design. This energy loss increases in locations further from the equator and during the winter months. A typical conventional PV system will be limited in size, to avoid object and row-to-row shading. The ground coverage ratio (GCR) is the ratio of module area to total area, and is set to minimize losses due to row-to-row shading within the system array typically to limit annual ENERGY PRODUCTION vs MODULE DENSITY energy loss to below three percent. By independently optimizing cell strings, rather than bypassing affected cell strings, the Maxim module continues to generate the maximum possible energy from shaded cell strings, enabling increased density and expanded system size. Now a designer can reconfigure a system design to allow for more inter-row shading, a unique capability that delivers 10 to 20 percent more energy density than a conventional system design. Effectively, the system can maintain the same kwh/kwp as a conventional system, but with higher ground coverage ratios. Using Maxim on a commercial rooftop project, designers can achieve mono-silicon power densities with poly-silicon costs. ANNUAL ENERGY PRODUCTION B ANNUAL ENERGY (kwh/kw) STANDARD SYSTEM INCREASE: 3-4% ENERGY A CONVENTIONAL, 30 SOLAR CELL, 30 D C HIGH DENSITY INCREASE: 15-20% ENERGY AND DESITY AC ENERGY PRODUCTION (MWh) CONVENTIONAL, 30 SOLAR CELL, 30 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 GROUND COVERAGE RATIO Figure 3. Energy output vs. module spacing shows a standard system increase of 3% to 4% energy, and a high-density increase of 10% to 20% energy and density. 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 GROUND COVERAGE RATIO Figure 4. AC energy production continues to increase for the Maxim system with tighter row spacing; the conventional system drops off with inter-row shading. 5

Several observations can be made from Figure 3. First, Point A represents a GCR that a typical system designer chooses for a conventional system. The annual kwh/kw generation is an optimal compromise to a completely unshaded GCR, to better utilize the limited roof area. The system designer has chosen a point where a three percent annual energy loss is acceptable. Second, the original system design substitutes modules with cell-level optimization at the same GCR (Point B). The project owner will benefit from three to four percent more energy, because of the modules increased shade tolerance. Third, the system designer uses the optimized modules to increase system density. This GCR is the point at which row spacing can be condensed, without sacrificing annual kwh/module production relative to the original design decision (Point C). In the free space created by the tighter row spacing, the designer can place 15 20 percent more modules, increasing the generating capacity of the project. This approach produces more electricity, while also driving overall project ROI in a favorable direction. Finally, conventional technology becomes an irrelevant choice at the high-density GCR (Point D). In this case, energy losses are too great to provide a viable option. The same shade tolerance achieved by cell-string isolation also applies to near-object shading that can render a project or specific location financially unviable. Obstacles such as trees, rooftop obstructions, parapet walls, or adjacent buildings can severely degrade the energy harvest. But by independently optimizing cell strings, designers can expand system size, or address 1000 800 MAXIM OEM MAXIM GAIN MONTHLY ENERGY COMPARISON 25% 20% ENERGY PRODUCTION (kwh) 600 400 200 15% 10% 5% ENERGY BENEFIT 0 OCT-1 DEC-1 FEB-1 APR-1 JUN-1 AUG-1 OCT-1 DEC-1 FEB-1 APR-1 JUN-1 0% Figure 5. Performance chart of a side-by-side comparison, with and without solar cell optimizers. 6

otherwise unviable rooftops, simply by placing modules closer to shade obstructions all without experiencing array-wide performance loss. Flexibility in Design By incorporating modules with solar cell optimizers, system designers can accomodate differing string lengths, multiple orientations, and different module power levels. The technology expands the string s peak power output over a wider voltage range. This greater power output allows two uneven strings to be connected in parallel, so the inverter can find an operating voltage at which both produce their peak power. This flexibility, which accommodates the site location, is not possible in a conventional system, where an inverter finds a single operating point that does not achieve peak power from either string. Minimize Soiling Losses Soiling losses are always factored into modeling exercises. In fact, in most sites with extensive solar resources, they cannot be avoided. Further, these soiling patterns are frequently common to all modules (see Figure 7), and so cannot be addressed by panellevel optimizers. TOTAL POWER (kw) 120 100 80 60 40 OPTIMIZED P-V CURVE 15 x 12 PANELS 15 x 10 PANELS COMBINED STRINGS 20 0 0 100 200 300 400 500 600 STRING VOLTAGE (V) Figure 6. Performance gained when uneven strings are connected in parallel. Figure 7. Uniform soiling pattern commonly found on large systems. 7

A module with solar cell optimizers, however, can act as an insurance policy to mitigate performance loss from dust and debris. A common example is bottom corner soiling or snow buildup. In these cases, there is no panel mismatch, so a conventional module and a module-level optimizer effectively respond in the same way. If 15 percent of the bottom row is affected, the bypass diode turns on, thereby reducing panel output by one third. Absent module-to-module mismatch, module-level optimizers provide no benefit. Only by removing the bypass diode, isolating the cell strings, and continuing to generate energy from the shaded cell string can the impact of this effect be reduced. In a rooftop study, the array with solar cell optimizers lost only 2.4 percent power, compared to an unshaded reference module. The panel-level optimized module lost 16.4 percent. A High-Reliability Solution The inclusion of the Maxim solar cell optimizer in modules from leading PV OEMs brings an unprecedented level of reliability to the system designer and project owner: 1. Proven Component Reliability of Solar Cell Optimizer In the PV industry, the PV module must meet the IEC/UL solar standards and tests, which will prove its reliability. Junction boxes/modules have passed IEC61215, IEC61730 and UL1703 test requirements. The Maxim solar cell optimizer has also passed rigorous semiconductor reliability tests, such as high-temperature operation, salt atmosphere exposure, thermal cycling, and damp heat exposure. 3000 OUTPUT POWER WITH CORNER SCROLLING 2. Low Component Count Maxim modules use the single-chip Maxim solar cell optimizer (see figure 9), resulting in higher reliability than solutions with hundreds of discrete components.. STRING POWER (W) 2500 2000 1500 1000 UNSHADED REFERENCE SOLAR CELL PANEL 500 0 6.00AM 10.00AM 2.00PM TIME OF DAY 6.00PM 10.00PM Figure 8. Performance of cell optimizer vs. module optimizer with uniform soiling pattern (as in Figure 7). Figure 9. Solar cell optimizer IC from Maxim Integrated. 8

3. Proven Integrated Circuit Fabrication Technology Maxim Integrated has shipped more than one billion DC power regulators over the past 15 years. This solar cell optimizer product is built on a long-standing reputation for quality and durability. 4. Enhanced Long-term Module Reliability Because the Maxim module does not utilize diodes to manage power production, a cell-string will not be bypassed even if fully shaded. (The diffuse light will still generate some energy.) And, because all available energy is being harvested, a shaded cell is not in reverse bias, thus eliminating the cause of hot spots and removing a common cause of long-term cell stress. Should environmental conditions still result in a cracked or otherwise degraded cell, this cell will only affect the performance of its local cell-string, without further affecting the module or array. Simple, Low-Cost Installation, With Conventional System Architecture An important element of initial PV plant cost is related to installation time. Traditional optimizer systems increase hardware, installation steps and system configuration requirements, thus raising costs substantially so in larger systems. By incorporating modules enabled with solar cell optimizers, a system designer can maximize harvest without raising installation costs. Maxim-enabled modules require no additional hardware or installation steps, and are compatible with all inverters, monitoring systems, and mounting and tracking hardware. Installation is identical to that of a conventional system, and far simpler than that of a module-level optimizer system. The module-level optimizer system must be installed on racking rails, increasing labor and materials costs with additional optimizer devices that must be installed in arrays: bolts, specific frames, DC cables, and so on. In contrast, Maxim-enabled modules do not have any more installation requirements than conventional systems. In addition, certain panel optimizers must be used with proprietary inverters, due to a lack of interbrand compatibility; others require an extensive communications system to be installed at the site before the product is functional; and both require an on-site Internet connection to complete installation and operate the systems. Fortunately, modules with Maxim solar cell optimizers can be incorporated as direct substitutions for conventional modules, and deliver outstanding system performance. And, because of the advantage of cellstring level MPPT, they improve energy production by 10-20% in high-density solar plants, compared to both conventional modules and those with modulelevel optimizers. 9

Including Maxim Enabled Modules in Your Next System Design Lifetime system performance gains, enhanced module reliability, and higher ground coverage (module density) can be attained with the simple and low-cost addition of a PV module that incorporates Maxim solar cell optimizers. One of Silicon Valley s largest analog and mixed-signal semiconductor companies, Maxim Integrated has applied over 15 years of power integration expertise to deliver this innovation. Before you start your next system design, simply ask your OEM module supplier for more information on their Maxim-enabled modules, or look for the innovative OEMs who provide these modules on the Maxim Solar Partner Page. Put the next generation of PV module innovation to work in your next PV project. Learn more For more information, visit: www.maximintegrated.com/solar 2015 Maxim Integrated Products, Inc. All rights reserved. Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc., in the United States and other jurisdictions throughout the world. All other company names may be trade names or trademarks of their respective owners. 10