DEVELOPMENT OF COMPACT VIBRATION ISOLATION EQUIPMENT APPLICABLE TO EXISTING RESIDENCES RESTORING MECHANISM UTILIZING ROLLER BEARINGS

Similar documents
COMPARISON OF SEISMIC PERFORMANCE OF BASE-ISOLATED HOUSE WITH VARIOUS DEVICES

EARTHQUAKE RESPONSE ANALYSIS OF A MID-STORY SEISMIC ISOLATED BUILDING

COMPARISON OF SEISMIC PERFORMANCE OF BASE-ISOLATED HOUSE WITH VARIOUS DEVICES

VIBRATION RESPONSE CHARACTERISTICS OF ROCKING PILLAR BASE ISOLATION SYSTEM SUITABLE FOR MASONRY HOUSES

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

Seismic Collapsing Process Analysis of One-story Thatched Roof Wooden Structure under Strong Earthquake Ground Motion

FRICTION-BASED SLIDING BETWEEN STEEL AND STEEL, STEEL AND CONCRETE, AND WOOD AND STONE

PSEUDO DYNAMIC TESTS AND IMPLEMENTATION OF SLIDING BRIDGE ISOLATORS WITH VERTICAL MOTION

SEISMIC COLLAPSING BEHAVIOUR OF ONE-STORY WOODEN STRUCTURE WITH THATCHED ROOF UNDER STRONG EARTHQUAKE GROUND MOTION

EFFICIENCY OF FURNITURE OVERTURNING PROTECTION DEVICES DURING EARTHQUAKES - A EXPERIMENTAL AND NUMERICAL STUDY -

Seismic Collapsing Analysis of Two-Story Wooden House, Kyo-machiya, against Strong Earthquake Ground Motion

STUDY ON SEISMIC PERFORMANCE OF LOW EARTHQUAKE RESISTANT MASONRY BUILDINGS RETROFITTED BY PP-BAND MESH

SEISMIC COLLAPSING BEHAVIOUR OF ONE-STORY WOODEN STRUCTURE WITH THATCHED ROOF UNDER STRONG EARTHQUAKE GROUND MOTION

Literature Review of Wood-frame Structure Tests

ADVANCED TECHNOLOGIES IN HOUSING CONSTRUCTION

A DEVELOPMENT OF A NEW TECHNOLOGY FOR BASE-ISOLATED BUILDINGS USING CROSSED LINEAR BEARINGS

Seismic damage prediction of old Japanese-style wooden house using predominant period distribution of ground surface layer

EXPRIMENTAL AND ANALYTICAL STUDY ON SEISMIC BEHAVIOR OF TRADITIONAL WOODEN FRAMES CONSIDERING HORIZONTAL DIAPHRAGM DEFORMATION AND COLUMN SLIPPAGE

A STUDY ON THE IMPROVEMENT OF SEISMIC PERFORMANCE OF THE EXISTING ARCH BRIDGE USING THE BACKUP BEARING

Development and Application of Seismic Isolation and Response Control of Buildings in Japan

Development of Cylindrical Passive Damper using High Damping Rubber

MID-STORY SEISMIC ISOLATION FOR STRENGTHENING OF A MULTI-STORY BUILDING

Floating Type Isolation System Using Earthquake Early Warning

Osamu Takahashi, Hiromasa Aida 1 Junji Suhara, Ryoichiro Matsumoto 2 Yasuo Tsuyuki 3 Takafumi Fujita 4. Kozo Keikaku Engineering 2

Shaking Table Test of Two-Story Masonry House Model Retrofitted by PP-band Mesh

FULL-SCALE VERIFICATION TEST OF DYNAMIC RESPONSE CONTOROL TECHNIQUES FOR STRONG EARTHQUAKES

Study on Improvement of Seismic Performance of Transmission Tower Using Viscous Damper

Seismic Analysis of an SPB Tank Installed in the Offshore GBS LNG Terminal

E-DEFENSE EXPERIMENTS ON FULL-SCALE WOODEN HOUSES

Seismic performance of Japanese-style two-story wooden house against the 2016 Kumamoto Earthquake

THE APPLICATION OF RESPONSE CONTROL DESIGN USING MIDDLE-STORY ISOLATION SYSTEM TO HIGH-RISE BUILDING

Development of Furniture Overturning Prevention Damper

FULL SCALE STATIC LOADING TESTS FOR TWO STORIED PLANE FRAME OF TRADITIONAL TOWN HOUSE IN KYOTO, JAPAN

Wataru Goto. NTT FACILITIES, INC. in Japan. 15th World Conference on Earthquake Engineering 24 to 28 September 2012 LISBON PORTUGAL

APPLICATION OF THE POWERFUL TMD AS A MEASURE FOR SEISMIC RETROFIT OF OLD BRIDGES

SHAKING TABLE TEST USING MULTIPURPOSE TEST BED

S T R U C T U R. Practical Solutions. magazine. Supplemental Damping and Using Tuned Sloshing Dampers. Tuned Sloshing Dampers

Experimental Study on the Outrigger Damping System for High-Rise Building

THE AMPLITUDE DEPENDENT DYNAMIC CHARACTERISTICS OF AN EXISTING BUILDING BEFORE AND AFTER SEISMIC RETROFIT

Shaking table test on seismic response behavior of 2-story masonry house model with PP-band mesh retrofitting

SMALL-SCALE STEEL FRAMES DEVELOPED FOR EARTHQUAKE ENGINEERING EDUCATION PURPOSES

1994. Seismic behavior characteristic of high damping rubber bearing through shaking table test

Collapsing Simulation of Wooden House Retrofitted by ACM Braces During Seismic Ground Motion

Effect of Seismic Reinforcement of Sheet Pile Quay Wall Using Ground Anchor

Oct. 31, :00-16:30 Session 4: Space-based technology and Affordable solutions facilitating DRR

A STUDY ON RESTORABLE PRECAST PRESTRESSED HYBRID PIERS. Akio Kasuga 1 Shigeki Unjo 2 Yoshihiko Taira 1 Hiroshi Asai 1

EXPERIMENTAL STUDY OF SEISMIC BEHAVIOR OF SCALED NON-ENGINEERED MASONRY STRUCTURES RETROFITTED BY PP-BAND MESH

DEVELOPMENT OF DESIGN MANUAL FOR SLIDING SEISMIC ISOLATION SYSTEMS FOR BRIDGES

FULL-SCALE DYNAMIC COLLAPSE TESTS OF THREE-STORY REINFORCED CONCRETE BUILDINGS ON FLEXIBLE FOUNDATION AT E-DEFENSE

Small-scale steel frames developed for earthquake engineering education purposes

A seismic reinforcement method for an existing pile foundation in soft ground and liquefiable ground

CONTROL EFFECT OF LARGE TUNED MASS DAMPER APPLIED TO EXISTING HIGH-RISE BUILDING FOR SEISMIC RETROFIT

Seismic Damage-Resistant System for Multi-Storey Modular Light Steel Framed Buildings

PERFORMANCE OF MECHANICAL SEISMIC LOAD TRANSMISSION DEVICE BASED ON IMPACT

STRESS CHARACTERISTICS OF PILE GROUP DURING EARTHQUAKE BASED ON CENTRIFUGE LARGE SHEAR BOX SHAKING TABLE TESTS

DYNAMIC TEST OF MULTIPLE TUNED MASS DAMPERS FOR VIBRATION CONTROL OF HIGH-RISE BUILDINGS

Ambient Vibration Testing of Three Unreinforced Brick Masonry Buildings in Vancouver, Canada

EARTHQUAKE OBSERVATION SYSTEM FOR TELECOMMINUCATION BUILDINGS AND EQUIPMENT IN JAPAN

Japan-US collaborative research on innovative seismic isolation solution

SEISMIC PERFORMANCE OF CONCRETE TILT-UP BUILDINGS: CURRENT WALL-TO-SLAB CONNECTIONS

Base Isolation In Seismic Structural Design

Seismic Collapsing Response Analysis of Wooden House Retrofitted by ACM Braces

Forced vibration testing of a thirteen storey concrete building

SEISMIC ISOLATION FOR STRONG, NEAR-FIELD EARTHQUAKE MOTIONS

A STUDY ON THE EFFECT OF VERTICAL GROUND ACCELERATION ON THE SEISMIC RESPONSE OF STEEL BUILDINGS

Using friction dampers for improving earthquake response of self-variable stiffness RC framed buildings

STUDY ON THE DAMAGES OF STEEL GIRDERS BY HYOGO-KEN NANBU EARTHQUAKE USING NONLINEAR SEISMIC RESPONSE ANALYSIS

An experimental study of structural plastic hinge development and nonlinear soil deformation

Shaking table test on seismic response of reduced-scale models of multi-story buildings allowed to uplift

ANALYTICAL AND EXPERIMENTAL STUDIES ON THE SEISMIC RESPONSE OF BASE ISOLATION SYSTEMS FOR ELECTRIC POWER EQUIPMENT

Seismic requirements for laminated elastomeric bearings and test protocol for verification

JOURNAL OF CIVIL ENGINEERING AND TECHNOLOGY (JCIET) INNOVATIVE ISOLATION TECHNIQUES FOR SEISMIC FORCES. Ar.Anurakti Yadav LNCT College, Bhopal

Senior Researcher, Foundation & Geotechnical Engineering Labrotory, Structures Technology Division. Director, Structures Technology Division

Seismic-Resistant Switchboards Conforming to New Regulatory Standards Concerning Commercial Nuclear Reactors

Studies on the Application of Tuned Liquid Dampers (TLD) to Up-Grade the Seismic Resistance of Structures

Effect of Groundwater Depth on Differential Settlement of Wooden Houses during Soil Liquefaction

EFFECT OF THE GRID-SHAPED STABILIZED GROUND IMPROVEMENT TO LIQUEFIABLE GROUND

FULL BASE ISOLATION FOR EARTHQUAKE PROTECTION BY HELICAL SPRINGS AND VISCODAMPERS

Response Behaviour of a Three Storied Framed Structure with Tuned Liquid Damper

OPTIMUM INSTALLATION OF VISCOUS LIQUID DAMPERS IN HIGH-RISE BUILDINGS

WEBGIS SIMULATOR FOR PROMOTION OF SEISMIC RETROFITTING AND COMMUNITY DISASTER MITIGATION ACTIVITIES

STUDY ON SEISMIC RETROFIT OF THE BRIDGE IN THE HONSHU-SHIKOKU EXPRESSWAY USING ISOLATION BEARINGS

COMPARISON OF SEISMIC RESPONSE BETWEEN BRIDGE WITH SLIDING- TYPE BASE-ISOLATION SYSTEM AND THAT WITH LAMINATED RUBBER BEARING

INNOVATIVE DESIGN AND TESTING OF A SEISMIC RETROFITTED STEEL DECK TRUSS BRIDGE

Vibration test in a Building named "Chisuikan" using Three-dimensional Seismic Isolation System

Research on seismic behavior of Wood-Concrete Hybrid Structure

GENERAL FRAME WORK OF RESARCH TOPICS UTILIZING THE 3-D FULL-SCALE EARTHQUAKE TESTING FACILITY

OPTIMUM DAMPING IN ISOLATION SYSTEM

Seismic Performance of Combined Isolation System for Asymmetric Buildings Using Non- Linear Time History Analysis

DUCTILITY OF T-SHAPE RC BEAMES STRENGTHENED BY CFRP SHEET ABSTRACT

Shaking table experimental study on the base isolation system made of polymer bearings

Seismic retrofit and shaking table test of medical equipment in a hospital

Analysis of Lateral Loads for a Framed Model with Tuned Liquid Damper

PERFORMANCE OF HIGH-RISE BUILDINGS AND SEISMICALLY ISOLATED BUILDINGS AT THE 2011 GREAT EAST JAPAN EARTHQUAKE

BEHAVIOUR OF SOIL-STRUCTURE SYSTEM WITH TUNED-MASS DAMPERS DURING NEAR-SOURCE EARTHQUAKES

GUIDELINE FOR POST-EARTHQUAKE DAMAGE EVALUATION OF RC BUILDINGS IN JAPAN

CONSTRUCTION OF A 3-D FULL-SCALE EARTHQUAKE TESTING FACILITY

HYBRID EARTHQUAKE LOADING TEST (PSEUDO-DYNAMIC TEST) OF BI- DIRECTIONAL BASE ISOLATION BEARING FOR A LARGE PEDESTRIAN BRIDGE

RESPONSE CONTROL BY DAMPER DEVICES OF HIGH-RISE BUILDING UNDER LONG-PERIOD GROUND MOTION

STABILITY OF RHOMBUS MECHANISM DAMPER SYSTEM

Transcription:

13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 24 Paper No. 387 DEVELOPMENT OF COMPACT VIBRATION ISOLATION EQUIPMENT APPLICABLE TO EXISTING RESIDENCES RESTORING MECHANISM UTILIZING ROLLER BEARINGS Takeyoshi UEMATSU 1, Yuji ISHIYAMA 2, Yasuo Aoki 3, Haruo KURAMOCHI 4, Teiji KOJIMA 5, Tetsuya SOGO 6, Hiroyuki NAKAYAMA 7, Eiji KOBAYASHI 8, Yoshikatsu NISHINO 9 and Masahiro MIYAGI 1 SUMMARY A joint research project was carried out over a period of two years (22~23) to develop a practical device to alleviate human and property losses due to earthquakes. As a result of our efforts, we succeeded in creating a device (currently patent pending) made from readily available materials that can be easily installed without heavy construction equipment or special skills. The basic performance of the device has also been verified with seismic vibration testing. INTRODUCTION In Japan, attention has focused on the inferiority of structures erected prior to revision of the building code in 198 to withstand earthquake damage. Since the major earthquake disaster in south Hyogo prefecture, there has been a pressing need for a means to provide protection particularly for standard home dwellings. As one means of improving upon the ability of buildings to withstand seismic vibrations, vibration isolation technology has an established basic theory and scores of successful examples on large scale structures. As such, several home manufacturers and general contractors have indicated plans for using the vibration isolation system for new home construction. The effectiveness of vibration isolation to not only substantially enhance seismic performance but also maintain indoor safety is widely recognized, but the high cost considerations for use in small-scale, average family homes has been one obstruction to 1 Research Officer, Hokkaido Northern Regional Building Research Institute, Asahikawa, Japan. Email:uematsu@hri.pref.hokkaido.jp 2 Professor, Graduate School of Engineering Hokkaido University. Email: yuji@eng.hokudai.ac.jp 3 Servo Technos Co., Ltd. Email: y_aoki@servo-technos.co.jp 4 DPS Bridge Works Co., Ltd. Email: h_kuramochi@dps.co.jp 5 NEC System Integration & Construction, Ltd. Email: t-kojima@nesic.com 6 Senior Research Officer, Hokkaido Northern Regional Building Research Institute, Asahikawa, Japan. Email: sogo@hri.pref.hokkaido.jp 7 DPS Bridge Works Co., Ltd. Email: h_nakayama@dps.co.jp 8 Clover System Co., Ltd. Email: LEP7557@nifty.ne.jp 9 NEC System Integration & Construction, Ltd. Email: nishino@nesic.com 1 ITOGUMI Construction Co., Ltd. Email: miyagi@itogumi.co.jp 1

popularizing its widespread use. As such, retrofit construction methods using vibration isolation technology have not been fully considered for the average residential home, so the current situation has not been conducive to promoting this technology as a viable choice for anti-earthquake strengthening of these structures. The objective of our research was to develop an inexpensive, compact mechanism to enhance the seismic performance and livability of existing residential homes, and to propose methods for its fitting and installation. The continued lull in demand for new home construction in Japan has given rise to a desire to extend the life of existing homes which makes our research all the more important, pressing and necessary. Herewith is a report on the results on the performance and effectiveness of the basic mechanism confirmed with accelerated seismic tests using large-scale / small scale shaking tables. DEVELOPMENT OF THE VIBRATION ISOLATION MECHANISM Basic development concept The basic development concept of our research is as follows: a. Give consideration to portability, keeping in mind ease of installation in existing residential homes. This would require that the mechanism be both compact and light enough to be hand-carried. b. Standard, readily available materials would be used to hold down the cost. c. Simple construction to reduce the risk of breakdown and simplify maintenance. d. To meet the varied needs of residential dwellings, separate the different assemblies for isolation, restoration, and energy absorption, thus simplifying the design for each structure. Fabrication of a prototype A prototype was fabricated based on this basic concept. An external view is shown in Photo 1. The overall characteristics are as follows: a. Moves in a horizontal direction. b. Though the movable range is +/- 2 mm, the table size is small at 3mm x 3mm. c. Thickness is less than 8mm and the weight is lightweight around 3kgf. d. Designed to withstand a load of over 5 tons. e. Several cylinder-shaped rollers are employed to provide stable isolation performance in residential homes of different weight bearing loads. f. Safety measures are included to counter upward/downward movement. g. Expansion of the spring is designed to be non-linear, which reduces the fixed cyclic reliance of the spring providing speedy restoration. Photo 1. External View of Prototype 2

PERFORMANCE OF THE PROTOTYPE VIBRATIONISORATION DEVICE Accelerated vibration tests with Large-scale shaking table Outline of test Tests to determine the basic performance of the prototype vibration isolation device were carried out using a large-scale Shaking Table with a 4m x 4m size table capable of applying simultaneous accelerated vibration in a single horizontal direction and vertically with up to a 2 ton load. First, an 8-ton, wooden frame residential test structure made from actual size materials was mounted on the shaking table (photos 2 & 3). Harmonic excitation and, accelerated vibration in an N-S direction like that of the Imperial Valley Earthquake was applied and the seismic response characteristics were measured without using the prototype vibration isolation device in place. At this stage, applying vibration with a large acceleration rate was avoided to prevent changes to the seismic response characteristics of the test structure. Next, the vibration isolation devices were inserted at the four corners of the test structure between it and the shaking table to better understand problems encountered during installation of the device(photo 4). Here, for comparison with the aforementioned prototype device, testing was also done with vibration isolation assemblies that utilize oil to reduce the input of seismic vibration to the roof area (photo 5). Seismic response characteristics were measured for both sets of devices using accelerated vibration based on input data from the Imperial Valley Earthquake (N-S direction), data from the Hyogo-ken Nambu Earthquake (Kobe Ocean Meteorological Tower; E-W and Up-Down directions; acceleration reduction to a maximum of 8%). Photo 2. NW side of Test Structure Photo 3. SE side of Test Structure Photo 4. View of Prototype Device Installed Photo 5. Oil-Type Vibration Isolation Device 3

Results of horizontally applied seismic vibration The results of the time response acceleration measured at the roof of the test structure that used an oil assembly type vibration isolation device, and the top of the Shaking Table is shown in Fig. 1, graph (a). The same measurements were also taken with the prototype device installed and these results are shown in Fig. 1, graph (b). Note that the results shown here are for tests done with data based on the Imperial Valley Earthquake (N-S direction). In this test, the maximum response acceleration using the oil assembly type vibration isolation device was reduced to 34% of the input acceleration whereas when the prototype device was used the reduction was to 14% of the input acceleration. Transference characteristics are compared in Fig. 1, graph (c). This graph also shows the transference characteristics when no vibration isolation device is used. In the shown range of 1Hz to 1Hz, vibration isolation of the input acceleration is greatest with the prototype device, which indicates its higher level of performance. 4 3 2 1-1 -2-3 -4 4 3 2 1-1 -2-3 -4 Shaking Table 1 15 2 25 3 35 4 45 (a) Current Product (Oil type) Shaking Table (b) Prototype (Roller type) Housetop Housetop 5 1 15 2 25 3 35 4 Transfer Function 8 6 4 2 Non-equipment Oil Roller bearings 1 1 Freq.[Hz] (c) Comparison of Transference Characteristics Fig. 1 Performance Comparison of Prototype and Current Oil type Product [Seismic wave: IMPERIAL VALLEY EARTHQUAKE (N-S)] Results of simultaneous horizontally & vertically applied seismic vibration Next, data from the Hyogo-ken Nambu Earthquake (Kobe Ocean Meteorological Tower; E-W direction only; acceleration reduction to a maximum of 8%) was input for the Shaking Table and the and the results of the time response acceleration measured at the roof of the test structure equipped with the prototype vibration isolation device, and the top of the Shaking Table is shown in Fig. 2, graph (a). The same measurements were also taken using simultaneous horizontally (E-W direction) & vertically applied seismic vibration and these results are shown in Fig. 2, graph (b). Note that the results shown here are for the horizontal application of seismic vibration only. Transference characteristics are compared in Fig. 2, graph (c). Erratic movement of the test structure in a relatively high frequency area is also apparent in Fig. 2, graph (c). This is contributed to excited out-of-plane vibrations of the test structure flooring. 4

Both graphs (a) and (b) in Fig. 2 show that the maximum response acceleration was reduced to about 33% of the input acceleration. This means that although the prototype device doesn t provide any vibration isolation in an up-down direction, its vibration isolation in a horizontal direction is still effective even if there is simultaneous motion in an up-down direction. 6 4 2-2 -4-6 6 4 2-2 -4-6 Shaking Table (a) Simultaneous horizontally vertically applied seismic vibration Shaking Table Housetop 1 15 2 25 3 35 4 45 Housetop 1 15 2 25 3 35 4 45 (b) Simultaneous horizontally and vertically applied seismic vibration Transfer Function 8 6 4 2 Shaked horizontally Shaked horizontally and up and down 1 1 Freq.[Hz] (c) Comparison of Transference Characteristics Fig. 2 Performance Comparison of Applied Seismic Vibration [Applied Seismic Wave: Hyogo-ken Nambu Earthquake (Kobe Ocean Meteorological Tower; E-W direction only; acceleration reduction to a maximum of 8%)] Diagonally Applied Seismic Vibration Tests with Small-scale Shaking Table Outline of test Tests to verify the isolation performance of the prototype vibration isolation device with input from a diagonal direction were carried out using a small-scale Shaking Table equipped with a 1m x 1m size table capable of applying accelerated vibration in a single horizontal direction with up to a 5kgf load. First, the prototype vibration isolation device is secured to the top of the Shaking Table so that the line from directly opposite corners of the prototype coincides with the direction of the applied seismic vibration. A weight of approximately 7kgf is placed on top of the prototype and seismic vibration is applied in a horizontal direction. Load and displacement measurements are taken. Next, the weight is replaced with a steel plate weighing approximately 75kgf and harmonic excitation is carried out. Photo 6. shows the setup for this test. Two prototype units are used for the 7kgf test and one unit is used for the 75kgf test. 5

2 Load[kgf] 1 Shaking direction Photo 6. Setup for Diagonal Application of Seismic Vibration 1 2 3 4 Disp.[mm] Fig. 3 Load/Displacement for the 7kgf Test (Using Two Prototype Units). Results of Diagonally Applied Seismic Vibration Tests Fig. 3 shows the load/displacement test results using a 7kgf weight. From the results, the movement friction coefficient is calculated to be.35. The graph in Fig. 4 shows the applied seismic vibration acceleration and the actual measurement for the response acceleration at the 75kgf test. The same graph also shows that the input acceleration is reduced to about 6 gal over all applied seismic vibration frequencies. Fig. 5 shows the applied seismic vibration displacement and the actual measurement for the response displacement at the 75kgf test. When compared to the degree of acceleration, the reduction rate tends to decline at lower frequencies, but the response displacement is less than half of the applied seismic vibration displacement and the response displacement when the frequency exceeds 1Hz does not reach 5mm though vertical load is only 75kgf. Response amplitude on shaking direction[gal] 1 9 8 7 6 5 4 3 2 1 :input :response Response amplitude on shaking direction[mm] 1 2 3 4 5 6 7.1 1 1 1 Freq.[Hz] Freq.[Hz] Fig. 4 Comparison of applied seismic vibration Fig. 5 Comparison of applied seismic acceleration and response acceleration displacement and response displacement 5 4 3 2 1 :input :response EXPANDED USES FOR THE PROTOTYPE VIBRATION ISOLATION DEVICE Basic Tests Aimed at Expanding the Use of the Vibration Isolation Device Tests for Shelving The prototype vibration isolation device was developed primarily for retrofitting of existing residential structures but is easily adapted to new home construction as well. And since it is both light and compact, it can be easily adapted to other uses where protection by vibration isolation is desired such as floors, furniture, sensitive electronic equipment, telecommunication equipment, historical artifacts, etc. making it 6

quite versatile. Here, performance of the prototype when setup under shelving was verified using a largescale Shaking Table. Photo 7. shows the overall setup for the test and Photo 8. shows the prototype device installed underneath the shelving legs. The shelving is made from steel and the total weight is approximately 3kgf. Harmonic excitation is done in a single horizontal direction and seismic vibration based on the Hyogo-ken Nambu Earthquake (Kobe Ocean Meteorological Tower; N-S direction, Up-Down direction and acceleration reduction to a maximum of 1%) added. The response acceleration of the shelving is measured at the foot of the shelving and the center of the 2 nd shelf from the top (referred hereinafter as 2 nd shelf center). The condition of the PET bottles lined up on the shelves is also confirmed. Result of the Tests to the Shelving Fig. 6 shows an example of the response acceleration of harmonic excitation applied in a single horizontal direction. No meaningful difference is noted in the response acceleration between the shelving feet and the 2 nd shelf center. The absolute displacement between the Shaking Table and the shelving this time, and the relative displacement of the shelving to the Shaking Table calculated from that result is shown in Fig. 7. Like the acceleration rate, the response amplitude is also greatly decreased Not one of the PET bottles fell down. Fig. 8 shows an example of the response acceleration for the shelving feet and the 2 nd shelf center when harmonic excitation based on the Hyogo-ken Nambu earthquake data is applied both horizontally and vertically. A high number of vibrations were recorded at the 2 nd shelf center but these are considered to be due to vertical vibrations only. Photo. 7 Overall View of Test Photo. 8 View of Device Installed at Shelving Feet 8 4-4 8 4-4 -8 (a)response Acceleration of Shaking Table/Shelving Feet (b) Response Acceleration for Shaking Table/2 nd Shelf Center Fig. 6 Example of Response Acceleration for Single Direction Harmonic Excitation -8 2 4 6 8 1 12 14 16 18 2 7

Disp.[mm] 2 1-1 Disp.[mm] 2 1-1 -2 2 4 6 8 1 12 14 16 18 2-2 (a) Absolute Displacement of Shaking Table/Shelving (b) Relative Absolute Displacement of Shaking Table/Shelving Fig. 7 Example of Response Displacement for Single Direction Harmonic Excitation 8 4-4 8 4-4 -8-8 (a) Response Displacement for Shaking Table/Shelving (b) Response Displacement for Shaking Table/2 nd Shelf Center Fig. 8 Response Acceleration for Simultaneous Horizontal/Vertical Input (Hyogo-ken Nambu earthquake) 2 2 Disp.[mm] 1-1 Disp.[mm] 1-1 -2 1 3 5 7 9 11 13 15 17 19 (a)absolute Displacement of Shaking Table/Shelving (b)relative Displacement of Shaking Table/Shelving Fig.9 Response Displacement for Simultaneous Horizontal/Vertical Input (Hyogo-ken Nambu earthquake) The absolute displacement between the Shaking Table and the shelving this time, and the relative displacement of the shelving to the Shaking Table calculated from that result is shown in Fig. 9. There are no damaging response amplitudes and not one of the PET bottles fell down. -2 8

CONCLUSION We developed an inexpensive vibration isolation device that is also both compact and lightweight for ease of installation. Shaking Tables and relative equipment were used to test and verify the performance of the device and lead us to conclude as follows: (a)even at low level harmonic excitation of 2Hz-1gal and 3.5Hz-1gal, the effectiveness of the device can be clearly confirmed with the naked eye, meaning there is very little reliance on the input level. (b)even when actual earthquake wave data is input, the acceleration rate is reduced as low as 14% of the input acceleration rate. In contrast, oil assembly (viscous) devices only reduced the acceleration rate to 34% of the input rate. (c)even with simultaneous horizontal and vertical seismic vibration applied, the device still displayed a reduction of the acceleration in the horizontal direction equivalent to that obtained when seismic vibration was applied in a horizontal direction only, proving the device safe and effective even with up-down movement. (d)even against forces inserted diagonally (45%) to the device, where there was the most concern, the passive friction coefficient was about.35 and the isolation performance was very good. It is easy to surmise that the passive and active friction coefficients are even smaller when forces are applied from other angles. (e)since there is little reliance on the load weight, in addition to buildings, the device is applicable for other equipment and things that may need protection from seismic vibration. Plans are being made for a presentation on the actual method of installation for existing residential structures. We also are planning improved developments for restoration assemblies and energy absorption assemblies End of document 9