CHOOSING THE RIGHT ONLINE FLUORIDE ANALYSER. John Day. Goulburn Valley Water

Similar documents
CHOOSING THE RIGHT ONLINE FLUORIDE ANALYSER. John Day. Goulburn Valley Water

Intelligent SUNTEX PC-3310 ph/orp Transmitter

A NEW MEMBRANE FILTRATION PLANT FOR GIRGARRE. Geoffrey Frost. Geoffrey Frost, Principal Water Engineer, Parsons Brinckerhoff Australia P/L

DAFF AIR DISPERSION REVAMP. Wes Wilkie. Goulburn Valley Water

Groundwater Monitoring on a Budget. June Mooney, Water Quality Specialist, Greater Augusta Utility District

ODW Guideline

IMPROVED MAINTENANCE OF OUR RETICULATION SYSTEMS USING INNOVATION AND DATA. Neville Whittaker. Goulburn Valley Water

OPTIMISATION OF MAGNESIUM HYDROXIDE DOSING FACILITIES. Keith McCarthy. Yarra Valley Water

LEARNINGS FROM SEVERAL HIGH CHLORINE EVENTS. Raj Mahendrarajah. Coliban Water

Complete Water Analysis Solutions for Power, Heat & Steam Generation

Boiler Water No.2 Test Kit Instruction Manual

Direct ISE Method Method to 10.0 mg/l F Fluoride ISE

A brief about online monitoring system. By Ajit Joshi & Amol Malode

Environmental Management System

Reactivity Series. Question Paper. Cambridge International Examinations. Score: /39. Percentage: /100

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Thermo Scientific Orion Dissolved Oxygen Probes

Adapted from: An original Creek Connections activity. Creek Connections, Box 10, Allegheny College, Meadville, Pennsylvania

ABB MEASUREMENT & ANALYTICS DATA SHEET. AW400 Residual chlorine monitor

Drinking Water Audit Report

On-Line Nutrient Monitoring-Operator s Job Got Easier

Hach Method Luminescence Measurement of Dissolved Oxygen (LDO ) in Water and Wastewater

TriPass ELV 1500LT Iridescent Trivalent Chromium Passivate

OPTIMISATION OF IMAGE FLAT WATER TREATMENT PLANT. Tony Humphries. Tony Humphries, Operator, SEQ Water

Utilization of Geochemical Parameters in Developing a Conceptual Site Model

WATER FLUORIDATION PLANTS IN VICTORIA. Helen Oates. Department of Health Victoria

OPERATORS PERSPECTIVE : OPTIMISATION OF A NEW PACKAGE WATER TREATMENT PLANT. Melina Entwistle. North East Water Authority

Drinking Water Audit Report

Drinking Water Audit Report

Hydrazine, sodium and dissolved oxygen measurement The power of boiler chemistry

USEPA 1 Periodate Oxidation Method 2 Method to 20.0 mg/l Mn (HR) Powder Pillows

Electrocoagulation of Drinking Water in Continuous Flow Mode for Fluoride Removal

EN14181 Stationary Source Emissions Quality Assurance of Automated Measuring Systems

Lead & Copper Water Quality Parameters

WHEN ALL THE DUCKS LINE UP: CASE STUDIES ON HITS AND VERY NEAR MISSES. Leanne Wells. Department of Health

Oxygen. Oxygen is one of the fundamental resources required by life forms on Earth. Aquatic ecosystems have a wide assortment of life forms.

DEALING WITH STRATIFICATION WITHIN A WATER SUPPLY RESERVOIR. Chris Perks. Central Highlands Water

Monitoring and Assessment of Chemical Quality. Session Objectives

March 28, 2019 Maintaining a Clean Brewery Presenter: Richard Rench Q&A Session

Online. Field Laboratory. Water Testing Product Sampler HFscientific.com. Visit our Web Site HFscientific.com. Visit Us at:

REACTION TANKS WATER PURIFICATION THROUGH SERVICE DEIONIZATION

METHANOL DOSING TRIAL FOR ENHANCED DENITRIFICATION AT LILYDALE STP. Frank Murphy. Frank Murphy,Process Engineer, Yarra Valley Water

AUTOMATED WATER ANALYSIS

EPA Primary. (mg/l as CaCO3) (mg/l as CaCO3)

Corrosion Control Across Consecutive Systems

Water Treatment Plant Year-end Report for 2014

A NEW INFORMATION SYSTEM FOR OPERATIONAL & LABORATORY DATA. Jason Whittaker. Goulburn Valley Water

THE PROBLEMS ASSOCIATED IN SETTING UP A 24HR SYSTEM MONITORING AND CUSTOMER SERVICE CENTRE. Greg Hall

Spirax Sarco Services Maintaining steam systems for peak performance.

Background Statement for SEMI Draft Document 5134 Revision to SEMI C , Specifications for Hydrofluoric Acid

OPERATIONAL CHALLENGES AT THE KOORLONG WASTEWATER TREATMENT PLANT. Derek de Waal Kevin Murphy

ENHANCING BIOGAS PRODUCTION ON AN ANAEROBIC COGENERATION PLANT. Michael Romer. Calix Limited

Enhanced calibration High quality services from your global instrumentation partner

Municipal Wastewater. Introduction: Sample Matrix: Wastewater; various locations along the sewage treatment process.

Water Quality. Water Quality Criteria for Cyanide. Overview Report. Tables. Prepared pursuant to Section 2(e) of the Environment Management Act, 1981

BENEFICIAL ODOUR CONTROL IN SEWERAGE SYSTEMS. Graeme Watkins. MidCoast Water

CHLORINE DEMAND ANALYSIS IN DISTRIBUTION NETWORKS USING HYDRAULIC MODELS AND LABORATORY TESTS. Raj Mahendrarajah. Coliban Water

Ground Water Quality Report. Inorganic Ground Water Quality Time Series

Ground Water Quality Report. Inorganic Ground Water Quality Time Series

ROYAL MELBOURNE GOLF CLUB

1-(2-Pyridylazo)-2-Naphthol PAN Method 1 Method to mg/l Mn (LR) Powder Pillows

Bushy Park Industrial Complex Bushy Park, South Carolina

THE ROLE OF A WATER TREATMENT PLANT OPERATOR IN THE SUCCESSFUL IMPLEMENTATION OF A DRINKING WATER MANAGEMENT SYSTEM. Sallyanne Bartlett

Drinking Water Audit Report

REQUEST FOR PROPOSALS DESAL ANTISCALANT/CLEAN-IN-PLACE CHEMICALS BID NO: ADDENDUM 1

INFORMATION PROCESS ANALYSIS ON-SITE ANALYSERS AMTAX SC + PHOSPHAX SC. Short paths optimal results On-site analysers for Ammonium and Phosphate

Introduction The Van London Co. Cadmium Ion Electrode is used to measure Cadmium ions in aqueous solutions.

Alkalinity: An Important Parameter in Assessing Water Chemistry

Electricide HG Electrochemical Chlorine Generators

WARNING! Read all of the information in this booklet, and any relevant Application Notes, before using the Eco Sensors DO3.

Drinking Water Audit Report

Multipoint Sampling for AMC Monitoring. Version 01. Rev 01.

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Supply of Hydrated Lime for Use in Drinking-Water Treatment

A CASE FOR CORROSIVITY MONITORING IN CANBERRA. Cameron Patrick. ACTEW Water

MECON LIMITED RANCHI , INDIA

2.0 BACKGROUND ON CALCULATED TOTAL DISSOLVED SOLIDS

GRADE 10: Chemistry 2. UNIT 10AC.2 11 hours. The chemical industry. Resources. About this unit. Previous learning. Expectations

Total Residual Chlorine Testing Methods

Mid-Loddon Groundwater Management Area Local Management Rules

Windsor Utilities Commission 3665 Wyandotte Street East Windsor, ON N9A 5T7

MECON LIMITED RANCHI , INDIA

Predictive control of ferrous chloride dosing to minimise corrosion & odour in Bellambi system. 15 June 2015

Complete Water Analysis for POWER GENERATION

Asset management begins with correct water treatment

Suggest one reason why spoons are electroplated. ... Why is hydrogen produced at the negative electrode and not sodium?

Ministry of the Environment and Climate Change. MOUNT FOREST DRINKING WATER SYSTEM Inspection Report. Inspection Number:

Year 7 Chemistry HW Questions

Comparison of Water Quality Parameters

Purification of Brackish Water using Hybrid CDI-EDI Technology

Total Dissolved Solids

PUBLIC WATER SYSTEM ANNUAL REPORT

PURE WATER ph MEASUREMENT IN LOW CONDUCTIVITY SAMPLES

Standard Operating Procedure for the Determination of Specific Conductance CCAL 11A.2

: Rodger Jeffery (Principal Author); Hardy Engineering Team; Hardy Tech Support Team

Welcome to the Whitsunday Regional Council

ANGLO AMERICAN THERMAL COAL LANDAU COLLIERY

Report AQUA METROLOGY SYSTEMS. SafeGuard H2O Pilot Report. Online Cr(VI) Remediation System

INFORMATION PROCESS ANALYSIS ON-SITE ANALYSERS AMTAX SC + PHOSPHAX SC. Short paths optimal results On-site analysers for Ammonium and Phosphate

Transcription:

CHOOSING THE RIGHT ONLINE FLUORIDE ANALYSER Paper Presented by: John Day Author: John Day, District Manager, Central Water, Goulburn Valley Water 72 nd Annual Water Industry Engineers and Operators Conference Bendigo Exhibition Centre 1 to 3 September, 2009 72nd Annual Victorian Water Industry Engineers & Operators Conference Page No. 137

CHOOSING THE RIGHT ONLINE FLUORIDE ANALYSER John Day, District Manager, Central Water, Goulburn Valley Water ABSTRACT Beginning in 2003 Goulburn Valley Water (GVW) undertook a project to select preferred online instrumentation, in an attempt to identify which analysers are the right equipment for the right application. From this project several analysers were chosen as a suitable equipment application for the online measurement of Turbidity, ph, Chlorine, EC, Streaming Current and Fluoride. In 2007 GVW concluded that there were too many choices of analyser, and a preferred list was decided on to reduce the selection to just two of each group of analyser. The following paper reviews a trial of four online analysers for the measurement of Fluoride at the Shepparton Water Treatment Plant. From the trial, two meters were to be chosen as the best fit application for the preferred list. This paper also seeks out to answer the question on the need to have Total Ionic Strength Adjustment Buffer (TISAB) as an online reagent or not. The need for such a trial was highlighted as GVW at the time were undertaking tendering for three new fluoride dosing plants, and the selection of an analyser is critical to its operation. Overarching all of this process was the release of the new code of practice for fluoridation by the Department of Human Services, Victoria. 1.0 INTRODUCTION On-line instrumentation has become one of the most valuable tools in the operators arsenal in terms of providing Safe drinking water 100% of the time. It is for this reason due to their importance that they must be accurate and reliable, they must also be supported by reliable service and calibration. The calibration needs to be simple with the least amount of steps possible and not too time consuming. The instrument should be well supported by after sales service for spare parts and advice. Above all it must meet the new DHS Code of Practice on Fluoride under section 4.5 Process Control and Instrumentation. The Code states that Dosing fluoride into drinking water is a continuous process that will involve lifetime exposure to fluoride for most consumers. It is therefore essential that the authority has in place a validated and verified system of accurately controlling fluoride dosing at all times to meet this, on-line instrumentation must be accurate and reliable. Accuracy in the code is clearly defined as The authority should carry out method and instrument validation to determine a limit of detection and resolution of their measuring instrument. Accuracy to at least +/- 0.15 mg/l should be achieved by a wellmaintained instrument in a production environment. 2.0 ANALYSER SELECTION With all of these factors in mind GVW undertook a trial to identify what instrument was the best fit to address accuracy, reliability, service, ease of calibration, parts availability, size and position, purchase and running costs. Four separate suppliers were approached for the availability of a trial unit to compare and judge for ourselves the best fit unit that meets all the criteria stated above. The following suppliers and units where chosen: Orion Pacific, Orion Series 1800 Fluoride Analyser Prominent, Dulcometer D1C with fluoride sensor FLE 010 SE 72nd Annual Victorian Water Industry Engineers & Operators Conference Page No. 138

ABB, 8231 Fluoride meter ldos, Conex multi fluoride meter The rationale for choosing these meters was to compare two meters with online TISAB reagent addition and two without. The Orion and ABB were selected as the TISAB meters due to both being on our list of approved meters. The Prominent and ldos units were chosen as non TISAB units due to presently using the ldos and the popularity of other water authorities for the Prominent unit. As the Orion unit and ldos units were already in operation Prominent and ABB were approached to supply the trial units. Both suppliers also brought and installed their units free of charge to ensure that the units would be at the optimum operation. l units were installed in the one room off the same sample line. 3.0 THE TRIAL The trial was undertaken over 6 months in an attempt to pick up any difference between the four meters over varying flows, temperatures, plant operations and fluoride masking agents. To compare the four units a 4-20 signal from the unit to SCADA was installed. Once the signals were connected a page was set up on SCADA to compare trending, (See Fig 1). Initially the ldos unit was left out as it was still recording final water and needed to be kept online until one of the other units could replace it for the purpose of the trial. To check accuracy of the on-line units samples were taken from the units to compare results using the method referred to in the DHS Fluoride code The authority must measure the total amount of fluoride in the supplied drinking water. The method for measuring the total fluoride concentration must conform to the ion selective method as described in the current edition of Standard methods for the examination of water and wastewater 4500- F-C. (See Table 2) Figure 1: SCADA trend showing a uniform trend from the trial meters. Note the yellow line of the prominent analyser before and after a calibration. This also assisted identify differences between the TISAB and Non TISAB meter results or referenced interferences. At varying times during the trial, suppliers came and serviced the on-line units to ensure that the meters were still performing at their peak performance. Calibrations were performed on intervals recommended by the suppliers, by GVW staff to ensure ease of calibration from an operators perspective was correctly recorded. 4.0 THE MEASUREMENT OF PERFORMANCE 72nd Annual Victorian Water Industry Engineers & Operators Conference Page No. 139

To compare the performance of the meters a measurement Scorecard was introduced to try and independently measure the optimum meter for GVW needs. The scorecard points system is, 1 is not acceptable to 5 which is excellent. These score where decided on in consultation with operations and water quality departments to ensure objectivity In the cases of price and accuracy the points system is straight forward but in terms of maintenance and service it is purely the general feeling of the panel member based on contact with the supplier. For the purpose of this paper we will look at each unit individually and then the combined scores to evaluate the best unit and in no special order. Table 1: Scorecard Category Orion ABB Prominent ldos Rank Accuracy 5 5 5 5 l rank 1st Reliability 2 4 5 4 Prominent Service 2 5 4 4 ABB Ease of Calibration 1 5 4 4 ABB Parts availability 2 4 5 4 Prominent Size and Position 2 2 4 5 ldos Costs 2 2 4 5 ldos Results 15 26 31 31 ldos /Prominent 5.0 THE SCORING BREAKDOWN 5.1 Accuracy Using the DHS guidelines under The method for measuring the total fluoride concentration must conform to the ion selective method as described in the current edition of Standard methods for the examination of water and wastewater 4500-F-C. Using this method to carryout bench top testing to verify accuracy of each meter to be within the recommended +/- 0.15 mg/l all analysers were found to be within this range and as can be see by Table 2 most results were within +/- 0.1mg/L so all meters scored the maximum 5 points. This was repeated at least once a fortnight for 4 hrs during the trial and each time the results were repeatable. Flouride vs Meter vs Lab 1.2 1 0.8 0.6 Oriion Prominent ABB Lab 0.4 0.2 0 9:45 10:00 10:30 10:45 11:15 11:25 12:50 11:30 12:00 12:15 12:26 72nd Annual Victorian Water Industry Engineers & Operators Conference Page No. 140

Figure 2: Bench top vs online analysers 5.2 Reliability As the trial period was only undertaken for 6 months reliability can only be discussed for that period on the Prominent and the ABB which did not falter in that time. Whereas the ldos and the Orion have been inline for more than a year at the Shepparton plant and a bigger maintenance picture has been constructed. In that time it has been identified that the ldos analyser requires the need to change the probe at least once per year. After two years of running a card fault appeared but was rectified quite easily by our in house Instrument Technician. The Orion in comparison looks to require a fluoride and reference probe change every six months, other failures include changing of the small peristaltic pump, inline filter blockages and card failure that required replacing. The Prominent comes out on top purely because of the limited amount of parts to that could fail compared to the ABB but only time would tell if this was the case. 5.3 Service ABB come out on top for service but very closely followed by ldos and Prominent. This is not only based on the experience of these analysers but also from previous dealings with all four suppliers over several years. ABB went above and beyond to ensure their unit was operating at its peak at all times with many backup visits, whereas Prominent and ldos helped with the installation and back up call support as well as onsite help when asked. Orion on the other hand will only deal over the phone as they are based in Sydney. 5.4 Ease of Calibration ABB again come out on top with their unit have an automatic calibration system that utilises to online standards of 0.2 and 2.0. This calibration can be set to run at any time period and the application at Shepparton worked on a calibration every third day. This system was well received by the operators who agreed the changing of the standards once a month was acceptable. The Prominent came in close behind as did the ldos as both calibrate similar to present online Chlorine analysers within GVW. The Orion procedure is lengthy and requires very close attention which for a novice can take up to an hour to ensure correct calibration. 5.5 Parts Availability Under section 7 Reporting and Auditing on Table 4: Emergency and exceptional notifications of the DHS code of practice, water corporations are required to report to DHS within 24hrs if Fluoride dosing is less than the lower action process limit for a continuous period of >72 hours. Due to this requirement availability of parts is critical to the analysers operation and Prominent come out on top due to availability of parts and support can be sourced in a short time frame. ldos came in close behind except they use a Orion fluoride probe and are subject to lengthy periods in response from Orion, but they do keep some in stock. ABB are also very good but their unit may require an ABB tech as units such as the heating block may require a more specialist input. 72nd Annual Victorian Water Industry Engineers & Operators Conference Page No. 141

5.6 Size and Position Both the ldos and Prominent feature well here as both are small units in comparison to the ABB and Orion (see Figure 3). The ldos unit is the smallest by far and is very easy to install. The ABB and Orion units look to be affected by ambient temperature and prefer to be installed in a room with a constant temperature of around 20 to 25 degs. Figure 3: Orion, Prominent and ABB units 5.7 Purchase and Running Costs The ldos and Prominent units can be purchased under $10, 000 each whereas the Orion and ABB units have price tags above the $20,000 range. Added to this the ongoing cost of online TISAB at $1800 a box (20L), times three times a year makes both these units a costly piece of equipment. l four units appear to require their probes to be changes yearly and so the service costs are similar. As the ldos unit is basically a probe in water it is the cheapest by far in relation to running costs. 6.0 INTERFERENCE TO A QUALITY RESULT It must be pointed out at this part of the paper that the selection of a fluoride meter is for the purpose of an analyser for GVW and its needs and not a recommendation of a one size fits all meter for all water authorities. This is just as relevant when it comes to a fluoride analyser due to chemical compounds that can bind and mask the fluoride ion. Therefore the need for a meter that requires on-line TISAB to unbind the fluoride from compounds such as uminium, Iron and Calcium is a necessity. Levels of aluminium s higher than 3.0mg/l and Iron higher than 200mg/L each introduce an error of 0.1mg/L of the available fluoride at 1.0 mg/l. This is where units utilising TISAB become critical to accuracy. In the case of GVW s water at the Shepparton plant these levels are rarely seen and for the new installations at Cobram, Kyabram and Seymour it is even lower in trace levels as can be seen in Table 2. It can also be argued that if you have uminium s higher than 3.0 mg/l and Iron higher than 200mg/L you would be better off addressing your treatment problems before introducing fluoride. But at times of peak levels on-line TISAB could be your answer. Taking this into consideration added to the results from scorecard the ldos and Prominent come out as the obvious choice as the preferred instrument for GVW s application. It clearly showed in the trial and as can be seen in 72nd Annual Victorian Water Industry Engineers & Operators Conference Page No. 142

Figure 1 that the TISAB and the non TISAB meters recorded a very similar result and the use of TISAB was not showing a any apparent significant difference brought about by separating the masking compounds. It was then decided to move on to show what the difference between the ldos and the Prominent meters might be considering that the Prominent uses a ph compensation inline with the fluoride probe whereas the ldos works on the principle that the ph of the water is between 6.5 and 8.5 and therefore no change in the fluoride result would be seen as stated in the Standard methods for the examination of water and wastewater 4500-F-C state that the fluoride buffer (aka TISAB) is a mixture of CDTA, acetic acid, sodium hydroxide and sodium chloride and is prepared to a ph of 5.3 to 5.5. The fluoride buffer is used to reduce the following interferences: CDTA preferentially complexes interfering cations and releases free fluoride ions In acid solution, F - forms a HF complex but the buffer maintains a ph above 5 to minimise hydrogen fluoride complex formation In alkaline solution hydroxide ion also can interfere with electrode response to fluoride ion whenever the hydroxide ion concentration is greater than one-tenth the concentration of fluoride ion. To investigate this issue both meters were again put online and the ph adjusted to check for drift between the two meters, particular at the higher ph values of 8.0+ (note the Orion was also still online as a comparison). No noticeable or strong conclusion could be drawn from this trial. Table 2: Recorded levels of masking agents Town (Acid Soluble) Ave (Acid Soluble) Highest Total Ave Total Highest Reactive Ave Reactive Highest Fe Ave 8.0 Acknowledgements 72nd Annual Victorian Water Industry Engineers & Operators Conference Page No. 143 Fe Highest Kyabram 0.04 0.79 0.04 0.12 0.02 0.16 0.02 0.14 Seymour 0.05 0.86 0.05 0.96 0.03 0.72 0.13 1.1 Cobram 0.03 0.16 0.03 0.04 0.03 0.14 0.02 0.05 Shepparton 0.05 0.34 0.05 0.4 0.02 0.15 0.03 0.17 7.0 CONCLUSIONS Looking at the comparison of scores it is easy to see that the units without the TISAB rate higher and this is due to the purchase and running costs, as well as the ease of calibration. While the ABB had the easiest of calibration procedures, operators found the need for constant preparing of standards and filling a task they would do without, if the equivalent meter had a simple calibration procedure. The decision that TISAB was not required in our application was recommended and as the new sites would also not require the online addition, the choice was then between the ldos and the Prominent analysers. The ldos and Prominent come out in the scorecard on the same level and it is only the technical difference of ph compensation that separated the two. As ph plays a critical role in online fluoride measurement, the inclusion of the Prominent ph compensation for slight variation just piped the ldos meter out as preferred fluoride analyser.

The Author would like to thank ABB, Prominent and ldos and their respective representatives Chris Krincevski, Frank Pleavin, and Owen Braybrook, for their technical support. 72nd Annual Victorian Water Industry Engineers & Operators Conference Page No. 144