Choose a category. You will be given the answer. You must give the correct question. Click to begin. Instructions for using this template.

Similar documents
Welcome! How do I get a CE Certificate?

6 Handling, collection, and transport of contaminated items General rationale Separation of waste and reusable items at point of

FAQFrequently. Asked Questions. Education & Training. 3M Sterilization Assurance Techline

What Every Infection Preventionist Should Know About the Critical Issues in the Steam Sterilization Process

Medical Device Reprocessing Quality Assurance. 3M All Rights Reserved.

6 Handling, collection, and transport of contaminated items General rationale Separation of waste and reusable items at point of

Welcome! Thank you for attending today s meeting, it will begin shortly.

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

3M s Sterilization Tech Line FAQs Sandra Velte, BA, CSPDT

Specialty Testing of Steam Sterilizers

2. Describe correct actions to take to address sterilization process failures. 3. List possible causes of sterilization process failures.

ANSI/AAMI ST79 A2:2009 Key Changes in the 2009 Amendment

Steam Sterilization Validation for Healthcare Institutions

In the Know about.appropriate Use of 3M Attest Rapid Readout Biological Indicators

THE BASICS OF STERILIZATION

Steam Sterilization Monitoring in the New CSA Standard (Z )

What Dentistry Can Learn from AAMI ST79. Best Practices for device and instrument reprocessing

26/01/2016. A Day in the Life Steam Sterilization Reprocessing. Welcome! House Keeping. From the GoToWebinar page:

Quality Control EQUIPMENT CONTROL. Monitor critical performance characteristics of sterilization, decontamination or cleaning equipment

Technical Data Monograph. VERIFY All-In-One STEAM Reusable Test Pack

Technical Data Monograph. VERIFY Assert Self-Contained Biological Indicators and VERIFY Assert STEAM Process Challenge Devices

QUALITY ASSURANCE IN AN MDRD

Putting Confidence in Your Hands.

8/23/2012. Continuing Education Contact Hours. How much of your formal education focused on sterilization or sterile processing?

Loaner Instrumentation

Immediate-Use Steam Sterilization (IUSS) Tuesday, October 4, :00 pm 1:30 pm EDT

Slide 1. Slide 2. Slide 3. Sponsored by Webber Training Inc. For more information contact Paul Webber

Instructions for Validation of Autoclaves

Best Practice Monitoring for Sterile Processing Professionals

8/27/2015. Learning Objectives. Purpose of Sterilization. To destroy all living pathogenic microorganisms

Quality Control LOAD CONTROL. VERIFY Load Control Products. Use to monitor and release instrumentation with confidence RECORD KEEPING & LABELING

Low Temperature Processing. An Update on Guidelines, Standards and Requirements

McKesson Sterilization Products

ARABIC CANADIAN MEDICAL CENTER CSSD POLICIES AND PROCEDURES

Sterilization Policy. Georgia Regents Medical Center Policy Library. Policy Owner: Epidemiology POLICY STATEMENT

Disinfection & Sterilization in the Ambulatory Surgery Center

The Significance of Validation to US CSSD Managers

Updates to AAMI s ST79 Steam Sterilization Standard Tuesday, January 15, :00 noon 1:30 pm Eastern

STERILIZATION VALIDATION IN THIS SECTION REPROCESSING VALIDATIONS FOR REUSABLE MEDICAL DEVICES. Radiation Sterilization Validation

INSTRUMENT PROCESSING FROM PREP/PACKAGING TO STORAGE. January 2016

MANAGING INFECTION CONTROL

DUAL SPECIES BIOLOGICAL INDICATOR SPORE STRIPS For Monitoring Ethylene Oxide (EO), Steam and Chemiclave Processes

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

REUSABLE MEDICAL DEVICE VALIDATION

Lets Talk Indicators Challenging the process Sterilization. ICAN 5 th November Peter Newson

Testing of routinely sterilized products should

INSTRUMENT CLEANING & STERILISATION FOAMING BATH FORMULATION. Surgistain. Rapid Multi-Enzyme Cleaner. Kimguard Sterile Wrap. Instrument brushes $32.

Your Sterile Processing Partner. Duraholder IPS

Every Step. Every Detail.

Objectives. The Perioperative Nurse s Role 6/24/2016. Instrument Processing & Sterilization Chesapeake Perioperative Consortium 2016

6/12/2016. Objectives. Manufacturers Instructions for Use: Impact on Patient Safety. Background

Your Sterile Processing Partner. Duraholder IPS

Human Tissue Intended for Transplantation Skin, corneas, sclera, bone, heart valves, blood vessels, pericardium, tendons, cartilage, fascia

Manner of Assessment Code (check all that apply) & Surveyor Notes. Yes N/A. Yes. Yes N/A N/A. Yes N/A. N/A Yes N/A

Sterilization Overview from the CDC

01.48 Receiving and Processing Vendor Owned Surgical Instrumentation in the Sterile Processing Department

CSA Z314 Series Standards Understanding the Standards

Advantages. Steam sterilization

Advantages. Steam sterilization

Options for load release

HANDLING OF WRIGHT DISPOSABLE PROPHECY ANKLE INSTRUMENTS

Is Your Sterile Processing Department Ready for Survey?

The Gold Standard in Low Temperature Sterilization: Ethylene Oxide

Biological Monitoring

3/26/2014 SPAULDING CLASSIFICATION OBJECTIVES PRINCIPLES OF DISINFECTION AND STERILIZATION IN THE DENTAL SETTING PROCESSING SEMI CRITICAL OBJECTS

PRINCIPLES OF DISINFECTION AND STERILIZATION IN THE DENTAL SETTING OBJECTIVES

Disinfection & Sterilization

CAN STERILE REALLY BE STERILE?: EFFECTIVE AUTOCLAVING METHODS

The Reusable Surgical Instrument Cycle

Biological Indicators and Their Application in Clinical Sterilization Spores Don t Lie 1

SOP BIO-006 USE OF AUTOCLAVE FOR STERILIZATION OF MATERIALS AND BIOLOGICAL WASTE

UNIT Two. Lesson 1C Sterilization

Quality Assurance with Rigid Containers Katrina Simpson, M.A., CST, CSPDT

SOP Number: IBC-PP-019 Revision Number: 2 Section: Biosafety. Author: Patricia Cox Effective Date: 8/18/10

FREQUENTLY ASKED QUESTIONS IPAC Lapses

3/11/ M Sterile U Network 3M Sterile U Web Meeting March 11, Welcome! Topic: An Overview of ANSI/AAMI ST58: 2013

CDWA3 / CDWA4 CDWAH. Page 4. BASKET ZONE: water pressure, spray system performance, detergent chemistry and concentration, temperature.


Loaner Programme Guidance

Loaner Programme Guidance

CERTIFICATE OF CONFORMANCE Mesa Laboratories, Inc. 625 Zoot Way, Bozeman, MT Phone: (303)

Facility: Sterile Processing Assessment Date: CRITERIA ANSI/AAMI COMPLIANT Number Y N N/A Point of Use Gross contaminant is removed with

New National Standard of Canada CAN/CSA-Z Canadian medical device reprocessing

Products and Guidelines for Enhanced Office Safety

VHP Sterilization and Prion Inactivation

GUIDELINE C-17. Non-Incineration Technologies for Treatment of Biomedical Waste (Procedures for Microbiological Testing)

Loaner Program Guidance

Disinfection and sterilisation

A Sterile Processing User s Guide

Innovative H 2 O 2 V-Phase biodecontamination solutions

S.M.A.R.T.Green Test Pack for Prevacuum Sterilizers Technology Overview

Endoscope Washer Disinfector Cleaning Process Challenge Devices Research & Validation

Reprocessing Single-use Medical Devices

One such problem is blood residual inside the channels of a robotic arm.

STERILIZATION SOLUTIONS

Not to be reproduced - AGPAL & QIP

Validation and Control of Porous Load Sterilisation

Responses to Questions for SYSTEM 1E Process Monitoring and Validation Webinar

Biological and chemical indicators

SterilAmp II Geobacillus stearothermophilus

Transcription:

Instructions for using this template. Remember this is Jeopardy, so where I have written Answer this is the prompt the players will see, and where I have Question should be the player s response. To enter your questions and answers, click once on the text on the slide, then highlight and just type over what s there to replace it. If you hit Delete or Backspace, it sometimes makes the text box disappear. When clicking on the slide to move to the next appropriate slide, be sure you see the hand, not the arrow. (If you put your cursor over a text box, it will be an arrow and WILL NOT take you to the right location.) Answer: Roses Question: What is New York s state flower? Answer: Sugar Maple Question: What is New York s state tree? Answer: Brook Trout Question: What is New York s state fish? Choose a category. You will be given the answer. You must give the correct question. Click to begin. 1

Sterilizer Testing Load Release Monitoring Agencies / Sterilization Current Tools Associations Methods SPD Issues 10 Point 10 Point 10 Point 10 Point 10 Point 10 Point 20 Points 20 Points 20 Points 20 Points 20 Points 20 Points 30 Points 30 Points 30 Points 30 Points 30 Points 30 Points Click here for Final Jeopardy 40 Points 50 Points 40 Points 50 Points 40 Points 40 Points 40 Points 40 Points 50 Points 50 Points 50 Points 50 Points A daily test conducted in prevacuum steam sterilizers to evaluate the efficacy of the vacuum system to remove residual air from the chamber. What is a Bowie-Dick test? Testing that is conducted after sterilizer installation, relocation, malfunction, major repairs, or sterilization process failures. What is qualification testing? 2

The recommended frequency of routine efficacy testing with a biological indicator for ethylene oxide sterilization cycles. What is every load? Steam sterilization cycles that should be routinely tested with biological and chemical indicators in an empty chamber. What are IUSS (flash) sterilization cycles? The recommended number and order of the required cycles for conducting qualification testing in a prevacuum steam sterilizer. What is three consecutive cycles with a biological indicator process challenge device followed by three consecutive cycles with a Bowie-Dick test? 3

Monitoring tool that should be read and initialed for each cycle by a trained and knowledgeable person. What are the physical monitors (e.g., sterilizer printout)? A medical device that should be quarantined until the biological indicator result is known. What is an implant? The monitoring tool contained in the biological indicator process challenge device that can be used to release implants in defined and documented emergencies only. What is a Class 5 integrator? 4

A user-assembled or commercially available monitoring tool designed to constitute a defined resistance to a sterilization process and used to assess performance of the process. What is a Process Challenge Device (PCD)? A process challenge device that contains one of the following: 1. a BI, 2. a BI and a Class 5 integrator, 3. a Class 5 integrator, or 4. a Class 6 CI may be used to monitor this type of load. What are non-implant loads? Class of chemical indicator that distinguishes between processed and unprocessed items. What is Class 1? 5

The charts, gauges, and printouts on the equipment that verify the parameters of the sterilization cycle were met. What are physical monitors? A biological indicator that ensures the incubation temperature is correct, the spores in the biological indicator were alive before sterilization, and the culture media is able to promote growth. What is a positive control biological indicator? Class of chemical indicator whose performance in the steam sterilization process correlates to the performance of a biological indicator at three time/temperature relationships. What is Class 5? 6

The type of spore contained in steam sterilization biological indicators. What is Geobacillus stearothermophilus? Federal regulatory agency whose mission is to prevent work-related injuries, illnesses, and deaths. What is OSHA (Occupational Safety and Health Administration)? A national consensus association that develops recommended practices for the sterilization of products in health care facilities, including ST79. What is AAMI (Association for the Advancement of Medical Instrumentation)? 7

Federal agency responsible for protecting the public health by assuring the safety, efficacy, and security of human and veterinary drugs, biological products, medical devices, our nation s food supply, cosmetics, and products that emit radiation. What is the US Food and Drug Administration (FDA)? Federal agency which published the Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008 What is the Centers for Disease Control and Protection (CDC)? Federal agency that will no longer reimburse healthcare facilities for costs related to certain healthcare acquired infections that could have reasonably been prevented through the use of evidence based guidelines. What is CMS (Centers for Medicare and Medicaid Services)? 8

Steam sterilization cycle in which air is removed from the chamber and the load by means of a series of pressure and vacuum excursions. What is a prevacuum cycle? A sterilization cycle in which incoming steam displaces residual air through a port or drain in or near the bottom of the sterilizer chamber. What is a gravity displacement steam sterilization cycle? A process designed for the steam sterilization of patient care items for immediate use. What is IUSS (flash) sterilization? 9

Period of time during a sterilization cycle for which the process parameters are maintained within their specified tolerances. What is exposure time? Method of sterilization for heat- and/or moisturesensitive medical devices that employs an alkylating sterilant What is ethylene oxide sterilization? Surgical instrumentation borrowed from a vendor or a neighboring healthcare facility. What are loaners? 10

A steam sterilization cycle having an exposure phase longer than standard cycles. What is an extended cycle? Legislation passed by a state requiring certification or licensing of employees working in sterile processing departments. What is mandatory certification? A degenerative neurological disorder of humans caused by prions (proteinaceous infectious agents that exhibit unusual resistance to conventional disinfection and sterilization procedures). What is Creutzfeldt- Jakob disease (CJD)? 11

A non-infectious, acute inflammatory response following intraocular surgery. What is Toxic Anterior Segment Syndrome (TASS)? Make your wager Certificate of Attendance for completing the seminar: 3M Attest Sterile U Network Sterilization Test Your Knowledge Jeopardy Workshop 3M Health Care Inservice Approved by the Certification Board for Sterile Processing and Distribution (CBSPD) for 1.0 Contact Hour Approval Code # 1090BCOR09 IAHCSMM has awarded 1.0 Contact Hour Approval Code #00070210 3M 2008. July 21, 2014 Date Memorial Sloan Kettering Location Mario Perella 3M Infection Prevention 12

Certificate of Attendance Presented to For Completing 3M Attest Sterile U Network Sterilization Test Your Knowledge Jeopardy Workshop Date: June 19, 2014 Location: Abington Memorial Hospital 3M Health Care Provider approved by the California Board of Registered Nursing, Provider number CEP 5770 for 1 Contact Hour This certificate must be retained by the licensee for a period of four years after the course ends. 13