USING OLI TO DESIGN SOLUTION TO MINIMIZE THE CORROSION OF CRUDE DISTILLATION TOWERS

Similar documents
Corrosion Potential - Refinery Overhead Systems

Applications of Aqueous Process Modeling to Petroleum Refinery Corrosion Control

White Paper. Impact of Opportunity Crudes on Fouling in Preheat, distillation, and furnace systems

Unit 5. Crude Oil Desalting

In 1965, while working as a

Salt deposition in FCC gas concentration

Stop bleeding caustic: Parameters for Designing and Operating an efficient LPG treating unit

Stephen M. Patera, Sales Manager, LHI Metals. October 6-9, 2013 Caesars Palace, Las Vegas, Nevada, USA

Integrating Risk-Based Inspection Recommendations with Inspection Programs and Integrity Operating Windows

Corrosion Monitoring Solutions for Hydroprocessing Units

Addressing the Challenges Associated with Canadian Crudes

Lowering Column Tops Temperature to Improve Product Yields, While Avoiding Penalty due to Salting & Corrosion

Amines in Air Cooled Condensers San Diego Annual Conference September 24, Bill Stroman

Two examples of steady state simulation with HYSYS at GALPenergia Sines Refinery

Removal of Heat Stable Salts A Solution to Amine Plant Operational Problems

Ralph Navarrete and George Duggan, Baker Hughes Inc., USA,

The naphtha hydrotreater

Fouling mitigation on the Preheat, Furnace. Convection Section and vaporizer

Figure 1. Electrodialysis Stack Saltworks Technologies

Taravosh Jam Design & Engineering Co.

Corrosion Management Methods of High TAN Crude. Case study: (Fula Crude Oil-Sudan)

A New Optimisation Based Retrofit Approach for Revamping an Egyptian Crude Oil Distillation Unit

specific amine large changes Environmental to acid

Study evaluates two amine options for gas sweetening

Fate of Ammonia in Refinery Amine Systems

Modular Oil & Gas Equipment Onshore & Offshore

SUEZ helps refineries to save time, reduce energy consumption, emissions and waste by efficient decontamination

Chemistry of Petrochemical Processes

AMINE SYSTEM FAILURES IN SOUR SERVICE

Coker Safety and Reliability Lessons Learned

Forensic testing revealed the mechanism of under-deposit corrosion in exchanger tubes, a problem solved by replacement with hyper-duplex steel

Atmospheric distillation of crude oil

Delayed Coking Process Design, Operations and Optimization. Canada Coking Conference October 22-26, 2012 Fort McMurray, Alberta

Assessment of Solvent Degradation within a Global Process Model of Post-Combustion CO 2 Capture

using EDI to meet the needs of pure water production

Corrosion monitoring solution for sour water stripping units

Sour Water Stripper Performance in the Presence of Heat Stable Salts

Technical Services & Process Technology Hydrocarbon Desulfurization

Innovative Solutions. for Your Gas Processing Needs

Heavy Oil and Bitumen Analytical. Understanding Their Capabilities

AMINE GAS SWEETENING & SULPHUR RECOVERY

2011 BRIMSTONE SULFUR SYMPOSIUM. Fundamentals 2011: Ammonia Destruction in SRU Furnaces

Water Management in Process Plants. David A. Puckett University of Oklahoma Department of Chemical, Biological, and Materials Engineering 5/2/2008

Nathan A. Hatcher and Ralph H. Weiland, Optimized Gas Treating Inc., USA, discuss the fate of ammonia in refinery amine systems.

Lenntech. Using EDI to Meet the Needs of Pure Water Production. EDI Process. Summary. Introduction

Mass Transfer Rate Modeling Basics. Nathan A. Hatcher, P.E. AIChE South Texas Section Dinner Pellazio Banquet Hall, Houston TX September 11, 2014

Boiler Water Chemistry: Getting From the Source to the Boiler Colleen M. Layman, PE

Water Conservation Initiatives Burnaby Refinery

Refinery SRU s Tail Gas Handling Options. 2 nd Middle East Sulphur Plant Operations Network Forum Abu Dhabi October 18-20, 2015

Reducing FCC Turnaround Costs Focus on Speed & Safety. Brent Dell Sr. Technical Engineer

Reducing FCC Turnaround Costs Focus on Speed & Safety. Brent Dell Sr. Technical Engineer

BIOGAS CLEAN-UP TECHNOLOGIES

AFPM 2018 Operations & Process Technology Summit

Preparing Amine, Acid Gas and Sour Water Vessels for Safe Entry with the Vapor-phase Application of an Organic Solvent and Pyrophoric Oxidizing Agent

Discusser: Melonie Myszczyszyn, CNRL Facilities Engineer, Alberta, Canada

H 2 S Treating Options and Factors Influencing Decisions. June 30, 2016

Purification of oligonucleotides by anion exchange chromatography

Sour water stripping (SWS)

Study and examining the processing parameters on function of MDEA and DEA solvents for measuring removal units of CO 2 and H 2 S

Water Fit for Use. Avoiding the Unintended Consequences of Good Intentions

Hydrocarbon processing Separation processes - distillation. English version based on the presentation of István Rabi, held on

Treating Technologies of Shell Global Solutions for Natural Gas and Refinery Gas

Initially, quality issues for investigation will not be limited and may include issues associated with:

optimize ethylene fractionation train

How OLI Has Been Used to Tackle the Nasty Problem of Refinery Sour Water DART

The Use of MDEA and Mixtures of Amines for Bulk CO 2. Removal

Problems with Deposits

REAL-TIME PREDICTIVE ANALYTICS AND CORROSION MONITORING WITH PREDICT -RT

Information Centre Nitric Acid Plants. Kittiwake Procal Ltd Page 1 of 6

Debottlenecking a refinery fuel gas absorber

CCR MEG RECLAIMING TECHNOLOGY: FROM MOBILE UNITS TO THE LARGEST RECLAIMING UNIT IN THE WORLD

Use of Reclamation for Amine Hygiene Management By James Jenkins Shell Global Solutions (US) Inc. Chris Daniels Chem Group Services, LLC

PHYSICAL MEASUREMENTS CENTER IN ARTIGUELOUTAN. Total E&P Alternative Subsurface Data (TEP ASD)

Instructor: Dr. Istadi ( )

ENGINEERING STANDARD FOR PROCESS DESIGN OF CRUDE OIL ELECTROSTATIC DESALTERS ORIGINAL EDITION JULY 1995

Oxidation And Degradation Products Of Common Oxygen Scavengers

BOILER FEED WATER AND ITS TREATMENTS

News. Power Generation 11. ph Control Reduces Acid Consumption in Neutralization Process up to 90 % Perspectives in Pure Water Analytics THORNTON

Adsorbent Purification Solutions for Refining and Petrochemicals

Atmospheric Corrosion

Crude Oil Quality Group (COQG)

How A Vertical Tube Falling Film Evaporator Can Be Used to Deliver the Lowest Total Life Cycle Cost for Alberta Produced Water Treatment

Chapter 1 Principles of ion exchange

ProMax. Use It. Love It. Bryan Research & Engineering, Inc. BR&E. with TSWEET & PROSIM Process Simulation Software

Removal of CO2 and H2S using Aqueous Alkanolamine Solusions

SODIUM SULPHITE BASED WATER TREATMENT PROGRAM FOR CLOSED CHILLED WATER SYSTEMS

Combatting HCl Acid-Dewpoint Corrosion at The Geysers. John Farison Calpine Corporation

1. Scaling. H.O.: H-5/21, KRISHNA NAGAR, DELHI Tel.: , Fax:

On-Line Diagnostics Techniques in the Oil, Gas, and Chemical Industry

A Single Analyzer Solution for Refinery Flare Emissions Monitoring (40 CFR 60 Subpart Ja) Using Mass Spectrometry

Hydrazine, sodium and dissolved oxygen measurement The power of boiler chemistry

the effects of ammonia and organic amines on the water chemistry of gas turbine heat recovery steam generators and associated equipment

ACC Chemistry and the Use of Amines Mike Caravaggio ACC Users Group Xi an, Shanxi October 2015

Pur-IX Continuous Nitrate Removal Ion Exchange System

PRE-FEASIBILITY REPORT ON

Thermal Oxidation plants February 2016

Sridhar Srinivasan June 20, 2017 REAL TIME PREDICTIVE ANALYTICS AND CORROSION MANAGEMENT WITH PREDICT -RT

Effects of Piperazine on Removal of Hydrogen Sulfide from Liquefied Petroleum Gas (LPG) using Aqueous Methyl Diethanol Amine (MDEA)

Cyclone Technology protects analyzer systems for unrivalled reliability and tops productivity

CONDENSATE-FEEDWATER-BOILER SYSTEM ON-LINE ANALYZERS. On-Line Analyzer Sample Point Alarm Points Comments

Transcription:

USING OLI TO DESIGN SOLUTION TO MINIMIZE THE CORROSION OF CRUDE DISTILLATION TOWERS Benoit ALBINET TOTAL, Belgium Sheyla Camperos TOTAL, France Rasika Nimkar OLI

THE ISSUE More and more crude oil contains impurities that cause corrosion and fouling issues in the crude distillation column Typical damages found are mainly in the top trays, heat exchangers and lines as shown below (yellow zone). Typical unit arrangement, including: 2 stage desalters, a preflash and a main fractionnator: Titre de la Présentation Lieu et Pays Date Jour Mois Année 2

THE ISSUE The corrosion and fouling can cause: - Bad efficiency of heat echangers and associated loss of opportunity and maintenance cost (cleaning, repair) - Slowdown of the unit (decrease of the throughput) as the fouling of the internal trays maght end-up in flooding and unstable operation - Loss of fractionnation leading to valorization losses - Larger maintenance scope and cost during Turn around - Unscheduled shutdown if the cycle of 5 years can no longer be maintained Normal behavior Some flooding Flooded New Tray Partially Fouled Tray Totally Fouled Tray Line fouled Titre de la Présentation Lieu et Pays Date Jour Mois Année 3

THE SOURCE OF THE PROBLEM The analysis of the deposit found in the corroded/fouled zone often revealed the presence of Corrosion products type Iron sulphide or iron oxides (consequence of the corrosion) Chlorides in large quantity (could be several thousand of ppm) Nitrogen species balancing chloride as: Methyl diethanol amine (MDEA), Mono-ethanolamine (EA), Di-ethanolamine (DEA) or Monomethylamine (MMA) or Ammonia (NH3) From a deposit analysis fround in the top pumparound heaxchanger (TPA) back in 2012, we found Significant amount of chloride and MDEA, and traces of NH3, EA, and DEA. Why amine salts are formed inside the column? Titre de la Présentation Lieu et Pays Date Jour Mois Année 4

FRACTIONNATION COLUMN We know that a preflash/main fractionnator configuration is supposed to be structually protected from salt issues as shown below. NH3 and HCl are mainly splitted each other and the formation of corrosive NH4Cl should not occur in the columns. Main NH3 Chlorides HCL few NH3 Titre de la Présentation Lieu et Pays Date Jour Mois Année 5

FRACTIONNATION COLUMN What is true for NH3 is might be not for other contaminants. Oli was used to check if the thermodycnics predict the presence of these contaminants in the TPA area (located between the jet and the Heavy Naphta draw). The presence of corrosive amines are clearly predicted by OLI in the area where the corrosion/fouling was found *Split PF/MF= percentage of species sent to the preflash in comparaison with the main fractionnator How to protect the column? By increasing the scope of the desalter. Titre de la Présentation Lieu et Pays Date Jour Mois Année 6

UNDERSTANDING THE BEHAVIOR OF NITROGEN SPECIES If the conditions to the desalter are set such that the nitrogen species (coming either from the crude or the water) are getting out of the system with the brine water of the desalter, dowstream columns should be protected. Desalting Block Fractionation block Titre de la Présentation Lieu et Pays Date Jour Mois Année 7

DESALTER (1) Typical desalter arrangement is shown below. Main objective: Extract chloride salt (NaCl, MgCl2, CaCl2) from crude oil to prevent HCl corrosion. Secondary objective need to go to a nitrogen contaminants removal. Source of Nitrogen contamination: - Internal: from the process water: DEA, MDEA or Neutralizer used in the overhead column when recylced back to the desalter - External: from crude oil through the H2S scavengers used: Typical two stages desalter arrangement Titre de la Présentation Lieu et Pays Date Jour Mois Année 8

DESALTER (2) Nitrogen species balance was first assessed by sampling crude and water streams and analysizing amine species by ionic chromatography (directly in water or via extraction in water for oil sample). Then OLI was used to simulate the unit and check the consistency of the results from OLI and the one found in the field. Two cases used at low and high NH3 in the desalter water. Field data Case 1 NH3 EA MOPA in water 160 ppm 19.4 ppm 160 ppm out water 77 ppm 14.2 ppm 77 ppm out oil 5.9 ppm 0.9 ppm 0.4 ppm Case 2 NH3 EA MOPA in water 26 ppm 19.4 ppm 28 ppm out water 48 ppm 14.2 ppm 24 ppm out oil <1 ppm 0.3 ppm 0.8 ppm OLI out oil 6.1 ppm 0.41 ppm 0.59 ppm OLI out oil 0.9 ppm 0.43 ppm 0.62 ppm As one can see consistency is good. There are no exact mach between OLI and the field but not expected as the accuracy of the measurement in the field is not very high (sampling, sample stability, extraction efficiency, low levels measured are several reasons for results deviations). Titre de la Présentation Lieu et Pays Date Jour Mois Année 9

DESALTER (3) Field data and extrapolation of the effect of ph using OLI. Titre de la Présentation Lieu et Pays Date Jour Mois Année 10

DESALTER (4) From OLI simulation, acid consumption can be optimized based on the quantity of contaminants removed Titre de la Présentation Lieu et Pays Date Jour Mois Année 11

DESALTER (5) Neutralization curve were also done on real sample to compare with OLI with a good similarity. Titre de la Présentation Lieu et Pays Date Jour Mois Année 12

DESALTER (6) The sensitivity to crude contaminants was also checked with OLI (left graph) - The effect of the pka of each amine clearly impacts the needed for acid - Very usefull to design the injection skid One indicator was also developed to detect contaminants based on the delta ph in/out of the desalter (right graph) compare to field data. The spectra developed suggest the presence of contaminated crude when the operating point are closer to the blue curve (abnormal variation of ph). Titre de la Présentation Lieu et Pays Date Jour Mois Année 13

CONCLUSION OLI was used to understand the origin of the corrosion/fouling found in the main fractionnator of crude Ditillation column The data clearly indicates the absence of structural protection (split) allowed by the preflash for some corrosive species as MDEA, EA. OLI was able to confirm the location of the more severe area for these slat formation(btween jet and heavy naphtha cut in the example considered). OLI was then used to predict the impact of running the desalter at lower ph on the control of the contaminants. A tool was developped, based on OLI estimation, to detect contaminated crude oil. This would allow to alert the site and identify suspicious supply. More work to come to fully validate salt deposition prediction and dewpoint chemistry. Titre de la Présentation Lieu et Pays Date Jour Mois Année 14