G Sep Size Exclusion Columns

Similar documents
Userguide: SepFast Gel Filtration columns

G-Sep Ion Exchange Agarose Fast Flow

G-Sep Ion Exchange Agarose Fast Flow

G Trap Ion Exchange Selection Kit

G-Sep Ni-NTA Agarose Fast Flow

G-Sep IDA Agarose Fast Flow

The above media is designed to capture antibodies or other molecules of similar size.

The above media is designed to purify antibodies from aggregates and other impurities.

Cellufine MAX Q-r, Cellufine MAX Q-h

ProteIndex Chemical-Tolerant Ni-Penta Agarose. Prepacked Cartridge. 6 FF Prepacked Cartridge, 5 x 1 ml settled resin

Table of contents. p. 2

Q SepFast HighRes. DEAE SepFast TM HighRes S SepFast TM HighRes CM SepFast TM HighRes

Phenyl Sepharose High Performance Butyl Sepharose High Performance

Column-PROTEIN- Concentrate

Blue Sepharose CL-6B. instructions

FastPure Spin Columns (Mini and Midi)

HiTrap Desalting, 5 ml

Nuvia S and Q High-Capacity Ion Exchange Media Instruction Manual

Instructions AD Hydrophobic interaction

UNOsphere Q & S Ion Exchange Media. Instruction Manual ...

... Macro-Prep 25 Ion Exchange Supports. Instruction Manual

Sulfhydryl Immobilization Kit for Proteins

Immobilized Protein G

3. Close the bottom end of the column and apply the packing device on top. Pump water through the upper adaptor to remove air.

Immobilized Streptavidin Resin

Arginine Sepharose 4B

Operating Instructions Heparin Mimetic Affinity

Superdex prep grade. GE Healthcare Life Sciences

Glutathione Resin. (Cat. # , , , ) think proteins! think G-Biosciences

Hydrophobic Chromatography

Red Sepharose CL-6B INSTRUCTIONS

Glutathione Resin. (Cat. # , , , ) think proteins! think G-Biosciences

2 5 ADP Sepharose 4B. GE Healthcare Life Sciences

SOURCE 15Q and SOURCE 15S

Mimetic Blue Affinity Adsorbents Mimetic Blue 1 P6XL, Mimetic Blue SA P6XL Mimetic Blue SA HL P6XL, Mimetic Blue ELISA Kit

5 AMP Sepharose 4B. instructions

NHS-Activated Agarose (Dry Form)

Cobalt Chelating Resin

Nuvia HR-S Strong Cation Exchange Media Instruction Manual

GST Elution Buffer. (Cat. # ) think proteins! think G-Biosciences

WorkBeads Protein A INSTRUCTIONS IN

1. Connect the column to the chromatography system, syringe or pump.

HOOK Activated Agarose (Amine Reactive)

AFFINITY HIS-TAG PURIFICATION

BabyBio S BabyBio Q BabyBio DEAE

Nickel Chelating Resin Spin Columns

GE Healthcare. Sephacryl High Resolution

ProteoEnrich CAT-X SEC Kit Merck: Lichrospher Composition. Silica Particle size. 25 µm particles with 6 nm pore size Ligand SO 3

GORE. Protein Capture Devices. Operating Instructions Contents. Product Description Device Characteristics... 2 General Handling...

HOOK 6X His Protein Purification (Bacteria)

Phenyl Sepharose CL-4B

I Introduction II Product Description III Immobilized Metal Ion Affinity Chromatography (IMAC)... 4

Gelatin Sepharose. instructions

Sartobind IEX nano 3 ml

AFFINITY HIS-TAG PURIFICATION

Superdex 200 HR 10/30 INSTRUCTIONS

Module 16: Gel filtration: Principle, Methodology & applications. Dr. Savita Yadav Professor Department of Biophysics AIIMS, New Delhi

Fab Fragmentation Kit

Ni Sepharose excel, 100 ml and 500 ml HisTrap excel, 1 ml and 5 ml

Phenyl Sepharose High Performance

Glutathione Agarose Resin User s Guide

HOOK 6X His Protein Spin Purification (Bacteria)

Data File. HiLoad Superdex 30 prep grade HiLoad Superdex 75 prep grade HiLoad Superdex 200 prep grade. Pre-packed gel filtration columns

AminTRAP HIS Prepacked Column

XIT Genomic DNA from Tissue

Nuvia cprime Hydrophobic Cation Exchange Media

HiTrap MabSelect, 1 ml and 5 ml HiTrap MabSelect Xtra, 1 ml and 5 ml

Code No. Designation No. supplied

TECHNICAL BULLETIN. HIS-Select HF Nickel Affinity Gel. Catalog Number H0537 Storage Temperature 2 8 C

Superose 6 HR 10/30 Superose 12 HR 10/30

HiTrap Desalting HiPrep 26/10 Desalting

INSTRUCTION IN

Sephacryl S-100, S-200, S-300, S-400, S-500 High Resolution

Fab Fragmentation (Micro)

Q Sepharose XL Q Sepharose XL virus licensed SP Sepharose XL

DOW AMBERCHROM HPS60 Cation Exchange Media. User Guide

Capto S Capto Q Capto DEAE

HOOK 6X His Protein Purification (Yeast)

1 ml gel corresponds to ml of 75% (v/v) Glutathione Agarose suspension.

INSTRUCTIONS The resins are adapted to work mainly in native conditions like denaturing.

Technical Manual No Update date

Econo-Pac High Capacity Ion Exchange Cartridges, 5 ml Instruction Manual. Catalog Numbers , ,

XIT Genomic DNA from Cells

Q Sepharose High Performance

AFFINITY GST PURIFICATION

AFFINITY GST PURIFICATION

Table 1, Performance characteristics of Cellufine SPA-HC

Econo-Pac Serum IgG Purification Kit and Econo-Pac Serum IgG Purification Columns Instruction Manual Catalog Numbers and

CNBr-activated Sepharose 4B

Capto MMC. GE Healthcare Life Sciences

Nickel-NTA Agarose Suspension

Cellufine MAX HIC Butyl, Phenyl Technical Data Sheet

HiTrap Heparin HP, 1 ml and 5 ml

TechnicalNote. BAKERBOND Multimode Ion Exchange Chromatography Media. Introduction. BAKERBOND PolyPEI

Column Packing of Cellufine A-500 ion exchange chromatography resin

HiScreen MabSelect SuRe HiScreen MabSelect SuRe LX HiScreen MabSelect HiScreen MabSelect Xtra

XIT Genomic DNA from Buccal Cells

AFFINITY HIS-TAG PURIFICATION

UNOsphere SUPrA Affinity Chromatography Media

# , , T)

Transcription:

G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name G Sep Size Exclusion Columns (Cat. # 786 1297, 786 1298, 786 1300, 786 1301, 786 1302, 786 1304) think proteins! think G-Biosciences www.gbiosciences.com

INTRODUCTION... 3 ITEM(S) SUPPLIED... 3 STORAGE CONDITIONS... 3 ADDITIONAL ITEMS REQUIRED... 3 SECIFICATIONS... 4 INSTRUCTION FOR USE... 4 OPERATION... 5 EQUILIBRATION... 5 SAMPLE PREPARATION... 5 ELUTION... 5 STORAGE... 6 RELATED PRODUCTS... 6 Page 2 of 8

INTRODUCTION Size Exclusion Chromatography or gel filtration is a widely used technique for separation of proteins and other molecules based on their sizes. G Sep Size Exclusion Columns are available in there column formats including 11/30, 16/60 and 26/60 and with two separation range, 3 kda to 70 KDa and 6 kda to 600 kda. G Sep Size Exclusion Columns have non adjustable end adaptors. G Sep Size Exclusion Column resin design is made to offer high recovery and high selectivity. The resin offers high resolution, high selectivity, high recovery and is highly scalable. In addition, the resin has excellent physical and mechanical stability and low on cost. The resin is highly cross linked polysaccharide composite of dextran and agarose and is stable to most of the aqueous and organic solvents used in chromatography. ITEM(S) SUPPLIED Cat. # Description Size 786 1297 786 1298 786 1300 786 1301 786 1302 786 1304 G Sep Size Exclusion Column (11 mm ID; 30 cm length, 3 70 kda HR resin) G Sep Size Exclusion Column (16 mm ID; 60 cm length, 3 70 kda HR resin) G Sep Size Exclusion Column (26 mm ID; 60 cm length, 3 70 kda HR resin) G Sep Size Exclusion Column (11 mm ID; 30 cm length, 6 600 kda HR resin) G Sep Size Exclusion Column (16 mm ID; 60 cm length, 6 600 kda HR resin) G Sep Size Exclusion Column (26 mm ID; 60 cm length, 6 600 kda HR resin) STORAGE CONDITIONS G Sep Size Exclusion Column are supplied at ambient temperature. Upon arrival, store it at 4 C, DO NOT FREEZE. This product is stable for 1 year. The resin in the column should be stored in 20% ethanol at 4 C after use. ADDITIONAL ITEMS REQUIRED Sample containing molecules to be separated using the G Sep Size Exclusion Column. Equilibration/starting buffer and elution buffer Operation Unit: Chromatography system 20% ethanol. Page 3 of 8

SECIFICATIONS Features Matrix Particle size (µm) Column body maximum pressure Maximum resin pressure Operating Flow velocity ph stability Working temperature Chemical stability Storage Precaution G Sep Size Exclusion Column, G Sep Size Exclusion Column, 3 70kDa HR resin 6 600kDa HR resin Highly cross linked polysaccharide composite of Dextran and Agarose 35 µm (in the range of 20 50 µm) 6 Bar, 0.6 MPa (3 70 Columns) 5 Bar, 0.5 MPa (6 600 Columns) 4 Bar 3 Bar 10 50 cm/hr; 0.15 0.8 ml/min (11/30 Columns), 0.30 1.6 ml/min (16/60 Columns), 0.80 4.4 ml/min (26/60 Columns) 2 14 (short term) and 3 12 (long term) +4 C to +30 C All commonly used aqueous buffers, 1 M acetic acid, 1 M NaOH, 6 M guanidine hydrochloride, 8M Urea, 30% isopropanol, 20% ethanol (concentration of alcohol should not exceed 30% v/v) Storage buffer with 0.02% sodium azide or 20 % ethanol Avoid oxidizing agents INSTRUCTION FOR USE Instructions for handling and use of G Sep Size Exclusion Columns. 1. The column is sealed at both ends by mildly pressurized syringes filled with 20% ethanol. 2. Remove the column from packing material and always hold the column from the middle. NOTE: Do not hold the column by syringe side. 3. Check the labeling for orientation; firmly clamp the column at two points in a vertical position using an appropriate support. 4. Disconnect the top syringe first by gently unwrapping the rubber band from the top syringe. 5. Hold the column body from middle and unscrew the 1/16 tubing adaptor from the top of the column. NOTE: Keep the syringe tubing aside for later use. 6. Connect the chromatography system to the top of column via its female 1/16 thread connection. NOTE: For M6 connectors tubing connection, a 1/16 male thread M6 female thread connector is required. 7. Keep the flow rate at approximately 0.5 ml/min and fill the thread cavity with liquid before tightening the connection to avoid air bubbles. 8. Unwrap the rubber band from bottom syringe gently. Page 4 of 8

9. Hold the column and unscrew the 1/16 tubing adaptor from the bottom of the column. NOTE: Keep the syringe tubing aside for later use. 10. Connect the bottom of the column to the chromatography system. OPERATION Equilibration 1. Equilibrate the column by passing at least 2 column volumes (CV) of equilibration/starting buffer at a flow rate of 1 ml/min for 16 mm column and 2.5 ml/min for 26 mm column before loading sample. Equilibrate until stable baseline is reached. 2. Re equilibration between runs is not necessary. In case denatured proteins or lipids are not eluted with one column volume, the cleaning in place procedure (CIP) should be done to ensure complete removal. Sample preparation Before application the sample should be centrifuged or filtered through a 0.45μm filter to remove any particulate matter. Recommended sample volume is 0.1 1% v/v of the packed bed volume. Elution It is recommended to use a buffer with an ionic strength equivalent of 0.15 M NaCl or greater to avoid any unwanted ionic interactions between the solute molecule and the resin. NOTE: The recommended flow velocity is 10 50 cm/hr (0.15 0.8 ml/min for 11/30 columns, 0.3 1.6 ml/min for 16/600 columns and 0.8 4.4 ml/min for 26/600 columns. The lower the flow velocity, the better resolution can be attained. Maintenance The resin can be re used depending upon the application. Cleaning in place (CIP) procedure is used to remove strongly bound materials including lipids, endotoxins and denatured proteins from the resin surface. Cleaning in place (CIP) CIP prevents the bulid up of contaminants in the packed bed and helps to maintain te column performance. The frequency of CIP depends upon the specific application and the procedure depend the type of contaminants presents. Below is general guideline for CIP. Optimization is required depending upon the specific use. Method 1: Pass 0.5 M NaOH through resin with reverse flow direction at linear flow velocity of 15 25 cm/hr for 1 2 hrs. Page 5 of 8

Method 2: Pass 2 bed volumes of 0.1 0.5% detergent in basic or acidic solution at a linear flow velocity of 15 25 cm/hr with reverse flow direction. Remove the residual detergent by washing the column with 5 bed volumes of ethanol or any other alcohol upto 30%v/v or diluted organic solvents. Method3: Pass 2 bed volumes of dilute organic solvent at linear flow rate of 15 25 cm/hr with reversed flow direction. Organic solvents should be applied in increasing concentration gradients to avoid formation of air bubbles. After CIP, for all the three methods, the column should be equilibrated with at least 3 CV of equilibration buffer before next run. Sanitization: Sanitize the column with at least one bed volume of 0.5 1.0 M NaOH at flow rate of 10 20 cm/hr. After sanitization equilibrate the column with 3 5 CVs of equilibration buffer. STORAGE 1. Before storage, pass 2 CV of 20% ethanol at a linear flow velocity 30 cm/hr. 2. Attach the leur thread adaptors and pre fill both storage syringes with 4 5 ml 20% ethanol. Invert syringes and push out air bubbles. NOTE: Ensure that the remaining fill volume is more than 3 ml. 3. Keeping the pump running at rate 1 ml/min, disconnect the bottom of the column. Screw carefully one storage syringe to the bottom side avoiding trapping of any air bubbles. 4. Stop the pump and disconnect the top column from the chromatograpghy system. 5. Fill the top cavity of column with 20%ethanol and screw the other storage syringe carefully avoiding any trapping of air bubbles. 6. Hold each syringe carefully with one hand and wrap the rubber band to the shoulder of syringe with other hand. Store the column at 4 C for future use. RELATED PRODUCTS Download our Sample Preparation and Protein Purification Handbooks. Page 6 of 8

http://info2.gbiosciences.com/complete protein purification handbook For other related products, visit our website at www.gbiosciences.com or contact us. Page 7 of 8

www.gbiosciences.com Page 8 of 8