Bright Light, No Lysis

Similar documents
Bright Light, No Lysis

ViviRen Live Cell Substrate

Renilla-Glo Luciferase Assay System INSTRUCTIONS FOR USE OF PRODUCTS E2710, E2720, AND E2750.

Chroma-Glo Luciferase Assay System

Rapid Luciferase Reporter Assay Systems for High Throughput Studies

Luciferase Reporter Assay Kit III (Firefly & Renilla Single-tube Assay)

Dual-Glo Luciferase Assay System INSTRUCTIONS FOR USE OF PRODUCTS E2920, E2940 AND E2980.

Validation and Comparison of Single-Step Flash and Dual-Spectral Luciferase Reporter Gene Assays using the Synergy Line of Microplate Readers

GENE EXPRESSION AND EXPERIMENTAL READOUTS ON THE TURNER BIOSYSTEMS FAMILY OF INSTRUMENTS

Dual-Glo Luciferase Assay System Instructions for use of Products E2920, E2940 and E2980.

TECHNICAL MANUAL. HDAC-Glo 2 Assay. Instructions for Use of Product G9590. Revised 11/17 TM406

How To Choose a GeneCopoeia Luciferase System. Ed Davis, Ph.D.

ONE-Glo + Tox Luciferase Reporter and Cell Viability Assay

Gaussia Luciferase Assay reagent (GAR 2B)

CELL HEALTH. reliable cell viability data. instant time savings. PrestoBlue Cell Viability Reagent

RealTime-Glo MT Cell Viability Assay

HDAC-Glo I/II Assay and Screening System

GloResponse NF-ĸB-RE-luc2P HEK293 Cell Line

Tips & Techniques. Carl Strayer, Ph.D. October 11, , Promega Corporation. All rights reserved.

Optimizing Dual-Glo Luciferase Assays with the Synergy HT Multi-Detection Microplate Reader

ViaFect Transfection Reagent

Renilla Luciferase Receptor Gene Assay Kit

ToxiLight BioAssay Kit

GloResponse NF-ĸB-RE-luc2P HEK293 Cell Line

TECHNICAL MANUAL. GloSensor camp Assay. Instructions for Use of Products E1171, E1290, E1291 and E2301. Revised 1/19 TM076

TECHNICAL MANUAL. NADP/NADPH-Glo Assay. Instructions for Use of Products G9081 and G9082. Revised 8/17 TM400

TECHNICAL MANUAL. NAD/NADH-Glo Assay. Instructions for Use of Products G9071 and G9072. Revised 8/17 TM399

LDH-Glo Cytotoxicity Assay Instructions for use of Products J2380 AND J2381

SpectraMax DuoLuc Reporter Assay Kit

Firefly Luciferase Assay Kit

ToxiLight bioassay kit

Dual-Luciferase Reporter 1000 Assay System

Pre-made Lentiviral Expression Particles for Luciferase (firefly, Gaussia, Renilla and Cypridina)

Renilla Luciferase Assay Kit. Catalog Number: (150 assays) (1000 assays)

Calpain-Glo Protease Assay

Data Sheet. Application Monitor glucocorticoid signaling pathway activity. Screen activators or inhibitors of the glucocorticoid signaling pathway.

ApoTox-Glo Triplex Assay

Data Sheet. CRE/CREB Reporter Assay Kit (camp/pka Cell Signaling Pathway) Catalog #: 60611

Pgp-Glo Assay Systems

Renilla Luciferase Luminometric Assay Kit

Dual-Luciferase Reporter Assay System

Ultra-High Sensitivity Luminescence Reporter Gene Assay System

CytoTox-Fluor Cytotoxicity Assay INSTRUCTIONS FOR USE OF PRODUCTS G9260, G9261 AND G9262.

CytoTox-Glo Cytotoxicity Assay

Secrete-Pair Dual Luminescence Assay Kit. Secrete-Pair Gaussia Luciferase Assay Kit. User Manual

NanoBRET Target Engagement Intracellular BET BRD Assay

The Challenge The existing assay was based upon the ability of the client s therapeutic molecule to support the growth/ proliferation of a responder c

MULTITOX-FLUOR MULTIPLEX CYTOTOXICITY ASSAY TECHNOLOGY

RubyGlow TM Luminescent Cell Proliferation Assay Kit RubyGlow TM Luminescent Cell Viability Assay Kit RubyGlow TM Luminescent Cytotoxicity Assay Kit

High Sensitivity Luminescence Reporter Gene Assay System

Cignal Reporter Assay Handbook

ATP Luminometric Assay Kit

TECHNICAL BULLETIN. UGT-Glo Assay. Instruc ons for Use of Products V2120, V2121, V2130, V2131, V2081 AND V2082. Revised 4/15 TB551

Secrete-Pair TM Dual Luminescence Assay Kit For parallel bioluminescence assays of Gaussia luciferase (GLuc) and secreted Alkaline Phosphatase (SEAP)

Luciferase Assay Kit INSTRUCTION MANUAL. Catalog # Revision B.0. For Research Use Only. Not for use in diagnostic procedures.

BioLux Cypridina Luciferase Assay Kit

CellTiter-Glo 2.0 Assay

Data Sheet. SBE Reporter Kit (TGFβ/SMAD signaling pathway) Catalog #: 60654

Data Sheet. MAPK/ERK Signaling Pathway SRE Reporter HEK293 Cell Line Catalog #: 60406

The Transfection Collection TCF/LEF Transient Pack Wnt / -catenin Signaling Pathway Catalog #: 79273

Luc-Pair Duo-Luciferase Assay Kit 2.0

CellTiter-Glo Luminescent Cell Viability Assay INSTRUCTIONS FOR USE OF PRODUCTS G7570, G7571, G7572 AND G7573.

Luc-Pair Renilla Luciferase HS Assay Kit

ATP Assay Kit. Catalog Number KA assays Version: 04. Intended for research use only.

Data Sheet PD-1 / NFAT - Reporter - Jurkat Recombinant Cell Line Catalog #: 60535

Data Sheet CD137/NF-κB Reporter - HEK293 Recombinant Cell Line Catalog # 79289

Cell Viability and Senescence Detection Kits

CellTox Green Cytotoxicity Assay

HALOLINK RESIN FOR PROTEIN PULL-DOWN AND ANALYSIS

QuantiFluor dsdna System

ViaFect Transfection Reagent

Cell Proliferation Assays: Improved Homogeneous Methods Used to Measure the Number of Cells in Culture

CytoTox-Glo Cytotoxicity Assay All technical literature is available on the Internet at: Please visit the web site to verify that

Data Sheet. Hedgehog Signaling Pathway Gli Reporter NIH3T3 Cell Line Catalog #: 60409

Tropix Chemiluminescent Kits and Reagents For Cell Biology Applications

Assay ID Assay name Description Components of the assay SYS-A115 DRD5/ARRB2 targetscreener

NanoBRET BRPF1/Histone H4 Interaction Assay

Assays for drug discovery and research

Data Sheet GITR / NF-ĸB-Luciferase Reporter (Luc) - Jurkat Cell Line Catalog #60546

Data Sheet. Glucocorticoid Receptor Pathway GAL4 Reporter (Luc)-HEK293 cell Line Catalog #: w70666

Top and Bottom Measurements of Intracellular NanoBRET with the VICTOR Nivo

CellTiter-Glo Luminescent Cell Viability Assay INSTRUCTIONS FOR USE OF PRODUCTS G7570, G7571, G7572 AND G7573.

HO 1. Description Genetic reporters are used commonly in cell biology to study gene expression and other cellular events coupled to gene expression, s

GloResponse NFAT-RE-luc2P HEK293 Cell Line

Data Sheet. Glucocorticoid Receptor Pathway GR-GAL4 Reporter (Luc)-HEK293 cell Line Catalog #: 60655

Supporting Information for. Novel caged luciferin derivatives can prolong bioluminescence. imaging in vitro and in vivo.

Data Sheet HVEM/NF-κB Reporter Jurkat Recombinant Cell Line Catalog # 79310

Data Sheet. camp/pka Signaling Pathway CRE/CREB Reporter (Luc) HEK293 Cell Line Catalog #: 60515

detect and identify Junior LB 9509 The portable tube luminometer

Application Note AN001

CRE/CREB Reporter Assay Kit camp/pka Cell Signaling Pathway Catalog #: 60611

NanoBRET Target Engagement Intracellular Kinase Assay, K-5

Luciferase Assay System

Assay ID Assay name Description Components of the assay SYS-A124 ADRB2/ARRB2 targetscreener

The Synergy 2, A Novel Approach to Microplate Multi- Detection for HTS and Drug Discovery

Data Sheet. TCF/LEF Reporter Kit Wnt / -catenin signaling pathway Catalog #: 60500

NanoBRET Target Engagement Intracellular Kinase Assay, K-4

P45-Glo Assays All technical literature is available on the Internet at: Please visit the web site to verify that you are using t

DPPIV-Glo Protease Assay

Automated Caspase-Glo Assays Protocol

Transcription:

Bright Light, o Lysis Measuring Renilla Luciferase Luminescence in Living Cells By Erika Hawkins 1, M.S., James Unch 2, Ph.D., ancy Murphy 1, B.S., Jolanta Vidugiriene 1, Ph.D., Mike Scurria 2, Dieter H. Klaubert 2, Ph.D., and Keith V. Wood 1, Ph.D., 1 Promega Corporation and 2 Promega Biosciences, Inc. Abstract The ViviRen and EnduRen Live Cell Substrates have been developed to make measuring Renilla luciferase from live cells simpler and more sensitive than was possible with the substrates coelenterazine and coelenterazine-h. ViviRen Substrate generates very bright luminescence, at least 3-fold brighter than coelenterazine, while EnduRen Substrate generates very stable luminescence, permitting multiple measurements over incubations of 24 hours or more. Both live cell substrates can be multiplexed with CellTiter-Glo Reagent to normalize for viable cell numbers. Alternatively, the Chroma-Luc red Luciferase can be used to normalize for viable cell number or transfection efficiency. Researchers strive to monitor cellular activities with as little impact on the cell as possible. However, complete disruption of the cells is required for most cellular reporters to achieve accurate and reliable measurements. Introduction Researchers strive to monitor cellular activities with as little impact on the cell as possible. However, complete disruption of the cells is required for most cellular reporters to achieve accurate and reliable measurements. Renilla luciferase is a notable exception because its substrates, oxygen and coelenterazine, are nontoxic and readily permeable to cellular membranes. Unfortunately, coelenterazine is unstable in aqueous solutions and has been difficult and inconvenient to use under normal cell culture conditions. EnduRen and ViviRen Live Cell Substrates (a,b,c) have been designed to overcome this difficulty and, moreover, can be multiplexed with other luminescence assays to determine viable cell number. Stabilizing the Live Cell Substrates The EnduRen and ViviRen Live Cell Substrates are based on the core structure of coelenterazine-h, an efficient structural analog of coelenterazine commonly used in luminescent cellular assays. Historically, coelenterazinebased compounds have been difficult to work with because they are unstable in the aqueous environment used to maintain live cells. For example, coelenterazine-h in cell culture medium containing % fetal bovine serum (FBS) at 37 C, decreases in concentration by 5% in approximately 25 minutes. Coelenterazine concentration decreases even more quickly in this environment, dropping 5% in approximately 17 minutes (1). Autooxidation is one means by which this loss in coelenterazine and coelenterazine-h concentration occurs. Auto-oxidation presents a double problem in that it also generates background luminescence, thus decreasing assay sensitivity. The EnduRen and ViviRen Live Cell Substrates were designed so that the site of oxidation is protected by esters or oxymethyl ethers. The protecting groups serve to increase the half-life of the live cell substrates in culture medium to 5 11 hours compared to the 17- to 25-minute half-life for the unprotected coelenterazine substrates (1 3). Upon entry into viable cells, esterases and lipases cleave the protecting group from the live cell substrates, generating coelenterazine-h for use by intracellular Renilla luciferase (Figure 1). The low concentration of free coelenterazine-h in the culture medium results in a - to -fold decrease in autoluminescent background and thus an increased luminescent signal-to-background ratio (Figure 2, Panels A and B). Differences in the Live Cell Substrates ViviRen and EnduRen Live Cell Substrates both support Renilla bioluminescence, but the characteristics of the resulting luminescent signals are very different. The ViviRen Substrate generates a very bright but short-lived luminescent signal. In the example shown (Figure 2, Panel C), the maximum intensity of the ViviRen Substrate was approximately 3-fold brighter than coelenterazine. The much reduced autoluminescence from the ViviRen Substrate resulted in a signal-tobackground ratio that was 288-fold higher than that of coelenterazine. Low autoluminescence is a key feature of both the ViviRen and EnduRen Substrates. Whereas ViviRen Substrate generates bright luminescence, EnduRen Substrate generates longlasting luminescence. Esterases cleave the oxymethyl ether moiety from the EnduRen Substrate more slowly than they cleave the ester group of the ViviRen Substrate (structures in Figure 1, esterase data not shown). The lower concentration of coelenterazine-h results in a lower intensity but more stable luminescent signal. The luminescent signal generated by the EnduRen Substrate is thus stable for up to 24 hours.

A. Intracellular esterase EnduRen Live Cell Substrate H H Luciferase (Renilla, Aequorea, belia, Gaussia) H Coelenterazine-h H B. Coelenteramide-h H 2 EnduRen Live Cell Substrate H 2 ViviRen Live Cell Substrate Figure 1. Structural features of the Live Cell Substrates. Panel A. EnduRen Live Cell Substrate is converted inside cells to coelenterazine-h, a substrate of Renilla luciferase. A similar conversion occurs with ViviRen Live cell Substrate changing to coelenterazine-h (not shown). Panel B. Structures for EnduRen and ViviRen Live Cell Substrates. 4945MA In typical measurements, the initial luminescent signal generated by the ViviRen Substrate was at least 2 times brighter than the EnduRen Substrate, but after approximately 45 minutes the EnduRen Substrate signal was as bright as the ViviRen Substrate signal (Figure 3). The exceptionally stable luminescent signal generated by the EnduRen Substrate permits many measurements to be made from a single sample. For example, a single addition of EnduRen Substrate permitted sequential measurements of the inhibition of Renilla luciferase stably expressed in CH cells for more than 33 hours after transfection of sira for Renilla luciferase (Figure 4). We have demonstrated that the recommended concentrations and exposure times for the ViviRen and EnduRen Live Cell Substrates were not toxic to CH, HeLa, HEK 293 or IH/3T3 cell lines when compared to samples exposed to coelenterazine, to carrier or to no treatment (2,3). Multiplex Live Cell Substrates with Cell Viability Assays The assay for Renilla bioluminescence in living cells can be multiplexed with cell viability assays, allowing reporter activity to be normalized to the number of viable cells. This can be done most easily by using the CellTiter-Glo Reagent, which determines viable cell number by assaying for total ATP. Another normalization method uses co-transfection of a control plasmid that constitutively expresses a red-emitting luciferase, such as the Chroma-Luc Luciferase contained in the pcbr-basic Vector (Cat.# E1411) or pcbr-control Vector (Cat.# E1421). Multiplexing with CellTiter-Glo Reagent involves two reagent additions into the same sample. First Renilla luciferase is quantitated from the living cells following addition of the EnduRen or ViviRen Substrate. Second, CellTiter-Glo Reagent is added to the samples, lysing the cells to generate an ATP-dependent firefly luciferase signal. The CellTiter-Glo Reagent effectively Promega otes www.promega.com umber 9, 5/5 11

Measuring Renilla Luciferase...continued A. B.,, 1, 1.1.1 1 1, [Coelenterazine] (µm),, 1, 1 Luminescence Autoluminescence.1.1 1 1, [ViviRen Substrate] (µm) C. Signal-to-Background Ratio 3 25 2 15 5 Coelenterazine ViviRen Substrate.1 1 1, [Substrate] (µm) Figure 2. Sensitivity of in situ measurement of luminescence increases dramatically in the absence of autoluminescence. Luminescence was measured from CH cells stably expressing Renilla luciferase luminescence. Similarly, autoluminescence was measured from nontransfected CH cells. Coelenterazine (Panel A) or ViviRen Substrate (Panel B) was titrated into wells containing CH cells in F12 media with % FBS. Luminescence or autoluminescence was measured with a Turner BioSystems Veritas Luminometer approximately 2 minutes after addition of coelenterazine or ViviRen Substrate (n = 6). Signal-to-background ratios (luminescence minus autoluminescence divided by autoluminescence) were calculated from the data in Panels A and B and are presented in Panel C. 4811MA 12,, 1, ViviRen Substrate EnduRen Substrate 2 3 4 5 6 Time (minutes) Figure 3. Maximal luminescence intensity generated by ViviRen Substrate is ~2-fold higher than that of EnduRen Substrate, but they converge approximately 45 minutes after substrate addition. CH cells stably expressing Renilla luciferase were exposed to ViviRen or EnduRen Substrate at 6µM, and luminescence was measured at intervals of approximately 2 minutes for 1 hour with the Turner BioSystems Veritas Luminometer (n = 6). After approximately 45 minutes, the luminescence intensities from the two sample sets were similar. 48MA eliminates the Renilla luciferase signal and any enzymeindependent luminescence that may be generated by the residual coelenterazine-h in the sample reaction. Using the most extreme case as an example, the luminescent and autoluminescent signals generated by 2 12 moles of purified Renilla luciferase (over 1, times more enzyme than most cellular preparations) exposed to 6µM coelenterazine-h was quenched by 7,-fold ±,9-fold after adding CellTiter-Glo Reagent. The residual luminescence was only 56% ± 4.7% of the luminescence generated by CellTiter-Glo Reagent and DMEM medium + % serum (in the absence of cells), and so below the level of luminescence generated by cells in this environment. Multiplexing Live Cell Substrates with an in situ beetle luciferase measurement requires the use of a luminometer with wavelength-discriminating filters. The red Chroma- Luc Luciferase generates luminescence with maximal intensity at 611nm, while the Renilla luciferase generates maximal intensity at 488nm (Figure 5A). This large spectral difference permits the two signals to be measured from the same sample using the appropriate red and blue filters.

Renilla luminescence (% of nonspecific nucleotide sira) 12 8 6 4 2 5nM sira 25nM sira 5 15 2 25 3 35 4 A. Relative Intensity (% of maximum) 12 8 6 4 2 4 Renilla pcbr-control Vector 45 5 55 6 65 7 Wavelength (nm) Time (hours post transfection) Figure 4. EnduRen Substrate permits repetitive measurement of Renilla luminescence from live cells, monitoring RAi over time in the same cell population. Decreasing luminescence can be measured from live cells to monitor the effect of sira on Renilla luciferase expression in CH cells stably expressing Renilla luciferase. Cells were transfected with 5nM or 25nM sira against a nonspecific negative sequence or against a Renilla luciferase target sequence. Renilla luciferase activity was measured at indicated time points. The data were normalized as percent of Renilla luciferase activity in cells transfected with specific targeting sequence compared to a nonspecific control. The results are the average of 12 wells. The ability to multiplex was demonstrated in an experiment where Renilla luciferase expression was controlled with the responsive CRE element as promoter and red Chroma-Luc Luciferase expression was controlled with a constitutive SV4 promoter. The addition of EnduRen Substrate and beetle luciferin to the cells allowed measurement of the cells CRE response, while normalizing for viable cell number (Figure 5). As expected, normalizing to an internal control reduced the relative error within the experimental data. As Figure 5B shows, the relative error of the calculated induction decreased from 43% to 24% when the Renilla luminescence was normalized to the red Chroma-Luc luminescence in the same well. Conclusion The Renilla luciferase reporter system requires only oxygen and coelenterazine substrates to generate luminescence. For an in situ Renilla reporter gene assay, providing coelenterazine is all that is necessary to generate light in living cells. However, the instability of coelenterazine in aqueous culture medium previously limited the sensitivity and utility of this approach. The chemically protected EnduRen and ViviRen Live Cell Substrates have overcome stability problems, enabling consistent and sensitive measurement of Renilla luminescence in real time, in a convenient format. 4946MA B. Signal Induction 4 3 2 Renilla luciferase ormalized luminescence 1 2 3 4 5 6 7 Time (hours after isoproterenol & R addition) Figure 5. Spectra and luminescence measurements generated by Renilla luciferase and red Chroma-Luc Luciferase. Panel A. Spectra were measured from purified Renilla luciferase and red Chroma-Luc Luciferase lysate from CH cells stably transfected with the pcbr-control Vector (Cat.# E1421). Spectra were captured using a scanning spectrophotometer configured to collect emission data. The shaded areas represent the maximal transmittance range of the two filters used: a 5/6nm filter and a 6 longpass filter. Panel B. Renilla luciferase and red Chroma-Luc Luciferase luminescence were monitored from HEK 293 cells over 6 hours. Cells were transiently transfected in a 96-well plate with 2 vectors containing: i) the Renilla luciferase gene with PEST and CL1 destabilization sequences under control of the CRE promoter, and ii) the pcbr-control Vector (Cat.# E1421) containing red Chroma-Luc Luciferase under the control of the SV4 promoter. Approximately 24 hours post-transfection, cells were exposed to 6µM EnduRen Substrate and 2mM beetle luciferin. After 2 hours, cells were treated with 1µM isoproterenol and µm R-2-1724 (both Calbiochem, La Jolla, CA). Luminescence was measured periodically for 6 hours using the Turner BioSystems Veritas Microplate Luminometer (Cat.# E651). For each measurement, Renilla luminescence was quantitated using the blue filter (5/6) and the red Chroma-Luc luminescence was measured using the red filter (6 longpass). Total signal for each color luminescence was calculated (using the spreadsheet tool at: www.promega.com/techserv/tools/ select the Chromma-Luc Calculator ) then induction was calculated as the average induced luminescence divided by the average noninduced luminescence (normalized or not normalized to the red luminescence). For each data point, n = 12 and standard deviation is shown. 4947MA Promega otes www.promega.com umber 9, 5/5 13

Measuring Renilla Luciferase...continued References 1. Hawkins, E.M. et al. (22) In: Bioluminescence & Chemiluminescence Progress & Current Applications. Stanley, P.E., and Kricka, L.J., eds. World Scientific, Singapore, 149. 2. EnduRen Live Cell Substrate Technical Manual, #TM244, Promega 3. ViviRen Live Cell Substrate Technical Manual, #TM64, Promega Protocols EnduRen Live Cell Substrate Technical Manual, #TM244, Promega (www.promega.com/tbs/tm244/tm244.html) ViviRen Live Cell Substrate Technical Manual, #TM64, Promega (www.promega.com/tbs/tm64/tm64.html) CellTiter-Glo Luminescent Cell Viability Assay Technical Bulletin, #TB288, Promega (www.promega.com/tbs/tb288/tb288.html) Chroma-Luc Series Reporter Vectors Technical Manual, #TM59, Promega (www.promega.com/tbs/tm59/tm59.html) Chroma-Glo Luciferase Assay System Technical Manual, #TM62, Promega (www.promega.com/tbs/tm62/tm62.html) Erika Hawkins, M.S. Jolanta Vidugiriene, Ph.D. James Unch, Ph.D. Mike Scurria ancy Murphy, B.S. Dieter Klaubert, Ph.D. rdering Information Product Size Cat.# EnduRen Live Cell Substrate.34mg E6481 3.4mg E6482 34mg E6485 ViviRen Live Cell Substrate.37mg E6491 3.7mg E6492 37mg E6495 CellTiter-Glo Luminescent Cell Viability Assay ml G7573 ml G7572 ml G7571 Keith Wood, Ph.D. Research Fellow Red Chroma-Luc Vectors Product Size Cat.# pcbr-basic Vector 2µg E1411 pcbr-control Vector 2µg E1421 (a) Patent Pending. (b) Certain applications of this product may require licenses from others. (c) This product does not convey a license to use recombinant Renilla luciferase under U.S. Pat. os. 5,292,658, 5,418,155 and related patents. Promega sells licensed Renilla luciferase vectors, which may be used in conjunction with this product. Products may be covered by pending or issued patents or may have certain limitations. Please visit our Web site for more information. CellTiter-Glo is a registered trademark of Promega Chroma-Glo, Chroma-Luc, EnduRen and ViviRen are trademarks of Promega Veritas is a trademark of Turner BioSystems, Inc. 14