Connection box SCB-133

Similar documents
Protective Capony RTC-16

No part of this manual may be reproduced in any form or by any means, without prior written permission of Darrera.

Table of contents. 1. Introduction

ENGLISH Compact Half Coupler 50 mm, SWL: 50 kg

GENERAL GUARANTEE CONDITIONS OF POLTRONIC S.A. (SUPPLIER) FOR A COMMERCIAL PARTNER (PARTNER) FOR NEXTEC BRAND PRODUCTS

ul. Toruńska Gliwice, Poland

Global Water Instrumentation, Inc.

J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL

TRAPEZOIDAL SHEET METAL RAIL LIFT/VARIO for trapezoidal sheet metal roofs

Recommended Land Pattern: [mm] Dimensions: [mm] Article Properties: USB 2.0 Type A Horizontal SMT Short Type WR-COM

MODEL CA-72 SERIES ACCELERATION TRANSDUCER INSTRUCTION MANUAL

USER S MANUAL release 1.0

Dimensions: [mm] Recommended Hole Pattern: [mm] Pattern Properties: Article Properties: WR-MM Male Connector with Polarization

MD Power Supply -48Vdc +Bias Tee

INSTALLATION & OPERATION INSTRUCTIONS ICW-3 WINDOW INTERCOM

Dimensions: [mm] Recommended Land Pattern: [mm] 3,5 pl 3,5 1,0 0,6. Pattern Properties: Article Properties:

TL-600 MOBILE PHASE HEATER

Dimensions: [mm] Recommended Land Pattern: [mm] Pattern Properties: Article Properties: 0.50mm SMT ZIF Horizontal Hinge Type Bottom Contact WR-FPC

CREATIVE PRODUCTS WARRANTY RETURN POLICY

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

Dimensions: [mm] Recommended Land Pattern: [mm] Pattern Properties: Article Properties: 0.50mm SMT ZIF Horizontal Top Contact WR-FPC

Dimensions: [mm] Recommended Land Pattern: [mm] Pattern Properties: Article Properties: 0.50mm SMT ZIF Horizontal Bottom Contact WR-FPC

Recommended Land Pattern: [mm] Dimensions: [mm] Pattern Properties: Article Properties: 0.50mm SMT ZIF Vertical Type A WR-FPC

Power Distribution Module Replacement Instructions

DJ Switch 10F V2 ORDERCODE 50365

GENERAL TECHNICAL TERMS OF KÖNIG KFT

Recommended Land Pattern: [mm] Dimensions: [mm] Pattern Properties: Article Properties: WR-FPC SMT ZIF Horizontal Low Profile Top Contact, 1.

FO-6000 Inline FO Filter Holder FO-6000FILT INSTRUCTION MANUAL. Serial No. World Precision Instruments

Recommended Land Pattern: [mm] Dimensions: [mm] Pattern Properties: Article Properties: WR-FPC SMT ZIF Horizontal Back Locking Dual Contact, 0.

Dimensions: [mm] Recommended Land Pattern: [mm] Pattern Properties: Article Properties: WR-FPC SMT ZIF Horizontal Bottom Contact, 0.

RJE INTERNATIONAL, INC. U LB-364EL R EV 3.2

USER S MANUAL release 2.0

RJE INTERNATIONAL, INC.

Recommended Land Pattern: [mm] Dimensions: [mm] Pattern Properties: Article Properties:

Recommended Land Pattern: [mm] Dimensions: [mm] Pattern Properties: Article Properties:

MANUAL. ENGLISH Antenna Booster Ordercode: D1425. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Installation & User Manual

USER S MANUAL release 2.0

Contents CONTACT INFORMATION... 2

Claims & Returns Guidelines Sirona Dental Systems GmbH (Status September 2018)

L505 VISUAL LEVEL INDICATOR. Dip-Tape Visual Level Indicator INSTALLATION AND OPERATIONS MANUAL

Dimensions: [mm] Recommended Land Pattern: [mm] Pattern Properties: Article Properties: Serie mm Screwless SMT - WR-TBL

Recommended Land Pattern: [mm]

INSTALLATION AND OPERATION MANUAL Mechanical Road Blocker of TYRE-KILLER series (surface-mount/submersible)

FLARING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

TR1 TR2. Transformer / Relay Adapter. Installation Manual. Rev 1.1 Feb. 22, Deklin Technologies Inc 413 Childe Harolds Lane Brentwood, TN 37027

Adjustable Fused Power Supply

Professional Weighing Equipment. K-Series Scales. Operation Manual KHR 6000 KHR 123 KHR 502 KHR 3001

WE-CNSW HF SMD Common Mode Line Filter (High Frequency)

WE-CNSW HF SMD Common Mode Line Filter (High Frequency)

Operation Manual. Professional Weighing Equipment. MRB Series Mid Resolution Balances. MRB 500g MRB 1200g MRB 2500g MRB 6000g MRB 10000g

P1902 Installation Manual

Bedhead Service Systems. Instructions for Use. July 2016 ASF-18 (0)

THE KENYA POWER AND LIGHTING CO. LTD

Contents. 1. About this edition of user instructions

WE-CNSW SMD Common Mode Line Filter

Recommended Land Pattern: [mm]

Recommended Land Pattern: [mm]

POWER TRANSFORMER INSTALLATION

Effective This guide supersedes all previous versions

Thrane & Thrane TT-3026L/M easytrack Getting Started

Created by EBCCW 00:06. X65 Locating module. User Documentation

Temporary Wiring. Low-Voltage Electrical Safety Orders

Recommended Land Pattern: [mm]

Recommended Land Pattern: [mm]

Recommended Land Pattern: [mm]

Recommended Land Pattern: [mm]

Recommended Land Pattern: [mm]

Recommended Land Pattern: [mm]

INSTRUCTION MANUAL Wardrobe lift 717

OPERATION MANUAL. A220 Arc Welding Machine. Serial Number: Where Purchase: Date of purchased:

1. About this edition of the operating manual

Regal Pipettes INSTRUCTION MANUAL. Serial No. World Precision Instruments

INSTALLATION PROCEDURE

TRS100 Rapid Assay System Pre-Installation Guide

LoadLift. Operating and Maintenance Instructions. Station Road Clowne Chesterfield Derbyshire S43 4AB Tel: Fax:

Dimensions: [mm] Recommended Hole Pattern: [mm] Schematic: N. Dimensions: WS-DITV Small Compact THT Dip Switch

Recommended Land Pattern: [mm]

Recommended Land Pattern: [mm]

Single Core, Aluminum Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Recommended Land Pattern: [mm]

User Manual Agreto Heavy Duty Modules 5t/10t/15t

CHECK LINE. Operating Instructions BY ELECTROMATIC STM-50

Recommended Hole Pattern: [mm]

SERVICE PEDESTAL FLOOR-MOUNTED SERVICE PEDESTAL. Installation Manual

Thermocouples. Operating and Maintenance Manual English. Thermocouples

INSTRUCTION MANUAL FOR WIRE WELDING MACHINE

WE-CNSW SMD Common Mode Line Filter

MPM-10 Piezo Translator INSTRUCTION MANUAL

TO-2013BC-MYE. Surface Mount Device LED. Features. Dimensions MOLDING BODY(LENS) 0.40 PCB 0.40 CATHODE MARK SOLDERING TERMINAL

Recommended Hole Pattern: [mm]

OLYMPUS PRODUCT SERVICE REPAIR FORM Ref:

Recommended Land Pattern: [mm]

Operating and Maintenance Instructions. Station Road Clowne Chesterfield Derbyshire S43 4AB Tel: Fax:

TO-1608BC-MYF. Surface Mount Device LED. Features. Dimensions MOLDING BODY(LENS) CATHODE MARK 0.25 SOLDERING TERMINAL DIE

DMX-BRANCH/4. user manual. ELATION DMX-BRANCH/4 user manual

Operation Manual. Professional Weighing Equipment. MRW SERIES intelligent weighing scale. WASHDOWN WEIGHING SCALE - Dust and Waterproof Scale IP65

Recommended Hole Pattern: [mm]

New Advanced Environmental Air Treatment System

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

Transcription:

Connection box SCB-133 Technical Documentation (133-1-19042013) St. Petersburg 2013 v.1.1

Table of Contents 1. GENERAL... 4 2. DELIVERY SET... 4 3. GENERAL ARRANGEMENT... 4 4. INSTALLATION AND CONNECTION... 5 5. TRANSPORTATION AND STORAGE... 11 6. RECYCLING... 12 7. WARRANTY... 13 8. DATE OF PACKING... 14 9. ACCEPTANCE DETAILS... 14 10. DATE OF COMMISSIONING... 14 Page 2

This Operating Manual applies to the SCB-133 Connection box. This Manual is intended to assist in the familiarization with the design, operating principles and procedures established for the convection heater during its intended use or maintenance. This Manual can also be used as a source of information about сведений об устройстве to draw up corresponding sections in the operational documentation for the equipment, в которой this product may be used as its component part. All information contained in this Manual is distributed by the company for information purposes only. The information is subject to changes without notification to consumers; the information may contain errors or discrepancies. The information provided may not contain obligations on the part of Unicont SPb Ltd Page 3

1. General The SCB-133 connection box is an equivalent for the TT-3616D (SAILOR) connection box. This connection box is used with the Inmarsat mini-с SAILOR ship earth stations (SES), type TT-3026xx (TT-3026M, TT-3026S, TT-3026D, TT-3026L, TT-3000SSA, etc.). 2. Delivery set 1. SCB-133 connection box 1 2. Earthing cable 1 3. Set of cable fasteners 1 4. Operating manual 1 3. General arrangement The SCB-133 considerably simplifies the mounting process of the SES components (transceiver, antenna cable and alert buttons) and additional devices (power supply unit, shipboard computer, etc.). 10.5 32 V supply Data terminal Alert buttons Test button Fig. 1. Connection of the SES using the SCB-133 Page 4

4. Installation and connection 4.1 Installation The connection box is installed on a vertical bulkhead or mounting panel. The SCB- 133 should be installed at a maximum distance of 50 meters from the transceiver. Recommended installation clearances are shown on the figure below (Fig. 2). 50 mm 50 * 50 mm мм. * 50 50 мм. mm ** Minimum 100 mm * Свободное пространство для * Clearances for easier installation облегчения монтажа ** Свободное ** Clearances пространство for cable для подсоединения connections кабелей Fig. 2. Recommended installation clearances for the SCB-133 4 holes Fig. 3. SCB-133 connection box. Dimensional drawing Page 5

4.2 Connections Using a special tool supplied with the set of fasteners will make the connection of leads much easier. Caution! Do not apply excessive pressure on the tool to prevent damages of the connection box. Fig. 4. Tool The connection box includes a PCB with the following components: - clamp-type terminals to connect leads of (up to 2.5 mm in diameter) of the power supply unit, buttons and transceiver; - DB-9F connector to connect the onboard computer (e.g., the DT-310 data terminal). Connecting the earthing lead The connection box includes the earthing lead, 1 m long. One end of the lead is fixed to the metal base of the connection box (see Fig. 5), and the other end is connected to the ship s metal structure. Do not use larger lengths of the earthing lead since it will result in degradation of the magnetic field protection. Fig. 5. Connecting the earthing lead to the SCB-133 Page 6

Power supply connection To connect the power supply cable, fix its shield to the connection box using a metal plank. The positive lead is attached to the DC+ terminal; the negative lead is connected to the DC- terminal (see Fig. 6). When the connections are made correctly, the red LED in the top part of the PCB to the right of the J1 terminal will light up after the voltage is supplied to the unit. Fig. 6. Connecting the power lead Connecting the TT-3026xx to the SCB-133 To connect the transceiver to the connection box, follow the below procedures: 1. Strip the cable insulation at a distance of 200 mm (see Fig. 7). 2. Wrap the cable shield around the cable insulation as shown on the below figure (Fig. 8). 3. Fix the cable using a metal plank of the connection box (see Fig. 9). 4. Connect the transceiver cable following the color markings on the PCB (see Fig. 10). Fig. 7. Preparing the transceiver cable Page 7

Fig. 8. Preparing the transceiver cable shield Fig. 9. Fixing the transceiver cable Fig. 10. Example of the transceiver cable connection Page 8

Connecting the buttons The red alert button (3-lead) is included in the delivery set of the station. When 2 or more alert buttons are required, additional buttons (4-lead) can be installed. To make the installation process of the alert buttons easier, you can use color code templates to connect 2, 3 or 4 buttons. An example of these templates is shown on the figure below (Fig. 11); the template originals in full scale of the terminal contacts are given in the documentation supplied with the station. Copy the required template on a sheet of paper; cut and put it on the installation place as shown on the figure (Fig. 12). Fig. 11. Color code templates These templates are given in the original documents provided by the station manufacturer, i.e. Thrane & Thrane (doc No. 98-120343 ver.g, release date 13.05.2009). To prevent incorrect connection of the equipment, please read carefully the documentation for your station and make sure that no changes have been made. Fig. 12. Using a template for 2 alert buttons Page 9

An example of connecting the connection box with cables is shown on the figure below (Fig. 13). To make sure that the cables and buttons are connected correctly, check the performance of the entire system (refer to the description of the connected station). Fig. 13. Connecting the cables of the connection box with 2 alert buttons Page 10

5. Transportation and Storage The divice shall be stored in heated space at air temperature of +5 ºС to +35 ºС (maximum values of -55 ºС to +70 ºС), at relative humidity of air not exceeding 95 % at temperature of +25 C and content of dust, oil, moisture and aggressive admixtures in the air not exceeding the norms envisaged by GOST 12.1.005-88 for the working zone of production areas. The device shall be transported in transport container of the manufacturer in closed transport. Means of transport: automobile and railway closed transport (covered wagons, universal containers) by air (in pressurized and heated bays of airplane) by sea (in dry service spaces). The device shall be transported in accordance with the transport regulations in force for the particular transport. During handling operations and transportations strictly observe the requirements of handling marks on boxes and do not allow bumps and impacts which can affect preservation and serviceability of the device. Packed devices shall be reliably secured in vehicles. After storage in stores or transportation at temperature below +10 ºС the devices shall be unpacked only in heated spaces after keeping them unpacked in under normal climatic conditions for12 hours. Page 11

6. Recycling Do not recycle the packing of a new product, its parts with defects identified during its operation as well as the overage product as common household waste since they contain materials and raw materials suitable for their recovery. Decommissioned and unused components should be delivered to a specialized waste collection center licensed by local authorities. You can also send the overage equipment to the manufacturer for its further recycling. Proper recycling of the product components will prevent potential negative consequences for human health and the environment, as well as provide recovery of the product component materials while substantially saving on energy and resources. The product does not endanger human life and health or the environment during and after its service life. This product should be recycled following the requirements applicable to electronic equipment. Products marked with a crossed-out recycle bin should be recycled apart from common household waste. Page 12

7. Warranty The manufacturer guarantees the unit SCB-133 complies with this manual provided that the operation, transportation and storage conditions are adhered to during the warranty period. The unit s warranty period expires 24 months from the date of its shipping from the manufacturer s storehouse. Within the warranty period, the owner is entitled for a free repair, or a replacement of a separate part, provided that the malfunction occurred through the manufacturer s fault. Warranty repair is provided if the unit is submitted with the manufacturer s label and a legible serial number available on it, as well as this operating manual. The manufacturer is not responsible and cannot guarantee the unit s operation: 1. After the warranty period is over; 2. In case of the failure to observe the unit s operation, transportation, storage and installation rules and conditions; 3. If the unit is in an unmarketable condition, or has a damaged body, and other causes beyond the manufacturer s control; 4. If self-made electrical devices were used. 5. If there was an attempt to repair the unit by a person who is not an authorized representative of the manufacturer. If the owner loses this operating manual or the manufacturer s label with a serial number, the manufacturer shall not provide their copies, and the owner shall be divested of the right for a free repair during the warranty period. Upon the warranty expiry, the manufacturer shall facilitate the repair of the unit at the owner s expense. Note: in case of warranty repair, the unit s disassembling from the installation site and its delivery to the manufacturer s service center are done at the owner s expense. find: Visit the manufacturer s website www.unicont.spb.ru (section support/warranty ) to forms to fill in claims, full warranty description; full description of the warranty service rendering procedure. The manufacturer service center s address and contact details: Unicont SPb, Ltd. Bld. 26Е Kibalchich Str., Saint Petersburg, 192174, Russia tel.: + 7 (812) 622 23 10, +7 (812) 622 23 11 fax: +7 (812) 362 76 36 e-mail: service@unicont.spb.ru Page 13

8. DATE OF PACKING Connection box SCB-133 name of article designation serial number Packed Unicont SPb Ltd., Russia. Manufacturer according to the requirements of the current technical documentation. post signature clarification of signature year, month, day 9. ACCEPTANCE DETAILS Connection box SCB-133 name of article designation serial number was manufactured and accepted in accordance with the regulatory requirements of the state standards and applicable technical documentation, and is suitable for operation. Quality control representative Stamp here signature clarification of signature year, month, day 10. DATE OF COMMISSIONING Connection box SCB-133 name of article designation serial number The unit has been put into operation. Date of installation: Place of installation: Person in charge of installation: Page 14