Determination of Sulphur Dioxide by Pulsed UV-Fluorescence

Similar documents
Fpollutant-free zero air for analytical

Stack Sampling. requires airflow through the sampling probe to be at the same rate as that flowing in the waste gas stream isokinetic

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

Air Quality Measurement Methods. Tim Morphy Regional Manager Thermo Electron October 20 th, 2006

Proceedings of the 43 rd Annual ISA Analysis Division Symposium

Laboratory-Scale Investigation of UV Treatment of Ammonia for. Livestock and Poultry Barn Exhaust Applications

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

3/4/2014. Air Pollution. Chapter 15 Air Pollution and Stratospheric Ozone Depletion. Major Air Pollutants. Primary Pollutants

// XPLORER-NS. Total Nitrogen and Sulfur Analyzer

A Survey of Laser Types. Gas Lasers

Application Note. Hydrogen Purity Analysis by FTIR PROBLEM BACKGROUND

Lab 6 Measurement of Ozone

RARE-EARTH DOPED PHOSPHATE GLASSES FOR NEODYMIUM LASER SYSTEMS POSSESSING A GREATLY ENHANCED PUMP POWER CONVERSION

Final Exam. Physical Constants and Conversion Factors. Equations

Continuous Mercury Monitoring at Cement Plant

Lab 7 Measurement of Ozone

Mercury Monitoring in a Cement Kiln

HORIBA Portable Emissions Measurement Systems (PEMS)

Promoting environmental protection by environmental monitoring

Chapter 15 Air Pollution and Stratospheric Ozone Depletion

Identify three common gaseous pollutants in air and state how each of these pollutants are produced.

Greenhouse Gas Measurement Technology

How to Build the World s Fastest Spectrofluorometer. MF 2 Multi-Frequency Fluorometer

In-situ monitoring of ammonia gas using an optical fibre based approach

Fluorescence spectroscopy

Suprasil and Infrasil Material Grades for the Infrared Spectrum

Fluorescence & UV- Visible Workshop

Title: Standard Operating Procedure for Measurement of Ozone in Ambient Air by Ultraviolet (UV) Photometry

Spectroscopy with UVC LEDs in Environmental Monitoring & Life Sciences

WELCOME TO PERIOD 12: CONSEQUENCES OF USING CHEMICAL ENERGY Homework #11 is due today.

TÜV RHEINLAND IMMISSIONSSCHUTZ UND ENERGIESYSTEME GMBH

Module 4 : Hydrogen gas. Lecture 29 : Hydrogen gas

APPLIED. OiW-100 Oil in Water Analyzer

Measurement of Equivalence Ratio Using Optical Flame Chemiluminescence Sensor of Turbulent Diffusion Flame

1. INTRODUCTION 2. EXPERIMENTAL 3. REFERENCES

Long-term field intercomparison of N 2 O observations with GC-ECD and Cavity Enhanced Absorption Spectroscopy at Jungfraujoch

ONLINE FLUE GAS ANALYZERS

High-precision MIR trace gas analysis for environmental applications

Air Pollution Types of air pollutants

Crystal Growth, Optical and Thermal Studies of 4-Nitroaniline 4- Aminobenzoic Acid: A Fluorescent Material

Guiding Questions. What is acid rain, how is it formed, and what are some of its impacts?

1. Monitoring and controlling urban pollution.

D DAVID PUBLISHING. Hydrogen Gas Purifiers for Fuel Cells. 1. Introduction. 2. Scientific Approach

High temperature in-situ IR laser absorption CO-sensor for combustion control

Assessing Heat Treatment Carburization via the Combustion Method

CO Sensor Response Study NO & NOx Analyzer Validation. June 6, 2018

ChE 505 Chapter 1N revised 01/17/13

Review of Vehicle Emission Measurement and Sampling System

Low-mass PM analyzer MEXA-1370PM Improvement of the Performance for PM Composition Analysis

Perkin Elmer HGA-600/ HGA-700 Graphite Furnaces

CHAPTER 5. ABSORPTION AND FLUORESCENCE OF CsI(Tl) AND. CsI(Tl)In CRYSTALS

GE 2211 Environmental Science and Engineering Unit III Air Pollution. M. Subramanian

PROCESS ANALYZER FOR CLEAN COAL APPLICATIONS

Plasmatron Fuel Reformer Development and Internal Combustion Engine Vehicle Applications*

Co-Combustion of Wood and Straw in a Circulating Fluidized Bed Boiler reduction of NO x emission

TruePeak TDLS200. NH 3 Slip Measurement. <Document Number> Copyright Yokogawa Electric Corporation <date/time>

Spectroscopy Solutions for Pharmaceuticals:

Building a Bigger, Better Zero Air Generator Certification Process

WSA-DC NEXT GENERATION TOPSØE WSA TECHNOLOGY FOR STRONGER SO 2 GASES AND VERY HIGH CONVERSION. Helge Rosenberg Haldor Topsoe

Proceedings of the 22 nd Annual International Pittsburgh Coal Conference Paper 5-1 Pittsburgh, PA September 12-15, 2005

CHAPTER 3 BENEFITS OF BETTER BURNING

UV-Visible Spectrophotometer Calibration. S.ZALI M.Sc. Dept. of Analytical chemistry Razi vaccine serum research institute

Fluorescence spectroscopy

THE COMBUSTION OF HYDROCARBONS. I love the smell of napalm in the morning smells like victory!

Time-resolved Measurements Using the Agilent Cary Eclipse Fluorescence Spectrophotometer A Versatile Instrument for Accurate Measurements

UV/Vis/NIR Certified Reference Materials

POLLUTION FROM MOTOR VEHICLES

SMS 100 MERCURY ANALYZER SMS 100. Mercury analysis directly on solid samples from the undisputed leader in Atomic Spectroscopy

4.4 CLIMATE CHANGE. Concentrations of gases in the atmosphere affect climates experiences at the Earth s surface

4/12. There is so much pollution in the air now that if it weren t for our lungs there d be no place to put it all. Robert Orben

Robust flue gas probes for industrial emissions measurements.

Proposed Guidelines for the Reduction of Nitrogen Oxide Emissions from Natural Gas fuelled Stationary Combustion Turbines

1) ABSORPTION The removal of one or more selected components from a gas mixture by absorption is probably the most important operation in the control

Particulate CEMs for Wet and Dry FGD applications. By William Averdieck, Managing Director, PCME Ltd, UK

CHAPTER 6 : GAS SAMPLING SYSTEMS

Road Tunnel Atmosphere Monitoring Systems TunnelCraft 3 - Air Quality Monitor Continuous measurement of NO2 and Visibility in road tunnels

Trace Moisture Contamination in Ultra-High Purity Phosphine: Techniques for Measurement and Control

Hydrogen Production via Biomethane Reforming in DBD Reactor

Contact Details. Dr Alexander Galkin. Office: MBC Room 186. Tel: (028) Frequency and wavelength.

Fluorescence spectroscopy

4-9 Chemistry/5-9 Trilogy Chemistry of the atmosphere

Information Centre Nitric Acid Plants. Kittiwake Procal Ltd Page 1 of 6

A novel method for NOx and Hg emission control in power plants using existing wet limestone scrubbers

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions

HOMOSIL, HERASIL 1, 2 and 3


METHOD 3 - GAS ANALYSIS FOR THE DETERMINATION OF DRY MOLECULAR WEIGHT. NOTE: This method does not include all of the

July Table 1. General influencing trends of carbon and sulfur on the physical properties ofmetals.

METHOD 7550 OSMIUM (ATOMIC ABSORPTION, DIRECT ASPIRATION)

TOWARDS THE UNIFYING OF THE DETECTION SYSTEMS FOR THE MEASUREMENT OF THE MAJOR GREENHOUSE GASES AND RELATED TRACERS

Analysis of Luminescence Properties of Phosphorescent Polyimides under Low Temperature and Vacuum Conditions

Supporting Information

Emission Monitoring Technologies for Combustion and Gasification Plant

After-treatment of emissions from heavy duty vehicles. Jonas Granestrand October 22 nd, 2013

Standard Optics Information

Feature Article. Improving the accuracy of Fuel Consumption Measurement in CVS system. Tatsuki KUMAGAI. Introduction

Boiler Efficiency Testing. To understand the operation of a fire tube boiler To determine the operating efficiency of the boiler

Gas Analyzer Spare Part Recommendations

PRODUCTS OF COMBUSTION

Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR)

Transcription:

Determination of Sulphur Dioxide by Pulsed UV-Fluorescence Abstract J. Mohn and L. Emmenegger Swiss Federal Laboratories for Materials Testing and Research (EMPA), Überlandstrasse 129, CH-86 Dübendorf Email: joachim.mohn@empa.ch; lukas.emmenegger@empa.ch We have investigated the cross-sensitivity of a commercially available SO 2 monitor (TEI 43 C-FG) with respect to the fluorescence of NO, CO and CO 2. Quenching of the NO and the SO 2 fluorescence by O 2 and CO 2 was also determined. The results were implemented in a set of equations and subsequently used to correct the monitor s output for possible interferences. For highly variable O 2 concentrations, quenching by molecular oxygen was controlled by dilution of the sample gas with synthetic air. The response of an UV-fluorescence monitor to various gases is largely determined by the light spectrum used for excitation and detection. Therefore, absorption spectra of the main components were measured. Furthermore, fluorescence spectra of SO 2 and NO were obtained as a function of the excitation wavelength. Based on these data, the advantages and limitations inherent to the selection of filters are discussed and further improvements suggested. 1. Introduction Sulphur dioxide (SO 2 ) is the most abundant anthropogenic sulphur compound in the troposphere, and is mainly emitted through coal and petroleum combustion, petroleum refining, and metal smelting operations. In Switzerland, SO 2 emissions were reduced by more than 75 % over the past twenty years. However, further improvements are necessary to meet international obligations and to avoid acidification of ecosystems. Therefore, continuing efforts on measurement and control of sulphur oxide emissions are needed [1]. Increasingly stringent emission limits for vehicle engines and industrial applications often require appropriate (catalytic) after-treatment systems. These systems are frequently sensitive to sulphur compounds. The precise determination of concentrations and reactions of sulphur oxides in (flue) gas treatments are therefore a novel application for sensitive SO 2 measurement techniques. This is e.g. illustrated by a study indicating oxidation and storage of sulphur oxides in a continuously regenerating trap (CRT)-system which is employed in diesel engines for the reduction of particulate matter emissions [2]. Commercial pulsed UV-fluorescence detectors offer an inexpensive and efficient way to measure SO 2, and are widely used both in ambient air and flue gases. In these instruments SO 2 is electronically excited by the radiation of an UV lamp, yielding an excited species which fluoresces in the UV. This technique is very sensitive but other gaseous components may interfere. Quenching (e.g. by O 2 or H 2 O) of the excited species can lead to an underestimation of the SO 2 1

concentration. Positive interference occurs by molecules which absorb radiation and fluoresce in the same region than SO 2 (e.g. NO and HC) [3]. In exhaust gases, nitric oxide (NO) is usually the main positive interferences, while oxygen is the most important quenching species if water vapour is removed by a Nafion dryer. Materials and Methods Interference studies SO 2 measurements were performed with a SO 2 monitor from Thermo Environmental Instruments (TEI), Model 43 C-FG (Flue Gas) (detection limit approx..2 ppm) [4]. A detailed description of the instrument is given in chapter 2. NO, NO 2, CO and CO 2, were tested for positive interferences (fluorescence). CO 2, CO and O 2 were tested for negative interferences (quenching). The following gases were used: SO 2 in synthetic air: 19. ppm; SO 2 in N 2 : 39.4 ppm, 9.8 ppm; NO in N 2 : 1%, 89 ppm; NO 2 in N 2 : 5.4 ppm; CO in N 2 : 91 ppm; CO 2 in N 2 : 1%; N 2 (6): 1%; synthetic air: 21% O 2 in N 2. Gas mixtures were produced with a calibrated reference gas diluter (Panacon AG), Model 913-1% and mass flow controllers (MFC), Sierra, Model PS1-5, -5 ml/min. All MFCs were calibrated with a high accuracy flowrate calibration standard (MKS Instruments), Model A-1 (Califlow) prior to their use. If mentioned in the text gas mixtures were diluted with synthetic air (21% O 2 in N 2 ) in a J.U.M. gas diluter, Model 18, approx. dilution ratio 1:12. Absorption spectra The absorption spectra of SO 2, NO and the bandpath filter (emission) were determined with a Varian UV- VIS-spectrophotometer, Model 1E. A 3 mm cell was used to measure the absorption spectra of SO 2 and NO (spectral bandwith.2 nm). The transmission spectra of the excitation filter (interference filter) was measured with a Perkin Elmer UV-VIS-NIR-spectrometer, Model Lambda 9 [5]. Fluorescence spectra Fluorescence spectra of SO 2 and NO were measured with a Perkin Elmer UV-fluorescence spectrometer, Model LS-3 in a 3 mm flow cell. Excitation and emission slits were both set to 1 nm. SO 2 emissions of a diesel engine To quantify the SO 2 conversion rates of a CRT system, a number of tests were performed on a engine test bench at EMPA using a Johnson Matthey CRT installed downstream of a modern heavy duty engine (displacement: 12 liter, rated power: 258 kw, 6 cylinder). The gaseous components SO 2, NO x, NO, CO 2, CO and O 2 were continuously determined before and after the system in the diluted exhaust (dilution ratio 1:12). The effect of operating conditions on engine emissions was investigated by performing the measurements in three single modes (B1 (speed B; 1% load), C75, B25) and two steady state cycles (VERT: four stages of ISO 8178/4 C1-cycle for construction site engines, ESC: European Steady State Cycle). Every experiment was performed using a sulphur free (<1 ppm) and a low sulphur (42 ppm) fuel. Gasfilter A cylindrical quartz glass cell (suprasil QS) with an inner depth of 1 mm was used. The cell was filled with 3% NO in N 2. 2

2. Theory of Operation Sulphur dioxide absorbs light in three primary UV regions. Out of these, the band between 19 nm and 23 nm is best suited for fluorescence measurements. Absorption of ultraviolet radiation at a frequency ν 1 by SO 2 yields an excited species SO 2 * with hν 1 being the quantum of energy absorbed by the molecules. SO 2 * can then release its excess energy by fluorescence at a different wavelength, typically between 24-42 nm, as given in reaction (1) with a rate constant k f [6]. SO kf 2 + hγ 1 SO2 * SO2 + hγ 2 (1) Negative bias Two processes compete with fluorescence for the fate of the excited SO 2 intermediates: quenching (2) and photolysis (3). kq SO2 * + M SO2 + M (2) kp SO2 * SO + O (3) Where k q and k p denote the rate constants for quenching and photolysis, respectively. Since k q and k p remain relatively constant over a wide range of temperatures the fluorescence intensity only depends on the concentration of the quenching compound M. Quenching can be accounted for by calibrating with a standard that contains the same concentration of M as the sample. This is typically the case for measurements at ambient oxygen concentrations. If M is strongly variable, then stabilising its concentration by dilution with a gas containing high amounts of M is another option. This approach might e.g. be used by diluting the exhaust with synthetic air. Positive bias The SO 2 monitor will measure as SO 2 any species which absorbs at about 19-23 nm and fluoresces at 34-41 nm. Prior investigations of the fluorescence method point to positive interferences from nitric oxide (NO), carbon disulfid (CS 2 ) and ethylene (C 2 H 2 ) [3, 6]. From these compounds in most exhaust gases only NO is present at significant concentrations. Figure 1 shows the absorption spectrum of SO 2 and NO in the region 19 26 nm. Both gases are showing several bands which belong to different vibronic states of the molecules [7]. Because the bands of nitric oxide are separated by several nm it should be possible to excite single vibronic states of sulphur dioxide without absorption (interference) of nitric oxide. If both gases are excited they fluoresce in a broad overlapping band continuum (Fig. 2). With a high resolution spectrophotometer about 25 lines can be resolved from the fluorescence spectrum of SO 2 [8], however, since the SO 2 monitor transmits a broad wavelength region sulphur dioxide fluorescence cannot be determined without interferences from nitric oxide. The ratio of SO 2 to NO fluorescence (Fig. 2) at least can help to find a wavelength region (emission) with a lower NO interference. 3

There are two main options to overcome positive interferences caused by fluorescence. Often it is possible to measure the concentration of the interfering compound in the exhaust gas and calculate its fluorescence out of this (chapter 3). Alternatively, the excitation or the emission filter of the SO 2 monitor might be modified to lower the excitation of the interfering compound or to preferentially filter its fluorescence radiation (chapter 4). 2 1.5 sulphur dioxide absorption 1.5 nitric oxide 19 2 21 22 23 24 25 26 wavelength [nm] Figure 1: Absorption spectra of SO 2 (5% in N 2 ) and NO (3% in N 2 ) (spectral bandwidth.2 nm) 1 SO 2 /NO fluorescence 8 fluorescence intensity.8.6.4.2 sulphur dioxide nitric oxide 6 4 2 SO 2 /NO fluorescence 22 27 32 37 42 wavelength [nm] Figure 2: Fluorescence spectra of SO 2 (1.1% in N 2 ) and NO (.9% in N 2 ) (excitation and emission slits 1 nm) (excitation wavelength 215 nm) and the ratio of SO 2 to NO fluorescence Commercial monitor The general set-up of the SO 2 monitor (TEI, Model 43 C-Flue Gas) [4] is shown in Figure 3. The gas flows through a "Kicker" which removes hydrocarbons from the gas stream through a selective permeation membrane. The excitation light is produced at 1 Hz by a pulsed xenon flash lamp and filtered by a set of four interference mirrors (excitation filter) which transmit light between 195-235 nm (Fig. 4). 4

Sample Gas In Kicker Xe-Lamp Excitation Filter Fluorescence Chamber Reference Detector Emission Filter PMT Pump Figure 3: Schematic representation of the SO 2 monitor 43 C-FG (PMT: photomultiplier tube) The emission filter is a combination of two bandpass filters (Fig. 5). It selects light between 34 and 41 nm before the emitted radiation reaches an orthogonally oriented photomultiplier tube. A photodetector monitors the light from the lamp. Its signal is compared to a reference signal and used to control the lamp intensity. 1 1 8 8 transmission [%] 6 4 transmission [%] 6 4 2 2 18 22 26 3 wavelength [nm] 3 35 4 45 wavelength [nm] Figure 4: Transmission spectrum of the interference mirrors (excitation filter) Figure 5: Transmission spectrum of the two bandpass filters and the resulting emission filter 5

3. Numerical corrections To determine the SO 2 concentration in complex gas mixtures e.g. in the exhaust of a heavy duty engine, small concentrations of sulphur dioxide have to be determined in the presence of large concentrations of CO 2, O 2, H 2 O, NO x, CO, various hydrocarbons et cetera. Consequently the positive and negative interferences of these gases on the SO 2 fluorescence measurement have to be taken into account. Therefore we investigated the cross-sensitivities of the SO 2 monitor (TEI 43 C-FG) with respect to the fluorescence of NO, NO 2, CO and CO 2 and the quenching of the SO 2 fluorescence by O 2, CO 2 and CO. Water vapour and the hydrocarbons were not taken into considerations since they can be removed from the exhaust gas with a Nafion dryer or a hydrocarbon kicker, respectively. For these experiments gas concentrations as expected in the exhaust of a diesel engine were chosen (Table 1). concentration raw gas diluted gas O 2 5-15% 19.5-2.5% CO 2-1% -.8% CO -6 ppm -5 ppm NO -1 ppm -8 ppm NO 2-3 ppm -25 ppm Table 1: Gas concentrations used for the study of interferences (dilution ratio 1:12 with synthetic air) Set-up The excited SO 2 and NO molecules are quenched by oxygen, which leads to a decrease in fluorescence intensity (Fig. 7). Whereas this effect is strong for nitric oxide, oxygen quenching of sulphur dioxide fluorescence is smaller. To lower the NO fluorescence all measurements were executed at elevated oxygen concentrations in the diluted exhaust (Fig. 6). As a result the rejection ratio of NO, i. e. the number of NO molecules with the same fluorescence as one SO 2 molecule, can be increased from 5 (% O 2 ) to 28 (19% O 2 ). raw gas gas diluter approx. 1:12 SO 2 - Monitor 43 C-FG (diluted gas) synthetic air O 2 /N 2 Figure 6: Set-up used for the interference studies and the SO 2 determination in an exhaust gas 6

fluorescence per ppm SO 2 [CU] 1.6 1.5 1.4 1.3 1.2 1.1 1..25.2 sulphur dioxide.15.1 nitric oxide.5. 5 1 15 2 oxygen concentration [%] fluorescence per ppm NO [CU] Figure 7: Quenching of sulphur dioxide and the nitric oxide fluorescence at different oxygen concentrations (CU: calibration units; i. e. relative to a SO 2 standard with an oxygen content of 21 %) Negative bias The negative bias of carbon monoxide (CO), carbon dioxide (CO 2 ) and oxygen (O 2 ) on SO 2 fluorescence was determined. The concentrations of CO, CO 2 and O 2 were varied within the concentrations expected for the diluted exhaust of a diesel engine (Tab. 1). By diluting the raw gas with synthetic air the oxygen concentration was stabilised (oxygen content in the diluted gas: 19.5-2.5% O 2 ). Therefore oxygen quenching was nearly constant and can be taken into account by calibrating the SO 2 monitor with a SO 2 standard in synthetic air. Quenching of the SO 2 fluorescence by CO and CO 2 in the diluted gas was less than 1%. Positive bias The flue gas components nitric oxide (NO), nitrogen dioxide (NO 2 ), carbon monoxide (CO) and carbon dioxide (CO 2 ) were tested for positive interferences. In the concentration range examined (Tab. 1) fluorescence of NO (rejection ratio 28 at 19% O 2 ) and a weak NO 2 fluorescence (rejection ratio 36 at 6% O 2 ) were detected. The SO 2 fluorescence can be determined from the total fluorescence measured with the SO 2 monitor by subtracting the NO fluorescence. The NO fluorescence can be calculated from the NO fluorescence coefficient K(NO) * and the NO concentration c(no) (4). F( SO2 ) = Ftot K( NO) c( NO) F(SO 2 ): SO 2 fluorescence F tot : total fluorescence K(NO)*: NO fluorescence coefficient c(no): NO concentration in the exhaust gas Additionally quenching of the NO fluorescence by O 2, CO 2 and CO was examined. NO fluorescence is quenched in the presence of O 2 and CO 2 (Fig. 8+9). Therefore the NO fluorescence coefficient K(NO)* has to be calculated from the NO fluorescence coefficient 7 (4)

K(NO) (in the absence of O 2 and CO 2 ) and the oxygen and carbon dioxide quenching. If the oxygen and carbon dioxide concentrations vary in a small concentration range O 2 and CO 2 quenching of the NO fluorescence can be described as linearly depending on O 2 and CO 2 concentration (Fig. 8+9) (5). K( NO) = K( NO) qno / O2 c( O2 ) qno / CO2 c( CO2 ) (5) K(NO)*: NO fluorescence coefficient K(NO): NO fluorescence coefficient in absence of O 2 and CO 2 q NO/O2, q NO/CO2 : coefficient for the O 2, CO 2 quenching of the NO fluorescence c(o 2 ), c(co 2 ): O 2 and CO 2 concentration in the exhaust gas fluorescence per ppm NO [CU].38 y = -3.8E-4x + 9.59E-3.36.34.32.3 19. 19.5 2. 2.5 21. fluorescence per ppm NO [CU].42 y = -3.86E-4x + 4.12E-3.41.4.39.38.37..5 1. oxygen concentration [%] carbon dioxide concentration [%] Figure 8: Quenching of nitric oxide fluorescence at different oxygen concentrations (CU: calibration units) (K(NO)=9.59E-3; q NO/O2 =-3.8E-4) Figure 9: Quenching of nitric oxide fluorescence at different CO 2 concentrations (O 2 18%) (CU: calibration units) (q NO/CO2 =-3.86E-4) Limitations The NO interferences may change due to ageing of the Xe-flash lamp. Therefore the NO fluorescence coefficient K(NO) and the coefficient for the O 2 and CO 2 quenching of the NO fluorescence q NO/O2 and q NO/CO2 have to be determined before each SO 2 measurement. Because NO fluorescence is quenched by O 2 and CO 2 all three gases have to be determined to correct the SO 2 fluorescence. 8

Example SO 2 emissions of a diesel engine equipped with a CRT system The developed numerical corrections were used to determine the SO 2 concentration in the exhaust of a diesel engine equipped with a continuously regenerating trap system (CRT). The CRT is comprised of an oxidation catalyst upstream of a particulate filter. The catalyst oxidises a proportion of NO in the exhaust stream to form NO 2, which is utilised to combust the soot trapped in the particulate filter [9]. SO 2 may be oxidised in a side reaction leading to sulphate, which can make a significant contribution to the particulate matter emission. Numerical corrections SO 2, NO, CO 2 and O 2 were continuously measured in the diluted exhaust (dilution ratio 1:12). NO, CO 2 and O 2 concentrations were used to calculate the NO fluorescence. The NO fluorescence was subtracted from the total fluorescence to calculate the SO 2 concentrations. The NO fluorescence coefficient and the coefficient for the O 2 and CO 2 quenching of the NO fluorescence were determined in the laboratory before. Results In front of the CRT-system SO 2 concentrations were mostly below the detection limit of.3 ppm using sulphur free fuel, but could easily be quantified when the engine operated on fuel with a higher sulphur content. The sulphur dioxide concentration was in good agreement with the values calculated from the sulphur content of the fuel. After the CRTsystem the SO 2 concentration was generally low. This was probably due to the oxidation of sulphur dioxide to sulphuric acid on the oxidation catalyst. Surprisingly, SO 2 concentrations were significantly higher downstream than upstream of the CRT system during the high temperature modes of one steady state cycle (VERT cycle). This indicates that SO 2 is accumulated on the particulate filter possibly as sulphuric acid or sulphate - at moderate temperatures (42-43 C) and liberated as SO 2 at elevated temperatures (62-63 C) (Fig. 1) [2]. 6 SO 2 concentration [ppm] 5 4 3 2 1 after CRT stage 1 64 C before CRT stage 2 43 C stage 3 42 C stage 4 59 C stage 5 64 C Figure 1: SO 2 concentration before and after the CRT system during the VERT cycle 9

4. Physical Modifications Due to the limitations of the numerical correction mentioned it would be desirable to increase the selectivity of the SO 2 monitor. In general there are two possibilities by either improving the excitation or the emission filter. By changing the excitation filter of the SO 2 monitor it should be possible to lower the excitation of nitric oxide. By modifying the emission filter NO fluorescence emitted should be preferentially filtered. Improvement of the excitation filter The excitation filter of the SO 2 monitor 43 C-FG transmits light between 195-235 nm (Fig. 4). Both sulphur dioxide and nitric oxide absorb in this wavelength region and fluoresce in an overlapping band continuum (Fig. 1+2). Therefore it would be necessary to selectively excite single vibronic states of SO 2 without absorption (interference) of NO. We constructed a gasfilter which was be filled with nitric oxide (3% NO in N 2 ) and placed between the Xe flash lamp and the excitation filter. This filter selectively absorbed the radiation exciting the nitric oxide molecules. In laboratory experiments with this gasfilter it was possible to increase the rejection ratio of nitric oxide by a factor of ten. By this it is possible to measure low sulphur dioxide concentrations in the presence of high nitric oxide concentrations without a numerical correction. 5. Conclusions UV-fluorescence is a very sensitive method to determine SO 2 concentrations in various gases and is widely used both in ambient air and flue gases. In the diluted flue gas of a waste incinerator, for example, sulphur dioxide concentrations can be determined with a sufficient precision to judge the observance of the emission limits. However, if small concentrations of sulphur dioxide have to be determined in complex gas mixtures the positive and negative interferences of these gases on the SO 2 fluorescence measurement have to be taken into account. We have investigated the cross-sensitivity of a commercially available SO 2 monitor (TEI 43 C-FG) with respect to the fluorescence of NO, NO 2, CO and CO 2 and quenching of the NO and the SO 2 fluorescence by O 2 and CO 2. Oxygen was found to be the most important quenching species for SO 2 fluorescence. However, quenching of sulphur dioxide fluorescence can be overcome by diluting the raw gas and calibrating the SO 2 monitor with a SO 2 standard in synthetic air. Nitric oxide poses the most serious positive interference. NO fluorescence can be corrected by measuring the NO concentration and calculating the NO fluorescence. Since oxygen and carbon dioxide were found to quench the NO fluorescence their effect was also taken into considerations. By this approach it was possible to measure low concentrations of SO 2 (detection limit.3 ppm) at highly variable O 2 (4-19 Vol-%) and NO (3-12 ppm) concentrations. The numerical corrections developed were applied in a project studying oxidation and storage processes of sulphur oxides in a continuously regenerating trap (CRT)-system. 1

Laboratory experiments to improve the excitation filter of the SO 2 monitor are promising. By installing a gasfilter in front of the excitation filter the rejection ratio of NO could be increased by a factor of 1. However, further experiments are needed in this respect. 6. Literature 1. BUWAL, Bericht über die lufthygienischen Massnahmen des Bundes und der Kantone. 1999: Bern. 2. Mohn J., et al. CRT-Its impact on nitrogen and sulphur oxide emissions. in Energy technologies for a sustainable future. 2. PSI Villigen: PSI. 3. Luke W. T., Evaluation of a commercial pulsed fluorescence detector for the measurement of low-level SO 2 concentrations during Gas-Phase Sulfur Intercomparison Experiment. Journal of Geophysical Research, 1997. 12: p. 16255-16265. 4. Inc. Thermo Environmental Instruments, Model 43C Pulsed fluorescence SO 2 analyzer. 1995: Franklin. 5. Horn K., Transmission und Reflexion schwierig zu messender optischer Proben. Photonik, 1998. June: p. 4-41. 6. Okabe H., Splitstone P. L., and Ball J. J., Ambient and source SO 2 detector based on a fluorescence method. Journal of the Air Pollution Control Association, 1973. 23: p. 514-516. 7. Duchesne J. and Rosen B., Contribution to the study of elctronic spectra of bent triatomic molecules. Journal of Chemical Physics, 1947. 15: p. 631-644. 8. Lotmar W., Über die Fluoreszenz von Schwefeldioxyd. Zeitschrift für Physik, 1933. 83: p. 765-785. 9. Cooper B. J. and Thoss J. E., Role of NO in diesel particulate emission control. SAE Technical paper, 1989. 8944. 11