COASTAL INDIA. Supply & Application of: Epsilon Midsun 570 Gen-4 RTV HVIC (High Voltage Insulator Coating) and

Similar documents
EPSILON EM-SILPROCOAT RTV ANTI-CORROSION RUBBER COATING TECHNICAL DATASHEET & SPECIFICATIONS

Si-COAT 570 RTV Silicone HVIC. Reliability & Beyond. Seminar Presentation

Cigré WG C Topics: The selection of insulators with respect to polluted conditions

fire Charcoat Charcoat IC Passive Protection

Midsun HVIC silicone is not affected by UV light, temperature, corrosive environments, or ATH pitting from dry band arcing.

Midsun HVIC silicone is not affected by UV light, temperature, corrosive environments, or ATH pitting from dry band arcing.

PERFORMANCE ANALYSIS OF OVERHEAD PORCELAIN INSULATOR UNDER DIFFERENT CONTAMINATIONS

EXPERIMENTAL INVESTIGATION OF EFFECT OF UV RADIATION ON FLASHOVER VOLTAGE OF POLYMERIC INSULATORS WITH AND WITHOUT CONTAMINATION

Polluted Outdoor Insulators Maintenance and Washing

Effect of UV-Rays and Salt Contamination on 33kV Silicon Composite Insulators

POLLUTION PERFORMANCE OF SILICONE AND EPDM INSULATOR PROFILES

Development of Composite Line Spacers for Distribution Lines

Diagnostic Techniques of Composite Insulators

Predicting Contamination Flashover of Insulators: Successes and Shortcomings of Tests and Simulations

Vijendra Singh Parihar 1, Prof. Anil Kumar Kori 2 1

ILMOS Insulator Leakage Current Monitor

Data Sheet 110kV TD123II dry type outdoor termination

A-PDF PPT TO PDF DEMO: Purchase from to remove the watermark

Ageing Deterioration of Silicone Rubber Polymer Insulator under Salt Water Dip Wheel Test

Performance investigation of composite and RTV SIR coated insulators at a coastal test station

Pins Insulator. Composite/Polymers Insulators

Artificial Accelerated Ageing Test of Silicone Rubber Housing Material for Lightning Arrester

INSULATOR REQUERIMENTS:

Performance of Thermoplastic Elastomeric and Thermoset Insulators under Accelerated Acid Rain Multistress Conditions

SANERGRID, représentant exclusif France

Different Characteristics of Artificially Polluted High Voltage Composite Insulators

Composite Insulator Components

Performance Analysis of 33 kv Polymer and Porcelain Insulators under Various Pollution Conditions at Costal Regions

ESDD PREDICTION OF OUTDOOR POLYMER INSULATORS. Abdelrahman Khaled

ESDD MEASUREMENTS IN THE POWER SYSTEM OF CRETE

Evaluation of Silicone Rubber Insulators used in High-Voltage Transmission Lines Anwar Ul-Hamid, Khaled Y. Soufi, and Ibrahim AI-Hamoudi

INCLINED PLANE TESTS OF COMPOSITE, SILICONE RUBBER AND COMPOSITE SILICONE RUBBER COATED MATERIALS

Mitigating Contamination Related Issues on T&D Equipment. Lily Hoyer Simon Chan

Laboratory Investigation on Hydrophobicity and Tracking performance of Field Aged Composite Insulators

Natural Contamination and Surface Flashover on Silicone Rubber Surface under Haze Fog Environment

Experimental analysis of hydrophobic characteristics of Silicone rubber (SiR) insulators under different climatic conditions

Prediction of flashover voltage of non-ceramic insulators under contaminated conditions

Industrial Coatings: HIGHLY DURABLE, SUPERHYDROPHOBIC AND OLEOPHOBIC. (White Paper) NeverWet LLC

HIGH VOLTAGE INSULATORS. By JP Holtzhausen. Glass. Bushings & hollow core insulators. Cap & pin insulators

Comparison of effects of Various Contaminations on SiR insulators

Effect of Metal Ring on the Field Distribution of Outdoor Polymeric Insulator

Evaluation of Actual Field Ageing on Room Temperature Vulcanized Silicone Rubber Coating of Ceramic Insulators on 230/63 Substation

15 O&M Issues in Solar Farms

CO 2 Cleaning and Its Effectiveness in Cleaning Energized Medium-Voltage Equipment

Energy Division Insulators

TROPICAL CLIMATE EFFECT OF HYDROPHOBICITY AND SURFACE LEAKAGE CURRENT ON ELECTRICAL INSULATION MATERIALS (SILICONE RUBBER AND FLY ASH)

Polymer Suspension Insulators 69kV to 765kV

COMPARATIVE LABORATORY PERFORMANCE CHARACTERISATION OF SILICONE RUBBER TEXTURED INSULATORS

INSULATION, ASSET AND WILDLIFE PROTECTION Steve Parker, Business Development

Composite Outdoor High Voltage Insulators in Crete - 37 Years of Experience

CHAPTER 6 HIGH VOLTAGE ELECTRICAL TESTING RESULTS

Measurement of Leakage Current for Monitoring the Performance of Outdoor Insulators in Polluted Environments

Selection between indoor or outdoor DC yards D. WU*, U. ÅSTRÖM, L. ARÉVALO, R. MONTAÑO, B. JACOBSON ABB HVDC SWEDEN

GROUP A. Polymeric Insulators.

CS type composite silicone insulators up to 750 kv overhead lines for all pollution of the atmosphere levels

A Study of Critical Positive Impulse Flashover of 24 kv Contaminated Insulators

Mapping HV Insulators Pollution in the Mediterranean Island of Crete

SYLGARD High Voltage Insulator Coating. A guide to proper application

Comparative study on field collected samples of aged silicon rubber composite coatings for high voltage insulators

Research methodology for the life evaluation of Hollow polymer insulators for High Voltage Applications

Porcelain versus Polymer Insulator- A Changing Era in Transmission Lines

Measurement of surface resistance of silicone rubber sheets under polluted and dry band conditions

Electric field analysis of 132kV EPDM insulator and correlation with ageing features

The Reliability Study of the Statistical Method on Insulator Dimensioning of (U)HVDC Lines with Regard to Pollution Conditions

SILICONE RUBBER INSULATORS WITH NOTCHED SURFACE

PS2: Lifetime management, deterioration and ageing of substation equipment

6C-001 High-Voltage Pin-Type Insulator

Insulators pollution problem: Experience from the coastal transmission system of Crete

CONDITION ASSESSMENT OF A FIELD-AGED 150 kv HTV SIR SUSPENSION INSULATOR FOLLOWING FLASHOVER

Durability of Cement Based Building Materials

INSULATORS NEW. See page J-4 for more information.

Artificial intelligence assessment of sea salt contamination of medium voltage insulators

Laboratory Investigation on Hydrophobicity of New Silicon Rubber Insulator under Different Environmental Conditions

Polymer Cutout Testing Recommendations

Porcelain Insulator Performance under Different Condition of Installation around Aligarh

An Investigation Into The Methodology To Develop An Insulator Pollution Severity Application Map For South Africa

Height Pole Care and Maintenance

BELTRAN TECHNOLOGIES, INC. Process gas cleanup from Coal and Municipal Gasification. By Duane S Abbott Beltran Technologies, Inc.

Q30 SUPER PROTECTIVE FILM

SV-ACFC Aluminum Conductor Composite Core (ACCC)

INSULATORS. Industry photo: should be a the same image as larger industry photo. Either a different crop or different angle.

Technical Specification for LV ABC Fuse Switch Disconnectors

15~35KV Termination Kit

Effect of Some of Climatic Conditions in the Performance of Outdoor HV Silicone Rubber Insulators

Polymer Station Post Insulators for 69 to 345 kv Applications

Low Fouling and Energy Consumption two-stage Forward and Reverse Osmosis desalination Process

Challenges caused by cold climate when designing, constructing and operating overhead lines Sonja Berlijn and Bergit Svenning Statnett

Reprinted from the Proceedings of the 2001 IEEE/PES Transmission and Distribution Conference and Exposition, Atlanta, Georgia.

Specification for Polymer Disc Insulator

Transmission Silicone Insulators Line Post 69 kv to 230 kv

Solving Corrosion Under Insulation Utilizing FOAMGLAS Cellular Glass Insulation Systems

SPECIFICATION FOR POLYMER DISC INSULATOR

Technical Specification for Insulated Low Voltage Single Core Copper Cable

ECONOMIC ANALYSIS OF 400 KV TRANSMISSION TOWERS WITH CROSS ARMS INSULATORS

Polymer Insulators and Coatings in the Cretan Power System. The Transmission Line Case

Investigation of leakage current flow through wooden poles structures on overhead distribution system

What Forges High Reliability

Surface Roughness Effect on the Hydrophobicity Characteristic of Operating Composite Insulators

CERTS Microgrids. Tom Jahns Professor, University of Wisconsin-Madison. LPPC Rates Roundtable May 21, 2013

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS

Transcription:

Supply & Application of: Epsilon Midsun 570 Gen-4 RTV HVIC (High Voltage Insulator Coating) and Epsilon Midsun 579 RTV Anti-Corrosion Coating In COASTAL INDIA Supply & Application of 8,000kg of Epsilon Midsun HVIC by Epsilon Asia Group: 2011

Epsilon: Key Partners in India Epsilon an engineering company and is exclusive national partners with: Dongfang India for Minimal-Oil Boiler Combustion Systems Dongfang-Hitachi VFDs, PV Inverters SYCG/Nexans XLPE Cable Epsilon Midsun HVIC & Silicones

Switchyard Overview Insulators prone to severe contamination due to: Coastal Location Cooling Tower Drift as Seawater is used for cooling No Drift Eliminator Installed at the Cooling Towers at the time Extreme Leakage Current & Corona observed Frequency of unplanned outages due to flashovers was increasing rapidly Extreme Corrosion on JBs and metal infrastructure observed epsilon

Contaminated Insulator Surfaces Despite Extremely frequent Washing Cycles, pollution deposits were unavoidable The salt deposit in this image is within 7 days of the previous wash

Extreme Corrosion to Ferrous Infrastructure Metal Infrastructure Corroding within 18 months Such Corrosion Results in degrading IP54/IPxx ratings which pose a safety risk Changing JBs requires recommissioning of equipment After coating with EM 579, Resistance to Corrosion Fortified epsilon

Corona Visible with the naked eye epsilon

Corona Visible through UV Corona-Cam Watch the Full Video at: http://www.youtube.com/watch?v=nlzrz6myd2m

HVIC of Choice: Epsilon Midsun 570 Gen-4 RTV Ultra-Hydrophobic RTV High Voltage Insulator Coating (HVIC) Targets: Mitigate Risks of Leakage Current Reduce the need for Insulator Washing Mitigate Risks of Flashovers

Conductive Tracking Path Cannot be Formed (All drops of water are discrete)

IEEE Evaluation of RTV Coating in Coastal Conditions IEEE Evaluation of RTV Coating for Station Insulators subjected to Coastal Pollution H.M Schneider, Senior Member, EPRI High Voltage Research Centre) Performance of Breaker Support Insulators (BSIs) tested before and after application of RTV Coating Resistance to Flashovers tested in field tests to check for additional equivalent creepage imparted by the coating

The results Measurements are given in ESDD as: Quantity of NaCl per unit area (mg/cm 2 ) Test Reports showed ESDD as high as 0.034 mg/cm 2 several months after wind storms, natural and manual washing Uncoated BSIs flashed over at 209kV RTV coated BSIs flashed over at 300kV Improvement of performance of: 43.5% withstand voltage

Hydrophobicity Recovery (CPRI labs Test) It is essential for the silicone material to recover its hydrophobicity for long-term effective performance Epsilon HVIC Test Results of Hydrophobicity recovery at CPRI Hydrophobicity Tested (CPRI Labs) Virgin Sample HC 1 After 100-hours continuous exposure to Corona Epsilon Midsun Hydrophobicity Recovery within 48 hours of Corona Destruction HC 6 HC2 Hydrophobicity Classification (HC level as per STRI) epsilon

Hydrophobicity (Water-Repellency) Classification Hydrophobicity Classification (HC) goes from HC1 to HC7 HC1: Completely Hydrophobic HC7: Completely Hydrophilic HC Description HC1 HC2 HC3 Only discrete droplets formed. θ r 80 (or larger) for majority of droplets Only discrete droplets formed. 50 <θ r < 80 for the majority of droplets. Only discrete droplets formed. 20 < θ r <50 for majority of droplets. Usually they are no longer circular HC6 Wetted areas cover > 90% small un-wetted areas still observed HC7 Continuous water film Typical Examples from HC1 to HC6 epsilon

Application Procedure

Surface Preparation epsilon

Gentle Scraping of Salt Deposits epsilon

Application of Epsilon HVIC Airless Spray Application epsilon

Application of Epsilon HVIC epsilon

Corona Eliminated on Coated Insulators

Epsilon HVIC Team Safety Training + Documentation 29-30 SEP 2011 Scheduled Start: 01 OCT 2011 Actual Site Mobilization: 01 OCT 2011 Scheduled End: 31 OCT 2011 Actual End: 98.5% job completed by 31 OCT 2011 At least 9 working days were lost due to UPCL not being given shutdown permission by Karnataka Government epsilon