Temporary Construction Loads Over I-Joist Roofs And Floors

Similar documents
Georgia-Pacific Wood Products LLC Revised June 25, 2018

Norbord TallWall/Windstorm/QuakeZone Rated Sheathing for Use with IRC Energy-Heel Trusses Revised February 20, 2018

Stark Truss Company, Inc. Revised December 14, 2018

PR-L274 Nordic Structures Revised April 16, 2017

Effect of Large Diameter Horizontal Holes on the Bending and Shear Properties of Laminated Veneer Lumber

PinkWood Ltd. Revised September 29, 2017

Boise Cascade Company Revised June 25, 2018

International Beams Revised June 15, 2018

RoyOMartin TuffStrand and Windbrace 7/16 Performance Category OSB PR-N129 Martco, L.L.C. Revised November 6, 2017

Technical Topics. Wood I-Joist Floors, Firefighters and Fire

GP LAM Laminated Veneer Lumber Georgia-Pacific Wood Products South LLC Revised March 20, 2015

Warmboard-S Radiant-Floor Heating Panels PR-V180 Warmboard, Inc. Revised February 19, 2018

Pacific Woodtech Corporation Revised January 26, 2018

Murphy Laminated Veneer Lumber Murphy Engineered Wood Division Revised January 24, 2017

Murphy Laminated Veneer Lumber Murphy Engineered Wood Division Revised May 30, 2013

PinkWood Ltd. Revised June 3, 2015

Glulam Beam Camber. August 2011

Building Division Informational Handout

TT-006B JULY 2008 TABLE A. ASTM C 627-TESTED ASSEMBLIES NOT LISTED BY TCNA. Tile Adhesive

LP SmartSide Precision Series Soffit and Rated Sheathing/Ceiling Deck Louisiana-Pacific Corporation Revised November 20, 2013

PinkWood Ltd. Revised February 3, 2018

PR-L274C Nordic Structures Revised April 16, 2017

LP SmartSide Strand Substrate Soffit and Rated Sheathing/Ceiling Deck Louisiana-Pacific Corporation Revised June 20, 2017

Structurlam Products LP Revised May 23, 2017

Structurlam Products LP Revised August 3, 2018

ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be

IB Series I-Joists International Beams, Inc. Revised June 25, 2014

LP SolidStart I-Joists Louisiana-Pacific Corporation Revised October 6, 2015

1 Exam Prep BCSI Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses Questions and Answers

Installation of Stucco Exterior Finish Over Wood Structural Panel Wall Sheathing

TECH BULLETIN. SIP No. Subject: Engineered Wood Lap Siding from Louisiana-Pacific. Date: August 2010 (Revised January 2015)

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading

LP SmartSide Strand Substrate Treated-Engineered-Wood Lap & Panel Siding Louisiana-Pacific Corporation Revised December 2, 2016

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading

KING BEAM 3000 and BOISE GLULAM PR-L313 Boise Cascade Wood Products, L.L.C. Revised May 29, 2017

R Code and Commentary for 2012 NC Residential Code final 03/06/13

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 Virginia Residential Code

Joint Evaluation Report

Pulaski County, Virginia Practical Wall Bracing

LPI 56 Technical Guide

WFCM 90 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 120 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

Roseburg RIGIDLAM LVL Roseburg Forest Products Company Revised May 31, 2018

System Report. Design for Combined Shear and Uplift from Wind. and equipment, and Section Analysis

Wood Truss Restraint and Bracing Guide

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

Joint Evaluation Report

Joint Evaluation Report

A Simple Solution for Meeting

Garage/Accessory Structures

BROADSPAN. I-Joist Design Brochure. Design properties for I-joist applications in the U.S. for residential floor systems. I-Joist Design Brochure

WFCM 110 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 100 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

International Beams, Inc. Revised June 20, 2018

DECK PERMIT APPLICATION

Typical Deck Details. Albemarle County, Virginia. Based on the 2012 Virginia Residential Code

BROADSPAN. LVL Design Brochure. Design properties for LVL header and beam applications in the U.S. for residential floor and roof systems

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 International Residential Code

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

2012 Wood Frame Construction Manual: Wind Load Distribution on Buildings Load Paths

ADVANCED WALL FRAMING

Joint Evaluation Report ICC-ES (800) (562)

UDC Wall Bracing Provisions Emergency Rule effective date 4/1/2014. A How To guide for use of the new provisions

Nordic Structures Revised May 9, 2018

Nordic Structures Revised February 28, 2018

I-Joist and LVL Installation Guide

Minimum required percentage of length of braced wall band on each storey 4

MAX-CORE I-JOIST DESIGN MANUAL-US

TYPICAL BEARING WALL FRAMING

LATERAL LOAD CONNECTIONS FOR LOW-SLOPE ROOF DIAPHRAGMS

VERTICAL AND HORIZONTAL LATERAL LOAD SYSTEMS

Installation Guide and Safety Manual

FIGURE R502.2 FLOOR CONSTRUCTION

6300 Enterprise Ln Madison, WI

Featuring Selection and Installation Information for Lateral Wind Loads

MBOIA IRC Wall Bracing. Mark Halverson. Maine Building Officials and Inspectors Association. First Last

Open-Web Truss Long Span Installation Guidelines

Dimensional Changes In Structural Glued Laminated Timber

Plywood and OSB Meet Everyday Challenges

INTRODUCTION TO LATERAL DESIGN

Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips)

Joint Evaluation Report ICC-ES (800) (562)

Joint Evaluation Report ICC-ES (800) (562)

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

2.2E Parallam PSL Deep Beam

WOOD I-JOIST AWARENESS GUIDE

2.2E Parallam PSL Deep Beam

Chapter 10: Roof Truss Legalese

FEMA P-593 STEP-BY STEP PRESCRIPTIVE RETROFIT FOR CRIPPLE WALL BRACING & ANCHORAGE TO FOUNDATION

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board

OUR COMPANY OUR WARRANTY OUR GUARANTEE

Wood Shear Wall Design Examples For Wind

TYPICAL BEARING WALL FRAMING Joints in plates must be offset by 24 min.

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

Designing to Meet IRC Fire Protection Provisions for I-Joist Floor Systems

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Transcription:

T E C H N I C A L N O T E Temporary Construction Loads Over I-Joist Roofs And Floors Number J735C July 2012 During construction of light-frame structures it is common to see relatively heavy loads placed over partially constructed floors and roofs. This is usually done to stage materials as part of the construction process. Some common examples of this are the stacking of floor panels over bare floor joists, placement of wall framing bundles on sheathed floors in anticipation of wall construction, or the placement of gypsum wall board bundles on sheathed floors prior to the installation on walls or ceilings. Proper placement of such heavy loads in a partially completed light-framed structure is necessary to prevent damage to the structure and/or injury to the work crew. Fortunately, following a few simple rules, as discussed below, can minimize the risk of such problems. Note that walking on unrestrained joists can result in serious injury. 1. Recommendations presented in this Technical Note are appropriate for floors and flat roofs. Placement of temporary loads on pitched roofs can overstress the roof support connections at the ridge and overhang. In addition, placement of bundles of panel products on a sloped base can cause the panels to slide off when the bands are cut. This can cause serious projectile damage to equipment as well as creating a hazard for personnel below. 2. Never place heavy loads over a bare I-joist floor or roof without lateral (overturning) restraint securely fastened in place. At I-joist supports, this means blocking or a rim joist nailed to the wall plate and I-joists. Each end of the framing bay and every 25 feet of bare framing must have 8 feet of diagonal bracing or other means to provide a braced bay. Across the length of the bare joists, apply temporary 1x4 (minimum) bracing board running the full width of the framing bay and spaced at 8 10 feet on center. See Figure 1. It is important to note that the diagonal bay bracing and perpendicular bracing must be used together. The perpendicular bracing is inadequate without the bay bracing to provide stability and the diagonal bay bracing by itself provides no stability to the framing members between the braced bays. 3. Wall sheathing must be installed below the floor (or roof) level to provide for lateral stability of the structure before temporary loads are placed.

2 4. The maximum temporary load at a given location shall be limited to a single sling/unit of wood structural panels (a stack 4 feet wide x approximately 32 inches high x the length of the wood structural panel), a single sling/unit of gypsum wallboard (up to 5 feet wide x 30 inches high x the length of the wallboard) or a sling/unit of lumber (approximately 3 feet wide x 24 inches high x the length of the lumber). 5. The long dimension of temporary loads shall be placed perpendicular to the framing and only at locations shown in Figure 2. 6. The long dimension of temporary loads shall not be placed parallel to floor joists, even after sheathing has been attached, without permission from a design professional. 7. Panel-type temporary loads may be placed with one edge or end cantilevering over the edge of the floor a distance not exceeding 1/4 of the bundle width or length, respectively. Lumber bundles shall never be placed such that whole lengths of lumber members in the bundle are positioned over the edge of the floor. Cutting the straps of the bundle in such situations can cause serious projectile damage to equipment as well as creating a hazard for personnel below. To ensure a safe job site, place lumber bundles approximately two feet inside the edge of the floor. 8. Temporary construction loads as shown in this Technical Note may be placed at the cantilevered end of floor joists that extend beyond the wall below by up to 2 feet. All blocking including blocking at the cantilever-end support and blocking or Rim Board attached to the cantilevered-end of the floor joists shall be in place prior to setting the construction loads.

3 TEMPORARY CONSTRUCTION BRACING The following temporary bracing must be completed before placing bundles or walking on floor or roof framing. 1. All end blocking or Rim Boards must be in place. 2. For temporary perpendicular bracing, use a minimum of 1x4 perpendicular to the floor or roof framing and running full width of the floor. At each joist, attach bracing to framing with two 8d nails. Long lengths are recommended with the ends overlapped at a common joist. Lines of bracing should be placed parallel to each other and spaced at 8 to 10 feet on center. 3. To stabilize the perpendicular bracing described in No. 2 above, brace the corners of the floor or roof, and, in long or wide floors and roofs, at intervals not to exceed 25 feet with a minimum of 8 feet of diagonal or bay bracing. Bay bracing may be provided by diagonal temporary bracing at ends as shown in Figure 1 or by fastening at least 4 feet of floor or roof sheathing at each end. Perpendicular bracing described in No. 2 will not work without the diagonal temporary bracing provided at the ends. 4. Remove temporary bracing carefully. Starting with the diagonal bracing at one end, only remove enough bracing to attach sheathing panels one at a time. Once diagonal bracing is replaced by the permanently installed sheathing, the work can progress down the floor or roof, again only removing the perpendicular bracing as necessary immediately before attaching sheathing panels. FIGURE 1 TEMPORARY CONSTRUCTION BRACING Blocking or Rim Board must be in place prior to loading with temporary construction loads Minimum 8' Perpendicular bracing 8' minimum Diagonal temporary bracing not required if floor panels fastened in place 8' 10' between braces Diagonal temporary bracing providing braced bay Temporary perpendicular bracing required if floor not completely sheathed

4 PERMISSIBLE LOADS (at a given location) 1. One unit of wood structural panels (4 feet wide x approximately 32 inches high x length of the wood structural panel), or 2. One unit of gypsum wall board (5 feet wide x approximately 30 inches high x length of the wall board), or 3. One unit of lumber (3 feet wide x approximately 24 inches high x the length of the lumber). 4. Multiple units may be placed on floor providing they are not stacked and all units fall within Area OK for construction loads. FIGURE 2 PERMITTED LOCATIONS FOR TEMPORARY CONSTRUCTION LOADS An overhang of not more than 1/4 of the bundle width at long bundle edge and 1/4 of the bundle length at bundle end is permitted. EXCEPTIONS: 1. Overhangs of lumber bundles shall be as described on page 2, item #7. 2. Bundles placed at floor corners shall be as described below. Area OK for construction loads 5 ft 5 ft Area OK for construction loads When placed over corner of floor, building corner should extend past outside of bundle at approximate middle of long bundle edge

Temporary Construction Loads Over I-Joist Roofs and Floors We have field representatives in many major U.S. cities and in Canada who can help answer questions involving APA trademarked products. For additional assistance in specifying engineered wood products, contact us: APA HEADQUARTERS 7011 So. 19th St. Tacoma, Washington 98466 (253) 565-6600 Fax: (253) 565-7265 PRODUCT SUPPORT HELP DESK (253) 620-7400 E-mail Address: help@apawood.org DISCLAIMER The information contained herein is based on APA The Engineered Wood Association s continuing programs of laboratory testing, product research and comprehensive field experience. Neither APA, nor its members make any warranty, expressed or implied, or assume any legal liability or responsibility for the use, application of, and/or reference to opinions, findings, conclusions or recommendations included in this publication. Consult your local jurisdiction or design professional to assure compliance with code, construction and performance requirements. Because APA has no control over quality of workmanship or the conditions under which engineered wood products are used, it cannot accept responsibility for product performance or designs as actually constructed. Form No. J735C/Revised July 2012 www.apawood.org