Installation instruction

Similar documents
RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES

Installation Instructions

Installation instructions

SI T T FST

Conergy SolarFamulus II

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS

SI T T FSS/FSTT Open Fire

Installation Instructions

GENERAL MECHANICAL SYSTEM REQUIREMENTS

ErgoFocus: Installation and User Manual. 1. Technical Data PRE-Installation Operation 11. Keep for future use

InoxSabiana 25 Flues. Stainless Steel Double Wall

Dunbrik A1 Concrete Flue Liners

GENERAL MECHANICAL SYSTEM REQUIREMENTS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual

B41XTCE Gas Fireplace

PRODUCT CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

Smoke Control Damper ESAM Instructions for installation, operation and maintenance 10/2014

KAZAN: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2 2. PRE-INSTALLATION 3 3. INSTALLATION 6 4. OPERATION TESTING 11. Keep for future use

Fireplaces and Chimneys

B36XTCE Gas Fireplace

APPLICATION FOR FINISHED BASEMENT PERMIT

Curtain Wall Stick System (Capped)

Exterior Wall Solutions Building Shell

De Montfort Mark 7 Incinerator (Flatpack)

Installation SBIHA-Black single wall pipe

SMART-LINE / ECO-LINE INSTALLATION GUIDE

Nouveau BBQ Single Flue

lindab we simplify construction LindabSandwichPanels Installation instructions Mineral Wool Panels

Declaration of Performance (DOP)

A EN ROUND STORAGE SILO. Ø480cm, Ø560cm, Ø640cm, Ø720cm ASSEMBLY AND USER MANUAL. ARSKAMETALLI LTD

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: EARTHCORE INDUSTRIES, LLC

LK Manifold Cabinet UNI, LK Prefab Cabinet UNI

NELSON: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2. PRE-INSTALLATION 3. INSTALLATION 4. OPERATION 5. TESTING. Keep for future use

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

tipi: model specifications 1. Technical Data 2 2. PRE-Installation 3 4. Operation 9 Keep for future use

CHIMNEYS AND FIREPLACES

Declaration of Performance (DOP)

PAxFocus. 1. Technical Data PRE-Installation Operation 13. Keep for future use. Oblica 200 Argyle St Fitzroy VIC

Fire Protection Valves

Installation Guide. PAROC panel solutions

These installation instructions cover the installation and operation of Jetmaster Inset and Freestanding Barbecues

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

FLAMRO FKS Ready Cable Duct System

Technical and Dimensional Data. Saf-T Vent SC

SAFETY PRECAUTIONS. Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer.

ARGOS: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2. PRE-INSTALLATION 3. INSTALLATION 4. OPERATION 5. TESTING. Keep for future use

PHAROS: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2. PRE-INSTALLATION 3. INSTALLATION 4. OPERATION 5. TESTING. Keep for future use

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.

ENGLISH INSTALLATION INSTRUCTION MANUAL. N550 Bakers Oven. CERTIFIED for USA & CANADA SAFETY TESTED to UL & ULC-S

SKANTHERM SHAKER: INSTALLATION AND USER MANUAL 1. TECHNICAL DATA 2 2. PRE-INSTALLATION 3 3. INSTALLATION 5 4. OPERATION 9 5.

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

APPLICATION AND LISTING

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers

Series ESK / ESB. Cabinets in Modular Design. Manufacturing Program: ESK-20 ESK-40 ESK-80 ESB Sandwich construction 20 mm, 40 mm and 80 mm

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

Clearly Solar. Installation Instructions. Solar Thermal Flat Plate Collector. Vertical On-roof mounting SHV

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE

Traditional Open Fire

Installation GUIde Please read these instructions before proceeding

Town of Farragut RESIDENTIAL CONSTRUCTION ENERGY EFFICIENCY. LAST UPDATE: July 03, 2014

EMOTION: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2 2. PRE-INSTALLATION 3 3. INSTALLATION 5 4. OPERATION 9 5. TESTING 10. Keep for future use

ON-ROOF ATTACHMENT FLAT COLLECTOR HELIOSTAR

Regency Horizon HZ30E Gas Fireplace

Skantherm shaker: Installation and User Manual. 1. Technical Data PRE-Installation Installation Operation 9. Keep for future use

Technical information & installation advice

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: MASONRY FIREPLACE INDUSTRIES, LLC

FEATURES AND SPECIFICATIONS...2 Installation Choices...2

PORTRAIT WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. 569 Ledge Front

Date of update January 25, 2018 Valid until

Air flue duct for use with ecotec boilers

RH & RV CAVITY BARRIERS

Assembly instruction. Content. Model... Rectangular tiled stove (series 800)

Installation Instructions

MASPORT I5000 INSERT FIRE, AUSTRALIAN MODEL

REScheck Software Version Compliance Certificate

Precast Concrete Trench Drain Systems INSTALLATION INSTRUCTIONS

CHIMNEYS AND FIREPLACES

RESIDENTIAL BASEMENT ALTERATIONS GUIDE

Stack Parking Surface Mounted Stackers

Clearly Solar Solar Thermal Flat Plate Collector Installation Instructions Horizontal On-roof mounting SRH 2.3

Series PV. Compact Switchgear Cabinets. Construction subject to change without notice Dimensions in mm

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Supplementary Standard SB-12. Energy Efficiency For Housing

INGLEBEAMS. Our Inglebeam range is available in either solid aggregate versions or hollow light weight version.

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

Freestanding or Wall Mounted Taps

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: FIRE ROCK PRODUCTS LLC

Leaving Certificate Revision Notes. Airtightness. Potential air leakage paths (the numbered points in section 2.1 give a description for

Installation instructions

Chimneys in Thatched Properties

Building elements. Guideline for SINTEF Technical Approval

Tips. Safety. Installing a Fireplace. Alberta s Safety System. Factory-built fireplaces

INGLEBEAMS. Our Inglebeam range is available in either solid aggregate versions or hollow light weight version.

Transcription:

Installation instruction Ci51 www.contura.eu

114 CERTIFICATE Declaration of performance according to Regulation (EU) 305/2011 No. Ci51-CPR-150821-SE-2 PRODUCT Product type Type designation Manufacturing number Intended area of use Fuel Insert lit with solid biofuels Contura i51 See rating plate on the insert Heating of rooms in residential buildings Wood MANUFACTURER Name NIBE AB / Contura Address Box 134, Skulptörvägen 10 SE-285 23 Markaryd, Sweden CHECKS According to AVCP System 3 European standard EN 13240:2001/AC:2006, EN-13240:2001/A2:2004/AC:2007 Test institute Rein-Ruhr Feuerstätten Prüfstelle, NB 1625, has checked declared performance and issued test report no. RRF-40 15 4068 DECLARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material Rear: 0 mm Side: 700 mm Follow the given conditions in the installation instructions. Risk of falling embers Pass Emissions from combustion CO 0,08% NOx 96 mg/m 3 Surface temperatures Cleaning options Mechanical durability Emissions of hazardous substances Nominal output Efficiency 80% Flue gas temperature in connector at nominal 334 C output OGC 69 mg/m 3 PM 23 mg/m 3 Pass Pass Pass Pass 8 kw EN 13240:2001/AC:2006, EN-13240:2001/A2:2004/AC:2007 The undersigned is responsible for the manufacture and conformity with the declared performance. Niklas Gunnarsson, Business area manager NIBE STOVES Markaryd, August 21, 2015

CONTENTS 115 A warm welcome to Contura. A warm welcome to the Contura family. We hope you will get a great deal of pleasure from your new insert. As a new owner of a Contura insert, you have secured a product with timeless design and long service life. Contura also has a combustion process that is both environmentally friendly and efficient, for the best heat production. Read through these installation instructions carefully before installation. Read how to best light your stove in the lighting instructions. List of Contents Technical specifications 116 Chimney 117 Supply of combustion air 118 Installation distance 119 Placement and adjustment of the insert 121 Installing the surround 125 Assembling grate and top 133 NOTE: Report the installation of a fireplace to your local authority. The owner of the house is personally responsible for ensuring compliance with the mandatory safety requirements and must have the installation approved by a qualified inspector. Your local chimney sweep must also be informed about the installation as this will affect the routines for regular chimney-sweeping services. WARNING! The insert becomes very hot During operation, certain surfaces of the insert become very hot and can cause burn injuries if touched. Also, take heed of the strong heat radiated through the door glass. Placing flammable material closer than the safe distance indicated may cause a fire. Smoulder combustion can cause quick gas ignition with the risk of damage to property and personal injury.

116 FACTS Technical specifications Model i51 Log box (option) Output 6-11 kw Nominal output 8 kw Efficiency 80 % Weight (kg) 215 50 Powerstone (option): + 100 kg Width (mm) 770 400 Depth (mm) 500 500 Height (mm) 1650 500 Connector diameter Ø150 mm ext. General This manual contains instructions about how to assemble and install the Contura i51. More information about the insert is available in the separate installation instructions. To ensure the function and safety of the firebox, we recommend that installation is carried out by an authorised technician. Our Contura agents can recommend a suitable installer; information regarding our agents is available at www.contura.eu Instructions for lighting are also supplied with the insert. Read them carefully and keep them safe for future use. Application to local authority Before installing a firebox or erecting a chimney, it is necessary for you to make an application for permission to your local authority. Ask your local authority for advice regarding regulations and the application. Structural support If the firebox is to be positioned on a wooden joist, a structural engineer should evaluate the load capacity of the floor. When the gross weight exceeds 400 kg, reinforcement of the wooden joists is usually necessary. Floor plate Due to the risk of falling embers, a flammable floor must be protected by a hearth plate. It must extend at least 300 mm all the way around. The hearth plate can consist of natural stone, concrete, metal or glass. A glass hearth plate is available as an accessory for these models. Walls behind If your Contura i51 is to be installed against a combustible wall, the wall must be protected by a firewall or by the integrated protective screen, which is available as an option in some markets. The following material requirements are made of the firewall: The building material must not be combustible. The thermal conductivity coefficient λ must be a maximum of 0.14 W/mK. The thickness of the building material must always be at least 100 mm. In cases where the building material s insulation properties are given as a U-Value, this must be a maximum of 1.4 W/m²K. List of suitable materials: Aerated concrete λ = 0.12-0.14 Vermiculite λ = 0.12-0.14 Calcium silicate λ = 0.09 Contact your chimney sweep for advice in choice of other materials. Remember that even a non-combustible wall may require protection if it is a load bearing wall or has combustible material behind it.

235 GB CHIMNEY 117 Chimney The stove is type approved in accordance with EN 13240 and the values obtained are presented in the Performance declaration, external diameter of the connection is Ø150 mm. The firebox requires a draft in the chimney of at least 12 Pa. The draft is affected both by the length and area of the chimney, and by how well sealed it is. Minimum recommended chimney length is 3.5 m and a suitable cross-sectional area is 150-200 cm 2 (Ø140-160 mm). Note that a flue with sharp bends and horizontal routing reduces the draught in the chimney. The maximum horizontal flue is 1 m, on the condition that the vertical flue length is at least 5 m. Carefully check that the chimney is sealed and that there is no leakage around soot hatches and flue connections. Make sure that the connector gasket does not work loose when the connection pipe is placed on the connector. If further sealing material is required, heat-resistant sealant may be used. It must be possible to sweep the full length of the flue and the soot hatches must be easily accessible. If two fireplaces are connected to the same chimney flue, the stove must be equipped with self-closing door, see insert instructions. Rearward connection If a protective screen is selected, this must be installed before making the chimney connection. For the rearward connection it is recommended to use a 45 +45 angle with soot hatch and with the centre 235 mm above the connector. Top connection Create an opening in the top grate by using the shorter grate profiles, see page 133. Cover the gap with a cuff.

118 SUPPLY Supply of combustion air Supply of combustion must be provided. Combustion air can be provided directly via a duct from outside, or indirectly via a vent in the outer wall of the room where the stove is placed. The amount of combustion air that is used for combustion is approx. 25 m 3 /h.! Some installation alternatives are shown below. The air duct connection on the stove has an external diameter of Ø100 mm. Turn the connector to ensure an air supply! In hot areas, the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor (aluminium tape). It is important that the lead-in, between the pipe and the wall (or floor), is sealed using jointing compound. A 1 m length of condensation-insulated ducting for combustion air is available as an accessory. HK Knockout To insert the combustion air hose through the floor panel, remove the knockout. HK HK 235 Supply down 130 255 Supply rear 75 HK

INSTALLATION DISTANCES 119 Installation distances C i51 Important! The dimension diagrams only show the minimum permitted installation distances for the stove. When connecting to a steel flue, also note the safety distance requirements of the flue. The minimum distance to combustible parts of the building or interior decoration in front of the stove must be at least 1.5 m. Combustible Brännbart roof tak 235 Min 2380 Ext. Utv. Ø Ø 150 150 510 920 1650 1135 1370 770 500! 700* 1085* For placement against combustible rear walls, a built-in protective screen (option in some markets), or an external firewall that protects the wall behind is required. Material requirements for firewalls according to the section Walls behind on page 116 *Optional protective screen, see separate instruction

VANADIUM GB 120 INSERT PLACEMENT 8 mm 8 8 No. 7 CHROME Allen screw 3 Allen screw 4 10 mm No. 7 CHROME 10 10 VANADIUM 13 mm 13 13 No. 7 CHROME VANADI UM PH2

10 GB INSERT PLACEMENT 121 Placement and adjustment of the insert PH2! If the protective screen is selected read these instructions before installing the insert or chimney. 1 10 VANADIUM No. 7 CHROME 10 mm 2 x 4 M6 x 20 Allen 10

122 INSERT PLACEMENT! The stove can be positioned tight to the wall behind. When installing against non-vertical walls and to facilitate installation it is recommended that a small gap is left between the wall and stove. Lay the floor section a slight distance from the wall behind, and align the position of the holes in the ceiling for the chimney lead-in with the same dimensions. 3 Min 1085* The cross in the floor panel indicates the location of the flue gas output. Position the floor section and check that the minimum permitted distance to combustible material is kept. Measure to the centre of the floor section. The rear edge of the floor section will align with the complete rear edge of the surround. *Optional protective screen, see separate instruction 4

VANADI UM GB INSERT PLACEMENT 123 5 6 min 505 13 mm Place a spirit level on the moulding below the door, adjust the feet until the smallest dimension from the floor to the underneath of the moulding is 505 mm all the way around. Move the spirit level to the sides and check that it is straight. 13 mm 13 13 No. 7 CHROME 715 mm Min 5 mm 7 Adjust the Mounting rails symmetrically around the insert according to the dimensions given. Check them using a spirit level.

124 INSERT PLACEMENT 8 PH2 9 The protective screen must be installed before the chimney.! Check that the transport locking device of the counterweight is removed according to the insert instructions before assembling the surround. With protective screen as option now connect according to separate instructions. Connect chimney upwards or rearwards, follow the chimney manufacturer's instructions. With Powerstone as option position the heat tank according to the insert s instructions. With combustion air hose as option now connect according to separate instructions.

~770 mm GB INSTALLATION OF SURROUND 125 Installation of surround Pre-installation of lower cover - section 1. 1 450 mm x 8 Nut M5 Tool 8 mm 2 x 6 Nut M5 Tool 8 mm 90 3 x 2 Nut M5 Tool 8 mm ~15 mm

126 INSTALLATION OF SURROUND Pre-installation of side panels - section 2 x 4 M6 x 16 Allen screw 4 x 6 M6 Tool 10 mm x 4 Spacers Pre-installation of upper cover - section 3 1 357 mm x 8 Nut M5 Tool 8 mm 2 90 x 2 M6 x 16 Allen screw 4 ~770 mm

INSTALLATION OF SURROUND 127 3 x 7 M6 Tool 10 mm x 7 M6 x 16 Allen screw 4 Pre-installation of upper cover - section 4 1 357 mm x 8 Nut M5 Tool 8 mm 2 90 ~770 mm x 2 M6 x 16 Allen screw 4

128 INSTALLATION OF SURROUND 3!! 4 x 8 M5 x 12 Allen screw 3 x 8 Nut M5 Tool 8 mm

INSTALLATION OF SURROUND 129 5 8 mm 6

130 INSTALLATION OF SURROUND 7 PH2 8 10 mm 410 mm!

INSTALLATION OF SURROUND 131 9 x 2 M6 x 20 Tool 10 mm 10

132 INSTALLATION OF SURROUND 11 12 ~ 4 mm x 2 M6 x 20 Allen screw 4

INSTALLING GRATE AND TOP 133 Assembling grate and top For rear connection x 2 M6 x 10 Allen screw 4 1 2

134 INSTALLING GRATE AND TOP 3 4! ~ 25 mm

INSTALLING GRATE AND TOP 135 For top connection 1 2 x 2 M6 x 10 Allen screw 4

136 INSTALLING GRATE AND TOP x 5 x 4 x 8 3 4

INSTALLING GRATE AND TOP 137 5! ~ 25 mm Disc base 1

~5 mm GB 138 INSTALLING GRATE AND TOP 2 Adjust the rubber feet on the disc base so that the gap up to the steel panels is 5 mm. Final inspection of the installation It is extremely important that the installation is inspected by an authorised inspection body before the stove is used. Also read the "Lighting instructions" before lighting for the first time.

NIBE AB Box 134 SE-285 23 Markaryd Sweden www.contura.eu 811269 IAV SE-EX Ci51 Plåt-4 2016-09-01 Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice. The current edition can be downloaded from www.contura.eu