Madison Water Utility Pressure Zone 4 Well Siting Study

Similar documents
Groundwater Master Plan Update: Emergency Groundwater Supply Analysis & Water Quality Discussion

Environmental Assessment. Appendix G Hazardous Materials Technical Report

ENVIRONMENTAL SUMMARY OF CATALYST AREA 1

Chapter DRINKING WATER

(this cover page left intentionally blank)

Title 26 DEPARTMENT OF THE ENVIRONMENT Subtitle 04 REGULATION OF WATER SUPPLY, SEWAGE DISPOSAL, AND SOLID WASTE

Livingston County Department of Public Health Environmental Health Division. Hydrogeologic Investigation Requirements for Land Division Developments

Enhanced Delivery of Potassium Permanganate Using Horizontal Wells

REQUEST FOR PROPOSAL Redevelopment Opportunity West Bend, Wisconsin

2014 Capital Improvement Project Contract Concrete Paving & Utilities Oshkosh, Wisconsin

Methodology for Identifying the Area of Concern Around a Property Potentially Impacted by Vapor Migration from Nearby Contaminated Sources

Green Remediation of Petroleum Contaminated Groundwater Using Oxygen Injection in Western Maine

FACTS ABOUT: Former GE Power Systems Apparatus Service Center (Voluntary Cleanup Program) Site Location

Prepared For: Town of Castle Valley, Utah

APPLICATION FOR A PERMIT TO CONSTRUCT A WATER WELL IN THE LOWER PLATTE NORTH NATURAL RESOURCES DISTRICT

New York State Department of Environmental Conservation August Receive Site Fact Sheets by . See "For More Information" to Learn How.

EXECUTIVE SUMMARY. The following is our conclusions of the environmental issues at the Site based on our investigations:

REGIONAL GROUND-WATER STUDY TOWN OF WOODBURY ORANGE COUNTY, NEW YORK INTRODUCTION

Environmental Resource Inventories. What are ERIs? Significance of information How to use them

LAFCO ANNEXATION TO JURUPA COMMUNITY SERVICES DISTRICT (TTM RIVERBEND)

WELL PERMIT APPLICATION

November 8, 2016 International Petroleum Environmental Conference. Tim Nickels Pastor, Behling & Wheeler, LLC

By Paul Robinson Research Director Southwest Research and Information Center PO Box 4524 Albuquerque, NM

Chapter 11: Hazardous Materials A. INTRODUCTION

2014 Plan of Conservation and Development. Municipal Infrastructure

Soil Vapor Migration Through Subsurface Utilities

Outfall at Lagoon between Lake of the Isles and Lake Calhoun

Source Water Assessment Program (SWAP) Report for Heath Elementary School

Wickes Manufacturing TCE Plume Site Mancelona, Michigan

Existing Land Use. Proposed

3.11 HAZARDOUS MATERIALS

The Use of A Horizontal Extraction Well In Conjunction with Air Stripping to Intercept A MTBE Plume and Protect a Municipal Water Supply Well

Reference Guideline #1. Hydrogeological Impact Assessment

LUST Site Corrective Action in Ozark Karst - Yellville, Arkansas

SAN MATEO PLAIN GROUNDWATER BASIN ASSESSMENT STAKEHOLDER WORKSHOP#2 SEPTEMBER 7, 2016

OSHA 40-Hour EPA-Approved Hazardous Waste Operations and Emergency Response Training

[THIS PAGE INTENTIONALLY LEFT BLANK]

Wellhead Protection Plan Unit Well 17

Why is protecting the groundwater so important?

Land Use Office, PO Box 197, 6683 County Road 13, Conejos CO Phone #: Fax:

FDEP Site Priority Scoring Guidance

Informational Meeting: Onsite and Offsite Response Action Plans

Section 3.11: Hazardous Materials

Locating Domestic Water Supply Wells: National, Regional and Local Scale

Tier 1 Vapor Migration Screening for Property Transactions Using ASTM E

MISSOURI DEPARTMENT OF NATURAL RESOURCES. Monitored Natural Attenuation of Groundwater Contamination at Voluntary Cleanup Program Sites

IV.ENVIRONMENTAL IMPACT ANALYSIS H. HAZARDOUS MATERIALS

Section 8 Minimum Horizontal and Vertical Setback Distances

ARTICLE 7. AQUIFER AND GROUNDWATER PROTECTION DISTRICT

APPENDIX K-2 IRP SITES

COMMUNITY FACILITIES ELEMENT

Application for On-Site Wastewater Treatment System Permit

Comparison State Policy Requirements, Proposed LAMP and Current County Regulations

ELDERBERRY CUSA EXPANSION SUMMARY INFORMATION

County of Wetaskiwin Pigeon Lake Watershed Area Concept Plan February 6, 2014

INFRASTRUCTURE ELEMENT SANITARY SEWER SUB-ELEMENT

Data Source: TCEQ Updated Evaluation for the North-Central Texas Trinity and Woodbine Aquifers, Priority Groundwater Management Study Area

Brownfield Redevelopment In Georgia Past, Present & Future. Presented by: Dan Grogan

Central New York Regional Site Profile Database CAYUGA, CORTLAND, MADISON, ONONDAGA & OSWEGO COUNTIES HISTORICAL ENVIRONMENTAL RECORDS REVIEW

PUBLIC POLICY FORUM February 22, 2005

ABBOTT SCHOOL DISTRICT ENVIRONMENTAL FEATURES FACT SHEET & LEGEND SYMBOL REFERENCE KEY

1 Exam Prep Chapter 64E -6 Questions and Answers

New Jersey Department of Environmental Protection Site Remediation Program

Case Studies in Risk Management Methods as a Component of the Remedial Process

TYPICAL CONTENTS OF A SITE-SPECIFIC NATURAL RESOURCE AND WOODLAND STAND DELINEATION MAP:

Application for Gas Exploration and Production

LONGHORN ARMY AMMUNITION PLANT TEXAS EPA ID# TX

Tylerville Center Water Supply Alternatives Evaluation

STATE OF DELAWARE DEPARTMENT OF NATURAL RESOURCES AND ENVIRONMENTAL CONTROL- SITE INVESTIGATION AND RESTORATION BRANCH

EPA REGION 6 U.S. CONGRESSIONAL DISTRICT 4 AIR FORCE PLANT 4 FORT WORTH, TARRANT COUNTY, TEXAS. EPA ID# TXD Site ID:

Source Water Assessment Program (SWAP) Report for Rowe Elementary School

patersongroup Phase I - Environmental Site Assessment Vacant Land, Strandherd Drive at Kennevale Drive Ottawa, Ontario Prepared For Regional Group

Guy Lavoie, C.E.T. Project Director

RURAL BASE ZONES. Zones Applicable to Land outside an Urban Growth Boundary

APPENDIX B. WSSC Design Criteria for Water Distribution Systems

How Groundwater Interacts with Lakes and Streams

Site Profiles - View. General Information. Contaminants: Site Name and Location: Description: Historical activity that resulted in contamination.

TOWN OF ENFIELD TIF DISTRICT BUILD OUT ANALYSIS

Midwest Technology Assistance Center Groundwater Resource Assessment for Small Communities

REGIONAL GROUND-WATER STUDY TOWN OF CHESTER ORANGE COUNTY, NEW YORK. Prepared For. Orange County Water Authority. June 1994

The Costs of NO Wellhead Protection. -- all cases from Maine

Lessons Learned from the Installation and Monitoring of a Permeable Reactive Barrier at the Lake City Army Ammunition Plant, Independence, MO

E. Domestic Wells. Introduction. Domestic Wells and the Water Law. Nevada Division of Water Planning

DEPARTMENT OF ENVIRONMENTAL QUALITY WATER QUALITY DIVISION PERMIT APPLICATION FORM UNDERGROUND INJECTION CONTROL (UIC) CLASS V WELL

2015 WELLHEAD PROTECTION PLAN Part 2

I-275 (State Road 93) Project Development & Environment Study

Additional criteria for approval of sanitary landfill facility permit to install applications.

D2 Project Environmental Remediation Briefing August 21, 2018

Brookhaven National Laboratory Source Water Assessment for Drinking Water Supply Wells

MARYLAND DEPARTMENT OF THE ENVIRONMENT

WATER SUPPLY ISSUES IN SOUTHEASTERN WISCONSIN: TECHNICAL AND POLICY NEEDS AND CHALLENGES

FINAL PLAN OF REMEDIAL ACTION

Chapter 5 Existing Wastewater Facilities

New York State Department of Environmental Conservation. Receive Site Fact Sheets by . See "For More Information" to Learn How.

UNIFORM DESIGN AND CONSTRUCTION STANDARDS FOR EXTENDING WATER DISTRIBUTION SYSTEMS SECTION 2 DESIGN STANDARDS

CHAMBERS CREEK REGIONAL WASTEWATER TREATMENT PLANT FACILITIES PLAN 4. POPULATION, FLOW, AND LOADING PROJECTIONS

Water and Wisconsin Agriculture: Reducing Withdrawals and Increasing Efficiency

BACKGROUND OFFSITE FACILITIES/RELEASE CASES

WALGREENS STORE #03425

ADVISORY OPINION IMPACT OF CREC FACILITY ON WATER SUPPLY & USE IN DISTRICT & WELL REMEDIATION DRAFT FOR PUBLIC REVIEW & COMMENT

Transcription:

Madison Water Utility Summary of Potential Well Sites March 24 2011 Site Status Comment 1 Dairy Center In consideration Several suitable properties in this area are available. 2 Tradewinds In consideration Several suitable properties in this area are avaialable. 3 Siggelkow Road Ruled out The site appears to be too close to a suspected inactive fault zone that may reduce the ability of the aquifer to provide sufficient quantities of water to the proposed well. 4 Progress Road Ruled out Available property is too small. Walton Commons Ruled out Land was purchased partly with federal funds and is dedicated to development as part of the Bioag Gateway. 6 North Dairy Center In consideration as an alternate to Dairy Center or Tradewinds At least one potentially suitable property in this area is available. I:\4131\Tables-General\[Site Comparison_110321.xls]Dairy Center

Madison Water Utility Unit Well 8 Lake Monona - Madison Water Utility Unit Well 23 Madison Water Utility Unit Well 9 Monona Well 1 Monona Well 2 Dairy Center Walton Commons Area Progress Road North Dairy Center Tanks 0 Tradewinds Center 600 ft setback Residential Fuel Oil Tank 200 ft setback Bulk Fuel Storage Facilities 1200 ft setback Landfills or Quarries 1200 ft setback LUST open activity City Owned Parcels Sanitary sewer main 0 Water main Municipal Well Notes: - Closed Remediation Sites with Contamination Remaining and Contaminated and Cleaned Up Sites downloaded from WDNR RR Sites Map on September 1 2010. McFarland 2 µ 0 1000 2000 McFarland 3 Data Sources: 00 Siggelkow Road Area Closed Remediation Sites with Contamination Remaining and Contaminated and Cleaned Up Sites are from the Wisconsin Department of Natural Resources WDNR Bureau for Remediation and Redevelopment Tracking System BRRTS ERP = Environmental Repair Program contaminated sites other than LUST LUST = Leaking Underground Storage Tank 1000 0 0 0 0-0 Parcels Soil Landfills and Quarries LUST closed activity Zone 4 Groundwater and Soil 1200 ft setback 0 Blooming Grove ERP open activity ERP open larger area activity Groundwater Contamination came from another property ERP closed larger area activity Closed Remediation Sites with Contamination Remaining ERP closed activity 0 Approved Gasoline or Fuel Oil Storage Tank - Contaminated and Cleaned Up Sites Ohmeda Site Contamination Legend 3000 4000 Feet Madison Water Utility Pressure Zone 4 Well Siting Factors McFarland 1

Madison Water Utility Dairy Center Summary March 24 2011 Status Background Primary Reason for Exclusion Advantages Disadvantages Site Buildability Contaminated Sites Summary In consideration This site was originally identified for evaluation because there are several undeveloped parcels in this area not immediately adjacent to identified known or potential sources of contamination. NA Relatively centrally located in southern portion of pressure zone. Within 1600 feet of a 16-inch water main through a partly-developed area. Properties in the area are for sale. The only documented groundwater contamination sites within 10 to 0 year zones of contribution ZOCs are limited to two properties with minor petroleum contamination plumes from leaking underground tanks that do not extend beyond the respective source properties. The 100 year ZOC intersects a 1200 foot radius two additional sites with residual petroleum contamination. Hydrogeologically down-gradient from the Ohmeda groundwater contamination plume Somewhat close to two sites closed with residual groundwater contamination None of the available sites are within the mapped 100-year floodplain. Portions of the properties on the lots on the east side of Dairy Drive abut or extend into mapped wetlands. A high pressure gas pipe in this area will likely require a minimum100-foot setback. Soils in the area have low to moderate bearing capacity and high water table. Four sites with groundwater contamination exceeding groundwater quality enforcement standards are shown on the Wisconsin Department of Natural Resources GIS system within the 100-year zone of contribution ZOC identified using the Dane County groundwater flow model. The contaminants of concern at all of these sites are petroleum related and do not appear to have migrated much beyond the boundaries of the source properties. Two additional sites with the 100-year ZOC are currently being investigated for petroleum contamination in groundwater. The Datex-Ohmeda site is currently under investigation for dissolved chlorinated solvents primarily trichloroethylene and related contaminants in groundwater. The plume extends at least as far as the existing Madison Water Utility property on Femrite Drive west of the interstate.

Legend for Contamination Maps: Contours on contamination maps labeled 10 R 0 R and 100 R show the estimated areas of the bedrock aquifer zones of contribution that contribute groundwater to a well at the example well location over period of 10 0 and 100 years at an average pumping rate for Madison water supply wells. These zones of contribution were estimated using the Dane County Regional Aquifer Flow Model developed cooperatively by the Wisconsin Geological and Natural History Survey and the United States Geological Survey.

Madison Water Utility Tradewinds Area Summary March 24 2011 Status Background Primary Reason for Exclusion Advantages Disadvantages In consideration This site was originally identified for evaluation because it is in a relatively large tract of undeveloped land not immediately adjacent to identified known or potential sources of contamination. NA Relatively centrally located in southern portion of pressure zone Within 3000 feet of a 16-inch water main through largely un-developed area Properties in the area are for sale Hydrogeologically down-gradient from the Ohmeda groundwater contamination plume Proposed lots 1 through in the Tradewinds Business Center may be within 600 feet of a 00 gallon gasoline aboveground storage tank at Franklin Fueling Systems on Marsh Road a NR 811 variance would be required for these lots. The 0 and 100 year zones of contribution ZOCs include the northern portion of the Terminal Drive/Triangle Street tank farms. Site Buildability Contaminated Sites Summary Several of the available proposed lots 3 through 7 14 1 and 16 in the Tradewinds Business Center area are currently with the mapped 100-year floodplain. Most of the proposed lots on the north side of Tradewinds Parkway are mapped as filled wetlands. Soils in the area have low to moderate bearing capacity and high water table. Nine sites with groundwater contamination exceeding groundwater quality enforcement standards are shown on the Wisconsin Department of Natural Resources GIS system within the 100-year zone of contribution ZOC identified using the Dane County groundwater flow model. The contaminants of concern at all of these sites are petroleum related and do not appear to have migrated much beyond the boundaries of the source properties. Eight additional sites with the 100-year ZOC are currently being investigated for petroleum contamination in groundwater. The Datex-Ohmeda site is currently under investigation for dissolved chlorinated solvents primarily trichloroethylene and related contaminants in groundwater. The plume extends at least as far as the existing Madison Water Utility property on Femrite Drive west of the interstate. Notes The quality of the fill soils in portions of the Tradewinds area will need to be evaluated for geotechnical properties and potential contamination on an individual site basis.

Madison Water Utility Siggelkow Road Area Summary March 24 2011 Status Background Primary Reason for Exclusion Ruled out This site was originally identified for evaluation because it did not appear to be downgradient from the former Ohmeda facility. The site appears to be too close to a suspected inactive fault zone that may reduce the ability of the aquifer to provide sufficient quantities of water to the proposed well. Advantages Located far from the existing unit well 9 Unlikely to be impacted by contamination from former Ohmeda facility Preliminary work did not identify potential contamination sources within the 100 year zone of contribution ZOC which is mostly rural; however 7 percent of ZOC was not included in initial contamination assessment. Disadvantages Appears to be very close to a suspected inactive fault zone. Poor well yields were documented at the former Town of Blooming Grove Well and at the ahara Golf Course. Relatively close to McFarland well 3 Much of surrounding area and zone of contribution is not within Madison corporate limits and not is controlled by Madison zoning. Availability of property within existing Madison boundaries is very limited The only significant undeveloped tract is a Madison city park. The nearby water mains are 12 inches or less in diameter. The closest 16 main is approximately 800 feet away by road. Notes Details for McFarland Well 3: 700 feet deep 260 feet of casing; static 49 feet 1200 gpm at 218 feet specific capacity of 7.1 gpm/ft.

Madison Water Utility Progress Road Summary March 24 2011 Status Background Primary Reason for Exclusion Ruled out This site was originally identified for evaluation because there is at least one un-developed parcel in the area not immediately adjacent to identified known or potential sources of contamination. Available property is too small. Advantages Relatively centrally located in Pressure Zone 4 Disadvantages Hydrogeologically down-gradient from the Ohmeda groundwater contamination plume during portions of the year The nearby water mains are 12 inches or less in diameter. The closest 16 main is approximately 4000 feet away by road. Limited available land. Undeveloped parcel size of 1 acre is sub-optimal.

Walton Commons Area Summary March 24 2011 Madison Water Utility Status Background Primary Reason for Exclusion Ruled out This site was originally identified for evaluation because is undeveloped city-owned property. Land was purchased partly with federal funds and is dedicated to development as part of the Bioag Gateway. Advantages Relatively close to the boundary of Pressure Zone 6 Within 300 feet of a 16-inch water main City-owned property Disadvantages City-owned property is dedicated for bio-ag development and would be very difficult to re-purpose for municipal services. Hydrogeologically down-gradient from the Ohmeda groundwater contamination plume

Madison Water Utility North Dairy Center Summary March 24 2011 Status Background Primary Reason for Exclusion Advantages Disadvantages Site Buildability Contaminated Sites Summary In consideration as an alternate to Dairy Center or Tradewinds This site was identified as an alternate for evaluation because there is at least one available undeveloped parcel in this area that may be suitable as a well location. This area was added for consideration after potential limitations were identified on sites in the Dairy Center south and Tradewinds areas. NA Relatively centrally located in southern portion of pressure zone. Within 100 to 00 feet of a 16-inch water main. At least one property in the area is for sale. Relatively close to three sites closed with residual groundwater contamination and one active site with petroleum and solvent contamination in groundwater. Variance would be required for proximity to active underground storage tank systems. The area is not within the mapped 100-year floodplain. Soils in the area have low to moderate bearing capacity and high water table. Three sites with groundwater contamination exceeding groundwater quality enforcement standards are shown on the Wisconsin Department of Natural Resources GIS system within the 100-year zone of contribution ZOC identified using the Dane County groundwater flow model. The contaminants of concern at all of these sites are petroleum related and do not appear to have migrated much beyond the boundaries of the source properties. Two inactive landfills are located within the 0-year ZOC. The former Safety-Kleen facility on Daniels Street is currently under investigation for petroleum contamination and solvents in soil and groundwater. The Datex-Ohmeda site is currently under investigation for dissolved chlorinated solvents primarily trichloroethylene and related contaminants in groundwater. The plume extends at least as far as the existing Madison Water Utility property on Femrite Drive.