No-loss soil corer for soil with volatile components

Similar documents
Evaporation pan. Meet the difference. Manual. T E I

These conditions must be maintained during transport to the laboratory.

Liquid layer sampler, cable operated

OPERATIONAL MEMO GEN-14 Revision 3. November, Volatile Organic Compound (VOC) Sediment Sampling Method 5035 Field Sampling Procedure

RBC flume. All it takes for environmental research. Contents. 1. Introduction. 2. The flumes of Eijkelkamp Agrisearch Equipment

RBC Flume Meet the difference. User manual

ASSEMBLY & USER INSTRUCTIONS - UBETRACK MOBILE STORAGE SYSTEM. version 1.0 EN 3

09.04 double ring infiltrometer

BIOSCAN* ATP method for monitoring of biofilm/sessile microorganisms in cooling systems

Soil sampling protocol for monitoring changes in soil carbon stocks in Amazonia

STANDARD OPERATING PROCEDURES

Contact Information: Laboratory Supervisor: Denise Kind Laboratory Manager: Mat Ashby

FIELD PROCEDURE: TURBIDITY

Direct-Push Soil and Groundwater Sample Collection (Geoprobe ) (pg. 23) Calculation of Purge Volumes for Groundwater Sampling Wells (pg.

Best Practices for Collecting Soil Samples for VOC Analysis

THERMAL ISOLATION CLIP

VARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model

VARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model

U. S. EPA ENVIRONMENTAL RESPONSE TEAM

INSTALLATION INSTRUCTIONS

Why change is inevitable in aseptic manufacturing?

Best Practices for Collecting Soil Samples for VOC Analysis

CLASSIFICATION OF FIRE RESISTANCE PERFORMANCE IN ACCORDANCE WITH EN : 2007

ASSEMBLY & USER INSTRUCTIONS - UBETRACK MOBILE STORAGE SYSTEM

Sampling-system Simplex 2600

STE portable hardness tester

BALLISTIC RESISTANT PLASTER ON CMU

Our bags are manufactured from sealable materials and are designed to provide the maximum protection for your products: Gastight Water vapor barrier

Australian Standard. Atmospheric corrosivity zones in Australia AS AS

INSTALLATION INSTRUCTIONS NOFIRNO SEALING SYSTEM FOR MULTI-PIPE TRANSITS

Super Clean Gas Filters Simply the best

High Temperature Aging Cell Instruction Manual

VWR CO 2 RESISTANT TUBES

STANDARD OPERATING PROCEDURE FOR SPRING AND SEEP SAMPLING

Design and Construction of Landfill Gas Monitoring Wells

OWNERS MANUAL FOR WATER FILTER JUG

Trinic H12 Sealer Mixing & Application

STANDARD OPERATING PROCEDURE FOR SOIL, SEDIMENT, AND SOLID WASTE SAMPLING

Pipe to Manhole Connectors, Sealants. Pipe to Manhole Connectors, Sealants

COPY. Region4 U.S. Environmental Protection Agency Science and Ecosystem Support Division Athens, Georgia

Technical Data Sheet EPOXY PRIMER 3:1 Anti-corrosion epoxy primer RELATED PRODUCTS. Epoxy primer hardener EPOXY PRIMER HARDENER PROPERTIES

DRAFT UGANDA STANDARD

General Service Butterfly Valves. Series 120, 140, 160, 300

User Manual Dialysis probe

4 1 /2 MARK 73-5 AMERICAN FLOW CONTROL. It s What We Know. AMERICAN-DARLING FIRE HYDRANT AMERICAN-DARLING 4 1 /2 MARK 73-5 FIRE HYDRANT

Diaphragm seal with threaded connection Threaded design Model

ST XX28 Stainless Steel Thermostatically Controlled Electric Model

DRAFT UGANDA STANDARD

Best Practices for Collecting Soil Samples for VOC Analysis

SOIL SALINITY / CONDUCTIVITY METERS

2.1 This procedure provides steps and conditions for the determination of Vapor Space Organic Compounds in ground waters, and industrial waste waters.

AVK 26 AVK UK Water Mains to Meter Offer & Price List 2017

PLANT ROOT SAMPLING P1.32. The root auger is pushed into the soil from the surface by simply turning and pushing downward at the same time.

WATER SAMPLING INSTRUCTIONS READ CAREFULLY AND COMPLETELY BEFORE SAMPLE COLLECTION Call the laboratory if you have questions.

Best Practices for Collecting Soil Samples for VOC Analysis. David Kaminski - QED Environmental Systems Inc. Dave Turriff - En Novative Technologies

Straight Panel Bath Screen Instruction Manual

NH3 Sampling Protocol Using The Ogawa Sampler*

INTERNATIONAL STANDARD

This is a protocol that is designed to support the citizen

HOLE SAMPLING & MONITORING. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD

SUPER FRESHNESS METER KV-202. Instruction Manual

CONTACTS. Environmental Health and Safety. Regulated Materials Management Center

Solvita Compost Emissions Test

Technical Bulletin No. MK3176. PREPARED: July, 2010

23, SEDIMENT COLLECTIONS

Best Practices for Collecting Soil Samples for VOC Analysis. David Kaminski - QED Environmental Systems Inc. Dave Turriff - En Novative Technologies

12 Temperature measurement SCT analogue

Screw Cap Micro Tubes

fusion shower pan on wood joists installation guide

CSULB Department of Biological Sciences Common Use Equipment Training. Autoclaves

POLYESTER INJECTION MORTAR Good Quality and Competitve Price

Installation, Operating & Maintenance Instructions For Tri-Tech Medical Sleep Lab Panel Series

Super Clean Gas Filters Simply the best

ST 19 Aluminium Manually Controlled Electric Model

Immersion Assembly for ph and Redox Sensors DipFit P CPA 140

Quick Reference Guide. Supplies for CTC GC and HPLC Autosamplers

Contact: To sterilize or decontaminate uniformly, superheated steam must contact all areas of the load.

Australian/New Zealand Standard

Exterior Wall Solutions Building Shell

J ~~the following information: media type (soil cuttings and so forth), sampling location (well ID, Earth & Environmental

PF-DETERMINATION (SANDBOX METHOD)

LymTal International, Inc.

Effective Use of Autoclaves

CAULKING INSTRUCTIONS GRABBERGARD EFC & IFC

ATECO TANK TECHNOLOGIES ENGINEERING CO.LTD. ALUMINIUM HONEYCOMB FULL-CONTACT TYPE ULTIMATE DESIGN SUPERIOR STRUCTURE.

ST 19 T Aluminium Thermostatically Controlled Electric Model

Keystone Figure 412/418 Butterfly valve handles

Surface Soil Sampling

Parabond 600 Elastic glue and adhesive with extremely high initial bonding

Sight glasses. Feedthroughs ISO-KF. Installation elements

SAFE WORK PROCEDURE LOCATION WRITTEN BY: APPROVED BY: DATE CREATED LAST REVISION. Schools in PTSD Lorie Carriere School Principal August 30, 2011 New

THE LOGISTIC SOLUTION

Project drains. Project drains. Floor/Bathroom drains. Shower channels. Basement drains. Drains and channels in stainless steel. Exterior installation

SOP BIO-006 USE OF AUTOCLAVE FOR STERILIZATION OF MATERIALS AND BIOLOGICAL WASTE

CONA -Universal / CONA -Connector

Title: Standard Operating Procedure for Sample Collection Using Tedlar Bags and Adsorbent Tubes

Flow Assembly for ph and Redox Sensors FlowFit P CPA 240

Part 4: Prefilled syringes

Automatic TLC Sampler 4

Forensic DNA Fingerprinting

Transcription:

P.O. Box 4, 6987 ZG Giesbeek, The Netherlands T +31 313 88 02 00 E info@eijkelkamp.com I www.eijkelkamp.com No-loss soil corer for soil with volatile components User manual Parts of the set: Soil corer, plunger, stand with push pin, coring rings, bags, stickers and jars (bar-coded stickers optional available via the laboratory) Working principle: Handle Soil corer Sideways movement scrapes off excess soil to 16 ml Plunger Stainless steel soil coring ring 16ml~25 gram About this manual This manual shows: 1. Cooling or freezing method 2. Methanol or sodiumthiosulphate method Details on these methods can be found in US-EPA 5035A-2002 (very detailed on both methods) or revisions of ISO standards as ISO 22155 (ready spring 2010) and ISO 15009 (end 2010). In ISO 18512 the methanol method is described especially. Meet the difference 2016 M.04.10.E

This manual does not show safety measure as these may vary according to local laws and site conditions. Contact the laboratory before taking samples. They can supply you with bar-code stickers. Consult the lab on how they like to receive the samples for dry weight determination. Dry weight determination can be done on a second (marked) coring ring or on soil in a larger jar. On this larger sample other analysis on non-volatile components may be executed also. 1. Cooling or freezing method Clean the inside of the soil corer with a tissue. If necessary decontaminate / sterilize sampler with soldering gun flame The coring ring may be clicked in the sampler before or after the decontamination, provided that the coring ring is clean. Fill in sticker(s) provided with the set and/or the stickers from the laboratory Mark ticket boxes ( ) with Chemical Analyses OR with Dry weight (dry weight if applicable) In some countries it is allowed to report with a default (average) soil moisture percentage, a separate determination of dry weight is not necessary then. Put the stickers on the bags Take a large sample from soil at sufficient depth (e.g. 1 meter) with any sampler (shown here: Dutch auger). Sampling at insufficient depth results in a sample with a non-representative quantity of volatiles Remove any smeared soil from outside of main sample Push the soil corer into the larger sample. Overfill. Push a second time if the soil is very sticky. 2

Use a hammer for filling if the soil is hard or sticky In stony soils some damage of the cutting edge cannot be excluded. Small damages may be corrected with a file. Push cutting ring sideways out of coring device. Soil volume in coring ring will now become 16 ml. Clean ring edges to obtain air-tight closure with caps Push caps in place. The seals in the caps are diffusion proof because of an aluminium layer. To prevent any corrosion the aluminium is coated with PET at the sample side. PET resists most volatiles. Put the capped coring ring in the bag with sticker and store it in the cooler* or freezer. * cooling is sufficient for a storage time of some days (48 hours before extraction in the lab). When freezing, a period of max. 2 weeks is advised. Depending on the standard(s). Take a duplicate** sample to allow the lab to express the concentrations measured as based on dry weight Repeat the procedure above but now mark dry weight. ** Duplicate not necessary if concentrations can be reported on an as received basis so without moisture correction. 3

Overview of working site. Samples ready for cooling or freezing Push out remaining excess soil with plunger to prepare sampler to hold a new coring ring. It is advised to have an extra sampler and plunger in the lab in order to keep the field and lab equipment separated It is also possible to place the entire coring with sample in the jar In the lab: Remove the caps by cutting the side of each cap with a utility knife ( Stanley knife ) and place coring ring in the sampler. Sample is pushed in a special 100 ml glass jar with the plunger. Note: The entire filled coring ring can be put in the jar also. This seems attractive for loose soils (that will fall out of the ring easily). There has been no research yet, proving that extraction goes quick enough when a heavy soil is collected in the ring. 4

2. Methanol or sodiumthiosulphate method Remove and clean the coring ring (tissue) or take a clean one. Remove any loose soil out of the soil corer with the plunger and a tissue. Especially clean the rims where the ring is clicked in (clean with screw driver) Click the coring ring in the sampler Decontaminate / sterilize sampler with soldering gun flame (shown) Put jar ready, pre-filled with 25 grams of methanol or sodiumthiosulphate (for low concentrations). See US-EPA 5035A-2002 guideline or consult the laboratory. Fill in sticker(s) as supplied in the set or from the lab: Mark ticket boxes ( ) with Chemical Analyses OR with Dry weight (dry weight if applicable) Take a large sample from soil at sufficient depth (e.g. 1 meter) with any sampler (shown here: Dutch auger). Sampling at insufficient depth results in a sample with a non-representative quantity volatiles Remove any smeared soil from outside of main sample Push the soil corer into the larger sample. Overfill. Push a second time if the soil is very sticky. 5

Use a hammer for filling if the soil is hard In stony soils some damage of the cutting edge cannot be excluded. Small damages may be corrected with a file. Push coring ring sideways out of coring device using the stand with push pin. Soil volume in coring ring will now become 16 ml. Coring ring removed. Excess soil still in sampler body Push out remaining soil from sampler with the plunger. Clean the chamber in which the ring was clicked (with a screw driver). Click the coring ring, filled with 16 ml of soil back in sampler body. It is also possible to put the entire filled coring ring (without the caps!) in the jar with methanol or sodiumthiosulphate. Consult the laboratory on what to do with the rings. Re-using the rings is possible, but may be more expensive based on cleaning and logistics than using new ones. 6

Use the plunger to push the 16 ml of soil in the jar with methanol or sodiumthiosulphate. Cap the jar and put it in the bag with sticker(s). Store the jar prior to transport. Be sure it cannot break during transport. Take a duplicate** sample to allow the lab to express the concentrations measured as based on dry weight ** Duplicate not necessary if concentrations can be reported on an as received basis so without dry weight determination. Dry weight can also be determined on a sample in a larger jar (eg for analysis on non-volatiles). Naturally the soil moisture percentage must be the same as the sample on volatiles. Take the sample in a coring ring and remove the coring ring from the sampler as shown earlier. Clean ring edges to obtain air-tight closure with caps Push caps in place. Stick the filled in sticker(s) marked dry weight on the bag, put the capped coring ring in the bag and store for transport. Nothing in this publication may be reproduced and/or made public by means of print, photocopy, microfilm or any other means without previous written permission from Eijkelkamp Soil & Water. Technical data can be amended without prior notification. Eijkelkamp Soil & Water is not responsible for (personal damage due to (improper) use of the product. Eijkelkamp Soil & Water is interested in your reactions and remarks about its products and operating instructions. 7