Principles of Gel Filtration Chromatography

Similar documents
Principles of Gel Filtration Chromatography

Principles and Practice of Agarose Gel Electrophoresis

Students will predict the net movement of molecules across a semipermeable membrane.

The Biotechnology Education Company. Affinity Chromatography of Glucose Binding Protein. Storage: See Page 3 for specific storage instructions

Module 16: Gel filtration: Principle, Methodology & applications. Dr. Savita Yadav Professor Department of Biophysics AIIMS, New Delhi

SAMPLE LITERATURE Please refer to included weblink for correct version.

Gel Filtration Chromatography. Teaching Kit Manual. GeNei TM. Cat No. New Cat No. KT Revision No.:

MOLECULAR MIXTURES Using Size Exclusion Column Chromatography For Molecular Separation

Biology 2180 Laboratory # 4 Name. Size Exclusion Chromatography and Microconcentration

Clinical Diagnostic Immunoblot. Storage: Store the entire experiment in the refrigerator. EXPERIMENT OBJECTIVES:

Electroelution. Teachers Handbook. (Cat. # BE 602) think proteins! think G-Biosciences

Part 3 Separation of Complex Protein Mixtures into Individual Components

Experiment 2: The Chromatography of Organic Compounds

Lesson 2 Inoculation Growing a Cell Culture

The Biotechnology Education Company. Quantitative ELISA. Storage: See Page 3 for specific storage instructions EXPERIMENT OBJECTIVE:

Materials & Equipment 400 ml SDS running buffer Molecular weight markers (MWM) Chromatography samples (A476-1, A476 peak, A476+1)

Hydrophobic Chromatography

S-45. What Size Are Your Genes? Edvo-Kit #S-45. Experiment Objective: See page 3 for storage instructions.

Antigen-Antibody Interaction: The Ouchterlony Procedure. Storage: Some components require refrigerator storage. See page 3 for storage requirements.

Cu (s) Cu 2+ (aq) Cu(OH) 2 (s) CuO (s) Cu 2+ (aq) Cu (s)

Experiment 3: The Chromatography of Organic Compounds

TEACHER GUIDE MOLECULAR MIXTURES Molecular separation using size exclusion column chromatography

Making Saline SOLUTION. Lab Number 2 Part 1

A Rapid, Simple & Inexpensive Experiment in Gel Filtration Chromatography

AGAROSE GEL ELECTROPHORESIS Modified from Wolbachia FIBR Project, Rochester University

Laboratory 8B Dialysis

Ion exchange chromatography

Plasmid DNA Isolation Column Kit Instruction Manual Catalog No. SA-40012: 50 reactions SA-40011: 100 reactions

The Biotechnology Education Company. Single Antibody ELISA Diagnostics. Storage: See Page 3 for specific storage instructions EXPERIMENT OBJECTIVE:

ELECTROPHORESIS OF SPOOLED DNA 1 An Introduction to Agarose (Horizontal) Electrophoresis

Lab 8: Bacterial Transformation with pglo for Protein Production

Isolation of Protein

Sephacryl S-100, S-200, S-300, S-400, S-500 High Resolution

Table of contents. p. 2

Product # Specifications. Kit Specifications Column Binding Capacity. 10 g Maximum Weight of Gel Slice Average DNA Recovery 70 90%

Size Exclusion Chromatography

EXPERIMENT 7A. Chemical Separation by Filtration and Recrystallization INTRODUCTION

Biotechnology Explorer

The Biotechnology Education Company. Isolation of E. coli Chromosomal DNA. Storage: See Page 3 for specific storage instructions

TECHNICAL BULLETIN. HIS-Select HF Nickel Affinity Gel. Catalog Number H0537 Storage Temperature 2 8 C

Pre-Lab Exercises Lab 8: Biochemistry

Sequencing Reaction Clean-Up Kit Product # 34500

A. Introduction. Figure 1 Figure 2

Introduction. Background Information PRINCIPLES OF GEL ELECTROPHORESIS

(Refer Slide Time: 00:16)

Announcements. Next week s discussion will have a quiz on Chapter 3fg and Chapter 11ab Computer Lab (Chapter 11ab): 10/17 10/22

Electrophoresis 101 MiniLab

Protein Folding Study

Basic Biotechnology Kit

BASIC ELECTROPHORESIS

ITS Sequencing in Millepora. 10/09 Subcloning DNA Fragments into pbluescript Preparation of pbluescript Vector

Wearing gloves is highly recommended when handling the kit contents.

PURPOSE: To separate the pigments of spinach by Column Chromatography. To analyze Column Chromatography fractions by Thin Layer Chromatography.

Protein Techniques 1 APPENDIX TO CHAPTER 5

3. Close the bottom end of the column and apply the packing device on top. Pump water through the upper adaptor to remove air.

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised November 2015

E.Z.N.A. Stool DNA Kit. D preps D preps D preps

E.Z.N.A. FFPE RNA Kit. R preps R preps R preps

Experiment: Acetylation of Ferrocene

Protein-Pak Hi Res HIC Column and HIC Protein Standard

EXPERIMENT 5 Chemistry 110 COMPOSITION OF A MIXTURE

Lysis Buffer A Wash Solution A Elution Buffer B Mini Filter Spin Columns 50 Collection Tubes 50 Elution tubes (1.7 ml) 100 Product Insert 1

MD60002 MD MD62002

Ion Exchange Chromatography. Teaching Kit Manual. GeNei TM. Cat No. New Cat No. KT Revision No.:

foodproof Sample Preparation Kit III

An Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+

Ni-NTA Agarose H A N D B O O K. Ni-NTA Agarose NP ml Ni-NTA Agarose NP ml Ni-NTA Agarose NP ml

Biotechnology In Your Mouth

Purification of mfp. from an Overnight Culture. Laboratory 17

ADVANCED ELECTROPHORESIS

Bacterial Transformation: Unlocking the Mysteries of Genetic Material

Transformation of E. coli with pbr322

Investigating Photosynthesis Using Algal Balls

E.Z.N.A. Stool DNA Kit. D preps D preps D preps

ProteoSpin Total Protein Concentration, Detergent Clean-Up and Endotoxin Removal Mini Kit Product Insert Product # 22800

Glutathione Agarose Resin User s Guide

The Biotechnology Education Company. Western Blot Analysis. Storage: See Page 3 for specific storage instructions EXPERIMENT OBJECTIVE:

3. Procedure Outline. Make sure you have an explanation for every step in your procedure outline.

HiTrap Desalting, 5 ml

Your complete protein clean-up toolbox

LABORATORY 1.2: GEL ELECTROPHORESIS

Experiment 1: DNA Isolation from Plant and Animal Tissue and Gel Electrophoresis. Amber Broadbooks, Adrienne Martinez, Quenton Sayles

Downstream Processing Prof. Mukesh Doble Department of Biotechnology Indian Institute of Technology, Madras. Lecture - 29 Chromatography (continued)

Human DNA Alu Amplification by Polymerase Chain Reaction (PCR)* Laboratory Procedure

BIOLOGY 163 LABORATORY. RESTRICTION MAPPING OF PLASMID DNA (Revised Fall 2017)

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised January 2017

Urine DNA Isolation Maxi Kit (Slurry Format) Product # 50100

1 ml gel corresponds to ml of 75% (v/v) Glutathione Agarose suspension.

Lecture 25: Introduction to Chromatography and Gel Filtration

Molecular Methods in Microbial Ecology

BIOC 463A Expt. 4: Column Chromatographic Methods Column Chromatography

Userguide: SepFast Gel Filtration columns

In Search of the "Kissing Disease"

E.Z.N.A. Yeast RNA Kit. R preps R preps

Gel Electrophoresis and Analysis

E.Z.N.A. Bacterial RNA Kit. R preps R preps

SERVA BluePrep Protein EndotoxinEx Macro Kit

Urine DNA Isolation Kit Dx (Slurry Format)

Transcription:

EDVOTEK P.O. Box 1232 West Bethesda, MD 20827-1232 The Biotechnology Principles of Gel Filtration Chromatography 108 EDVO-Kit # Storage: Store entire experiment at room temperature. Experiment Objective: To introduce the principles of gel filtration chromatography as a method that separates molecules according to their size and shape. A mixture of two molecules are separated in this experiment. 1-800-EDVOTEK (301) 251-5990 24-hour FAX: (301) 340-0582 http://www.edvotek.com email: edvotek@aol.com All components are intended for educational research only. They are not to be used for diagnostic or drug purposes, nor administered to or consumed by humans or animals. 31

2 EDVO-Kit # 108: Principles of Gel Filtration Chromatography Major Section Headings None of the experiment components have been prepared from human sources. Page Experiment Components 2 Requirements 2 Background Information 3 Experimental Procedures 5 Study Questions 7 Instructor's Guide Pre-Lab Preparations 9 Expected Results 10 Answers to Study Questions 10 Experiment Components Storage: Store entire experiment at room temperature. All components of this experiment are intended for educational research only. They are not to be used for diagnostic or drug purposes, nor administered to or consumed by humans or animals. Enough reagents and sample are provided for 10 separations. A B C Contents Sample Mixture Dry Matrix Concentrated Elution Buffer 20 Plastic Transfer Pipets 90 Plastic microtest tubes with attached caps 10 Chromatography Columns Requirements Ten 50 ml or 100 ml beakers or flasks 1 small beaker or flask (10 or 25 ml) or a 10 ml test tube 1 ring stand with clamp for each column Distilled or deionized water (Distilled water available in supermarkets is of suitable quality) 5 or 10 ml pipets and pipet pumps (optional) document, or any part, may not be reproduced or distributed for any other 32 purpose without the written consent of EDVOTEK, Inc.

EDVO-Kit # 108: Principles of Gel Filtration Chromatography 3 BACKGROUND INFORMATION Principles of Gel Filtration Chromatography Gel filtration chromatography (sometimes referred to as molecular sieve chromatography) is a method that separates molecules according to their size and shape. The separation of the components in the sample mixture, with some exceptions, correlates with their molecular weights. In these cases, gel filtration can be used as an analytical method to determine the molecular weight of an uncharacterized molecule. Gel filtration is also an important preparative technique since it is often a chromatographic step in the purification of proteins, polysaccharides and nucleic acids. The basic components of the gel filtration experiment are the matrix, chromatography column and the elution buffer. The matrix is the material in the column that is actually the separation medium. It is the stationary phase of the chromatography. The column is a tube with a frit and elution spout fitted at the bottom. The frit is a membrane or porous disk that supports and retains the matrix in the column but allows water and dissolved solutes to pass. The elution buffer is the mobile phase of the chromatography and flows through the matrix and out of the column. The column, with the matrix and applied sample, is developed by the elution buffer. This means that the molecules in the sample are carried by the flow of buffer into the matrix where they are gradually separated. The separated zones of molecules then flow out of the column where they are collected for analysis. Concentration Void Volume 1 2 Elution Volume 3 Filling the chromatography column with matrix is referred to as packing. The packed matrix is called the bed and the volume it occupies is termed the bed volume. 4 Bed Volume 5 It is very important not to allow the bed to run dry. Otherwise, cracks and fissures develop and the matrix has to be removed and repacked. The gel filtration matrix consists of microscopic beads that contain pores and internal channels. The larger the molecule, the more difficult it is for it to pass through the pores and penetrate the beads. Larger molecules tend to flow around and in between the beads. The total volume of buffer between the beads document, or any part, may not be reproduced or distributed for any 33 other purpose without the written consent of EDVOTEK, Inc.

4 EDVO-Kit # 108: Principles of Gel Filtration Chromatography BACKGROUND INFORMATION Background Information, continued is the void volume. Smaller molecules tend to spend more time in the maze of channels and pores in the bed. Consequently, the larger, higher molecular weight molecules are eluted from the column before smaller molecules. Larger molecules take the faster, more direct path that involves less time in the beads. This is somewhat analogous to finding your way out of a complicated maze or simply walking around the outside of the maze and avoiding the whole situation entirely. Molecules can have the same molecular weight but radically different shapes. Molecules with a more compact shape, such as a sphere, will penetrate the beads more easily than those having an elongated shape, like a rod. Therefore, a rod-like molecule will elute before a spherical one of the same molecular weight. There are many different types of gel filtration matrices. The spectrum of molecular weights the matrix is capable of separating is called the fractionation range. For example, consider a matrix that has a fractionation range (in molecular weight) of 1000 to 100,000 daltons. Molecules with an average molecular weight of 1000 or less will not be separated from each other since they all penetrate the beads completely and with equal efficiency. These molecules take the maximum volume of buffer for elution, which is equal to one bed volume. The bed volume is equal to the volume of the beads plus the void volume. Molecules in the range of 1000 to 100,000 daltons will enter the beads with varying efficiencies and be partially or completely separated from one another. Molecules greater than 100,000 daltons will not enter the beads and be eluted in the void volume. Note that in this example, any number of different molecules having molecular weights of 100,000 daltons or greater will all elute at the same time since they are not sieved by the matrix. The partially or completely separated zones of molecules that are eluted from the column are called peaks. A peak consists of an increasing and decreasing concentration gradient of molecules. This experiment includes columns which will be pre-packed with the appropriate matrix for separation of the sample mixture. The sample in this experiment contains a mixture of orange and blue molecules. The orange dye has a molecular weight of 452. The blue is a polymer of glucose with an average molecular weight of 2,000,000 daltons, and has a rod-like shape. The fractionation range of the matrix is 1000 to 5000 daltons. document, or any part, may not be reproduced or distributed for any other 34 purpose without the written consent of EDVOTEK, Inc.

EDVO-Kit # 108: Principles of Gel Filtration Chromatography 5 EXPERIMENTAL PROCEDURES EXPERIMENT OBJECTIVE: To introduce the principles of gel filtration chromatography as a method that separates molecules according to their size and shape. A mixture of two different molecules will be separated in this experiment. LABORATORY SAFETY Gloves and goggles should be worn routinely as good laboratory practice. Chromatography: Packing the Column Quick Reference: Reservoir filled with buffer 1. Mix the matrix thoroughly by swirling or gently stirring. 2. With a 5 or 10 ml pipet, carefully pipet all of the mixed slurry into the column by letting it stream down the inside walls of the reservoir or pour the slurry into the column. If the flow of matrix is stopped by an air pocket, stop pouring and firmly tap the column until the air is removed and the slurry flows down. Continue pouring the rest of the slurry. 3. With a transfer pipet, add elution buffer to fill the reservoir. Packed bed 4. Place an empty beaker under the column. 5. Remove the cap from the spout of the column. 6. Let the buffer flow through the column for approximately 10 minutes. The matrix will pack down into the column. Frit Eluant spout of column 7. Place the cap onto the spout of the column. 8. The matrix is packed when it stops compressing. The volume of the packed bed will be approximately 3 ml. Optional Stopping Point #1 If time is limited, the experiment can be temporarily stopped here. The columns must be securely closed so they do not run dry. If you are stopping the experiment here, make sure there is buffer above the bed and the reservoir is covered with plastic wrap or parafilm. document, or any part, may not be reproduced or distributed for any 35 other purpose without the written consent of EDVOTEK, Inc.

6 EDVO-Kit # 108: Principles of Gel Filtration Chromatography EXPERIMENTAL PROCEDURES Chromatography: Fraction Collection 1. Label 8 test tubes 1-8. Put your initials or lab group number on all the tubes. 2. Carefully remove all the buffer from above the bed with a transfer pipet. The top of the bed should be exposed to air. WEAR SAFETY GOGGLES AND GLOVES Insert a pipet through the reservoir. Try to minimize disturbance of the bed while removing buffer. 3. Load the contents of the Sample tube (x) onto the top of the bed with a transfer pipet. Let the sample drip down the inside walls of the column. Remember! Do not let the column run dry! 4. Place a beaker under the column. 5. Remove the cap from the spout. The sample will slowly enter the bed. When it has completely entered the bed (the top of the bed will be exposed to air), replace the cap. 6. Carefully add several drops of buffer over the bed with a transfer pipet. Open the cap and allow the buffer to enter the column. 7. Continue adding buffer, several drops at a time, pausing to allow the buffer to enter the bed. 8. When the blue dye reaches near the bottom of the column, begin to collect 0.5 ml fractions. Hold tube #1 directly under the column. (The tubes are graduated to help you measure 0.5 ml.) 9. As the dyes gradually separate in the column, periodically add fresh buffer to the reservoir to keep it full. 10. Continue collecting 0.5 ml fractions in each of the 2-8 tubes. 11. After all tubes of column effluent (column fractions) have been collected, replace the cap onto the spout. 12. Identify the tube with the greatest amount of blue dextran that eluted from the column. 13. Identify the tube that has the greatest amount of orange dye that eluted from the column. document, or any part, may not be reproduced or distributed for any other 36 purpose without the written consent of EDVOTEK, Inc.

Edvotek 108 Study Questions Name: 1. In one sentence, describe how gel filtration chromatography works to separate molecules. 2. Outline the basic steps involved in setting up and running a gel filtration column. 3. Define the following terms: matrix frit elution buffer packing the column void volume 4. Why do larger molecular weight molecules elute from the column faster than smaller molecular weight molecules? 5. What is meant by the stationary phase and the mobile phase when discussing chromatography? 6. How does the shape of a molecule influence how quickly it will elute? 7. What is the fractionation range of a particular gel? 37