BOILER/HEATER < 5 MMBTU BACT Size: Small Emitter BACT (PTE < 10 lb/day) BOILER. BACT Determination Information

Similar documents
BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION

BOILER/HEATER > 5 MMBTU BACT Size: MINOR SOURCE BACT BOILER. BACT Determination Information

BACT Determination Information

BACT Determination Information

BEST AVAILABLE CONTROL TECHNOLOGY & TOXIC BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION

BACT Determination Information

TANK/PIPELINE DEGASSING SYSTEM BACT Size: Minor Source BACT THERMAL OXIDIZING UNIT - PORTABLE. BACT Determination Information

BACT Determination Information

BEST AVAILABLE CONTROL TECHNOLOGY & TOXIC BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION

BACT Determination Information

BACT Determination Information

BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION

BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION

PHARMACEUTICAL PROCESS BACT Size: Uncontrolled Emissions > 467 lb/year PHARM MANUF. BACT Determination Information

PORTABLE CONCRETE/ASPHALT RECY BACT Size: Minor Source BACT Crusher, Screen, Transfer & Storage. BACT Determination Information

SACRAMENTO METROPOLITAN AIR QUALITY MANAGEMENT DISTRICT. Board of Directors Sacramento Metropolitan Air Quality Management District

BACT Determination Information

PHARMACEUTICAL PROCESS BACT Size: Minor Source BACT PHARM MANUFACTURING OPERATIONS. BACT Determination Information

BACT Determination Information

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT DRAFT STAFF REPORT

Statement of Reasons Rules 414 and 419 September 24, 2018 Page 2 TABLE OF CONTENTS

SANTA BARBARA COUNTY AIR POLLUTION CONTROL DISTRICT POLICIES AND PROCEDURES. Policy No Draft Div Pol Yr

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT DRAFT STAFF REPORT

SANTA BARBARA COUNTY AIR POLLUTION CONTROL DISTRICT

TITLE V OPERATING PERMIT STATEMENT OF BASIS

BACT Determination Information

BACT Determination Information

United States Environmental Protection Agency, Region 9. Air Division. Technical Support Document. for. EPA s Notice of Proposed Rulemaking.

TITLE V OPERATING PERMIT STATEMENT OF BASIS

BACT Determination Information

VENTURA COUNTY APCD STAFF REPORT Amendments to Rule Boilers, Steam Generators and Process Heaters June 23, 2015 EXECUTIVE SUMMARY

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT SAN JOAQUIN VALLEY AIR POLLUTION CONTROL DISTRICT FINAL STAFF REPORT

PROPOSED AMENDMENTS TO RULE 2.27, BOILERS DRAFT STAFF REPORT

BACT Determination Information

BACT Determination Information

APPENDIX C SCAQMD PERMIT APPLICATION

Table of Contents. (a) APPLICABILITY (b) EXEMPTIONS (c) DEFINITIONS... 2

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT. Guideline for Expedited Application Review (GEAR) #20 Existing Chain-Driven Charbroilers

CHAPTER 4 EMISSION CONTROL MEASURES

UC Davis Air Quality Program. Aimee Pfohl, EH&S

~ SWCAA. Q~;r;!{~ Paul T. Mairose Chief Engineer. Southwest Clean Air Agency. December 22, 2017

State of the Art (SOTA) Manual for Stationary Gas Turbines

FINAL DETERMINATION. To Grant a. Temporary Permit/Non-Attainment New Source Review Permit. For. Concord Steam Corporation.

BACT Determination Information

PART C - POLICY AND PROCEDURES FOR NON-MAJOR POLLUTING FACILITIES

COATING - PLEASURE CRAFT BACT Size: Minor Source BACT COATING OPERATION. BACT Determination Information

BACT Determination Information

NOx Reduction: Flue Gas Recirculation vs Selective Catalytic Reduction. Presented by Jason Jacobi October 28, 2015

SACRAMENTO METROPOLITAN AIR QUALITY MANAGEMENT DISTRICT EXPEDITED BARCT IMPLEMENTATION SCHEDULE FOR ASSEMBLY BILL 617.

Table of Contents. (a) APPLICABILITY... 1 (b) EXEMPTIONS... 1 (c) DEFINITIONS... 1 (d) STANDARDS... 2

Sacramento Regional 8-Hour Ozone Attainment Revised August 25, 2011 and Reasonable Further Progress Plan March 26, 2009

San Joaquin Valley Unified Air Pollution Control District. Best Performance Standard (BPS) x.x.xx. Process Heaters. Thermal Fluid Heat Transfer System

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT FINAL DRAFT STAFF REPORT

GASP comments regarding Air Quality Plan Approval C - Tenaska Pennsylvania Partners, LLC Westmoreland Generating Station

Table of Contents. (a) APPLICABILITY... 1 (b) EXEMPTIONS... 1 (c) DEFINITIONS... 1 (d) STANDARDS... 2

ENGINEERING CALCULATION SHEET AIR RESOURCES DIVISION

DRAFT AUTHORITY TO CONSTRUCT

REDUCTION OF NO x EMISSIONS FROM NATURAL-GAS- FIRED, FAN-TYPE CENTRAL FURNACES

SACRAMENTO METROPOLITAN AIR QUALITY MANAGEMENT DISTRICT

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT FINAL DRAFT STAFF REPORT

09/30/2010 Waterside Power Redline Version: Matt Lydon Formatted: Font: Bold, Italic Formatted: Font: Bold, Italic Draft Model Rule Control of Natural

State of New Hampshire Department of Environmental Services Air Resources Division. Temporary Permit

San Joaquin Valley Unified Air Pollution Control District Best Performance Standard (BPS) x.x.xx

San Joaquin Valley Unified Air Pollution Control District Best Performance Standard (BPS) x.x.xx

DRAFT PROPOSED PERMIT. San Diego County Air Pollution Control District Old Grove Rd San Diego, CA (858)

San Diego County Air Pollution Control District Old Grove Rd San Diego, CA (858)

Oklahoma Gas & Electric

New Source Review Staff Presentation Community Advisory Council

State Implementation Plans for Federal 8-Hour Ozone and PM2.5 Standards San Joaquin Valley Eastern Kern County

DRAFT AUTHORITY TO CONSTRUCT

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT. Appendix C: EPA Documents November 15, 2011

Air Pollution Control Permitting - Customer Overview

Appendix I. Candidate Control Measures Ozone Plan

2006 Area Source Emissions Inventory Methodology 670 NON-AGRICULTURAL OPEN BURNING

Chapter 3. Demonstration of Federal Clean Air Act Requirements. PROPOSED 2016 Moderate Area Plan for the 2012 PM2.5 Standard

2006 Area Source Emissions Inventory Methodology 020 COGENERATION - NG

Title V. Model General Permit Template SERIES 1 FLARES. Template # SJV-FL-1-1

NOx Emissions from Boilers and Heaters

Offsets Presentation Community Advisory Council

San Joaquin Valley Unified Air Pollution Control District Best Performance Standard (BPS) x.x.xx

Chapter 4. Attainment Strategy for PM2.5

San Joaquin Valley Unified Air Pollution Control District

RECOMMENDED CPCN CONDITIONS CASE NO CATOCTIN POWER, LLC

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT DRAFT STAFF REPORT. Annual Offset Equivalency Demonstration.

Title V. Model General Permit Template SERIES 3 INTERAL COMBUSTION ENGINES. Template # SJV-IC-3-1

Rule BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (OXIDES OF NITROGEN)

Re: Proposed ATC / Certificate of Conformity (Significant Mod) District Facility # N-1976 Project # N

Power-Cost Alternative De-NOx Solutions for Coal-Fired Power Plants

Public Workshop on Developing Expedited BARCT Implementation Schedule

Notice of Intent Application

Prevention of Significant Deterioration (PSD) Permitting. Scoping Meeting

San Joaquin Valley Unified Air Pollution Control District Best Performance Standard (BPS) x.x.xx

Regulating Stationary Sources RECLAIM Cap & Trade Program

[Facility Name] Facility ID [Facility ID] Toxics Emissions Inventory Plan

Emission Inventory EMISSIONS INVENTORY DEVELOPMENT IN CALIFORNIA. Presentation Outline 9/30/2015

Wyodak Power Plant. Chapter 6, Section 2 Construction Permit Application. Submitted to the Wyoming Air Quality Division And Prepared by

San Joaquin Valley Air Pollution Control District APR 1010 Application Review Format

Protect AQ & public health. Governing Board: Large, complex region: 9 counties / 101 cities > 7 million people > 5 million vehicles

AIR REGULATION IN SOUTH CAROLINA 3 JUNE 2016

SHASTA COUNTY DEPARTMENT OF RESOURCE MANAGEMENT AIR QUALITY MANAGEMENT DISTRICT

Transcription:

DRAFT SMAQMD CLEARINGHOUSE CATEGORY: BOILER/HEATER < 5 MMBTU Size: Small Emitter (PTE < 10 lb/day) BOILER Determination Number: 136 Determination Date: 1/25/2017 Equipment Information Permit Number: N/A -- Generic Determination Equipment BOILER Unit Size/Rating/Capacity: >= 75,000 Btu/hr and < 2.0 MMBtu/hr fired on NG Equipment Location: ROCs NOx SOx PM10 PM2.5 CO LEAD Determination Information Good Combustion Practices 20ppm or pool/spa heaters < 400,000Btu/hr = 55ppm Low NOx burner with good combustion practices Good Combustion Practices Good Combustion Practices Good Combustion Practices 400 ppm Low NOx burner with good combustion practices Comments: All units listed ppm are ppmvd corrected to 3% O2 District Contact: Printed: 1/26/2017 Joe Carle Phone No.: (916) 874-4838 email: jcarle@airquality.org

777 12 th Street, Third Floor Sacramento, CA 95814 BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION DETERMINATION NO.: 136 DATE: 1/25/2017 ENGINEER: Joe Carle Category/General Equip Equipment Specific Equipment Size/Rating: Boiler/Heater Natural gas Boiler/heater greater or equal to 75,000 BTU/hr and less than 2.0 MMBTU/hr, fired on natural gas Small Emitter (PTE < 10 lb/day) Previous Det. No.: 112 This determination will update Determination #112 for boilers/heaters greater or equal to 75,000 BTU/hr and less than 2.0 MMBtu/hr, fired on natural gas. ANALYSIS A: ACHIEVED IN PRACTICE (Rule 202, 205.1a) The following control technologies are currently employed as for boilers/heaters greater or equal to 75,000 BTU/hr and less than 2.0 MMBTU/hr fueled by natural gas by the following air pollution control districts: Best Available Control ()/Requirements Source: EPA RACT//LAER Clearinghouse US EPA VOC N/A No determinations found in the 0.075 to <2 MMBtu/hr range NOx N/A No determinations found in the 0.075 to <2 MMBtu/hr range SOx N/A No determinations found in the 0.075 to <2 MMBtu/hr range PM10 N/A No determinations found in the 0.075 to <2 MMBtu/hr range PM2.5 N/A No determinations found in the 0.075 to <2 MMBtu/hr range CO N/A No determinations found in the 0.075 to <2 MMBtu/hr range None Template Version 071315

Page 2 of 9 Best Available Control ()/Requirements Source: ARB Clearinghouse ARB VOC N/A No determinations found in the 0.075 to <2 MMBtu/hr range NOx N/A No determinations found in the 0.075 to <2 MMBtu/hr range SOx N/A No determinations found in the 0.075 to <2 MMBtu/hr range PM10 N/A No determinations found in the 0.075 to <2 MMBtu/hr range PM2.5 N/A No determinations found in the 0.075 to <2 MMBtu/hr range CO N/A No determinations found in the 0.075 to <2 MMBtu/hr range None SMAQMD Source: SMAQMD #112 VOC Good combustion practice; Use of natural gas or LPG if natural gas is not available. NOx Pool/spa heaters: 55 ppmvd at 3% O 2 All other boilers/heaters: 20 ppmvd at 3% O2 SOx Good combustion practice; Use of natural gas or LPG if natural gas is not available. PM10 Good combustion practice; Use of natural gas or LPG if natural gas is not available. PM2.5 Good combustion practice; Use of natural gas or LPG if natural gas is not available. CO 400 ppmvd at 3% O 2, Burner technology controlling NOx as a priority Rule 414 - Water Heaters, Boilers And Process Heaters Rated Less Than 1,000,000 BTU Per Hour For units with a rating of 75,000 Btu/hr to < 400,000 Btu/hr Pool/Spa Heater 55 ppmvd of NOx corrected to 3% O 2 All others 20 ppmvd of NOx corrected to 3% O 2 For units with a rating of 400,000 Btu/hr to < 1 MMBtu/hr 20 ppmvd of NOx corrected to 3% O 2 400 ppmvd of CO corrected to 3% O 2 Rule 411 - NOx from Boilers, Process Heaters and Steam Generators For units with a rating of 1 MMBtu/hr to < 2 MMBtu/hr 30 ppmvd of NOx corrected to 3% O 2 400 ppmvd of CO corrected to 3% O 2

Page 3 of 9 Best Available Control ()/Requirements Source: SCAQMD Guidelines for Non-Major Polluting Facilities Note: SCAQMD Guidelines do not contain a determination for boilers/heaters 2 MMBtu/hr or less, since these units are not required to obtain a written permit, pursuant to SCAQMD Rule 219. SCAQMD Rule 219(b)(2) Written permits are not required for boilers, process heaters, or any combustion equipment that has a rated maximum heat input capacity of 2,000,000 Btu per hour (gross) or less and are equipped to be heated exclusively with natural gas, methanol, liquefied petroleum gas, or any combination thereof. VOC N/A No determinations found in the 0.075 to <2 MMBtu/hr range NOx N/A No determinations found in the 0.075 to <2 MMBtu/hr range SOx N/A No determinations found in the 0.075 to <2 MMBtu/hr range PM10 N/A No determinations found in the 0.075 to <2 MMBtu/hr range PM2.5 N/A No determinations found in the 0.075 to <2 MMBtu/hr range CO N/A No determinations found in the 0.075 to <2 MMBtu/hr range South Coast AQMD Reg XI, Rule 1146.2 Emissions of Oxides of Nitrogen from Large Water Heaters and Small Boilers and Process Heaters Category NOx Limit CO Limit Type 1 Unit (except pool heaters) Type 1 Unit (pool heater) Type 2 Unit 14 nanograms per joule of heat output (20 ppmvd @ 3% O 2 ) 40 nanograms per joule of heat output (55 ppmvd NOx @3% O 2 ) 14 nanograms per joule of heat output (20 ppmvd @ 3% O 2 ) Units manufactured for use or offered for sale after No standard January 1, 2012 No standard January 1, 2001 400 ppmvd @ 3% O 2 January 1, 2010 (A) TYPE 1 UNIT means any water heater, boiler or process heater with a RATED HEAT INPUT CAPACITY less than or equal to 400,000 BTU per hour excluding TANK TYPE WATER HEATERS subject to the limits of District Rule 1121. (B) TYPE 2 UNIT means any water heater, boiler or process heater with a RATED HEAT INPUT CAPACITY greater than 400,000 BTU per hour up to and including 2,000,000 BTU per hour.

Page 4 of 9 Best Available Control ()/Requirements Source: NSR Requirements for Note: SDCAPCD Guidelines do not contain a determination for boilers/heaters 5 MMBtu/hr or less, since these units are not required to obtain a written permit, pursuant to SDAPCD Rule 11. SDAPCD Rule 11(d) Any equipment, operation, or process that is listed below in Subsections (d)(1) through (d)(20), and that meets the stated exemption provision, parameter, requirement, or limitation, is exempt from the requirements of Rule 10. (d)(2)(v) Any boiler, process heater, or steam generator with a manufacturer s maximum gross heat input rating of less than 5 million BTU per hour fired exclusively with natural gas and/or liquefied petroleum gas. San Diego County APCD VOC N/A No determinations found in the 0.075 to <2 MMBtu/hr range NOx N/A No determinations found in the 0.075 to <2 MMBtu/hr range SOx N/A No determinations found in the 0.075 to <2 MMBtu/hr range PM10 N/A No determinations found in the 0.075 to <2 MMBtu/hr range PM2.5 N/A No determinations found in the 0.075 to <2 MMBtu/hr range CO N/A No determinations found in the 0.075 to <2 MMBtu/hr range Regulation 4, Rule 69.2.1 Small Boilers, Process Heaters, and Steam Generators Emission Limits (Effective on or after March 25, 2010) Type of equipment and size, in MMBtu/hr Units 0.6 and 2.0, except as below, fired on gaseous fuel Units 0.6 and 2.0, except as below, fired on liquid fuel NOx ppmvd CO ppmvd 30 400 40 400 Units < 0.6 Rule not applicable Rule not applicable (A) This rule does not apply to waste heat recovery boilers (B) This rule does not apply to Furnaces, kilns, and any combustion equipment where the material being heated is in direct contact with the products of combustion. (C) This rule does not apply to thermal oxidizers and associated waste heat recovery equipment.

Page 5 of 9 Best Available Control ()/Requirements Source: BAAQMD Guideline Note: BAAQMD Guidelines do not contain a determination for boilers/heaters 10 MMBtu/hr or less fired exclusively on natural gas or LPG, since these units are not required to obtain a written permit, pursuant to BAAQMD Regulation 2, Rule 1. BAAQMD Rule 2-1-114 The following equipment is exempt from the, requirements of Sections 2-1-301 and 302 (requirement to obtain an ATC or PTO): (114.1) Boilers, Heaters, Steam Generators, Duct Burners, and Similar Combustion Equipment: 1.2 Any of the above equipment with less than 10 million BTU per hour rated heat input if fired exclusively with natural gas (including compressed natural gas), liquefied petroleum gas (e.g. propane, butane, isobutane, propylene, butylenes, and their mixtures), or any combination thereof. Bay Area AQMD VOC N/A No determinations found in the 0.075 to <2 MMBtu/hr range NOx N/A No determinations found in the 0.075 to <2 MMBtu/hr range SOx N/A No determinations found in the 0.075 to <2 MMBtu/hr range PM10 N/A No determinations found in the 0.075 to <2 MMBtu/hr range PM2.5 N/A No determinations found in the 0.075 to <2 MMBtu/hr range CO N/A No determinations found in the 0.075 to <2 MMBtu/hr range BAAQMD Reg 9, Rule 6 Nitrogen Oxide Emissions from Natural Gas-fired Boilers and Water Heaters Type of unit Emission Limits (Effective January 1, 2013) Size of Unit in Btu/hr NOx Limit in nanograms per joule of heat output (ppmvd @ 3% O2) Pool/spa heater 75,001 to 400,000 No standard Pool/spa heater 400,001 to 2,000,000 14 (20) Other boilers/heaters 75,001 to 2,000,000 14 (20)

Page 6 of 9 Best Available Control ()/Requirements Source: SJVUAPCD Guideline Note: SJVUAPCD Guidelines do not contain a determination for boilers 5 MMBtu/hr or less, since these units are not required to obtain a written permit, pursuant to SJUVAPCD Rule 2020. SJVUAPCD Rule 2020 6.0 No Authority to Construct or Permit to Operate shall be required for ( 6.1) steam generators, steam superheaters, water boilers, water heaters, steam cleaners, and closed indirect heat transfer systems that have a maximum input heat rating of 5,000,000 Btu per hour (gross) or less and is equipped to be fired exclusively with ( 6.1.1.1) natural gas, ( 6.1.1.2) liquefied petroleum gas, or ( 6.1.1.3) any combination of the two. VOC N/A No determinations found in the 0.075 to <2 MMBtu/hr range NOx N/A No determinations found in the 0.075 to <2 MMBtu/hr range SOx N/A No determinations found in the 0.075 to <2 MMBtu/hr range PM10 N/A No determinations found in the 0.075 to <2 MMBtu/hr range PM2.5 N/A No determinations found in the 0.075 to <2 MMBtu/hr range CO N/A No determinations found in the 0.075 to <2 MMBtu/hr range San Joaquin Valley APCD SJVUAPCD Rule 4308 Boilers, Steam Generators, and Process Heaters 0.075 MMBtu/hr to less than 2.0 MMBtu/hr Emission Limits (Effective on or after January 1, 2015) Type and Size of Unit, in MMBtu/hr Units 0.075 and 0.4, except as below Units > 0.4 and < 2.0, except as below Instantaneous water heaters 0.075 and 0.4 Instantaneous water heaters >0.4 and <2.0 NOx Limit (corrected to 3% O2) PUC Gas lb/mmbtu of heat input (ppmvd) Non-PUC Gas or Liquid lb/mmbtu of heat input (ppmvd) 0.024 (20) 0.093 (77) 0.024 (20) 0.036 (30) 0.024 (20) 0.093 (77) 0.024 (20) 0.036 (30) Pool heaters 0.075 and 0.4 0.068 (55) 0.093 (77) Pool heaters > 0.4 and < 2.0 0.024 (20) 0.036 (30) For units with a rating of 0.4 MMBtu/hr and < 2.0 MMBtu/hr: 400 ppmvd of CO corrected to 3% O 2

Page 7 of 9 The following control technologies have been identified and are ranked based on stringency: SUMMARY OF ACHIEVED IN PRACTICE CONTROL TECHNOLOGIES VOC 1.Good combustion practices [SMAQMD ()] 2.No standard [SCAQMD, SJVUAPCD, SDCAPCD, BAAQMD] NOx 1. Pool/spa heaters < 400,000 Btu/hr: 55 ppmvd at 3% O 2 All other boilers/heaters: 20 ppmvd at 3% O 2 - [SMAQMD, SCAQMD, SJVUAPCD] 2. Pool/spa heaters < 400,000 Btu/hr: no standard All other boilers/heaters: 20 ppmvd at 3% O 2 - [BAAQMD] 3. Boilers/heaters < 600,000 Btu/hr: no standard All other boilers/heaters: 20 ppmvd at 3% O 2 [SDCAPCD] SOx 1.Good combustion practices [SMAQMD ()] 2.No standard [SCAQMD, SJVUAPCD, SDCAPCD, BAAQMD] PM10 1.Good combustion practices [SMAQMD ()] 2.No standard [SCAQMD, SJVUAPCD, SDCAPCD, BAAQMD] PM2.5 1.Good combustion practices [SMAQMD ()] 2.No standard [SCAQMD, SJVUAPCD, SDCAPCD, BAAQMD] CO 1.400 ppmvd at 3% - [SMAQMD ()] 2.Boilers/heaters < 400,000 Btu/hr: no standard All other boilers/heaters: 400 ppmvd at 3% O 2 [SCAQMD, SJVUAPCD] 3.Boilers/heaters < 600,000 Btu/hr: no standard All other boilers/heaters: 400 ppmvd at 3% O 2 [SDCAPCD] 4.No standard [BAAQMD] The following control technologies have been identified as the most stringent, achieved in practice control technologies: BEST CONTROL TECHNOLOGIES ACHIEVED Pollutant Standard Source VOC Good combustion practices SMAQMD (current ) NOx Pool/spa heaters < 400,000 Btu/hr: 55 ppmvd at 3% O 2 All other boilers/heaters: 20 ppmvd at 3% O 2 SMAQMD (Rule 414), SDCAPCD (Rule 4308), SCAQMD (Rule 1146.2) SOx Good combustion practices SMAQMD (current ) PM10 Good combustion practices SMAQMD (current ) PM2.5 Good combustion practices SMAQMD (current ) CO 400 ppmvd at 3% O 2 SMAQMD (current ) B. TECHNOLOGICALLY FEASIBLE AND COST EFFECTIVE (Rule 202, 205.1.b.): Technologically Feasible Alternatives: Any alternative basic equipment, fuel, process, emission control device or technique, singly or in combination, determined to be technologically feasible by the Air Pollution Control Officer. The table below shows the technologically feasible alternatives identified as capable of reducing emissions beyond the levels determined to be Achieved in Practice as per Rule 202, 205.1.a.

Page 8 of 9 VOC NOx SOx PM10 PM2.5 CO No other technologically feasible option identified 1. Selective Catalytic Reduction (SCR) 2. Flue Gas Recirculation (FGR) with a Low-NOx burner No other technologically feasible option identified No other technologically feasible option identified No other technologically feasible option identified No other technologically feasible option identified Cost Effective Determination After identifying the technologically feasible control options, a cost analysis is performed to take into consideration economic impacts for all technologically feasible controls identified. Maximum Cost per Ton of Air Pollutants Controlled A control technology is considered to be cost-effective if the cost of controlling one ton of that air pollutant is less than the limits specified below (except coating operations): Pollutant Maximum Cost ($/ton) ROG 17,500 NO X 24,500 PM 10 11,400 SO X 18,300 CO TBD if triggered SCR: Typically selective catalytic reduction (SCR) can be used to reduce emissions from larger boilers. SCR requires ammonia or urea for NOx reduction and units of this size range are typically used in residences and service/commercial applications where storage of these materials is impractical and could pose a health risk. Additionally, SCR is designed for industrial units that run full time and can maintain a temperature that the catalyst requires for NOx reduction, whereas smaller units are turned on and off throughout the day and cannot maintain the required temperatures. Finally, SCR systems require frequent maintenance for operation which may not be practical in a residential or small service/commercial setting. District Staff has done an analysis 1 for using SCR on a boiler rated at 20 MMBTU/hr and the cost effectiveness was $53,084 per ton of NOx reduced. As the rating of the unit goes down the total emission reduction will decrease while cost will stay relatively equivalent and therefore the cost effectiveness will increase. Therefore, SCR is not only technologically infeasible for this size range of boilers/heaters but it is also not cost effective and is eliminated as a control option. FGR with a Low-NOx Burner: Adding FGR to a smaller unit would result in minimal additional reductions when paired with a low- NOx burner, and would cost more than a low-nox burner alone. Like SCR, the system requires frequent maintenance for operation which may not be practical in a residential or small service/commercial setting. The BAAQMD did an analysis of adding FGR to a boiler in the 400,000 to 2,000,000 Btu/hr range in their 2007 Staff Report for Regulation 9, Rule 6 and found that the 1 SMAQMD, Determination: Boilers/Heaters 5 and <20 MMBTU/hr fired on natural gas or LPG, June 3,2015

Page 9 of 9 incremental cost effectiveness of adding FGR over a low-nox burner is estimated at $60,000 per ton of NOx reduced. Therefore, FGR added to a boiler/heater with a low-nox burner is not cost effective and is eliminated as a control option. C. SELECTION OF : Because no other technically feasible alternatives are available for the size range of these boilers/heaters for VOC, SOx, PM10, PM2.5 and CO will remain at what is currently achieved in practice. Currently what is in SMAQMD Rule 412 and other district rules are more stringent than the current standard by limiting the size range of pool/spa heaters that can fall under the 55 ppmvd emission limit. for Boilers/Heaters 75,000 Btu/hr and < 2.0 MMBtu/hr Fired on Natural Gas Pollutant Standard Source VOC Good combustion practices SMAQMD (current ) NOx SMAQMD (Rule 414), Pool/spa heaters < 400,000 Btu/hr: 55 ppmvd at 3% O 2 SDCAPCD (Rule 4308), All other boilers/heaters: 20 ppmvd at 3% O 2 SCAQMD (Rule 1146.2) SOx Good combustion practices SMAQMD (current ) PM10 Good combustion practices SMAQMD (current ) PM2.5 Good combustion practices SMAQMD (current ) CO 400 ppmvd at 3% O 2 SMAQMD (current ) D. SELECTION OF T-: Toxics are in the form of VOCs and particulate matter. Since toxic emission from natural gas fired boilers in the 2 MMBtu/hr or less size range are so small and the cancer risk is not expected to be anywhere close to 1 in a million cases, T- was not evaluated for this determination. REVIEWED BY: DATE: APPROVED BY: DATE: