Installation. Basic Rack Power Distribution Units AP9560 AP9561

Similar documents
Rack Power Distribution Unit AP7562, AP7563, AP7564 General Information

NetShelter. Four-Post Rack. Installation and Quick-Start Manual

APC Step-Down Transformer. Models: AP9626, AP9627, and AP9628

Smart-UPS X-Series External Battery Pack Installation and Operation

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Smart Distribution Panel with ATS Unpacking Instructions

Building Management Integration Card

J60 Lithium Ion UPS 350VA Model User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

E-Series Installing E-Series U Cabinet

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

SelfCheck System R-Series. Site Planning Guide

Saphyr System Safety Guide for Saphyr P/N 60325

INSTALLATION & OPERATION INSTRUCTIONS ICW-3 WINDOW INTERCOM

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

General Safety Information

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz

OptoLum MegaLine RGBW Luminaire

S70 Line Interactive Tower UPS

Model T2642E Wall Mount. Television Wall Mount with Tilt Option

MANUAL. ENGLISH Antenna Booster Ordercode: D1425. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Dynatronics Parallel Bars

OPTO BRANCH 6 RJ45. user manual. ELATION OPTO BRANCH 6 RJ45 user manual

DMX-BRANCH/4. user manual. ELATION DMX-BRANCH/4 user manual

Quick Start Guide WaveMaster

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

P1902 Installation Manual

DUST FREE ACTIVE Total Home Air Purification

STEEL PIPE NIPPLES SEAMLESS Price Sheet PNS-9.16C Effective: September 5, 2016 Cancels Price Sheet PNS-10.15C of October 5, 2015

AIRSTREAM DMX BRIDGE. User Instructions

WARRANTY AND SERVICE POLICY

New Advanced Environmental Air Treatment System

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

SAVE THESE INSTRUCTIONS

MTTC User Manual. Innovative Technology for a Connected World. General Description. Specifications and features

Global Water Instrumentation, Inc.

4-Wire Buffer Amplifier. User Manual

INSTALLATION INSTRUCTIONS

DJ Switch 10F V2 ORDERCODE 50365

Thermoelectric Cooler

Global Water Instrumentation, Inc.

Daniel Orifice Fittings and Meter Tubes

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. MPL Digital Pedestal. Manual Version 0.2

INSTALLATION PROCEDURE

Global Water Instrumentation, Inc.

J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL

Infant Warmer Care Station Cabinet Light

Agilent 16047D Test Fixture

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

66-Bin Wire Shelf Storage Rack

DLB-23 Shower Enclosure Installation and User s guide

E3X-DRT21/SRT21/CIF11

Agilent 16048D Test Leads

User Guide M Rev A 09/15

Carbon Canister Vapor Polisher

OPTO BRANCH 8. ELATION OPTO BRANCH 8 user manual 1.0

New Advanced Environmental Air Treatment System

OM-CP-QUADPROCESS 4-Channel Low Level DC Current Data Logger. OM-CP-OCTPROCESS 8-Channel Low Level DC Current Data Logger INSTRUCTION SHEET

Continuous Wave Single Frequency Lasers. SCHERZO Series. 532nm 300mW

117-Bin Wire Shelf Storage Rack

Table of contents. 1. Introduction

FLARING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

Continuous Wave Single Frequency Lasers. SYMPHONY Series. 532nm 2000mW

Instructions for Use Reusable Electrophysiology Catheter Cables

Agilent 16034E Test Fixture

Maintenance Bypass Breaker Cabinet Series Configuration 2. Installation and Operation Manual

Daniel TM Ultrasonic Flow Meters

Agilent 16048B Test Leads Operating Note Third Edition Agilent Part No May 2000

WARNING. Introduction ! ATTENTION

Atlona VGA over CAT5 Extender w/stereo Audio and RS-232

Documentation. Transient voltage suppressor - AX2090- TS Version: Date:

Adjustable Fused Power Supply

Ecologix Environmental Systems, LLC

Pallet Puller. Owner s Manual

Introduction TMD Warnings and Cautions Caution: Caution: Caution: Caution: Caution: Caution: Modification

Installation and Operation Manual

3M SelfCheck System V-Series Kiosk. Site Planning Guide

SPECIAL SPECIFICATION 1184 Testing, Training, Documentation, Final Acceptance, and Warranty

4 rotary milling table

Instructions for Use Reusable Ablation Catheter Cables

Introduction Specifications Control Panel / Remote Unit Diagrams Setting Up the Unit Maintaining the Unit Safety info / Warnings Warranty Information

Xxxxx Xxxxxx OM-CP-TEMP101A. Temperature Data Logger with 10 year battery life INSTRUCTION SHEET MQS5026/0117

REUSABLE TOOL UNU-USB

Shower Column SHCM Installation Guide

Instructions for Use Reprocessed Electrophysiology Catheter Cables

KNHE20 SERIES WATER-TO-AIR HEAT EXCHANGER

EP100 EMERGENCY POWER BANK

Y SIDE ALUMINUM TRUCK RACK

CDM Network Programmer for CCT100x

NOTICE: To the prices and terms quoted, there will be added any manufacturers or sales tax payable on the transaction under any effective statute.

EP-CORKEL2 OWNER S MANUAL

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: SWM-1 Loudspeaker Wall Mount Device. P/N: Rev 1

NOTICE: To the prices and terms quoted, there will be added any manufacturers or sales tax payable on the transaction under any effective statute.

UNIVERSAL UTILITY TRUCK RACK

Instructions and E00 Series Sampling Module Extenders

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

H8SX/1650 Series E6000H TFP-120 User System Interface Board User s Manual HS1650ECN61H

Transcription:

Installation Basic Rack Power Distribution Units AP9560 AP9561

Contents Preliminary Information...................1 AP9560...........................1 AP9561...........................1 Safety and Grounding....................2 Installation.............................3 Horizontal mounting.................3 Vertical mounting...................4 Specifications...........................5 Warranty and Service....................6 Limited warranty....................6 Warranty limitations..................6 Obtaining service....................6 Life-Support Policy......................8 General policy......................8 Examples of life-support devices........8 Basic Rack Power Distribution Unit Installation i

Preliminary Information American Power Conversions (APC ) AP9560 and AP9561 are 30 A rack-mount Power Distribution Units (PDUs) that provide 120 V, 208 V power to rack-mount equipment. AP9560 pdu0072a 20 A circuit breakers (2) NEMA 5-20 outlets (10) 12-ft NEMA L5-30 power cord AP9561 pdu0071a 10 A circuit breakers (3) IEC-320-C13 outlets (12) 12-ft NEMA L6-30 power cord Basic Rack Power Distribution Unit Installation 1

Safety and Grounding Please read the following information before installing or operating your PDU: This PDU is intended for indoor use only. Do not install this PDU where excessive moisture or heat is present. Never install any wiring, equipment, or PDUs during a lightning storm. Plug this PDU into a three-wire, grounded power outlet only. The power outlet must be connected to appropriate branch circuit/mains protection (fuse or circuit breaker). Connection to any other type of power outlet may result in a shock hazard. Use only the supplied brackets for mounting. Do not use extension cords or adapters with this PDU. Do not work alone under hazardous conditions. Check that the power cord, plug, and socket are in good condition. To reduce the risk of electric shock when grounding cannot be verified, disconnect the PDU from the power outlet before installing or connecting equipment. Reconnect to the power outlet only after making all connections. Equipment must have a protective earth connector which carries the leakage current from the load devices (computer equipment). Do not exceed a total leakage current of 3.5 ma. 2 Basic Rack Power Distribution Unit Installation

Installation PDUs can be mounted in any standard EIA-310 rack or enclosure. Horizontal mounting 1. Attach the horizontal mounting brackets (provided) to the PDU. Caution Use only supplied screws. 2. Install the PDU using the screws and caged nuts included with your rack or enclosure. The PDU will occupy 1 U-space. pdu0080a pdu0085a Basic Rack Power Distribution Unit Installation 3

Installation Vertical mounting 1. Attach the vertical-mounting brackets to the PDU. 2. Install the PDU on a vertical mounting rail in your rack or enclosure. pdu0083a pdu0090a 4 Basic Rack Power Distribution Unit Installation

Specifications Electrical Input voltage range Max current draw AP9560: 100 120 V AP9561: 200 240 V AP9560: 24 A AP9561: 24 A Physical Dimensions (H W D) Shipping dimensions (H W D) Weight Shipping weight 1.75 17.60 2.25 in (4.45 44.70 5.72 cm) 6.00 19.12 6.95 in (15.20 48.60 17.65 cm) 5.5 lb (2.5 kg) 8.0 lb (3.6 kg) Environmental Elevation (above MSL) Operating Storage Temperature Operating Storage Humidity Operating Storage 10,000 ft (3000 m) 50,000 ft (15 000 m) 23 to 113 F ( 5 to 45 C) 13 to 149 F ( 25 to 65 C) 5 95%, non-condensing 5 95%, non-condensing Approvals Safety Certification UL/UL-C Listed to UL1950 Basic Rack Power Distribution Unit Installation 5

Warranty and Service Limited warranty APC warrants the Rack PDU to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. This warranty does not apply to equipment that has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies only to the original purchaser. Warranty limitations Except as provided herein, APC makes no warranties, expressed or implied, including warranties of merchantability and fitness for a particular purpose. Some jurisdictions do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser. Except as provided above, in no event will APC be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of this product, even if advised of the possibility of such damage. Specifically, APC is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you specific legal rights and you may also have other rights, which vary according to jurisdiction. Obtaining service To obtain support for problems with your Rack PDU: 1. Note the serial number and date of purchase. The serial number is located on the bottom of the Rack PDU. 2. Contact Customer Support at a phone number on the back cover of this document.. A technician will try to help you solve the problem by phone. 3. If you must return the product, the technician will give you a return material authorization (RMA) number. If the warranty expired, you will be charged for repair or replacement. 6 Basic Rack Power Distribution Unit Installation

Warranty and Service 4. Pack the unit carefully. The warranty does not cover damage sustained in transit. Enclose a letter with your name, address, RMA number and daytime phone number; a copy of the sales receipt; and a check as payment, if applicable. 5. Mark the RMA number clearly on the outside of the shipping carton. 6. Ship by insured, prepaid carrier to the address provided by the Customer Support technician. Basic Rack Power Distribution Unit Installation 7

Life-Support Policy General policy American Power Conversion (APC) does not recommend the use of any of its products in the following situations: In life-support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life-support device or to affect significantly its safety or effectiveness. In direct patient care. APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that (a) the risks of injury or damage have been minimized, (b) the customer assumes all such risks, and (c) the liability of American Power Conversion is adequately protected under the circumstances. Examples of life-support devices The term life-support device includes but is not limited to neonatal oxygen analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators (for adults and infants), anesthesia ventilators, infusion pumps, and any other devices designated as critical by the U.S. FDA. Hospital-grade wiring devices and leakage current protection may be ordered as options on many APC UPS systems. APC does not claim that units with these modifications are certified or listed as hospital-grade by APC or any other organization. Therefore these units do not meet the requirements for use in direct patient care. 8 Basic Rack Power Distribution Unit Installation

APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests. www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. www.apc.com/support/ Global support searching APC Knowledge Base and using e-support. Contact an APC Customer Support center by telephone or e-mail. Regional centers: Direct InfraStruXure Customer Support Line (1)(877)537-0607 (toll free) APC headquarters U.S., Canada (1)(800)800-4272 (toll free) Latin America (1)(401)789-5735 (USA) Europe, Middle East, Africa (353)(91)702000 (Ireland) Japan (0) 35434-2021 Australia, New Zealand, South Pacific area (61) (2) 9955 9366 (Australia) Local, country-specific centers: go to www.apc.com/ support/contact for contact information. Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support. Entire contents copyright 2005 American Power Conversion Corporation. All rights reserved. Reproduction in whole or in part without permission is prohibited. APC, the APC logo, and InfraStruXure are trademarks of American Power Conversion Corporation. All other trademarks, product names, and corporate names are the property of their respective owners and are used for informational purposes only. 990-1202B 11/2005 *990-1202B*