Construction. SikaTop 111 Plus. Application Instructions. Sika Corporation

Similar documents
Construction. SikaRepair 223. Application Instructions. Sika Corporation

Construction. SikaRepair 223. Application Instructions. Sika Corporation

Construction. SikaRepair SHA. Application Instructions. Sika Corporation

DIVISION 3 - CONCRETE Section Concrete Toppings Section Concrete Resurfacing Section Concrete Rehabilitation

DIVISION 3 CONCRETE Section Concrete Rehabilitation

Construction. Sika Armatec 110. Application Instructions. Sika Corporation

Construction. Sika Armatec 110. Application Instructions. Sika Corporation

PRODUCT DATA SHEET SikaTop -111 Plus

DIVISION 3 - CONCRETE Section Concrete Rehabilitation

Section Shotcrete

DIVISION 3 - CONCRETE Section Concrete Rehabilitation

SITE HANDBOOK. Repair of Concrete Structures. - Patch Repair and Spray Applications

DIVISION 9 - FINISHES Section Protective Coatings

Cementitious Concrete Repair Mortar

R4 Hand Placed / Wet Spray Repair Microconcrete

R4 Hand Placed / Wet Spray Repair Microconcrete

TECHNICAL DATA SHEET SIKA RAPID REPAIR MORTAR 25KG

EN R4 High Strength High Build Concrete Repair Mortar

SECTION CONCRETE REPAIR AND PATCHING

DIVISION 7-THERMAL & MOISTURE PROTECTION Section Cementitious & Reactive Waterproofing

R4 Fast Setting Cementitious Repair Mortar

Polymer bonding aid and mortar additive bonding agent for old and new concrete. Test method Typical result Control. Compressive strength (BS6319,Pt2)

DIVISION 7-THERMAL & MOISTURE PROTECTION Section Cementitious & Reactive Waterproofing

Intercrete 4802 Application Guidelines

PRODUCT DATA SHEET Sika MonoTop Dynamic HP

ARDEX GUIDE SPECIFICATION ARDEX TRM Transportation Repair Mortar Fast-Setting Concrete Repair Mortar

4.16. APPLICATION INSTRUCTIONS Construction Joints & Details

FIVE STAR PRODUCTS, INC. (800)

CONCRETE REPAIR IN ACTION: USING THE MANUAL AS A GUIDE. Christen Longoria, P.E. San Antonio District Project Engineer

B. Samples: Cured samples of materials as required by Architect/Engineer.

Construction. Sikadur 35, Hi-Mod LV. Application Instructions. Sika Corporation

Product Data Sheet Product Description Uses Characteristics / Advantages Tests Approval / Standards Product Data Construction Form

ARDEX GUIDE SPECIFICATION ARDEX FDM Full Depth Repair Mortar Concrete Repair Mortar with Corrosion Inhibitor

Construction. Sikadur 31, Hi-Mod Gel. Application Instructions. Sika Corporation

CONCRETE REPAIR SITE HANDBOOK Hand Placed and Spray Applications

ARDEX A 38TM Rapid Set Screed

Waterproofing and Damp-proofing Cementitious Slurry

ARDEX A 38 MIX Rapid Set, Premixed Screed

PROCEDURES. Cementitious Patch Repair

Construction. R4 Low Resistivity Dry Sprayed Repair Concrete. Product Description. Product Data. Tests. Form. Storage

Spall Repair of Horizontal Concrete Surfaces

Construction. Sika FerroGard Method Statement for Application Corporate Construction. Scope:

Construction. 3-part cement and epoxy combination micro mortar for surface sealing. Product Description 1 1/5. Tests

DIVISION 3 - CONCRETE Section Concrete Toppings Concrete Resurfacing Concrete Rehabilitation

Repair Application Procedures As you may have seen on our website, ICRI s

Easy to apply Nonflammable Low odor Castable Make excellent materials of construction

Bonding Primer and Reinforcement Corrosion Protection

DIVISION 3 CONCRETE Section Grouts

Introducing Raven 760 HPPC

Section Cementitious underlayment

Vertical and Overhead Spall Repair by Hand Application

Construction. Cementitious self levelling, fast hardening, underlayment for use 2-10mm, and 10-30mm with added aggregate. Product Description

Application Instructions for Keystone Kool Deck on Existing Concrete

R3 Cementitious Pore Sealer and Levelling Mortar

2/16/17. Copyright Material. A Repair Technician s Guide to the ACI Chapter 10 Quality Assurance. The Big Picture. Who is a Repair Technician?

San Antonio Water System Standard Specifications for Construction ITEM NO. 307 CONCRETE STRUCTURES

TD Shelf Life: 2 years in original, unopened containers, in dry storage.

FIVE STAR PRODUCTS, INC. (800)

SIDER-BASE CONCENTRATE AAC/ MONOSIDERAL AAC THE ULTIMATE OLD-WORLD AERATED CONCRETE-AAC DECORATIVE STUCCO SYSTEM

GUIDE SPECIFICATION SECTION CRYSTALLINE WATERPROOFING

SECTION SURFACE-APPLIED CRYSTALLINE WATERPROOFING AND CONCRETE REPAIR

SECTION SHOTCRETE Cast-In-Place Concrete Precast Prestressed Concrete Joists and Beams.

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, EDITION OF 1990

SECTION RIGID PAVEMENT

Water Control Structures Selected Design Guidelines Alberta Environment Page 24-1

Installation Instructions Tuscan Field Applied Limestone Finish

ASH GROVE KOLORSTONE BROOMCOAT MIXING KIT. Spec Sheets Contents: Kolorstone Broomcoat Mixing Spec Sheet Kolorflex Admixture Spec Sheet

Section Polymer Modified Cement Waterproofing

Editing notes to assist users are included within bordered boxes. Delete these notes prior to final printing.

ITEM 431 PNEUMATICALLY PLACED CONCRETE. All material shall conform to the pertinent requirements of the following items:

PRODUCT DATA SHEET Sika Galvashield XP

PRODUCT DATA SHEET Sika Level-315 F

CHARACTERISTICS / ADVANTAGES

A-9,250 Parking Structure Resurfacing Cement Look

Coatings CSI Format Section 07160

A. Section includes cast-in-place concrete, including reinforcement, concrete materials, mixture design, placement procedures, and finishes.

SECTION MISCELLANEOUS CAST-IN-PLACE CONCRETE

Construction. One component cementitious mortar fibre reinforced for flexible waterproofing. Product Description. Product Data. Form.

B. All work of the section shall comply with the conditions of the contract, the drawings and any special conditions forming a part of the contract.

PPC Cement TUTORIAL. how to screed a floor

ChemMasters. Installation Guidelines ChemDeck, Water Resistant, Traffic Grade Resurfacing System for Horizontal Concrete

Water resistant bonding agent and mortar additive

1. Payment for concrete sidewalks is on square foot basis. a. Limits for measurement for trench excavation as follows:

PRODUCT DATA SHEET SikaGrout -312 HP

CP1 Precast Concrete Repair: Material and Procedure Selection

ITEM NO. 307 CONCRETE STRUCTURES

SECTION 30 - CONCRETE STRUCTURES TABLE OF CONTENTS

Madewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770)

1. Rapid Set Cement. 2. Methods of preparation. 3. How to stage a job site. 4. Installation Mix, place, finish. 5. Coloring the TRU.

Concrete Repair & Restoration

MATERIALS A Concrete A.1 Concrete Walk... Mix No. 3F52. A.2 Concrete Walk, Exposed Aggregate Finish... Mix No.

MONOBASE AAC/ SIDER-PLAST THE ULTIMATE EXTERIOR HARD COAT STUCCO SYSTEM FOR AUTOCLAVED AERATED CONCRETE

SECTION CAST IN PLACE CONCRETE PART 1 GENERAL 1.01 RELATED DOCUMENTS

TECHNICAL SPECIAL PROVISION FOR CONCRETE REPAIRS. Financial Project ID , &

Construction. Corrosion inhibiting impregnation (improved formulation) Product Description. Product Data Sheet Edition _1

Product Data Sheet Product Description tio Uses tru n Characteristics / Advantages

PRODUCT DATA SHEET Sikafloor -81 EpoCem New HC

TECHNICAL DATA SHEET SIKALASTIC-1K

8245 Remmet Ave Canoga Park, CA (888) Installation Instructions - AVM System 700 Under Tile Waterproofing and Anti-Fracture Membrane

High strength fibre reinforced structural repair mortar

Transcription:

SikaTop 111 Plus Application Instructions

SikaTop 111 Plus Two-component, polymer-modified, portland cement based. Fast-setting, screed mortar. Performance repair mortar for horizontal repairs and form pour/pump vertical and overhead applications. Offers the additional benefit of FerroGard 901- A penetrating corrosion inhibitor.

SikaTop 111 Plus Where to use: On Grade, above, and below grade on concrete and mortar. On horizontal, vertical and overhead surfaces. As a structural repair material for: Parking facilities Industrial plants Water/waste water treatment facilities Walkways, bridges, tunnels, dams, etc. Free-flowing repair mortor for hard-to-reach areas. Filler for voids and cavities.

SikaTop 111 Plus Packaging: A Comp: 1 gal Jug of Dispersion. B Comp: 61.5 lb Multi-wall bag. Coverage:.51 cu. ft / unit. 864 cu. inches per unit.

Surface Preparation Cementitious Substrates: Should be clean and sound. Remove contaminants and bond inhibiting materials from repaired area. Obtain exposed/fractured aggregate surface ~1/16 to 1/2 inch profile (ICRI CSP 6 & above). Substrate must be saturated surface dry (SSD) with no standing water.

Surface Preparation Cementitious Substrates: Surface should be cleaned and roughened to create a profile.

Surface Preparation Saw cut around perimeter or repair area to achieve a minimum 3/8 shoulder. This will eliminate feather edging the product and give a clean transition for the repair.

Surface Preparation Steel: Remove all corrosion and contaminants from exposed steel. Surface should be cleaned thoroughly by blast cleaning or mechanical means. Exposed steel should be cleaned to white steel. If half of the diameter is exposed, chip behind bar, ½ minimum for mortar only.

Steel Preparation Steel should be cleaned to a bright metal finish.

Tools Required ½ Drill Motor. Low speed drill 400-600 rpm. Large mixing paddle Margin trowel

Mixing Pour approximately 7/8 A Component into clean pail. Leave approximately 1 of A Component in jug.

Mixing Add B (powder) Component to pail with A already inside, while mixing continuously.

Mixing 1. Dispersion ¾ -1 gallon of dispersion/bag. 2. Start with adding liquid to the mixing container. 3. Slowly add powder. 4. Once all the powder is added mix for 3 minutes. 5. Do not add any more than the recommended liquid.

Mixing 1. While mixing for 3 minutes stop after 1.5 minutes to scrape down the sides to insure all material is fully mixed. 2. Add additional A Comp. liquid for desired consistency. 3. Most cases you will have liquid left. 4. Thorough mixing and proper proportioning is necessary.

ST 111 PLUS Application Apply the mortar to the patch area while the Armatec 110 EpoCem is still wet. If Armatec is not used as a bonding agent, SSD the surface and scrub coat the repair mortar into the substrate filling all pores and voids.

ST 111 PLUS Application Apply SikaTop repair mortar to patch. Press mortar behind rebar and make sure the material is consolidated and compacted fully. For flow able material, above is not done if pumped or formed and poured

ST 111 PLUS Application Complete filling patch area. Work mortar from the center of the patch to the outside.

Min / Max application thickness Neat Min Max Extended Min Max 1/2 inch 1.0 inch 1.0 inch 6.0 inch

SikaTop 111 PLUS Finish After filling patch section, allow mortar or concrete to set to desired stiffness. Then finish with steel, wood, or sponge float to attain a smooth surface, or broom or burlap-drag for a rough finish.

Sikatop 111 PLUS Finish To assist in the finishing of the SikaTop use SikaFilm. SikaFilm is a finishing aid that also retards moisture evaporation.

SikaTop 111 PLUS Finish You can use a steel trowel to attain a smooth surface.

Sponge Float Finish You can use Sponge float to attain a textured surface.

SikaTop Curing Cure as per ACI recommendations. Curing is required. Moist cure with wet burlap and polyethylene, a fine mist of water or water based curing compound. Moist curing should commence immediately after finishing. Protect newly applied material from direct sun light, wind, rain and frost.

SikaTop 111 Plus Sika Product Data Sheets can be obtained via: www.sikaconstruction.com Refer to data sheets for specific information on each Sika product.