One-Way Wide Module Joist Concrete Floor Design

Similar documents
Agricultural Hall and Annex East Lansing, MI. Structural Design. Gravity Loads. 1- Based on US Standards

Continuous Beam Design with Moment Redistribution (ACI )

Analysis and Design of One-way Slab System (Part-I)

Reinforced Concrete Continuous Beam Analysis and Design (CSA A )

ACI Code Revisions Impact on StructurePoint Software

Lecture-06 Analysis and Design of Slab Systems

Supplemental Plan Check List for Concrete Special Moment Resisting Frame

Continuous Beam Design with Moment Redistribution (CSA A )

Supplemental Plan Check List for Concrete Special Moment Resisting Frame

> 0. 1 f, they are treated as beam-columns.

Reinforced Concrete Spread Footing (Isolated Footing) Analysis and Design. Design Footing

Design of Reinforced Concrete Slabs

Precast Concrete Bearing Wall Panel Design (Alternative Analysis Method) (Using ACI )

Fundamentals of Post Tensioned Concrete Design for Buildings

Section A A: Slab & Beam Elevation

VARIOUS TYPES OF SLABS

Reinforced Concrete Tilt-Up Wall Panel with Opening Analysis and Design (ACI 551)

Reinforced Concrete Tilt-Up Wall Panel Analysis and Design (ACI 551)

Structural Technical Report 1 Structural Concepts / Structural Existing Conditions Report

William W. Wilkins Professional Building

Two-way slabs. Flat plate with or without drop panels / capitals

Multi-Story Solid Tilt-Up Wall Panel Analysis and Design (ACI 551)

Footings GENERAL CONSIDERATIONS 15.2 LOADS AND REACTIONS 15.4 MOMENT IN FOOTINGS

OVERALL STRUCTURAL SYSTEM

DIRECT DESIGN METHOD DDM

Earth and Engineering Sciences Building University Park, Pennsylvania

111 MORGAN ST. Ryan Friis

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures

USE OF 500 GRADE STEEL IN THE DESIGN OF REINFORCED CONCRETE SLAB. Prof. M. Shafiul Bari, Ph.D Department of Civil Engg., BUET

Software Verification

eight plates and grids APPLIED ACHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2018 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

VOL I: Bridge Design & Load Rating

Design Example 2 Reinforced Concrete Wall with Coupling Beams

THE FORENSIC MEDICAL CENTER

eight plates and grids Plates, Slabs & Grids Plates, Slabs & Grids Term Project plates horizontal plane, rigid slabs thin, flat, rigid

ADAPT PT7 TUTORIAL FOR ONE-WAY SLAB 1

Alexis Pacella Structural Option Dr. Schneider Lexington II, Washington D.C. Technical Report #2 October 31,

Seismic Behaviour of RC Shear Walls

Structural Engineering, Mechanics, and Materials. Preliminary Exam - Structural Design

ADAPT PT7 TUTORIAL FOR BEAM FRAME 1

ADAPT-PTRC 2016 Getting Started Tutorial ADAPT-PT mode

Strength Design of Reinforced Concrete Structures

Alexis Pacella Structural Option Dr. Schneider Lexington II, Washington D.C. Technical Report #3 November 21,

Table of Contents 2. Structural Systems.4 Foundations.4 Floor System...4 Columns..5 Lateral System...5

MASONRY WALL DATA: Wall Height = ft. Nominal Wall Thickness = 8.00 in. Depth to c.g. Steel, Wall = 3.81 in.

Chapter 2 Notation and Terminology

(b) Calculate the required nominal axial compression strength, Pn of the column.

THE FORENSIC MEDICAL CENTER

Design and analysis of T and inverted L beams- Theory and Examples

ADAPT-PT 2010 Tutorial Idealization of Design Strip in ADAPT-PT

48.5% Throughput. 6 Connector 51.5% Plastic. 45.7% Throughput. 4 Connector 54.3% Plastic. 51.0% Throughput. 2 Connector 49.

CHAPTER 2. Design Formulae for Bending

Schöck Isokorb Type CM

Appendix M 2010 AASHTO Bridge Committee Agenda Item

Caitlin Ferrell Structural Option Dr. Boothby, AE Faculty Consultant. Erie Convention Center and Sheraton Hotel

Steel Design Guide Series. Steel and Composite Beams with. Web Openings

Structural Option April 7 th, 2010

Comparison of One-way and Two-way slab behavior. One-way slabs carry load in one direction. Two-way slabs carry load in two directions.

Third Avenue New York, NY. Structural Concepts/ Structural Existing Conditions Report September 30, Michelle L.

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: MMFX TECHNOLOGIES A COMMERCIAL METALS COMPANY

Check the strength of each type of member in the one story steel frame building below.

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

Composite Steel/Concrete

2016 DESIGN AND DRAWING OF REINFORCED CONCRETE STRUCTURES

Danielle Shetler - Structural option Courtyard by Marriott Lancaster, PA

Modjeski and Masters, Inc. Consulting Engineers 04/18/06 St. Croix River Bridge 3D Analysis Report Introduction

ADAPT Floor Pro 2009/2010 Tutorial Export Design Strip to ADAPT PT or ADAPT RC

Lintel Tables Design Notes and Limitations

Schöck Isokorb Type CV

Investigation for the Removal of Steel Tie Rods in a Historic Segmental Arch Floor

Structural System Design

Reinforced Concrete Design. Lecture no. 1

Special Reinforced Concrete Structural Walls

Iterative Optimization of a Typical Frame in a Multi-Story Concrete Building. Description of Program Created by Joseph Harrington

REINFORCED CONCRETE WALL BOUNDARY ELEMENT LONGITUDINAL REINFORCING TERMINATION

SEAU 5 th Annual Education Conference 1. ASCE Concrete Provisions. Concrete Provisions. Concrete Strengths. Robert Pekelnicky, PE, SE

Arlington, Virginia December 3, 2007 TECHNICAL REPORT III LATERAL SYSTEM ANALYSIS AND CONFIRMATION DESIGN

TECHNICAL REPORT 1. Structural Concepts / Structural Existing Conditions. Penn State Hershey Medical Center Children s Hospital. Hershey, Pennsylvania

C H A N T I L L Y, V A

The problems in this guide are from past exams, 2011 to 2016.

How to Design a Singly Reinforced Concrete Beam

DESIGN CALCULATIONS INSTA-FOOTING LOAD BEARING CAPACITIES ON CONCRETE SLAB. January 14, 2017 Rev -

10.5 ECCENTRICALLY LOADED COLUMNS: AXIAL LOAD AND BENDING.

Reinforced Concrete Design

COLUMNS 1- Definition: The Egyptian code defines columns as : 2- Types of concrete columns

International Journal of Advance Engineering and Research Development REVISION OF IS: A REVIEW (PART 2)

STRUCTURAL APPLICATIONS OF A REINFORCED CONCRETE BEAM-COLUMN-SLAB CONNECTION MODEL FOR EARTHQUAKE LOADING

Punching Shear Resistance of Flat Slabs By Shear Heads

twenty two concrete construction: flat spanning systems, columns & frames ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN

Bjorhovde, R. Stub Girder Floor Systems Structural Engineering Handbook Ed. Chen Wai-Fah Boca Raton: CRC Press LLC, 1999

HIGH RISE CONDO SOHO, NEW YORK, NY

Structural Technical Report I October 5, 2006 Structural Concepts / Structural Existing Conditions Report

CANADIAN CODE IMPLEMENTATION IN 1 ADAPT SOFTWARE

Appendix A Tables and Diagrams

Rutgers University Law School Building Addition and Renovation Camden, NJ

Technical Report 2: Pro-Con Structural Study of Alternate Floor Systems

Design of Semi gravity Retaining Walls

Table of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8

How Loads Are Distributed

Crossroads at Westfields Building II

Transcription:

One-Way Wide Module Joist Concrete Floor Design A 1 3 4 30'-0" 30'-0" 30'-0" 3' B 3' C 3' D 3' E 4" 4" (typ.) 3' F 0" 0" (typ.) Figure 1 One-Way Wide Module Joist Concrete Floor Framing System 1

Overview A typical floor plan of a 5-story office building located in Los Angeles, CA is shown in Figure 1. The wide-module joist floor system with special reinforced concrete shear walls is selected as the structural system. As the building is assigned to the Seismic Design Category D, building frame is to be designed to resist the gravity loads only and the lateral load effects are resisted by the shear walls. 6 ft Module with 66 in. pan width and 6 in. rib width shall be utilized. Code Building Code Requirements for Structural Concrete (ACI 318-11) and Commentary (ACI 318R-11) Minimum Design Loads for Buildings and Other Structures (ASCE/SEI 7-10) International Code Council, 009 International Building Code, Washington, D.C., 009 Design Data Floor Heights: Typical Floor-to-Floor Height 1 ft First Story Height 16 ft Material Properties: Concrete: Unit weight of normal weight concrete, w c 150 pcf, Specified compressive strength, f ' c 5000 psi Reinforcing Steel: Specified yield strength of reinforcement, f y 60000 psi, Specified yield strength of transverse reinforcement, f yt 60000 psi Loads: Dead Loads Self-weight is to be determined. Superimposed dead load, 0 psf (Typical floor levels only) Live Loads Minimum uniformly distributed live loads, L o, and minimum concentrated live loads are given in ASCE/SEI 7-10, Table 4-1. Typical Floor Level, Live load, L o 80 psf (Average value of 80 psf is considered by inspection of Table 4-1 for Office Buildings) Minimum concentrated live load of 000 lb uniformly distributed over an area of.5 ft needs to be located so as to produce the maximum load effects in the structural members per ASCE/SEI 7-10, 4.3. For simplicity, this requirement is not considered in this example. Roof Live Load, L o 0 psf (Ordinary flat roofs) Required fire resistance rating = hours

Solution 1. PRELIMINARY SIZING 1.1. Determine the preliminary slab and joist sizes for 6-0 wide-module joist system 1.1.a. One-way Slab In lieu of detailed calculation for the deflections, ACI 318 gives minimum thickness for one-way slabs in Table 9.5 (a). l 7 End Spans: h 3. 9 in 18.5 18.5 l 7 Interior Spans: h 3. 4 in 1 1 The slab thickness for wide-module joists is generally governed by the fire rating. From IBC 009, Table 70.1(3), for -hour fire rating, the minimum slab thickness is 4.6 in. Therefore, select slab thickness as 5 in for all spans. 1.1.b. One-way Joist Since the wide-module joist systems do not meet the limitations of ACI 318, 8.13.1 through 8.13.3, the structural members of this type of joist construction shall be designed as slabs and beams as stated in ACI 318, 8.13.4. In lieu of detailed calculation for the deflections, ACI Code gives minimum thickness for nonprestressed beams in Table 9.5 (a). l 384 End Span: h 0. 8 in (governs) 18.5 18.5 l 384 Interior Span: h 18. 3 in 1 1 Therefore, select pan depth of 16 in. which makes the total joist depth as 1 in. 1.. Determine the preliminary column sizes for 6-0 wide-module joist system 1..a. Interior Columns Select a preliminary size based on the axial load demand. Therefore, the load take-down for an interior column is done as follows: The governing load combination: U 1.D 1.6L 0.5L where D = Dead Load; L= Live Load; L r = Roof Live Load r Typical Floor Level Loads No. of Floors 4 Dead Loads, D Self-weight of wide-module joist system (16 + 6 + 66) 497 plf (From CRSI Design Handbook 008, Table 8-3(b). This is equal to 497/ 6 8. 83psf. Superimposed dead load 0 psf Live Load, L: Calculate the live load reduction per ASCE/SEI 7-10, section 4.8. 15 L Lo (0.5 ) ASCE/SEI 7-10, Eq (4-1) K A LL T 3

where L reduced design live load per ft of area supported by the member Lo unreduced design live load per ft of area supported by the member K live load element factor (ASCE 7-10, Table 4-) LL A tributary area in ft T Tributary Area (30' 0" 3' 0") 960 ft L o 80 psf A T 15 L 80 (0.5 ) 39.4 psf 4 960 which satisfies 0.40 Lo requirement for members supporting two or more floors per ASCE/SEI 7-10, section 4.8.1 Roof Level Loads Dead Loads, D Self-weight of wide-module joist system (16 + 6 + 66) 497 plf (From CRSI Design Handbook 008, Table 8-3(b). This is equal to 497/ 6 8. 83psf. No superimposed dead load at the roof Roof Live Load, L r : Calculate the roof live load reduction per ASCE/SEI 7-10, section 4.9. L r L R R where 1 L r 0 ASCE/SEI 7-10, Eq (4-) o L o 0 psf 1 R 1 0.6 since A T 960 ft 600 ft R 1 for flat roof L r 0 0.61.0 1 psf Total Factored Load on 1 st story interior column (@ 1 st interior support) Total Floor Load 4 1. 8.83 01.6 39.6 960 717143 Total Roof Load 1. 8.83 1.6 1 960 11385 lb 113. 9 lb 717. 1kips kips Assume 4 in square column with 4 No. 11 vertical bars with design axial strength, P n,max 0.80 0.85f ' P n, max of c A g A st f ya st 0.855000 4 4 41.56 60000 41.56 1453858 0.80 0.65 lb P n, max P n, max 1454 kips 4 4 1. 144 Column Self-weight 0.15 4 1 16 46. 1 kips Total Reaction @ 1 st interior support 1.15 717.1113.9 46.1 100 kips 1454 kips. Therefore, the interior column size of 4x4 is adequate. By utilizing the same procedure as outlined above, it is concluded that for the edge and corner columns 0x0 size shall be adequate. 4

. DESIGN OF STRUCTURAL MEMBERS Thedesign of the following structural members shall be performed:.1. One-way slab.. One-way Joist.3. Interior Beam.4. Spandrel Beam.5. Interior Column The computer program solutions shall also be represented for each structural member listed above..1. One-way Slab Design The typical floor slab design shall be performed. The slab is spanning between joists and designed to carry gravity loads. The unit strip of 1 ft shall be considered in the design. Note that ACI 318 does not allow live load reduction for one-way slabs. Figure.1 Partial plan view illustrating slab design strip 5

The design involves the following steps:.1.1. Determination of span loads.1.. Determination of design moments and shears.1.3. Flexural Design.1.4. Shear Design.1.5. Deflections.1.6. Computer Program Solution.1.7. Summary and comparison of design results.1.8. Conclusions and observations.1.1. Determination of span loads ACI 318, 9..1 gives the following load combinations for structural members loaded with dead and live loads: U 1.4D ACI 318, Eq. 9-1 U 1.D 1.6L ACI 318, Eq. 9-5 Factored total load per Eq. 9-1: w u 1.4 0.15 0.0 0. 116 1 klf per ft 5 Factored total load per Eq. 9-: w u 1. 0.15 0.0 1.6 0.08 0. 7 1 klf per ft The span loads are governed by load combination per Eq. 9-..1.. Determination of design moments and shears Using the approximate coefficients of ACI 318, 8.3.3, the factored moments, and shears are determined and summarized in the Tables.1.1, and.1.. respectively below. End Spans Interior Spans Table.1..1 One-Way Slab Design Moments Location Design Moment Value Exterior Support Negative Mid-span Positive Interior Support Negative Mid-span Positive Support Negative w ul 4 w ul 14 w ul 10 w ul 16 w ul 11 n n n n n 0.7 5.5 4 0.7 5.5 14 0.7 5.5 10 0.7 5.5 16 0.7 5.5 11 0.9 ft-kips/ft 0.49 ft-kips/ft 0.69 ft-kips/ft 0.43 ft-kips/ft 0.6 ft-kips/ft 6

Table.1.. One-Way Slab Design Shears Location Design Shear Value End Span at Face of w uln 0.7 5.5 1.15 1.15 0.7 kips/ft First Interior Support w At Face of all other Supports u l n 0.7 5.5 0. 6 kips/ft.1.3. Flexural Design For the one-way slab of a wide-module joist system, single layer longitudinal reinforcement is to be provided. The first interior support negative moment governs the design as tabulated in Table.1..1. Therefore, it is favorable to place the single layer reinforcement closer to the top fiber of the concrete. The required reinforcement shall be calculated for the first interior support negative moment first. The required reinforcement for the end span positive moment shall also be calculated as the low effective depth due to the reinforcement location may govern the required reinforcement amount. Finally, the required reinforcement for design shall be checked against the shrinkage and temperature reinforcement requirement per ACI 318, 7.1..1. Calculate the required reinforcement to resist the first interior support negative moment: M u 0.69 ft-kips/ft Assume tension-controlled section ( 0. 9 ). Note that this assumption shall be verified within the calculations below. Unit strip width, b 1 in The one-way slab reinforcement is to be placed on top of the one-way joist top reinforcement. Assuming No. 3 bars for both the slab and wide-module joist stirrups and following the 1 1/ concrete cover to reinforcement requirement of beam stirrups per ACI 318, 7.7, the distance from extreme compression fiber to the centroid of longitudinal tension reinforcement, d, is calculated below: 3 d 5 1.5 0.5 3.31 in 8 Since we are designing a slab (wide compression zone), select a moment arm, jd approximately equal to 0.95d. Assume that jd 0.95d 0.95 3.31 3. 15 in. Required reinforcement @ initial trial, A A s 0.049 in /ft s M fy u M u 0.69 1,000 d a / fyjd 0.9 60,000 3. 15 Use one-iteration to refine this value by inserting it in the equation that finds the depth of the equivalent stress block. As fy 0.049 60,000 Depth of equivalent stress block, a 0. 058 in. 0.85f c b 0.85 5,0001 a 0.058 Neutral axis depth, c 0. 068 in. 0.85 1 7

0.003 0.003 Strain at tensile reinforcement, t ( ) d t 0.003 ( ) 3.31 0.003 0.143 0. 005 c 0.068 Therefore, the section is tension-controlled. Use the value of a, ( a 0.058in), to get an improved value for A s. A s Mu 0.691,000 0.047 in /ft a 0.058 fy(d ) 0.9 60,000(3.31 ) Calculate the required reinforcement to resist the positive moment M u 0.49 ft-kips/ft Assume tension-controlled section ( 0. 9 ). Note that this assumption shall be verified within the calculations below. Unit strip width, b 1 in The distance from extreme compression fiber to the centroid of longitudinal tension reinforcement d 5 3.311.69 in. Since we are designing a slab (wide compression zone), select a moment arm, jd approximately equal to 0.95d. Assume that jd 0.95d 0.951.69 1. 60 in. Required reinforcement @ initial trial, A A s 0.068 in /ft s M fy u M u 0.49 1,000 d a / fyjd 0.9 60,000 1. 60 Use one-iteration to refine this value by inserting it in the equation that finds the depth of the equivalent stress block. As fy 0.068 60,000 Depth of equivalent stress block, a 0. 08in. 0.85f b 0.855,0001 a 0.08 Neutral axis depth, c 0. 094 in. 0.85 1 c 0.003 0.003 Strain at tensile reinforcement, t ( ) d t 0.003 ( ) 1.69 0.003 0.051 0. 005 c 0.094 Therefore, the section is tension-controlled. Use the value of a, ( a 0.08in), to get an improved value for A s. Mu 0.491,000 As 0.066 in /ft a 0.08 fy(d ) 0.9 60,000(1.69 ) The required reinforcement from analysis is 0.66 in /ft. In this example, positive moment value controls the design due to the placement of slab reinforcement near top concrete surface even though it is not the governing design moment for the slab. Check the shrinkage and temperature reinforcement requirement per ACI 318, 7.1..1. A s 0.0018bh 0.00181 5 0.108 in / ft 8

Check reinforcement spacing for crack control. Per ACI 318, 10.6.4, the maximum spacing of the flexural reinforcement closest to the tension face of the slab shall be: 40000 40000 s 15.5cc f, but not greater than 1 s f s where s maximum reinforcement spacing for crack control fs cc calculated stress in reinforcement closest to the tension face at service load the least distance from surface of reinforcement to the tension face. ACI 318, 10.6.4 permits to take f s as / 3f y Therefore, for Grade 60 steel, ACI 318 permits f s to be taken as / 3f y 40000 psi. c c 1.5 in for reinforcement resisting negative moment at supports (i.e. tension at the top) c c 3.15 in for reinforcement resisting positive moment at mid-span (i.e. tension at the bottom) Thus, At supports 40000 s 15.5c f s c 40000 15.51.5 11.5 in (governs @ support) 40000 40000 40000 But not greater than s 1 1 1 f in s 40000 At mid-span 40000 s 15.5c f s c 40000 15.53.15 7.19 in (governs @ mid-span) 40000 40000 40000 But not greater than s 1 1 1 f in s 40000 Therefore, for this one-way slab, the shrinkage and temperature reinforcement requirement per ACI 318, 7.1 governs the required reinforcement area ( A s 0. 108 in / ft) and crack control requirement per ACI 318, 10.6.4 governs the reinforcement spacing ( s 7. 19 in). The most feasible reinforcement solution that meets both requirements mentioned above is to provide welded wire fabric reinforcement, 6 x 6-W5.5 x W5.5. Note that the welded wire reinforcement selected provides minimum shrinkage and temperature reinforcement in the slab direction parallel to the joists as well. Alternately, rebar can be utilized in lieu of welded wire fabric. As illustrated above, reinforcing spacing of 7 in shall meet the spacing requirement for crack control in the main direction. It should be noted that two conditions specific to this design contributes to having such a stringent spacing requirement. These are listed below: 9

- The 5 in. slab has a single layer reinforcement that is placed near the top surface (i.e. clear cover from the top surface to the reinforcement is 1.5 in. This result in a high c c value for the calculation of reinforcement spacing for crack control due to positive moment. - The stress in reinforcement closest to the tension face at service load, f s, is taken as / 3f y as permitted by ACI 318 without calculation. It is very likely that under the loading considered, the stress in the steel be lower than / 3f y. The f s value is expected to be in the range of 1/ 3f y to 1 / f y. Even it is assumed to be 1 / f y, s value will be 1 in. The designer may choose to calculate the actual f s value which may justify utilizing No. 3 @ 1 in. in the main direction. In the slab direction parallel to the joists No. 3 @ 1 in. shall suffice..1.4. Shear Design From Table.1.. above, the shear value in end span at face of first interior support governs. w uln Vu 1.15 (1.15 0.7 5.5) / 0.7 kips / ft The design shear at a distance, d, away from the face of support, 1.69 V u 0.7 0.7 0.69 kips / ft 1 Shear strength provided by concrete 1.0 500011.69 151 V ( f ' b d 0.75 lb / ft. 15 kips / ft c c w V u 0.69 kips / ft V c 4. 1kips / ft. Therefore, the slab shear capacity is adequate..1.5. Deflections ACI 318 provides the minimum thickness of nonprestressed one-way slabs in Table 9.5(a) unless deflections are calculated. Since the preliminary slab thickness met this requirement, the deflection calculations are waived here. Typically, in hand solutions, the designer opts to follow ACI 318, 9.5. in lieu of deflection calculations which can be long and tedious. It should be noted that unless governed by fire rating requirements as in this example, in most other cases, lesser thicknesses and consequent cost savings can be achieved through deflection computations. 10

.1.6. Computer Program Solution spslab Program is utilized to design the one-way slab system. The one-way slab is modeled as 1-ft unit strip. The exterior spandrel joists along grids 1 and 4 provide some rotational stiffness at the support. In spslab solution, the rotational stiffness is conservatively ignored by modeling the exterior supports as pin supports. This results in exterior support moment value being zero and conservatively higher positive moment and interior support moment for the end spans. Also, for one-way slab run, the joists are omitted in the model and centerline moments are considered for the design moments. Note that spslab allows a user-defined reinforcement sizes as well. In this example, user-defined bar size # is defined in lieu of welded wire fabric,w5.5, with the cross-sectional area of 0.055 in (see Fig..1.6). Figure.1.6 spslab Reinforcement Database User-defined Bar Set The program calculates the internal forces (shear force and bending moment), moment and shear capacities, immediate and long-term deflections. The graphical and text results are provided in the Appendix A for input and output of the spslab program. 11

.1.6.1 Isometric View of 15 span - 1-ft wide unit strip of One-way Slab from spslab 1

.1.6. spslab Model Calculated Internal Forces (Shear Force & Bending Moment) 13

.1.6.3 spslab Model Calculated Immediate Deflections 14

.1.7. Summary and Comparison of Results 15

Span Location End Span Table.1.7.1 Comparison of Hand Solution with spslab Solution Reinforcement Required for Flexure (in /ft) Hand Solution spslab Solution Minimum Reinforcement (in /ft) (Shrinkage & Temperature Reinforcement) Hand Solution spslab Solution Interior Negative 0.047 0.058 0.108 0.108 Positive 0.066 0.083 0.108 0.108.1.8. Conclusions and Observations In this design example, the modeling of the exterior support condition as pin compared to the hand solution which utilizes the approximate moments per ACI 318, 8.3.3 does not influence the design of flexural reinforcement due to the fact that the shrinkage and temperature reinforcement requirement governs the required reinforcement criteria. In general, the pin support assumption may be employed by the designer as it yields the conservative values for reinforcement. However, spslab program also enables the user to enter the rotational support springs as boundary conditions for exterior support for proper assessment of rotational stiffness effects. Typically, in wide-module joist construction, one-way slab is reinforced with single layer reinforcement placed near the top in the main direction. As seen in this example, this may create crack control criteria to govern the reinforcement spacing and consequently, it may warrant the use of welded wire fabric reinforcement instead of No. 3 rebar. 16

.. One-way Joist Design The typical floor one-way joist design shall be performed. The wide-module joists are considered as beams per ACI 318, 8.13.4. Therefore, the design of the joist shall conform to the requirements of T-beams per ACI 318, 8.1. Figure. Partial plan view illustrating one-way joist to be design The design involves the following steps:..1. Determination of span loads... Determination of design moments and shears..3. Flexural Design..4. Shear Design..5. Deflections..6. Computer Program Solution..7. Summary and comparison of design results..8. Conclusions and observations..1. Determination of span loads ACI 318, 9..1 gives the following load combinations for structural members loaded with dead and live loads: U 1.4D ACI 318, Eq. 9-1 U 1.D 1.6L ACI 318, Eq. 9- Check Floor Live Load Reduction per ASCE 7-10, sections 4.8. 15 L Lo (0.5 ) ASCE 7-10, Eq (4-1) K LLAT where Live Load Element Factor, K LL for interior beams [ASCE/SEI 7-10, Table 4-] 17

Tributary Area (6' 0" 3' 0") 19 ft A T Since K A 19 384 ft 400 ft, live load reduction is not applicable. LL T Factored total load per Eq. 9-1: 5 6 8.66/ 16 w u 1.4 0.15 0.0 6 0.15 0.86 1 1 1 klf Factored total load per Eq. 9-: 5 6 8.66/ 16 w u 1. 0.15 0.0 6 0.15 1.6 0.08 6 1 1 1 w u 1.51klf The span loads are governed by load combination per Eq. 9-.... Determination of design moments and shears Using the approximate coefficients of ACI 318, 8.3.3, the factored moments, and shears are determined and summarized in the Tables...1, and... respectively below. End Spans Interior Spans Table...1 One-Way Joist Design Moments Location Design Moment Value Exterior Support Negative Mid-span Positive Interior Support Negative Mid-span Positive Support Negative w ul 4 w ul 14 w ul 10 n n n w ul 16 w ul 11 1.51 30.17 4 1.51 30.17 14 1.51 30.08 10 n n 1.51 30 16 1.51 30 11 57.3 ft-kips 98. ft-kips 136.6 ft-kips 84.9 ft-kips 13.5 ft-kips Location End Span at Face of First Interior Support Table... One-Way Joist Design Shears Design Shear Value w ul n 1.5130.17 1.15 1.15 6. kips w At Face of all other Supports u l n 1.5130.17. 8 kips *when support beam is wider than the column, the clear span, l n, of the joists is measured from the face of the column. For calculating negative moments, l n, is taken as the average of the adjacent clear spans per ACI 318, 8.3.3. 18

..3. Flexural Design For the one-way joist of a wide-module joist system, the end span moment values govern the design as tabulated in Table...1. Calculate the required reinforcement to resist the first interior support negative moment: M u 136.6 ft-kips Assume tension-controlled section ( 0. 9 ). Note that this assumption shall be verified within the calculations below. By assuming the maximum bar size for joist top reinforcement as No. 6, the distance from extreme compression fiber to the centroid of longitudinal tension reinforcement, d, is calculated below: 3 6 d 1 1.5 0.5 18.75 8 8 in Since we are designing for the negative moment in a T-Beam (narrow compression zone), select a moment arm, jd approximately equal to 0.9d. Assume that jd 0.9d 0.9 18.75 16. 88 in. Required reinforcement @ initial trial, A A s 1.80 in s f y M u M 136.6 1,000 d a / f jd 0.9 60,00016. 88 y u Use one-iteration to refine this value by inserting it in the equation that finds the depth of the equivalent stress block. As fy 1.80 60,000 Depth of equivalent stress block, a 3. 47 in. 0.85f b 0.85 5,000 7.33 a 3.47 Neutral axis depth, c 4. 08 in. 0.85 1 c 0.003 0.003 Strain at tensile reinforcement, t ( )dt 0.003 ( )18.75 0.003 0.0108 0. 005 c 4.08 Therefore, the section is tension-controlled. Use the value of a, ( a 3.47in), to get an improved value for A s. A s Mu 136.61,000 1.78 in a 3.47 f y (d ) 0.9 60,000 (18.75 ) According to ACI 318.10.5.1, the minimum reinforcement shall not be less than A s 3 fc 3 5,000 bwd 7.3318.75 0.49 in f 60,000 y 00b wd 00 7.33 18.75 and not less than 0. 46 in f y 60,000 ACI Code Section 10.6.6 states that part of the negative-moment steel shall be distributed over a l 384 width equal to the smaller of the effective flange width (7in) and 38. 4 in. 10 10 Provide 6-No. 5 bars within 38.4 in width. A s, prov 6 0.31 1. 86 in 1. 78 in O.K. 19

Calculate the required reinforcement for the positive moment, M u 98. ft-kips In the positive moment regions, the beam acts as a T-shaped beam. The effective width of the overhanging flange on each side of the beam web is the smallest of the following per ACI 318, 8.1. 0.5l n 0.5 (30.17 1) 90.5 in b w b w (8 5) 8.66 40 88.66 in 5.51 6 66 7 in Therefore, the effective flange width is 7 in Assume tension-controlled section ( 0. 9 ). Note that this assumption shall be verified within the calculations below. By assuming No. 3 bars for wide-module joist stirrups & the maximum bar size for joist bottom reinforcement as No. 7 and following the 1 1/ concrete cover to reinforcement requirement of beam stirrups per ACI 318, 7.7, the distance from extreme compression fiber to the centroid of longitudinal tension reinforcement, d, is calculated below: 3 7 d 1 1.5 0.5 18.69 8 8 in Since we are designing for the positive moment in a T-Beam (wide compression zone), select a moment arm, jd approximately equal to 0.95d.Assume that jd 0.95d 0.9518.69 17. 76 in. Mu 98. 1,000 Required reinforcement @ initial trial, As 1. 3 in f y jd 0.9 60,000 0.9518.69 Assume that the depth of the equivalent stress block, a, is less than the slab thickness, then, use oneiteration to refine this value by inserting it in the equation that finds the depth of the equivalent stress block. Asf y Depth of equivalent stress block, a 0.85f c b where b is the effective flange width of 7 in. 1.3 60 a 0.41in which is less than the slab thickness. Therefore, it checks. 0.855 7 a 0.41 Neutral axis depth, c 0. 84 in. 0.85 1 0.003 0.003 Strain at tensile reinforcement, c ( )d t 0.003 ( )18.69 0.003 0.194 0. 005 c 0.84 Therefore, the section is tension-controlled. Use the value of a, ( a 0.41in), to get an improved value for A s. 0

A s M u 98. 1,000 1.18 in a 0.41 f y (d ) 0.9 60,000 (18.69 ) Use -No. 7 bundled bars with A s 1. 0 in > 1. 18 in O.K. 1

Section /. Cross-sectional View at Joist mid-span Section 3/. Cross-sectional View at Joist near support face..4. Shear Design From Table... above, the shear value in end span at face of first interior support governs. 1.15w uln 1.15 1.51 30.17 Vu 6. kips The design shear at a distance, d, away from the face of support, 18.69 V u 6. 1.51 3.9 kips / ft 1 Shear strength provided by concrete Vc ( f ' c bwd) 0.75 1.0 5000 7.3318.69 14531lb 14. 5 kips Vc Since Vu, shear reinforcement is required. Try No. 3, Grade 60 double-leg stirrups with a 90 hook. The nominal shear strength required to be provided by steel is V V s n V c Vu V c 3.9 ( ) 19.3 1.6 kips 0.75

Check whether V is less than8 f bwd s c If V is greater than s 8 c w f b d, then the cross-section has to be increased as ACI 318-11.4.7.9 limits the shear capacity to be provided by stirrups to 8 w fc b d. f b d 8 5,000 7.3318.69 77498 lb 77. 5 kips 8 c w Since Vs does not exceed 8 f bwd. The cross-section is adequate. Assume No. 3 stirrups with two legs ( A v 0. in ) Calculate the required stirrup spacing as c A vf ytd 0.75 0. 6018.69 s(req'd) 19.7 in. Vu Vc 3.9 14.5 Check whether the required spacing based on the shear demand meets the spacing limits for shear reinforcement per ACI 318, 11.4.5.1. Check whether V is less than f b d s c 4 c w If V s is greater than 4 f bwd, then the maximum spacing of shear reinforcement given in 11.4.5.1 and 11.4.5. shall be reduced by one-half per ACI 318.11.4.5.3 f b d 4 5,000 7.3318.69 38749 lb 38. 75 kips 4 c w Since V does not exceed s f b d, the maximum stirrups spacing limits per ACI 318.11.4.5.1 4 c w govern. Therefore, maximum stirrup spacing shall be the smallest of d and 4 in. s(max) d 18.69 Min ; 4 in Min ; 4 in s(max) 9.35 in. This value governs over the required stirrup spacing of 19.7 in which was based on the demand. For a wide-module joist, the minimum shear reinforcement requirements shall need to be checked as wide-module joists does not fit into the category of concrete joist construction defined by ACI 318, 8.13. Check the maximum stirrup spacing based on minimum shear reinforcement Avf yt 0.60000 s(max) 34 in (does not govern) 0.75 f ' b 0.75 5000 7.33 c w A vf yt 0. 60000 s(max) 36 in (does not govern) 50bw 50 7.33 Therefore, s(max) value is governed by the spacing limit per ACI 318, 11.4.5.1, and is equal to 9.35 in. Use No. 3 @ 9 in. stirrups V n A v f s yt d V c 0. 60 18.69 19.3 7.4 19.3 46.7 kips 9 0.75 46.7 35.0 kips > V u 3. 9 kips O.K. V n 3

Compute where Vu Vc ( ) ( ) ln x Vu Vu V is equal to c, and the stirrups can be stopped 3.9 19.3 ( ) ( ) 0.75 30.17 1 x 16 in. 3.9 ( ) 0.75 At interior end of the exterior span, use 16-No. 3 @ 9 in o.c., Place 1 st stirrup in. from the face of supporting girder...5. Deflections ACI 318 provides the minimum thickness of nonprestressed beams in Table 9.5(a) unless deflections are calculated. Since the preliminary beam depth met this requirement, the deflection calculations are waived here. Typically, in hand solutions, the designer opts to follow ACI 318, 9.5. in lieu of deflection calculations which can be long and tedious. It should be noted that, in most other cases, lesser thicknesses and consequent cost savings can be achieved through deflection computations...6. Computer Program Solution spslab Program is utilized to design the one-way wide-module joist. The single wide-module joist is modeled as a T-beam. The program calculates the internal forces (shear force and bending moment), moment and shear capacities, immediate and long-term deflection results, and required flexural reinforcement. The graphical and text results are provided below for both input and output of the spslab model. 4

..6.1 Isometric View of One-way Joist from spslab 5

..6. spslab Model Calculated Internal Forces (Shear Force & Bending Moment) 6

..6.3 spslab Model Calculated Immediate Deflections 7

..7. Summary and Comparison of Design Results 8

Span Location End Span Table..7.1 Comparison of Hand Solution with spslab Solution Required Reinforcement Area for Flexure (in ) Hand Solution spslab Solution Reinforcement Provided Hand Solution spslab Solution Interior Negative 1.78 1.610 6 No. 5 6 No. 5 Positive 1.18 1.008 No. 7 No. 7..8. Conclusions and Observations In this design example, the one-way joist system is modeled as a continuous T-beam representing single one-way joist. There is a good agreement between the hand solution and computer solution. 9

.3. Design of a Continuous Beam along Grid B (Interior Frame) Design of the interior beam along grid B shall be performed. In the wide-module joist construction, the supporting beam depths shall be same as the overall joist depth. Therefore, the beam depth is set at 1 in. This depth satisfies the minimum thickness requirement of ACI 318, Table 9.5 (a) so that the deflection computations can be waived. Figure.3 Partial plan view showing interior beam along grid B The design involves the following steps:.3.1. Determination of span loads.3.. Determination of design moments and shears.3.3. Flexural Design.3.4. Shear Design.3.5. Deflections.3.6. Computer Program Solution.3.7. Summary and comparison of design results.3.8. Conclusions and observations.3.1. Determination of span loads ACI 318, 9..1 gives the following load combinations for structural members loaded with dead and live loads: U 1.4D ACI 318, Eq. 9-1 U 1.D 1.6L ACI 318, Eq. 9- Check Floor Live Load Reduction per ASCE 7-10, sections 4.8. 30

15 L Lo (0.5 ) ASCE 7-10, Eq (4-1) K LLAT where Live Load Element Factor, K LL for interior beams [ASCE/SEI 7-10, Table 4-] Tributary Area (30' 0" 3' 0") 960 ft L o 80 psf A T 15 L 80 (0.5 ) 47.4 psf which satisfies 0.50 Lo requirement for members 960 supporting only one floor per ASCE 7-10, section 4.8.1 Live Load, L 0.0474 3 1. 5 klf Try 36 in width for the beam (slightly larger than the column width that helps facilitate the forming, and reduces the beam longitudinal vs. column vertical bar interference) 5 Joist & Slab Weight 1 6 8.66 / 1 1 36 Beam Weight 0.15 0. 79 klf 1 1 Superimposed Dead Load, SDL 0.0 3 0. 64 klf 16 36 / 6 0.15 3.40 1 klf 1 Factored total load per Eq. 9-1: U 1.4.40 0.79 0.64 5. 36 klf Factored total load per Eq. 9-: U 1..40 0.79 0.641.6 0.0474 3 7. 0 klf Span loads are governed by load combination per Eq. 9-..3.. Determination of span loads Using the approximate coefficients of ACI 318, 8.3.3, the factored moments, and shears are summarized in the Table.3..1, and.3.. respectively below. End Spans Interior Spans Table.3..1 Interior Beam Design Moments Location Design Moment Value Exterior Support Negative Mid-span Positive Interior Support Negative Mid-span Positive Support Negative w ul 4 n w ul 14 w ul 10 n n w ul 16 w ul 11 7.0 8.17 16 7.0 8.17 14 7.0 8.08 10 n n 7.0 8 16 7.0 8 11 348. ft-kips 397.9 ft-kips 553.5 ft-kips 344 ft-kips 500.3 ft-kips 31

Table.3.. Interior Beam Design Shears Location Design Shear Value End Span at Face of wuln 7.0 8.17 1.15 1.15 113.7 kips First Interior Support w At Face of all other Supports u l n 7.0 8.17 98. 9 kips.3.3. Flexural Design For this interior beam, the end span moment values govern the design as tabulated in Table.3..1. Calculate the required reinforcement to resist the first interior support negative moment: M u 553.5 ft-kips Assume tension-controlled section ( 0. 9 calculations below. ).Note that this assumption shall be verified within the Clear cover to the stirrup is 1.5 in. per ACI 318, 7.7.1. However, in order to avoid interference with joist negative moment reinforcement, the clear cover to the girder top reinforcement is required to be increased by lowering the girder top reinforcement. By assuming the maximum bar size for beam top reinforcement as No. 8, the distance from extreme compression fiber to the centroid of longitudinal tension reinforcement, d, is calculated below: 3 6 8 d 1 1.5 0.5 17.88 8 8 8 in Since we are designing for the negative moment in a Rectangular Beam (narrow compression zone), select a moment arm, jd approximately equal to 0.9d. Assume that jd 0.9d 0.9 17.88 16. 09 in. Mu Mu 553.5 1,000 Required reinforcement @ initial trial, As f yd a / f yjd 0.9 60,00016. 09 A s 7.64 in Use one-iteration to refine this value by inserting it in the equation that finds the depth of the equivalent stress block. As fy 7.64 60,000 Depth of equivalent stress block, a 3. 0 in. 0.85f b 0.85 5,000 36 a 3.0 Neutral axis depth, c 3. 53 in. 0.85 1 c 0.003 0.003 Strain at tensile reinforcement, t ( )dt 0.003 ( )17.88 0.003 0.01 0. 005 c 3.53 Therefore, the section is tension-controlled. Use the value of a, ( a 3.0in), to get an improved value for A s. A s Mu 553.51,000 7.51 in a 3.0 f y (d ) 0.9 60,000 (17.88 ) According to ACI 318.10.5.1, the minimum reinforcement shall not be less than 3

A s,min 3 fc 3 5,000 bwd 3617.88.8 in f 60,000 y 00b w d 00 36 17.88 and not less than. 15 in f y 60,000 Provide 10 No. 8 bars with provided reinforcement area of 7.90 in which is greater than required reinforcement of 7.51 in. Check the requirement for distribution of flexural reinforcement to control flexural cracking per ACI 318-11, 10.6. Maximum spacing allowed, 40000 40000 s 15.5c c 1 f s f s c c 1.0 17.88 0.5 8 /8. 6 in. Use f s f y 40 ksi 3 40000 s 15.5.6 8.45 in. (governs) 40000 40000 s 1 1 in. 40000 1 Spacing provided for 10-No. 8 bars 36.65 3. 4 in. 8. 45 in. O.K. 9 Check the spacing, s provided, is greater than the minimum center to center spacing, s min where s min d b 1 max d b 1.33 max.agg. where maximum aggregate size is ¾ s min 11 in Since the spacing provided is greater than in. Therefore, 10 No. 8 bars are O.K. All the values on Table.3.3.1 are calculated based on the procedure outlined above. Design Moment, M u (ft-kips) Effective depth, d (in) Table.3.3.1 Reinforcing Design Summary End Span Exterior Negative Positive Interior Negative Interior Span Positive Negative 348. 397.9 553.5 344 500.3 17.88* 19.0** 17.88 19.0 17.88 A s req d (in ) 4.57 4.9 7.51 4. 6.73 A s min (in ).8.4.8.4.8 Reinforcement 6-No. 8 7-No. 8 10-No. 8 6-No. 8 9-No. 8 33

* The beam top bars are to be placed below the joist top bars. ** The beam bottom bars are to be placed at the bottom-most layer. The joist bottom bars, then, shall be spliced at joist-beam intersection..3.4. Shear Design From Table.3.. above, the shear value in end span at face of first interior support governs. Shear in end members at face of first interior support 1.15w uln 1.15 7.0 8.17 Vu 113.7 kips The design shear at a distance, d, away from the face of support, 17.88 V u 113.7 7.0 103. kips 1 Shear strength provided by concrete Vc ( f ' c bwd) 0.75 1.0 5000 3617.88 6873lb 68. 3 kips Vc Since Vu, shear reinforcement is required. Try No. 3, Grade 60 four-leg stirrups ( A v 0. 44 in ) with a 90 hook. The nominal shear strength required to be provided by steel is Vu 103. Vs Vn Vc Vc ( ) 91.1 46.5 kips 0.75 Check whether V is less than8 f bwd s c If V is greater than s 8 c w f b d, then the cross-section has to be increased as ACI 318-11.4.7.9 limits the shear capacity to be provided by stirrups to 8 w fc b d. f b d 8 5,000 3617.88 36410 lb 364. 1kips 8 c w Since Vs does not exceed 8 f bwd. The cross-section is adequate. Calculate the required stirrup spacing as A vfytd 0.75 0.44 6017.88 s(req' d) 10.1in. Vu Vc 103. 68.3 Check whether the required spacing based on the shear demand meets the spacing limits for shear reinforcement per ACI 318, 11.4.5.1. Check whether V is less than f b d s c 4 c w If V s is greater than 4 fc bwd, then the maximum spacing of shear reinforcement given in 11.4.5.1 and 11.4.5. shall be reduced by one-half per ACI 318.11.4.5.3 f b d 4 5,000 3617.88 18060 lb 18. 1kips 4 c w Since V does not exceed s f b d, the maximum stirrups spacing limits per ACI 318.11.4.5.1 4 c w govern. Therefore, maximum stirrup spacing shall be the smallest of d and 4 in. 34

s(max) d 17.88 Min ; 4 in Min ; 4 in s(max) 8.94 in. This value governs over the required stirrup spacing of 10.1 in based on the demand. Check the maximum stirrup spacing based on minimum shear reinforcement Avf s(max) 0.75 f ' yt c b w 0.4460000 13.9 in (does not govern) 0.75 5000 36 Avfyt 0.44 60000 s(max) 14.7 in (does not govern) 50bw 50 36 Therefore, s(max) value is governed by the spacing limit per ACI 318, 11.4.5.1, and is equal to 8.94 in. Use No. 3 @ 8 in. stirrups V n A vf s yt d 0.44 60 17.88 Vc 91.1 59.0 91.1 150.1 kips 8 V n 0.75150.1 11.6 kips > V u 103. kips O.K. Vu V Compute where is equal to c, and the stirrups can be stopped Vu Vc ( ) ( ) ln x Vu 103. 91.1 ( ) ( ) 0.75 8.17 1 x 113 in. 103. ( ) 0.75 At interior end of the exterior span, use 16-No. 3 @ 8 in o.c., Place 1 st stirrup in. from the face of the column..3.5. Deflections ACI 318 provides the minimum thickness of nonprestressed beams in Table 9.5(a) unless deflections are calculated. Since the preliminary beam depth met this requirement, the deflection calculations are waived here. Typically, in hand solutions, the designer opts to follow ACI 318, 9.5. in lieu of deflection calculations which can be long and tedious. It should be noted that, in most other cases, lesser thicknesses and consequent cost savings can be achieved through deflection computations..3.6. Computer Program Solution spslab Program is utilized to design the interior beam. The interior beam is modeled as a rectangular beam. The program calculates the internal forces (shear force and bending moment), moment and shear capacities, immediate and long-term deflection results, and required flexural reinforcement. The graphical and text results are provided below for both input and output of the spslab model. 35

.3.6.1. Isometric View of Interior Beam from spslab 36

.3.6.. spslab Model Calculated Internal Forces (Shear Force & Bending Moment) 37

.3.6.3. spslab Model Calculated Immediate Deflections 38

.3.7. Summary and Comparison of Design Results Span Location End Span Table.3.7.1 Comparison of Hand Solution with spslab Solution Required Reinforcement Area for Flexure (in ) Hand Solution spslab Solution Reinforcement Provided Hand Solution spslab Solution Interior Negative 7.51 6.576 10 No. 8 9 No. 8 Positive 4.9 4.045 7 No. 8 6 No. 8 39

.3.8. Conclusions and Observations In this design example, the interior beam is modeled as a continuous rectangular beam. There is a good agreement between the hand solution and computer solution. 40

.4. Design of a Continuous Beam along Grid A (Exterior Frame) Design of the interior beam along grid B shall be performed. In the wide-module joist construction, the supporting beam depths shall be same as the overall joist depth. Therefore, the beam depth is set at 1 in. This depth satisfies the minimum thickness requirement of ACI 318, Table 9.5 (a) so that the deflection computations can be waived. The beams of the exterior frame shall be designed and detailed for the combined effects of flexure, shear, and torsion according to ACI 318. Figure.4 Partial plan view showing exterior beam along grid A The design involves the following steps:.4.1. Determination of span loads.4.. Determination of design moments and shears.4.3. Flexural and Torsion Design.4.4. Shear Design.4.5. Deflections.4.6. Computer Program Solution.4.7. Summary and comparison of design results.4.8. Conclusions and observations.4.1 Determination of span loads ACI 318, 9..1 gives the following load combinations for structural members loaded with dead and live loads: U 1.4D ACI 318, Eq. 9-1 U 1.D 1.6L ACI 318, Eq. 9-41

Check Floor Live Load Reduction per ASCE 7-10, sections 4.8. 15 L Lo (0.5 ) ASCE 7-10, Eq (4-1) K LLAT where K LL for edge beams without cantilever slabs Tributary Area A T (30' 0" 16' 10") 505 ft L o 80 psf 15 L 80 (0.5 ) 57.8 psf which satisfies 0.50 Lo requirement for members 505 supporting only one floor per ASCE 7-10, section 4.8.1 10 Live Load, L 0.057816 0. 97 klf 1 Try 4 in width for the beam (slightly larger than the column width that helps facilitate the forming, and reduces the beam longitudinal vs. column vertical bar interference) 5 6 8.66/ 16 4 Joist & Slab Weight / 6 0.15 16 1.4 klf 1 1 1 1 1 4 Beam Weight 0.15 0. 55 klf 1 1 Superimposed Dead Load, SDL 0.016 10/1 0. 34 klf Factored total load per Eq. 9-1: U 1.4 1.4 0.55 0.34. 95 klf 10 Factored total load per Eq. 9-: U 1. 1.4 0.55 0.341.6 0.057816 4. 08 klf 1 Span loads are governed by load combination per Eq. 9-..4. Determination of span loads Using the approximate coefficients of ACI 318, 8.3.3, the factored moments, and shears are summarized in the Table.4..1, and.4.. respectively below. End Spans Interior Spans Table.4..1 Exterior Beam Design Moments Location Design Moment Value Exterior Support Negative Mid-span Positive Interior Support Negative Mid-span Positive Support Negative w uln 4 w ul 14 n w ul 10 n w ul 16 w ul 11 4.08 8.17 16 4.08 8.17 14 4.08 8.08 10 n n 4.08 8 16 4.08 8 11 0.4 ft-kips 31.3 ft-kips 31.7 ft-kips 199.9 ft-kips 90.8 ft-kips 4

Table.4.. Exterior Beam Design Shears Location Design Shear Value End Span at Face of wuln 4.08 8.17 1.15 1.15 66.1 kips First Interior Support w At Face of all other Supports u l n 4.08 8.17 57. 5 kips.4.3. Flexural, Shear, and Torsion Design For this exterior beam, the end span moment values govern the design as tabulated in Table.4..1. Calculate the required reinforcement for negative flexural moment, M u 31. 7 ft-kips Assume tension-controlled section ( 0. 9 ).Note that this assumption shall be verified within the calculations below. Clear cover to the stirrup is 1.5 in. per ACI 318, 7.7.1. However, in order to avoid interference with joist negative moment reinforcement, the clear cover to the girder top reinforcement is required to be increased by lowering the girder top reinforcement. By assuming the maximum bar size for beam top reinforcement as No. 8, the distance from extreme compression fiber to the centroid of longitudinal tension reinforcement, d, is calculated below: 3 6 8 d 1 1.5 0.5 17.88 8 8 8 in Since we are designing for the negative moment in a Rectangular Beam (narrow compression zone), select a moment arm, jd approximately equal to 0.9d.Assume that jd 0.9d 0.9 17.88 16. 09 in. Mu Mu 31.7 1,000 Required reinforcement @ initial trial, As f yd a / f yjd 0.9 60,00016. 09 A s 4.44 in Use one-iteration to refine this value by inserting it in the equation that finds the depth of the equivalent stress block. As fy 4.44 60,000 Depth of equivalent stress block, a. 61in. 0.85f b 0.85 5,000 4 a.61 Neutral axis depth, c 3. 07 in. 0.85 1 c 0.003 0.003 Strain at tensile reinforcement, t ( )dt 0.003 ( )17.88 0.003 0.014 0. 005 c 3.07 Therefore, the section is tension-controlled. Use the value of a, ( a.61in), to get an improved value for A s. A s Mu 31.7 1,000 4.31in a.61 f y (d ) 0.9 60,000 (17.88 ) According to ACI 318.10.5.1, the minimum reinforcement shall not be less than 43

A s,min 3 fc 3 5,000 bwd 417.88 1.5 in f 60,000 y 00bwd 00 4 17.88 and not less than 1. 51 in f 60,000 y All the values on Table.4.3.1 are calculated based on the procedure outlined above. Design Moment, M u (ft-kips) Effective depth, d (in) Table.4.3.1 Reinforcing Design Summary (Flexure only) End Span Interior Span Exterior Negative Positive Interior Negative Positive Negative 0.4 31.3 31.7 199.9 90.8 17.88 19.0 17.88 19.0 17.88 A s req d (in ).64.84 4.31.44 3.87 A s min (in ) 1.5 1.61 1.5 1.61 1.5 The actual selection of reinforcing bars will be delayed until the torsion requirements for longitudinal steel have been determined. Calculate the factored Torsional Moment, T u Since beam between grids 1 and is part of an indeterminate framing system in which redistribution of internal forces can occur following torsional cracking, the maximum factored torsional moment T u at the critical section located at a distance d from the face of the support can be determined from the following per ACI 318, 11.5.. (a): A ' cp T u 4 f c p cp This type of torsion is referred to as compatibility torsion, the magnitude of which is greater than the factored torsional moment,, below which torsional effects can be neglected, where T u,min f ' c A p cp cp T u, min Since the beams are cast monolithically with slab and joists, A cp and p cp for the beam can include a portion of the adjoining slab. The effective width, b e, of the overhanging flange must conform to ACI 318, 13..4: b b e e A cp p cp h h 4h f f 1 5 16.0 in. (governs) 4 5 0.0 in. (1 4) (165) 584in (1 4 16) 1 in. 44

Acp / pcp 796 in. 3 The torsional properties of the beam ignoring the overhanging flange are the following: A cp p cp (1 4) 504in. (1 4) 90in. Acp / pcp 8 in 3 796 in 3 Therefore, ignore flange per ACI 318, 11.5.1.1. T u 0.75 4 5,000 8 598637 in.-lbs 49. 9 ft-kips It is assumed that the torsional loading on the beam is uniformly distributed along the span. Determine the Adequacy of Cross-sectional Dimensions for the Torsion For solid sections, the limit on shear and torsion is given by: V u Tu p h Vc ' 8 f c b wd 1.7A oh b wd Using d 17. 88 in., the factored shear force at the critical section located at a distance d from the face of the support is: 17.88 V u 66.1 4.08 60 kips. 1 Also, the nominal shear strength provided by the concrete is: ' Vc fc b wd Assuming a 1.5-in. clear cover to No. 4 closed stirrups at bottom and.15 in clear cover to No. 4 closed stirrups at top. A oh p h 1.15 1.5 0.5 4.15 1.5 0.5 335. 4 1.15 1.5 0.5 4.15 1.5 0.5 73. 5 in in 60000 417.88 49.9 1000 73.5 1.7 335.4 69.3 psi 5000 417.88 0.75[( ) 8 5,000] 530.3 psi 417.88 Therefore, the section is adequate. Determine the Transverse Reinforcement Required for Torsion At Tu s Aof yt cot where A o 0.85 A 0.85 335.4 85.1 in oh 45 Therefore, A t 49.9 1000 0.033 in / in per leg s 0.75 85.1 60000 cot 45 45

Determine the Transverse Reinforcement Required for Shear From Table.4.. above, the shear value in end span at face of first interior support governs. Shear in end members at face of first interior support 1.15w uln 1.15 4.08 8.17 Vu 66.1 kips The design shear at a distance, d, away from the face of support, 17.88 V u 66.1 4.08 60 kips 1 Nominal shear strength provided by concrete: Vc f ' c bwd 1.0 5000 417.88 60687lb 60. 7 kips Design shear strength provided by concrete: 1.0 5000 417.88 45515 V ( f ' b d) 0.75 lb 45. 5 kips c c w Since the factored shear force, V u, exceeds one-half of the design shear strength provided by concrete, V c, shear reinforcement is required per ACI 318, 11.4.6.1. Since the factored shear force, V u, exceeds the design shear strength provided by concrete, Vc, minimum shear reinforcement per ACI 318, 11.4.6.3 shall not be sufficient and the shear reinforcement shall be provided to satisfy ACI 318, Eq. 11-1 and 11-. Vn V u Vn Vc Vs Therefore, the nominal shear strength required to be provided by steel: Vu 60 Vs Vn Vc Vc ( ) 60.7 19.3 kips 0.75 If V is greater than s 8 c w f b d, then the cross-section has to be increased as ACI 318-11.4.7.9 limits the shear capacity to be provided by stirrups to 8 w fc b d. f b d 8 5000 417.88 4747 lb 4. 7 kips 8 c w Since Vs does not exceed 8 f bwd. The cross-section is adequate. The required transverse reinforcement for shear is: c Av Vu Vc 60 45.5 0.018 in / in s f ytd 0.756017.88 Calculate total required transverse reinforcement for shear and torsion A v A t in. / in. 0.018 0.033 0. 0647 in. /in. s s leg Minimum transverse reinforcement for shear and torsion is calculated per ACI 318, 11.5.5. Av At ' bw 4 0.75 fc 0.75 5000 0.01 in. /in. s s fyt 60000 but shall not be less than b / f 50 4/ 60000= 0.00 in. /in. 50 w yt A v A t Provide 0. 0647 in. /in. as closed stirrups. s s 46

Maximum spacing of transverse torsion reinforcement per ACI 318, 11.5.6.1 is: Minimum of ( p h / 8;1) Min(73.5 / 8,1) Min(9.19;1) 9. 19 in Spacing limits for shear reinforcement per ACI 318, 11.4.5.1 is: Minimum of ( d / ;4) Min(17.88 / ;4) Min(8.94;4) 8. 94 in (governs) Assuming No. 4 closed stirrups with legs (area per leg 0. 0 in ), the required spacing, s, at the critical section is s 0.40/ 0.0647 6.18 in 8. 94 in Provide No. 4 closed stirrups spaced at 6 in. on center. In view of the shear and torsion distribution along the span length, this same reinforcement and spacing can be provided throughout the span length. Determine the Longitudinal Reinforcement Required for Torsion per ACI 318, 11.5.3.7 A f t yt 60 A p l h cot 0.033 73.5 cot 45 1.71 in s f y 60 The minimum total area of longitudinal torsional reinforcement per ACI 318, 11.5.5.3 A where l,min 5 ' c f A f y cp At p s h f f yt y A t / s 0.033 in. /in b / f 54/ 60000 0. 010in /in 5 w yt 5 5000 504 60 l, 0.033 73.5 1.6 in A l 1. 71 in 60000 60 A min Use A l 1. 71 in According to ACI 318, 11.5.6., the longitudinal reinforcement is to be distributed around the perimeter of the stirrups, with a maximum spacing of 1 in. There shall be at least one longitudinal bar in each corner of the stirrups. And longitudinal bars shall have a diameter at least 0.04 times the stirrup spacing, but not less than 3/8 in. In order to meet maximum spacing requirement a rebar is to be provided between corner bars at all four sides. This configuration leads to eight-bars; three at top, three 1.71 at bottom, and one at each side. Therefore, the reinforcement are per bar is A s 0. in. 8 Use No. 5 bars for longitudinal bars which also meets minimum bar diameter requirement of 3/8 in. At the negative moment regions (support-top) and positive moment region (midspan-bottom), the required longitudinal torsional reinforcement shall be provided as addition to the area of required flexural reinforcement. At midspan-top region where flexural reinforcement is not required by analysis, 3-No. 5 bars shall be provided. Class B lap splice is to be provided. 47

Required Longitudinal Reinforcement (in ) Required Torsional Longitudinal Reinforcement (in ) Required Total Longitudinal Reinforcement (in ) Table.4.3. Reinforcing Design Summary (Flexure + Torsion) End Span Interior Span Exterior Negative Positive Interior Negative Positive Negative.64.84 4.31.44 3.87 0.66 0.66 0.66 0.66 0.66 3.30 3.50 4.97 3.10 4.53 Reinforcement 5-No. 8 5-No. 8 7 No. 8 4-No. 8 6-No. 8 Check the requirement for distribution of flexural reinforcement to control flexural cracking per ACI 318-11, 10.6. Maximum spacing allowed, 40000 40000 s 15.5c c 1 f s f s c c 1.0 17.88 0.5 8 /8. 6 in. Use f s f y 40 ksi 3 40000 s 15.5.6 8.45 in. (governs) 40000 40000 s 1 1 in. 40000 Spacing provided for 4-No. 8 bars, (governs the maximum spacing check) is 1 4 3.0 6 in. 8. 45 in. O.K. 3 Check the spacing, s provided, is greater than the minimum center to center spacing, s min where s min d b 1 max d b 1.33 max.agg. where maximum aggregate size is ¾ s min 11 in Spacing provided for 7-No. 8 bars, (governs the minimum spacing check) is 1 4 3.0 3 in.. 0 in. O.K. 6 Therefore, the reinforcement selections in Table.4.3. meet the spacing requirements. 48

.4.4. Deflections ACI 318 provides the minimum thickness of nonprestressed beams in Table 9.5(a) unless deflections are calculated. Since the preliminary beam depth met this requirement, the deflection calculations are waived here. Typically, in hand solutions, the designer opts to follow ACI 318, 9.5. in lieu of deflection calculations which can be long and tedious. It should be noted that, in most other cases, lesser thicknesses and consequent cost savings can be achieved through deflection computations..4.5. Computer Program Solution spslab Program is utilized to design the exterior beam. The exterior beam is modeled as a rectangular beam. The program calculates the internal forces (shear force and bending moment), moment and shear capacities, immediate and long-term deflection results, and required flexural reinforcement. The graphical and text results are provided below for both input and output of the spslab model. Decremental reinforcement design solve option is utilized. This option makes the program start from the Max. Bar Size under Reinforcement Criteria for designing the reinforcement and works its way down to Min. Bar Size. The use of this option results in 5-No. 8 bars top reinforcement at the first interior support @ end span. If this option is unchecked, the program shall provide 9-No. 6 bars. 49